Professional Documents
Culture Documents
Master Plumbing 3
Master Plumbing 3
Correct
Q.2) What do you call the installation of all pipes in the plumbing system that is in
partitions and under floors?>
A. Tempering
B. Roughing-in (Your Answer)
C. Concealed plumbing
D. Fixturing
Correct
Q.3) What will be the basis in the design of waer piping sytem in localities where the
water pressure is fluctuating all throughout the day?
Q.4) What do you call a hemp or old hemp rope soaked in oil or tar to make it
waterproof?
A. Sisal
B. Manila
C. Abaca
D. Oakum (Your Answer)
Wrong
Q.5) Through what means must waste of food handling equipment discharge?
A. Vertical gap
B. Grease interceptor (Your Answer)
C. Indirect Waste pipe (Correct Answer)
D. Direct connection
Correct
Q.7) When was NAMPAP registered with the Securities and Exchage Commission?
A. 1925
B. 1942
C. 1937
D. 1935 (Your Answer)
Wrong
Q.8) A horizntal drain that is sized to provide free movement of air above the flow
line of the drain is called a ___
Q.9) What should be made of connections between a potable water supply and an
automatic fire sprinkling machine?
Q.10) What type of concealed connections on fixtures shall be provided with access
panel or utility at least 0.3m in its least dimension for easy inspection and
repair?
A. Hubless
B. Flanged
C. Slip joint (Your Answer)
D. Ball and socket
Wrong
Q.11) Fixture connections that require the removal of an access panel for servicing are
considered ____.
Q.13) What is that portion of rainfall or other precipitation which runs off over the
surface of the ground called?
Q.14) How many pipes that discharge into a drainage system but which are not
connected directly to the drainage system clasiffied?
A. Complex wastes
B. Indirect wastes (Your Answer)
C. Special wastes
D. Direct wastes
Wrong
Q.16) What is a liquid waste that contains animal or vegetable matter in suspension or
solution?
A. Sewer
B. Sewage (Correct Answer)
C. Domestic waste (Your Answer)
D. Culinary waste
Correct
Q.17) What tank is integral with water closet, urinal, or similar fixtures for flushing or
removing excrements in the fixture?
Q.19) What must be fitted on a fixture that is equipped with threads for a garden
hose?
A. Check valve
B. Backflow preventer
C. Air gap (Your Answer)
D. Vacuum breaker (Correct Answer)
Correct
A. Relief vents
B. Common vents
C. Wet vents (Your Answer)
D. Dry vents
Wrong
Q.23) What tube is made of plastic material and colored black whose cross-sectional
shape is normally oval and is denoted by its outside diameter and is normally
used as water service connection from the main to the meter.
Q.24) What is the minimum height of raised letters on an iron or bronze sign that will
read "Connection to Dry Standpipe"
A. 25 mm (Your Answer)
B. 3/4 inch
C. 20 mm
D. 30mm
Correct
Q.25) Unless prohited by structural conditions, what is the reference of each vertical
vent pipes before offsetting horizontally to join the stack vent or vent stack?
A. Invert of trap
B. Highest flood level rim of fixture (Your Answer)
C. Water level inside the trap
D. Air gap of fixture
Correct
Q.27) What do you call a drainage piping that extends from the trap of a fixture to
appoint connection with another drain pipe?
A. Horizontal stack
B. Branch supply
C. Trap Arm (Your Answer)
D. Fixture drain
Wrong
Q.28) Who was the President of the Republic of the Philippines who signed the
"Plumbing Law of the Philippines"?
A. Joseph Estrada
B. Diosdado Macapagal
C. Ramon Magsaysay (Correct Answer)
D. Ferdinand Marcos (Your Answer)
Correct
Q.29) What pipe conveys potable water from a building supply to a plumbing fixture?
Q.30) What do you call the pipe or tubing that connects the oultlet of a plumbing
fixture to the trap?
A. Outflow
B. Tailpiece (Your Answer)
C. Head Tubing
D. Connector
Correct
Q.31) What do you call a combination of elbows or bends which brings one section of
pipe out of line but into a line parallel with the other section of the pipe?
