MATCH LINE MATCH LINE

CANOPY -3

PROPOSED
V.C V.C
STAIR CASE - 04
PFT DN
EMG
14'-7"x7'-0"
O.C
8'-2"x7'-0" ELECTRICAL.
O.C
1-008 ROOM STAIR
PATIENT CHANGING 1-005 EXISTING
TOILET,
AHU 6'-2"x14'-4" STAIR CASE - 03 LOBBY AHU-1
LIFT & LOCKERS 31'-0"x14'-0" V.C V.C 6'-0" X 10'-0" 55'-0"x13'-11 21"
1-007A
6'-6"x14'-2" 1-004 1-037
1-001 V.C V.C V.C
UP
WAITING
OPD TMT 1-037
14'-7"x7'-0" 8'-2"x7'-0"
O.C
VOID BELOW 1-006 1-007

V.C V.C C10


DN
FHC

9'-6" CORRIDOR C11 C11


9'-6" CORRIDOR

NURSE STATION
8'-5"x5'-8"
O.C WC
1-009 CATH
11'-0"x5'-8" TECHNICAL AREA
1-011 W.C W.C 8'-8"x7'-0"
LAB
5'-8"x9'-5" 5'-8"x9'-5" M.CHANGING 1-032C 23'-10"x20'-5"
1-017 1-018 ANTE ROOM 8'-8"x12'-0" 1-033 CURTAIN WALL
1-032A
9'-921"x12'-0"
DIRTY UTILITY 1-033A
4'-6"x6'-8" V.C V.C F.CHANGING
1-012 8'-921"x4'-7"
1-032B
VOID BELOW

7 DIRTY UTILITY
11'-9"x5'-821"
6'-7" CORRIDOR

1-018A
COURTYARD
36'6"X26'0"

6'-0" CORRIDOR
RECOVERY WAITING

6'-0" CORRIDOR
26'-10"x21'-4" 1-037A
1-010
V.C V.C
PREPARATION
25'-4"x16'-9"
1-029

VOID BELOW SLIDING DOOR


PRE-OP. CONTROL
ANTE ROOM ROOM
13'-0"x10'-7 21" 13'-3"x10'-721"
1-033B 1-034
CUPBOARD
DIRTY UTILITY SCRUB
DISINFECTION V.C V.C
CUPBOARD
CANOPY -2 CLEANING 10'-5" X4'-1 21"
1-030B
12'-5"x8'-221" CLEAN
1-020A UTILITY
TOILET
10'-5" X5'-0" 10'-0" X8'-0"
1-030A 1-035A
13'-9" WIDE CORRIDOR

UPS UPS
FHC
VOID BELOW

V.C V.C
PLANT
ROOM
ENDO 1 ENDO 2 BATTERY10'-0"x6'-8" BATTERY DUCT 2'0" WIDE
13'-2"x15'-8" 13'-3"x15'-8" 1-035
1-019 1-020 RECOVERY
STORE 17'-8"X14'-4"
CATH ELV & IT
MEDICATION
5'-921" x11'-0" 1-035A LAB ROOM DN
5'-9 21"x11'-0"
1-027A 1-030 23'-11"x20'-5" 6'-4"x8'-3" STAIR -01
TECHNICAL 1-038B
1-036 LIFT
AREA LOBBY.
10'-0"x7'-3" 8'-3" WIDE
V.C V.C 1-035B UP

ENDO CCU CATH LAB

CANOPY -1

MATCH LINE MATCH LINE

WING-1

ISSUED PRINCIPLE ARCHITECT ARCHITECT ELECTRICAL CONSULTANT NOTES


PROJECT Rev. DESCRIPTION DATE DRAWN DATE NORTH REVISION
VITAL ASSOCIATES
5 CHANGES AS CLOUDED
4 Ch. Khaliquzzaman Road, Karachi 75530
LAHORE GATE HOSPITAL ISSUED FOR CONSTRUCTION Tel: 5661683,5661684, Fax: 92-21-5686891 Vital Associates
6 CHANGES AS CLOUDED
W.Z NOVEMBER-2018 C11
7 CHANGES AS CLOUDED 24-05-18
CLIENT TITLE STRUCTURE CONSULTANT M&P CONSULTANT Rev. DESCRIPTION DATE 8 CHANGES AS CLOUDED 13-06-18
CHECK SCALE SHEET
Y.H. ASSOCIATES 1 NEW DOOR ADDED C9 IMAGINE AREA FURNITURE 20-08-18
FIRST FLOOR WING-1 CONSULTING ENGINEERS
2 ADDED 9"THK. FIRE RATED WALL C10 WATER SPRINKLER & BIOMETRIC POINTS 29-08-18

A-28.1
308 & 309, 3rd FLOOR, ANUM ESTATE,

GATE HEALTHCARE 1 PAK PVT. LTD. FURNITURE LAYOUT RRP INTERNATIONAL HOSPITAL PLANNERS PTE LTD
SINGAPORE ─ GERMANY
ALI CONSULTANT SHAHRAH-E-FAISAL, KARACHI-75350, PAKISTAN
PHONE NO : + 921 - 4315071 & 2 ;
3 CHANGES AS CLOUDED C11 SHOWER ADD & CATH LAB CHANGES 18-09-18
MAQ 3/16" =1'-0"
FAX NO :+ 921 - 4382527 EMAIL:info@yhassociates.com 4 CHANGES AS CLOUDED