You are on page 1of 29

All-in-One

Micro Data Center

Instant Edge

IEM-02T All-in-One Micro Data Center

PRODUCT PRESENTATION
Why Edge Computing

Public Cloud Hybrid Cloud Edge computing


Latency caused by distance Local data computing All data are processed in
and processing User’s location
High cost for tenant
Sensitive data stored Physical guard to private data
Data safety and privacy concern
locally
Micro Data Center: edge computing infrastructure

Close to data user Simple construction


Low Latency Low investment

Prefabrication Azure Google


Physical protection
Fast Deployment Of privacy

AWS Apple

Data User The Edge Computing Hyper-Scale Cloud


IEM Edge Micro Data Center
Space saving

High Mobility

Instant Deployment Out-of-Box

Instant operation

Instant Expansion
IEM02T All-in-One MDC All-in-One Topology

Free of outdoor unit installation

High protection enclosure

With CCTV and access control

Standard one Rack footprint

For space-tight office scenario

Plug-and-Play for installation

Out-of-Box, less labour cost


Leverage best patterns & practices here
➔ www.iewatt.com
OVERVIEW

8
1 A/C 2 Intelligent Power Distribution
8
5 6
10
3 UPS 4 2U Lithum Battery pack
9

5 DCIM Monitor 6 Access Control

7
7 Front Door Glass 8 Intelligent PDU 2

3
9 17U Empty Space for IT
10
24U Cabinet
4
OUTLINE DRAWING
INTERIOR LAYOUT

9U Precision Cooling

16U IT Space
24U Rack

3U PDM
2U UPS UPS

2U Lithum Battery Battery


DATA SHEET

1. Power input: 208V~240V;50/60HZ.


2. Available Space: 24U Empty Cabinet ; 17 available U space For IT
3. Overall Dimension: 600mm(W) * 1200mm(D) * 1590mm(H);
4. UPS: 2kVA/2KW online high frequency with 30mins backup battery pack
5. PDU: 16A input@230V1P, 3*C19(230V 1P) + 9*C13 sockets.
6. Cooling: 2.5kKW DX type, Top cooling system with indoor and outdoor Integrated;
7. Smart Power Distribution: 3U with internal intelligent controlling core; all-rounded monitoring
and fully isolation between DC and AC; with network port for communication.
9. Monitoring: local display and management of temperature, smoke, door, UPS, power, and cooling.
Supports remote view by web-browser. Supports Modbus-TCP/SNMP protocol integration.
10. Security: 3 in 1 access control. (Pin/RFID/Fingerprint)
Critical Particle: Cabinet

Robust:
21-edge frame sheet metal; high duty hinge,
make the cabinet load capacity up to 1800kg

Efficient:
Close cabinet system With Hot and cold
Aisle inside, isolated from outside,
streamlined air circulation

Well Organized:
Vertical and horizonal cable fastening
Channel for cable organizing
Critical Particle: Thermal System

SMART & COOL

Smart Top-Mounted Cooling

Compact Design with all-in-one layout

No outdoor unit and free pipe connection

Optimal Air Circulation for high efficiency


Critical Particle: Precision Cooling 1
6
2

5
3
Industry top brand Packaged design easy
1 compressor. Highly reliable 4 for installation, service
and efficient. and shipping.

Precision cooling controller Top mount means good air


monitors and protects unit management of hot/cold
2 constantly. Easy to be integrated 5 stream and no occupying
into BMS to display, control and of IT space.
manage the system.

Compatible with standard Green refrigerant is


3 rack size forms unified and 6 highly efficient and
integrated mdc solution. no ODP.

Air Circulation
Cooling Specs

Model IEcool-02R

Total Cooling-kW 2.5


Notes: SHR-% 100

1. Cooling capacity based on Air Volume-m3/h 500


37℃/24%RH return air and
35℃ outdoor air. Mount Type Bottom

2. Options including monitoring Cooling Type DX


card, condensate evaporation
kit. Height-mm 390

3. The frequency 50Hz or 60Hz is


Depth-mm 1100
optional upon order. Width-mm 600
4. Customized design is Weight-kg 50
negotiable.
Power Input1) 220V/50Hz/60Hz/1Ph
5. The right reserved to change
parameters without prior
notification. FLA-A1) 5.5