A. 140 psi
B. 125 psi (Correct Answer)
C. 100 psi
D. 75 psi (Your Answer)
Correct
Q.33) What do you call a water supply pipe connecting the fixtures with the fixture
branch?
A. Corporation
B. Service
C. Fixture supply (Your Answer)
D. Special
Wrong
A. Ejector
B. Sump pump
C. Pressure controller (Your Answer)
D. Centrifugal pump (Correct Answer)
Correct
Q.35) What is the receptacle wherein liquids are retained for a sufficient period of
time to allow settleable materials to deposit?
Q.36) What device is used to prevent backflow into a potable water supply?
Q.37) What screened vent shall be used to vent the covers of gravity storage tank of
potable water supply?
Q.38) What is represented by a solid line broken with a single dot or dash in piping
diagrams?
Q.39) What interior pipes are used to convey storm water from a roof drain to appoint
of disposal?
A. Leaders
B. Conductors (Your Answer)
C. Wet stacks
D. Stacks
Correct
Q.40) Connections between drain and floor outlet plumbing fixtures must be made
with which of the following?
A. Mechanical joints
B. Electromeric seal
C. Schedule-40 joints
D. Floor flanges (Your Answer)
Correct
Q.41) What is a recession in a wall for holding pipes and conduits passing from floor
to floor?
A. Vent
B. Court
C. Chase (Your Answer)
D. Yard
Correct
Q.42) In water supply and distribution, what type of fillway valve should be used to
control or more openings?
A. Ball valve
B. Butterfly valve
C. Globe valve
D. Gate valve (Your Answer)
Correct
Q.43) What system describes soil or waste system where all pipings are of threaded
pipe, tubing or other such rigid construction using recessed drainage fittings to
correspond to the types of piping?
Q.44) After how many days shall a plumbing permit expire and become null and void
if the plumbing works authorized therein have not been started?
Q.45) What is the minimum number of water closet for 16 to 35 permanent female
emplyees in assembly places such as the theaters, auditoruims and convention
halls?
A. 2
B. 4 (Your Answer)
C. 5
D. 3 (Correct Answer)
Wrong
Q.46) How many threads per inch has a cleanout having a size of 76 mm had?
A. 8 (Correct Answer)
B. 10
C. 5
D. 6 (Your Answer)
Wrong
Q.47) How do you call an auxillary vent which provides additional circulation of air in
or between a drainage system classified?
A. Common vent
B. Relief vent (Correct Answer)
C. Island vent
D. Branch vent (Your Answer)
Wrong
Q.48) what device is present in a water heater that allows the emptying or discharge of
excessive pressure
A. Thermostat
B. Relief valve (Correct Answer)
C. Aquastat (Your Answer)
D. Boiler blowoff
Correct
A. Galvanized iron
B. Cast iron
C. Brass (Your Answer)
D. Copper
Wrong
Q.50) What type of valve in a water system combines to protect agaainst excessive
temperature and pressure build-ups?
Q.51) Grease interceptors must be equipped with devices to control the rate of which
of the following?
A. Heat Transference
B. Air flow
C. Waste flow
D. Water flow (Your Answer)
Wrong
A. 10 ft
B. 3 meters
C. Not more than 5 meters (Your Answer)
D. Not more than 6 ft (Correct Answer)
Wrong
Q.53) For a discharge capacity in the excreta drainage system of 1.0 to 1.89 per
second, what is its assigned equivalent fixture unit when there is an intermittent
flow in the system?
A. 3
B. 2
C. 4 (Correct Answer)
D. 6 (Your Answer)
Correct
Q.54) What type of valve that will be used for all the outlets in a stand pipe
A. Ball
B. Check
C. Gate (Your Answer)
D. Globe
Wrong
Q.55) The trap of a kitchen sink may NOT accept the waste of which of the following?
Q.56) what sewage includes the wastes from metal and chemical plants, oil refineries,
laudries. diary plants and breweries?
