Aspen Exchanger Design and Rating Air Cooled V12

File: C:\..\..\..\..\T1-235 T2-118 CON 219 TUBOS, DOS PASES, AIRE MEDIDA Printed: 29/7/2021 at 01:14:44
VENT. LB.HR v1.EDR

Heat Transfer Coefficients

Film coefficients BTU/(h-ft²-F) Outside Tube Side


Overall film coefficients 97,41 110,82
Mulitple phase coefficients
Vapor sensible 97,41 109,02
Two phase 120,72
Liquid sensible
Heat Transfer Parameters In Out In Out
Prandtl numbers Vapor 0,7 0,7 0,78 0,8
Liquid 3,89
Reynolds numbers Vapor (Diameter) 4292,96 4114,98 218903,9 251178,7
Liquid (Diameter) 3,32
Reynolds numbers Vapor (Hydraulic) 856,28 820,78
Liquid (Hydraulic)

Fin Efficiency 0,94