Power Input2) 208-240V/50Hz/60Hz/2Ph

FLA-A2) 5.5
Critical System : Power System

UPS System:
Capacity :3KVA~10KVA
Rack mounted Installation
Lithum Battery pack
Slim-size and Powerful

Intelligent Power Distribution:

Smart built-in smart core


Versatile and Intelligent

PDU:

Intelligent PDU to detect every


Amper and Volt inside data center
Critical Particle : Lithum battery UPS

The standard 19” rack mount design makes it easy to install in


a variety of racks, slim-size battery backup time for space-tight
condition in micro data center, especially for the long backup
time in single rack

▪ Online double-conversion UPS

▪ VRLA /Lithium battery optional

▪ Powerful network management function, SNMP communication


with DCIM system
No. Item Specs

1 Rated Capacity 3kVA /2.7kw


2 Max charging current 14A

3 Phase Single
4 Input PF(full load) > 0.99

5 Input frequency 50Hz/60Hz;


40Hz~70Hz
6 THDi < 5%

UPS Specifications 7 Output Voltage 220V/230V/240V, range:±1%

8 Output frequency Online Mode:50/60Hz±6Hz;


Battery Mode:50/60Hz±0.05%

9 Output power factor 0.8

10 Efficieny 95%
11 Communication port RS232
Optional for SNMP/RS485/Dry contact

12 Dimension(W×D×H) 430mm×440mm×88mm/2U

13 Weight 10.5 kg
14 Noise < 50dB
Critical Particle: Intelligent PDM

PDM( Power Distribution Module) is a rack mount type power


management and distribution system, with built in smart control core
This module is multi-functional and versatile:

▪ Built-in controlling board

▪ With DC/AC Isolation

▪ Dection and sampling module for all parameter monitoring

▪ SNMP/Modbus communication

▪ With dual bus design for redundancy, protect all electrical device

SNMP Smart port


RS485 Smart port
No, Item 32A Capacity
1 AC input breaker 32A/2P

2 Phase N Single

3 Input frequency 50Hz/60Hz

4 Input voltage 220V/230V/240V

2 Surge protection capacity C Level:20KA/2P(L+N)

3 Surge breaker 25A/2P

4 Manual breaker 32A/2P

5 UPS Input breaker 16A/1P

Power Distribution Specs 6 UPS output breaker 16A/1P

7 PDU1 16A/1P

8 PDU2 16A/1P

9 Branch breaker 2×16A/1P+3×10A/1P

10 Operational attitude 4000m

11 Operational temp -5℃~40℃

12 Operational Hum 5%~95%

13 Storage and transportation 40℃~70℃

14 Dimension mm(W×D×H) 440×540×132mm/3U


Critical Particle: Intelligent PDU IESlim Intelligent PDU and STS Gallery

IESlim Intelligent PDU is specific for easy data


center management ,with the function of electricity
detection and controlling, its built-in data collector
function make is can also work as the auxiliary
monitoring hub in the each single rack: Connect the
temp&hum sensor and collect all the data then
delivery to DCIM system.

▪ Support rack-mounted and vertical-mounted in cabinet;

▪ Each port remotely controlled for on/Off

▪ Support HTTP TSL1.0 and SNMPv3 encryption

▪ All ports employ the electrical isolation for safety;

▪ SNMP platform for easy integration and management

▪ Latest Linux 4.0 version; fix vunlurability and safety flaw

▪ With digital port for environment sensors connection


PDU Specifications

▪ PDU Mounting Type:Vertical or Horizonal

▪ Intelligent function:

▪ Chief moniotoring(Only monitoring the main parameters)


Chief monitoring and branch monitoring
Chief and branch monitoring and controlling
Item Port Description Item Port Description

1 8 pcs10A C13(optional) 9 Page down/up button


▪ Input/output:Single or three phase 2 Indicator LED 10 Reset button

3 LCD digital screen 11 Communication Indicator

▪ Input current:16A/32A; 4 NET 10/100M network port 12 hanger

5 Input 485 port 13 Input breaker 16A/1P(optional)

▪ Outlet quantity:8/16/24(customizable for 20/26/30) 6 Output 485 port 14 PDU input port IEC-C19

7 IO Port 15 Input with IEC-309 connector or IEC-C20

8 SENSOR port(for temp and hum sensor)


Critical Particle: Intelligent PDU
IT Rack with sensors distributed
inside for single rack
environment detection

