You are on page 1of 3

Name: Christian Andrew Lima Score: _____________________

Program: BSCE- 4

TIMBER SECOND FLOOR FRAMING PLAN AND DESIGN CRITERIA

TIMBER FLOOR FRAMING PLAN


SCALE 1:100
Name: Rhea Jane A. Baricuatro Given Date: June 30, 2021 1/2
Page
Program: BSCE- 5 Due Date: July 05, 2021

Instructor: Engr. John Le Carre A. Enerlan

CE523 – M_
TIMBER DESIGN
QUOTA No. 1

Title

Signature of the student: ___________________


Date signed: July 05, 2021
2/2
Page

STRUCTURAL DESIGN CRITERIA


1. Code and Standard Specification
National Structural Code of the Philippines 2010 6 th Edition
International Building Code
2. Material Specifications
Flooring 120Pa
Roofing 1.44kPa
Ceiling 240Pa
Sheathings 190Pa
Slates 290Pa
3. Loading Criteria
A. Properties of Yemane Wood at 63% Stress Grade:
Bending and Tension Parallel to (graph) grain 9.90MPa
Modulus of Elasticity in Bending 3.22 x 10 3MPa
Compression Parallel to Grain 6.20MPa
Compression Perpendicular to Grain 2.68MPa
Shear Parallel to Grain 1.55MPa
Relative Density 0.42
Unit weight of wood 4.12 kN/m3
B. Floor Live Load
Residential:
Basic Floor Area 1.9kPa
Exterior Balconies 2.9kPa
C. Roof Live Load
Roof Live Load 0.68kPa
D. Wind Loads
Wind Load 1.45kPa
Uplift Wind Pressure 1.24kPa
E. Allowable Deflection 1/300 of span
F. Others:
Snow Load 600Pa
Ice Load 300Pa
Allowable Concrete Bond Stress 0.52MPa
Working Stress Steel (for Composite Members)
Bending Stress 124Pa
Tensile Stress 83MPa
Shearing Stress 70MPa
Bearing Stress 140MPa

Signature of the student: ___________________