Professional Documents
Culture Documents
PLATE HEAT EXCHANGER - compact solution and the most economical type for liquid
Heat transfer coefficients each side - liquid up to 20.000 W/m²K, gas up to 500 W/m²K
Quite sensitive to high temperatures, high pressures, pressure variations. Not good for gas/air
Option 1: Plate Heat Exchanger (PHE) Overall Height/Width/Length : 1.5 / 0.7 / 5.5 m
Liquid (1) or Gas (2) Fluid 1: 1 Plate Width mm 727
Fluid 2: 1 Plate Height mm 1,409
Platestack Depth mm 5,366
Plate quantity pcs. 1,339
Extra heat Surface to achieve a moderate pressure drop : % 100
Very often the max. allowable pressure drop will determine the size of a PHE. Extra surface easily becomes 100 %.
Option 2 : Shell & Tube Heat Exchanger Overall Height/Width/Length : 4.3 / 3.6 / 1.4 m
Outer Diameter, Tube mm 18 Total tube length m 13,240.3
Wall Thickness, Tube mm 1.5 Tube pitch mm 23
Length each tube m 1.1 Number of tubes stk. 12,037
Distance tube-to-tube mm 5 Cross sect. area, Tube m² 2.1270
Diameter, Shell mm 3,534
Length, Shell mm 1100
AB&CO · TT BOILERS · P.O.Box 178 · DK-3450 Allerød · Tel. +45 4817 7599 · Fax +45 4817 7699 · E-mail: ttboilers@abco.dk