Professional Documents
Culture Documents
Comments Exceptions
Links are to Current Saudi Aramco Standards
Page 1 of 2
Saudi Aramco 2616-ENG (11/2010)
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
where
AS-BUILT
10-01433-7675
01
Pipeline MAOP 2550 PSI MAOP for API 3000# valve@ 300 oF = 2550 PSI
t = Tn - C = 0.373
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)
Minumum Test Pressure 3825 PSI Minimum test pressure = 1.5 XPipeline MAOP
Flange test pressure = 6000 PSI Flange test pressure = Per API 6A Table 31
CONST. AGENCY/DATE
Valve test pressure = 6000 PSI Valve test pressure = Per API 6A Table 31
2 X 0.9 X S X Tn
06/16/21
Pipe wall test Pressure = 19827 PSI Pipe wall test Pressure = SAES-L-150
MAJ
D
Line test pressure = 6000 PSI Line test pressure = The grater value of the following :
1. Minimum test pressure of (pipe wall, flange, valve)
✘ Limited By Flange test pressure 2. Minimum test pressure (SAES-L-150)
CERTIFIED/DATE
Sytem 1
AMA
DESIGN CERTIFICATION
Pipeline MAOP = 2550 Pipeline MAOP = lesser value of the MAOP for each line
(DESIGN AGENCY)
Safety Valve Set Pressure for Strength T 6300 Safety Valve Set Pressure for Strength Test =
(1.05 X Test Pressure)
Entry # 38 & 39 - Minimum Wall Thickness @ System MAOP
REVISION VALIDATION
10-01433-7675-006
SIS FOR 2"-BD-0112-90CS1T DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.