A. Residential
B. Commercial
C. Industrial (Your Answer)
D. Institutional
Correct
Q.57) What part of the trap of trapped fixture being served, must individual vents be
connected?
Q.58) From where can liquid waste be disposed off directly into the ground?
A. chemical laboratory
B. church sacaruim (Your Answer)
C. toilet
D. restaurant sink
Wrong
Q.59) How many equvalent water supply fixture unit has the flush tank type of water
closet that is for private use?
A. 4
B. 2
C. 3 (Correct Answer)
D. 5 (Your Answer)
Wrong
Q.60) What feature in water supply is NOT advisable to plumbing fixtures, devices
and opportunities?
Q.61) What is the least diameter (in mm) of building water service pipe that is allowed
by the plumbing Code?
A. 19 (Correct Answer)
B. 12.5 (Your Answer)
C. 10
D. 25
Correct
Q.62) What type of surface must plumbing fixtures should NOT have?
A. Concealed fouling surface (Your Answer)
B. Smooth, impervous purposes
C. China surfaces
D. Stainless steel surfaces
Wrong
Q.63) What do you call the vertical vent pipe installed primarily to provide circulation
of air to and from any part of the drainage system?
A. Common vent
B. Relief vent
C. Vent Stack (Correct Answer)
D. Stack vent (Your Answer)
Correct
Q.64) What pipe carries potable water from the water meter or other source of water
supply to a building or other point of use or distribution on the lot
Q.66) What is the term used which implies siphonage in piping system?
A. Deoxygenation
B. Carbonation
C. Vacuum (Your Answer)
D. Flushing
Correct
Q.67) When a trench is backfilled, at what intervals must the fill material be
compacted?
A. Every 4 inches
B. Every 12 inches
C. Every 6 inches (Your Answer)
D. Every 8 inches
Wrong
A. toilet room
B. bathroom (Your Answer)
C. shower room
D. washroom
Wrong
Q.70) What is the process whereby steel and iron pipes rust?
A. Decay
B. Deoxidation (Your Answer)
C. Ferrule
D. Tuberculation (Correct Answer)
Wrong
Q.71) If the potable water supply is being connected to a non-potable water source,
with what reduced pressure device should connections be made?
Q.72) Which of the following vents does NOT carry liquid or water-borne wastes?
A. Dual
B. Dry (Your Answer)
C. Unit
D. Wet
Correct
Q.73) What do you call an approved tank or pit which recieves sewage or wastewater
below the normal grade and is emtied by mechanical meands?
A. Lateral
B. Sump (Your Answer)
C. Damp
D. Dumping
Wrong
Q.74) Which of the follwing is a common form of protection from corrosion for pipes
passing through concrete?
A. Protective concreting
B. Protective coating (Your Answer)
C. Protective handling
D. Protective wrapping (Correct Answer)
Wrong
Q.75) what do you call the main water pipe which delivers potable water to a building.
A. Water connector
B. Water service (Correct Answer)
C. Water supply (Your Answer)
D. Water distributor
Wrong
Q.76) Which of the follwing is NOT allowed in the construction of a storm water
drainage system?
Q.77) What do you call the water that stands in or passes through the ground?
A. Artesian
B. Surface
C. Deep well
D. Ground (Your Answer)
Correct
Q.79) What is the combination of elbows or bends in aline of piping, which bring one
section of the pipe out of line parallel with the original section?
A. Sanitary piping
B. Piping system
C. Offset (Your Answer)
D. Circuit piping
Correct
Q.80) What device is often used to connect an appliance to a gas source?
Q.81) What is the process by which suspended matter in sewage subsidies and is
deposited by gravity?
A. Clarification
B. Filtration
C. Dilution
D. Sedimentation (Your Answer)
Correct
A. Timed shut-off
B. Slope valve
C. Supply valve
D. Quick closing valve (Your Answer)
Wrong
Q.83) What do you call a waste arrangement that connects multiple compartments of
a set of fixtures, such as double-bowl kitchen sink, to a single trap?
