1 Input Parameters
Main Module Moment Connection
Module Base Plate Connection
Connectivity Moment Base Plate
End Condition Fixed
Axial Compression (kN) 150.0
Axial Tension/Uplift (kN) 150.0
Shear Force (kN)
- Along major axis (z-z) 100.0
- Along minor axis (y-y) 100.0
Bending Moment (kNm)
- Major axis (Mz−z ) 75.0
- Minor axis (My−y ) 75.0
Column Section - Mechanical Properties
Column Section WPB600X300X128.8
Material E 250 (Fe 410 W)A
Ultimate Strength, Fu (MPa) 410.0
Yield Strength, Fy (MPa) 250.0
Mass, m (kg/m) 120.93 Iz (cm4 ) 76713.64
Area, A (cm2 ) 154.05 Iy (cm4 ) 5415.38
None None rz (cm) 22.32
D (mm) 571.0 ry (cm) 5.93
B (mm) 300.0 Zz (cm3 ) 2686.99
T (mm) 15 Zy (cm3 ) 361.03
t (mm) 12.0 Zpz (cm3 ) 3098.23
Flange Slope 90 Zpy (cm3 ) 5707.69
R1 (mm) 0.0
R2 (mm) 0.0
Base Plate - Design Preference
Material E 250 (Fe 410 W)A
Ultimate Strength, Fu (MPa) 410
Yield Strength, Fy (MPa) 250
Page 1
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 2
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 3
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
2 Design Checks
Design Status Pass
Es
Modular Ratio n= OK
Ec
200000
n=
25000.0
= 8.0
Page 4
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 5
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
2.3 Plate Washer and Nut Details - Anchor Bolt Outside Column Flange
Check Required Provided Remarks
Square − 45X45
Plate Washer Size (mm) Pass
[Ref. IS 6649:1985, Table 2]
tw = 8.5
Plate Washer Thickness (mm) Pass
[Ref. IS 6649:1985, Table 2]
dh = 22
Plate Washer Hole Diameter Pass
(mm) [Ref. IS 6649:1985, Table 2]
tn = 18.0
Nut (hexagon) Thickness Pass
(mm) [Ref. IS 1364-3:2002, Table 1]
End Plate Size (mm) Square - 90 X 90 Pass
End Plate Thickness (mm) 14 Pass
Page 6
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
2.4 Plate Washer and Nut Details - Anchor Bolt Inside Column Flange
Check Required Provided Remarks
Square − 45X45
Plate Washer Size (mm) Pass
[Ref. IS 6649:1985, Table 2]
tw = 8.5
Plate Washer Thickness (mm) Pass
[Ref. IS 6649:1985, Table 2]
dh = 22
Plate Washer Hole Diameter Pass
(mm) [Ref. IS 6649:1985, Table 2]
tn = 18.0
Nut (hexagon) Thickness Pass
(mm) [Ref. IS 1364-3:2002, Table 1]
End Plate Size (mm) Square - 90 X 90 Pass
End Plate Thickness (mm) 14 Pass
Page 7
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 8
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 9
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 10
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 11
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 12
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 13
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 14
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
= 205 + tn + 20
= 205 + 18.0 + 20
= 243.0
Page 15
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
= 200 + tn + 20
= 200 + 18.0 + 20
= 238.0
Page 16
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
= σcallowable σcmax
Stress (average) at Stiff- σstf = Pass
2
= 11.25
ener (N/mm2 ) 10.96
=
2
= 5.48
Page 17
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 18
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
= 18.458
Weld Size (mm) 10 12 Pass
Page 19
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 20
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 21
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
3 2D Drawings (Typical)
Page 22
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 23
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 24
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
Page 25
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
4 3D Views
5 Design Log
2021-05-07 20:15:48 - Osdag - WARNING - The Load(s) defined is/are less than the minimum recommended value [Ref. IS 800:2007,
Cl.10.7].
