You are on page 1of 4

REPUBLIC OF CAMEROON REPUBLIQUE DU CAMEROUN

Peace – Work – Fatherland Paix – Travail – Patrie


MINISTRY OF HIGHER EDUCATION MINISTERE DE L’ENSEIGNEMENT SUPERIEUR
THE UNIVERSITY OF BAMENDA L’UNIVERSITÉ DE BAMENDA
National Higher Polytechnic Institute Ecole Nationale Supérieure Polytechnique
(School of Engineering) (Ecole d’Ingénieurs)
Box 39 Bambili, CAMEROON Box 39 Bambili, CAMEROUN
Tel.: 237 74946524 Fax: 237 33 05 10 69 Tel.: 237 74946524 Fax: 237 33 05 10 69

Department of Civil Engineering and Architecture

BUILDING PROJECT

SAMPLE CALCULATION HYPOTHESIS FOR A BUILDING STRUCTURE

SUMMARY

CHAPTER 1: CALCULATION HYPOTHESIS

1.1: REGULATION OF CALCULATIONS

1.2: BASIC CALCULATION INFORMATION

1.3: LOADS EVALUATION ON THE BUILDING

1.4: GENERAL CONSIDERATIONS

CHAPTER 1: CALCULATION HYPOTHESIS

1.1: REGULATION OF CALCULATIONS

CALCULATION REGULATIONS

Reinforced concrete BAEL 91 Mod. 99

Permanent loads NF P06 - 004

Exploitation Loads NF P06 - 001

Foundation DTU 13.12

Wind NF-EN 1991

Wood NF-EN 1995-1 :2006/NA:2007

Carrying elements Condition of no fragility

Spacing of reinforcement stirrups Caquot Series

1
1.2: BASIC CALCULATION INFORMATION

Object Application Theme Data

- Specific density of elements in 2500kg/m3


reinforced concrete
- Wood (softness): (3x12)cm2 and 0.7g/cm3
(8+4) cm2

Roofing in Aluminium sheets (bac 7/10) 3daN/m2

Ceiling (4mm) 2.5daN/m2

Actions Permanent Knockings (Support of ceiling) 3daN/m2


loads
Surface load of charpente 60daN/m2

Damp water proof multilayer 2cm 12daN/m2

Decking chape in concrete of thickness 1cm 23daN/m2

Wall in hollow blocks of (15x20x40) cm 208daN/m2 including


plastering

Wall in hollow blocks of (10x20x40) cm 166daN/m2 including


plastering

Tiles ceramic grey and assimilated faience 22daN/m


1cm

Exploitation Maintenance loads of the roof 1KN=100daN


loads applied at 2/3 and
1/3 of the span

Material Concrete Specific Compressive strength in 25MPa


s compression at 28days (fc28)

Specific Compressive strength in traction at 2.10MPa


28days (fc28)

Steel η=1.6; ψ s =1.5HA FeE400HA

η=1; ψ s =1RL FeE235RL

γb 1.5

Fissuration Peu prejudiciable

Soil Admissible load of the soil qu: 0.2MPa

2
Wood Softness category II with 15% humidity σ F =157 daN /cm2

Ch = 1.2

1.3: LOADS EVALUATION ON THE BUILDING

1.4: GENERAL CONSIDERATIONS

- The evaluation of loads is done using the computer aided design program (ROBOT
STRUCTURAL ANALYSIS) Version 2011
- Basic calculation hypothesis used are given above
- The charpente of the different blocks are assimilated to a decking to which we have applied a
surface load of charpente in wood, knockings and covering included
- The separation walls are plastered on both sides with cement mortar
- The dockings are desolidified to the chaining beams thus it does not contribute to the stability
of the structure
- The elevation walls are plastered with cement mortar

Load calculation parameters

Building characteristics

Soil level 0m

Foundation depth w.r.t RDC -1.80m

Height of story 3.20m

Chaining 12.80m

Soil characteristics

Admissible bearing capacity of soil at (SLS) 0.12MPa

Materials

Fe, MPa

Fc28,MPa Longitudinal Transversal Density, T/m3 Elastic modulus , T/m3

Pillars 25 400 235 2.54925 3e+006

Beams 25 400 235 2.54925 3e+006

Deckings 25 400 400 2.54925 3e+006

Footings 25 400 400 2.54925 3e+006

3
Other Materials

Materials for walls

Number Name Thickness ,m Weight Solidity, Modulus of Price,


T/m2 T/m2 elasticity euro/m2
T/m2

1 Agglos of 15T1 0.15 0.223314 400 3e+006 3


(wall plastered on
two sides )

2 Agglos of 15T2 0.2 0.326304 400 3e+006 45


covered with
shaped stones
‘pierre’ )

3 Agglos of 10T3 0.1 0.209039 400 3e+006 345


covered with tiles )

4 Acrotere 0.1 0.254925 509.85 3.0591 56