NH-2120 Pressure Retaining Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7


NH-2121 Permitted Material Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
NH-2123 Design Stress Intensity Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
NH-2160 Deterioration of Material in Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
NH-2433 Delta Ferrite Determination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
NH-2433.1 Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
NH-2433.2 Acceptance Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
NH-2539 Repair of Plates by Welding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
NH-2540 Fatigue Acceptance Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

5
ARTICLE NH-2000
MATERIAL

NH-2120 PRESSURE RETAINING the fittings are in conformance with the requirements
MATERIALS of NB-3671.4 and the material is determined to be
adequate for the service conditions by the piping system
NH-2121 Permitted Material Specifications
designer.
(a) All materials shall comply with the rules of (g) Welding material used in the manufacture of
NB-2000, except for those paragraphs replaced by items shall comply with Table I-14.1(b) and the SFA
correspondingly numbered paragraphs of Subsection specifications in Section II, Part C, and shall also
NH. comply with the applicable requirements of this Article.
(b) In complying with (a) above, the base and weld The requirements of this Article do not apply to material
material specifications of Tables I-14.1, I-14.10, and used as backing rings or backing strips in welded joints.
I-14.11 and the allowable stress intensities in Tables (h) Attachments welded to a pressure boundary (in-
I-14.3 and I-14.13 shall be considered extensions of cluding the weld metal used to make the attachment)
Tables 2A, 2B, and 4 of Section II, Part D, Subpart 1. expecting elevated temperature service need not comply
(c) Pressure retaining material and material welded with the limits on upper values of service temperatures
thereto, except for temporary or nonstructural attach- and times, as stated in Tables 2A, 2B, and 4 of Section
ments as per NB-4435 and in (h) below, and except II, Part D, Subpart 1, provided the rules listed below
for hard surfacing metals and cladding which is 10% are met.
or less of the thickness of the base material, shall (1) The design of the welded attachment complies
conform to the requirements of one of the specifications with the rules in NH-3354.
for material given in Tables 2A, 2B, and 4 of Section (2) The attachment material and weld are of similar
II, Part D, Subpart 1, and to all of the special require- alloy composition to the pressure boundary material.2
ments of this Article which apply to the product form
in which the material is used.
(d) The requirements of this Article do not apply to NH-2123 Design Stress Intensity Values
items not associated with the pressure retaining function Design stress intensity values for material are listed
of a component such as shafts, stems, trim, spray in Tables 2A, 2B, and 4 of Section II, Part D, Subpart
nozzles, bearings, bushings, springs, wear plates, nor 1, as extended in coverage by the rules of NH-2121(b).
to seals, packing, gaskets, valve seats, and ceramic With the exception of attachment material covered by
insulating material and special alloys used as seal NH-2121(h), no material shall be used at metal and
material in electrical penetration assemblies. design temperatures above those for which values are
(e) Material made to specifications other than those given.
specified in Tables 2A, 2B, and 4 of Section II, Part
D, Subpart 1 may be used for safety valve disks and
nozzles, when the nozzles are internally contained by NH-2160 DETERIORATION OF MATERIAL
the external body structure, and for valve disks in line IN SERVICE
valves whose inlet connections are NPS 21 and less.
(f) Material for instrument line fittings, NPS 1 and (a) Consideration of deterioration of material caused
less, may be of material made to specifications other by service is generally outside the scope of this Subsec-
than those listed in Section II, Part D, provided that
2 Different product forms, such as castings, are acceptable for the
1 Values of nominal pipe size have not been converted to SI. attachment.

7
NH-2160 1998 SECTION III, DIVISION 1 — NH NH-2540

tion. It is the responsibility of the Owner to select Number). For design temperatures exceeding 800°F
material suitable for the conditions stated in the Design (427°C), the delta ferrite shall be limited to the range
Specifications (NCA-3250), with specific attention being FN-3 to FN-10. The results of the delta ferrite determina-
given to the effects of service conditions upon the tion shall be included in the Certified Material Test
properties of the material. Report of NB-2130 or NB-4120.
(b) Special consideration shall be given to the influ-
ence of elements such as copper and phosphorus on NH-2539 Repair of Plates by Welding
the effects of irradiation on the properties of material
(including welding material) in the core belt line region The Material Organization may repair by welding
of the reactor vessel. Any special requirement shall be material from which defects have been removed, pro-
specified in the Design Specifications (NCA-3252 and vided the depth of the repair cavity does not exceed
NB-3124). When so specified, the check analysis shall one-third of the nominal thickness and the requirements
be made in accordance with the base metal specification of the following subparagraphs are met. The weld
and in accordance with NB-2420 for the welding ma- material used to make weld repairs shall meet the
terial. requirements of Table I-14.1(b) and NB-2400. Addi-
(c) The combination of fabrication induced cold tional requirements may be listed in the Design Specifi-
working and subsequent elevated temperature service cations, as per NB-2160, to assure that the repair weld
may affect time-dependent material properties. is adequate for the service conditions. Prior approval
of the Certificate Holder shall be obtained for the repair
of plates to be used in the manufacture of vessels.
(NB-2539.1 through NB-2539.7 are unchanged.)

NH-2433 Delta Ferrite Determination


NH-2540 FATIGUE ACCEPTANCE TEST
A determination of delta ferrite shall be performed
(a) For 304 and 316 austenitic stainless steel compo-
on A-No. 8 weld material (QW-442, Section IX) backing
nents intended for service where conditions for levels
filler metal (consumable inserts); bare electrode, rod,
A, B, and C do not satisfy the limits of T-1324(a)
or wire filler metal; or weld metal, except that delta
and (b), a uniaxial fatigue acceptance test of each lot
ferrite determinations are not required for SFA-5.4,
of material shall be performed.
Type 16-8-2, nor A-No. 8 weld filler metal to be used (b) The fatigue test shall be performed in air at
for weld metal cladding. 1,100°F (593°C) at an axial strain range of 1.0% with
NH-2433.1 Method. Delta ferrite determinations of a one-hour hold period at the maximum positive strain
welding material, including consumable insert material, point in each cycle. Test-specimen location and orienta-
shall be made using a magnetic measuring instrument tion shall be in accordance with the general guidance
and weld deposits made in accordance with (b) below. of SA-370, paras. 6.1.1 and 6.1.2 and the applicable
Alternatively, the delta ferrite determinations for weld- product specifications. Testing shall be conducted in
ing materials may be performed by the use of chemical accordance with ASTM Standard E 606. The test shall
analysis of NB-2432 in conjunction with Fig. NB- exceed 200 cycles without fracture or a 20% drop in
2433.1-1. the load range.
(a) Calibration of magnetic instruments shall conform (c) Failure to meet this requirement shall be cause
to AWS-A4.2-91. for rejection of the lot for use in Class 1 elevated
(b) The weld deposit for magnetic delta ferrite deter- temperature components.
mination shall be made in accordance with NB- (d) The definition of “lot” shall be obtained from the
2432.1(c). material specification. Where more than one definition is
(c) A minimum of six ferrite readings shall be taken provided by the specification, the definition used to
on the surface of the weld deposit. The readings obtained establish the tensile properties shall govern. Either the
shall be averaged to a single Ferrite Number. Material Organization or N-Type Certificate Holder
may perform the lot qualification test.
NH-2433.2 Acceptance Standards. For design tem- (e) Retesting is permitted. Two additional specimens
peratures up to and including 800°F (427°C), the mini- shall be tested and both specimens must pass the cyclic
mum acceptable delta ferrite shall be 5-FN (Ferrite life requirement. Further retests are not permitted.

You might also like