More than a electrical Socket

Intelligent PDU can also work as


the auxiliary monitoring hub in IT
rack for environment sensor
connection Environment sensors
connection port
Critical Particle : IESmart DCIM

SNMP
Critical Particle : IESmart DCIM

Specifications

No. Item Parameter

1 ◆1 AC input
Power Input ◆operational voltage:100V AC~240V AC
◆Rated frequency:50Hz/60Hz
◆Input current:MAX0.5A
Local 10’’ Touch screen Interface Wireless access via mobile devices
2 System High speed CPU,64M internal memory,SD card scalable
infomation

3 Network 1 x LAN port,10/100M rate,scalable WIFI。


port

4 RS485/232 Optional 4 way RS485/232 port,max supporting 115200bps.Port


serial port isolatedSupporting MODBUS expansion(like cooling; UPS;
expansion sensors)。
5 OUT1-4 14 x dry contact output.3A/30VAC ,1A/125VAC
6 CANBUS Canbus input
chief cable

7 Temp&hum 2x IIC digital temp sensor port (1)Power input C14 (2)IN1-8 Input level detection
sensor port
(3)OUT1-4 Dry contact (4)TH1/2 digital temp&hum sensor
8 USB port 4xUSB port for external device powering;12A max
(5)4x RS485/232 port (6)CANBUS port
(7)Network port (8)SD card port
(9)USB Device powering port (10)Indicator
(11) hanger
Power:DC12V
Humidity : 0%RH~100%RH
Critical Particle : Environment Monitoring Temperature range:0℃~50℃
Humidity accuracy:±3%RH(5%RH~95%RH,25℃)
Temperature Accuracy:±0.5℃(0℃~50℃)
Working conditon:-10℃~60℃;0%RH~100%RH\)
Stability of Hum:<1%RH/y
Stability of Temp:<0.1℃/y
Response time:<15s(1m/s )
Output Port:RS485
Temp&Hum Sensor

Power:9V Battery/DC12V
Working Condition:-5~50℃, 10-90%
The Environment sensors are widely spread in each Beep Noise:85dBa 10 feet away
Diameter:105mm
cabinet to do the real-time detection of the Working Current:Static Less 10uA,
environment status, including temperature, humidity; Alarm Current:10-30mA
Output :Dry Contact
smoke ;water leakage and door status
Smoke Sensor
Power:DC 24V(9V~32V)
Temperature:0℃~50℃
Humidity:20%RH~100%RH
False alarm Ratio:<100ppm
Power Consumption:0.5W
Alarm Power Consumption:1.2W
Output Method:Relay(Load current 100mA)

Water Leakage Sensor

Power:DC 24V(9V~32V)
Max Power:10W
High Voltage:100Vdc
Max current: 0.5A

Door Sensors
Centralized Monitoring platform
Mobile Devices Remote Site

ModBus/Dry contact
Critical Particle: Access Control
No Item Description
1 Operational voltage DC12V

2 Static current ≤35mA

3 Reading Distance 3-6 CM

4 Internal memory 300 finger print./card 10000 user

5 Short-circuit Time≤100
protection
6 Temperature -40-60℃
ID 7 Humidity 0-95%
8 Access Methods Biometric、Card、Pin

Linkage with DCIM system and equipped with IP55 9 Alarm Output ≤20A
high protection 3-in-one door reader, the access
control system are available for remote control; 10 Card management Adding or delete card
authority management and security in the DCIM
system, make you free of the privacy and safety
concern
Critical Particle: Fire Suppression
The rack mount fire extinguisher is design to protect
critical electrical IT components within the cabinets. Built in
with the FM200 gas, releasing valves, activation sensors and
controllers, the compact system is ideal for the micro
modular data center applications.

Rack Mounted Installation Momentary Gas Occupation

Sensitive Environment detect Plug-and-Play easy installation

Battery Backup for system Green Gas For People


What we Export: Simplicity

Simply the Design

Simply the Installation

Simply the Deployment


THANKS FOR WATCHING

IEWATT TECHNOLOGY CO.,LTD

Add:
UNIT 04,7/F BRIGHT WAY TOWER NO33 MONG KOK RD
KL.HONGKONG

Web:http://www.iewatt.com

Email: iewatt@iewatt.com

You might also like