2021-05-07 20:15:48 - Osdag - WARNING - [Minimum Factored Load] The external factored bending moment (75.0 kNm) is less than
0.5 times the plastic moment capacity of the column (305.34 kNm)
2021-05-07 20:15:48 - Osdag - INFO - The minimum factored bending moment should be at least 0.5 times the plastic moment capacity
of the beam to qualify the connection as rigid connection
2021-05-07 20:15:48 - Osdag - INFO - The value of load(s) is/are set at minimum recommended value as per Cl.10.7
2021-05-07 20:15:48 - Osdag - INFO - Designing the connection for a factored moment of 305.34 kNm
2021-05-07 20:15:48 - Osdag - INFO - [Base Plate Type] The value of eccentricity about the major axis is 290 mm
2021-05-07 20:15:48 - Osdag - INFO - Eccentricity is greater than 263.67 (L/3) mm
2021-05-07 20:15:48 - Osdag - INFO - Case 3: A smaller part of the base plate is under pure compression/bearing with a large
tension/uplift force being transferred through the anchor bolts outside column flange on the tension side
2021-05-07 20:15:49 - Osdag - INFO - [Base Plate Type] The value of eccentricity about the major axis is 290 mm
2021-05-07 20:15:49 - Osdag - INFO - Eccentricity is greater than 263.67 (L/3) mm
2021-05-07 20:15:49 - Osdag - INFO - Case 3: A smaller part of the base plate is under pure compression/bearing with a large
Page 26
Created with
Company Name Project Title
Group/Team Name Subtitle
Designer Job Number
Date 07 /05 /2021 Client
tension/uplift force being transferred through the anchor bolts outside column flange on the tension side
2021-05-07 20:15:49 - Osdag - INFO - [Minor Axis Moment] The value of eccentricity about the minor axis is 70 mm
2021-05-07 20:15:49 - Osdag - INFO - Eccentricity is less than 83.33 mm (W/6)
2021-05-07 20:15:49 - Osdag - INFO - Case 1: The base plate is purely under compression/bearing over it’s width, thus there is no
requirement of anchor bolts along the width of the column section
2021-05-07 20:15:49 - Osdag - INFO - [Design for Shear] The shear resistance of the base plate assembly due to the friction between the
base plate and the grout/concrete material is 472.6539 kN
2021-05-07 20:15:49 - Osdag - INFO - The horizontal shear force - 100.0 kN, is less than the shear resistance of the base plate
2021-05-07 20:15:49 - Osdag - INFO - Shear key is not required
2021-05-07 20:15:49 - Osdag - INFO - [Design for Shear] The shear resistance of the base plate assembly due to the friction between the
base plate and the grout/concrete material is 472.6539 kN
2021-05-07 20:15:49 - Osdag - INFO - The horizontal shear force - 100.0 kN, is less than the shear resistance of the base plate
2021-05-07 20:15:49 - Osdag - INFO - Shear key is not required
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt Length] The length of the anchor bolt is computed assuming the anchor bolt is
casted in-situ during the erection of the column.
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt Length] The recommended range for the length of the anchor bolt of thread size 20
mm is as follows:
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt Length] Minimum length = 200 mm, Maximum length = 800 mm.
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt Length] The provided length of the anchor bolt is 379.5 mm
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt] Designer/Erector should provide adequate anchorage depending on the availability
of standard lengths and sizes, satisfying the recommended range
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt Length] Reference: IS 5624:1993, Table 1
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt Length] The recommended range for the length of the anchor bolt of thread size 20
mm is as follows:
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt Length] Minimum length = 200 mm, Maximum length = 800 mm.
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt Length] The provided length of the anchor bolt is 374.5 mm
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt] Designer/Erector should provide adequate anchorage depending on the availability
of standard lengths and sizes, satisfying the recommended range
2021-05-07 20:15:49 - Osdag - INFO - [Anchor Bolt Length] Reference: IS 5624:1993, Table 1
2021-05-07 20:15:49 - Osdag - WARNING - [Shear Check - Stiffener] The stiffener along the flange fails the shear check
2021-05-07 20:15:49 - Osdag - WARNING - The shear demand on the stiffener (219.75 kN) exceeds 60% of it’s capacity (188.95 kN)
2021-05-07 20:15:49 - Osdag - INFO - Increasing the thickness of the stiffener and re-checking against shear demand
2021-05-07 20:15:49 - Osdag - WARNING - [Shear Check - Stiffener] The stiffener along the web fails the shear check
2021-05-07 20:15:49 - Osdag - WARNING - The shear demand on the stiffener (310.46 kN) exceeds 60% of it’s capacity (153.05 kN)
2021-05-07 20:15:49 - Osdag - INFO - Increasing the thickness of the stiffener and re-checking against shear demand
2021-05-07 20:15:49 - Osdag - INFO - : =========== Design Status =============
2021-05-07 20:15:49 - Osdag - INFO - : Overall base plate connection design is SAFE
2021-05-07 20:15:49 - Osdag - INFO - : ============ End Of Design ============
Page 27