A. A series waste
B. An island waste
C. A continuous waste (Correct Answer)
D. A collecticve waste (Your Answer)
Correct
Q.84) What building drains conveys storm water but not sewage?
A. Combined drain
B. Storm drain (Your Answer)
C. Sanitary drain
D. Surface drain
Correct
Q.86) What is represented by a solid line broken with two dots or dashes in piping
diagrams?
A. Drainage pipe
B. Vent pipe
C. Cold water
D. How water (Your Answer)
Correct
Q.87) The length along the centerline of the pipe and fittings is the ___
A. diagonal length
B. diameter length
C. circumferential length
D. developed length (Your Answer)
Correct
Q.88) What do you call a pipe with a adjacent reverse bends and shaped like the letter
"S"?
Q.89) What type of water closet is installed in such a way that it does not touch the
floor?
A. Hanger
B. Wall-hung (Your Answer)
C. Carrier
D. Handy
Correct
Q.90) If ever it is impractical to install the horizontal drainage piping following the
required minimum slope due to some reasonable constraints, what is the least
required slope that is allowed?
A. 0.5%
B. 1.5%
C. 2.0%
D. 1.0% (Your Answer)
Correct
Q.92) What valve is similar to a compression cock but has a screw outside for a
connection of water hose?
A. Tap
B. Key cock (Your Answer)
C. Hose bibb (Correct Answer)
D. Faucet
Wrong
Q.93) what is the minimum allowed uniform gauge pressure in the piping system if an
air test shall be made?
Q.94) which of the follwong is NOT an element in the computation of the size of grease
interceptors?
A.
B. Diameter of inlet pipe (Correct Answer)
C. Waste flow rate
D. Storage factor (Your Answer)
Wrong
A. 90 degrees bends
B. 45 degrees bends
C. Blind plugs (Your Answer)
D. Cleanouts (Correct Answer)
Correct
Q.96) Which of the following commonly carries both storm water or sewage?
A. Mixed drain
B. Subsoil drain
C. Combined sewer (Your Answer)
D. Sanitary sewer
Correct
Q.97) Which of the following is an impairment of the quality of potable water which
creates a hazard to public health through poisoning or the spread of disease?
A. Imbalance
B. Risk dange
C. Backflow
D. Contamination r (Your Answer)
Correct
Q.98) What do you call a receptacle installed to collect and drain store water from an
open area?
A. Combination Sewer
B. Split drain
C. Area drain (Your Answer)
D. Floor drain
Correct
Q.99) What do you call the vertical distance between the crown weir and the top of the
dip of a trap?
A. Airbreak
B. Airgap
C. Trap seal (Your Answer)
D. Critical level
Correct
A. expansion tank
B. surge tank
C. flushometer tank (Your Answer)
D. day tank
Correct
A. Polybutylene
B. Polyvinyl chloride
C. Polyethylene
D. Black steel (Your Answer)
Correct
Q.102) A vertical vent that is a continuation of the drain to which it connects is a ___
A. circuit vent
B. relief vent
C. continuous vent (Your Answer)
D. branch vent
Correct
Q.103) That part of the lowest piping of a drainage system that recieves the discharge
from soil, waste, and other drainage pipes inside the walls of the building and
conveys it to a point 2 ft. outside the building wall is a ___
Q.104) If there are five or more branch intervals located above a horizontal offset of a
drainage stack, what must be made of the offsets?
Q.105) When plastic pipe is joined with cast-iron pipe, which of the following types of
joints is acceptable?
A. Caulked
B. Solvent weld
C. Threaded
D. Mechanical (Correct Answer)
Correct
Q.106)
Which of the following does NOT belong to sump pump system?
A. Sump pit
B. Sump pump
C. Discharge piping
D. Hinged covers (Your Answer)
Correct
Q.107) What is the allowable distance between the trap arm and the vent if the fixture
has a trap arm diameter of 32mm?
A. 1.52m
B. 0.76 m (Your Answer)
C. 0.51m
D. 1.07m