You are on page 1of 3

SLAB TYPE RECTANGULAR COMBINED FOOTING FOR CF3 AT GRID D(2-3)

INPUT DATA
1) LOAD ON COLUMN ON A = 696 KN
2)LOAD ON COLUMN ON B = 380 KN
3)CENTRE TO CENTRE DIST. (L3) = 2.30 m
4)DIST. OF CENTRE OF COLUMN A
FROM PROPERTY LINE (L1) = 1.29 m
5)DIST. OF CENTRE OF COL. B = 0.2 m
5)SIZE OF COLUMN A
d1 = 304 mm
b1 = 304 mm
6)SIZE OF COLUMN B
d2 = 304 mm
b2 = 304 mm
7) BEARING CAPACITY OF SOIL = 100 KN/mm2
8)STRENGTH OF CONCRETE fck = 20 N/mm2
9)STRENGTH OF STEEL fy = 500 N/mm2
10)WIDTH OF PEDESTRAL = 0 mm

LENGTH OF FOOTING = 3.79 m


WIDTH OF FOOTING = 2.6 m

P1 = 696 Kn P2 = 380 Kn

A B

L1 = 1.29 m L3= 2.3 M L2 = 0.2 m

3.79

1.895

DESIGN :-
LENGTH AND WIDTH OF FOOTING:-

C.G. OF LOADS FROM PROPERTY LINE X = 2.44 m

WT. OF FOOTING & EARTH ABOVE (10%) = 69.6 KN

TOTAL LOAD ON EARTH = 696 + 380 + 69.6 = 1145.6 KN

FACTORED LOAD ON COL. A = 1.5 x 696 = 1044 KN


FACTORED LOAD ON COL. A = 1.5 x 380 = 570 KN
NET UPWARD SOIL PRESSURE = (1044 + 570) / (3.79 x 2.6) =

= 164 KN/m2

NET UPWARD SOIL PRESSURE PER UNIT LENGTH = 164 x 2.6 =

= 426.4 KN/m

B/2
C1 b1 C2
b2
B/2 d d2

L1 L2 L3

1044 / 0.304 = 570 / 0.304 =


3434.22 KN/m. 1875 KN/m.

426.4 KN/m

A B C D E F G H J

FACTORED SHEAR FORCE AT FOLLOWING POINTS:-

B= 426.4 x (1.29-0.152) = 485.2432 KN

DLEFT = 426.4 x 1.442 - 3434.22 x 0.304 = -429.132 KN

DRIGHT = -1 x -429.132 = 429.132 KN

F= -429.132 + 426.4 x 1.996 = 421.9624 KN

HLEFT = 421.9624 - 1875 x 0.304 + 426.4 x 0.304 = -18.412 KN

HRIGHT = -1 x -18.412 = 18.412 KN

SHEAR FORCE CHANGES SIGN AT C (BC) = 0.1614 m.

SHEAR FORCE CHANGES SIGN AT E (DE) = 0.8532 m.

SHEAR FORCE CHANGES SIGN AT G (FG) = 0.2913 m.

THE DISTANCE OF FOLLOWING POINTS FROM LEFT EDGE,m

B= 1.138 AB = 1.138
C= 1.2994 BC = 0.1614
D= 1.442 CD = 0.2913
E= 2.2952 DE = 0.8532
F= 3.438 EF = 1.1428
G= 3.7293 FG = 0.2913
H= 3.742 GH = 0.0127
BENDING MOMENT AT VARIOUS POINTS :-
(NEGATIVE SIGN INDIACATES HOGGING MOMENTS)

B= 276.103381 KN-m B (ABS) = 276.103

C= 315.244961 KN-m C (ABS) = 315.245

D= 284.632405 KN-m D (ABS) = 284.632

E= 73.6966561 KN-m E (ABS) = 73.697

F= 277.478741 KN-m F (ABS) = 277.479

G= 338.92862 KN-m G (ABS) = 338.929

H= 0.4912128 KN-m H (ABS) = 0.491

MAXI. DESIGN MOMENT,Mumax = 338.929 KN-m

REQUIRED THICKNESS FOR FOOTING,


WIDTH OF FOOTING b = 2600
2
Mumax = 0.138 fck b d
338.929 = 0.138 x 20 x 2600 x d^2

HENCE d= 300 mm.


CONSIDER EFFECTIVE COVER = 50 mm

OVERALL DEPTH D = 350 mm

MAIN NEGATIVE LONG. REINFORCEMENT (HOGGING MOMENTS):-

Ast= 0.5fck [1-sqrt(1-4.6 BM ) ] * b*d


fy fck*b*d

2
Ast = 2860.75849 mm % pt = 0.37

MINI.Ast = 0.85 x 2600 x 300 / 500

2
Ast (min) = 1326 mm % pt = 0.17

HENCE Ast PROVIDED = 2860.75849 mm2

BAR DIA. AREA Ast reqd. BAR BAR PROVIDE SPACING UNIT WT TOTAL
(mm) (mm2) (mm2) REQD. PROVIDE Ast (mm2) (mm) c/c Kg/m WT. (kg)
12 113.1 2860.75849 25.3 26 2940.6 103 0.889 53.17

HENCE PROVIDE # 26 - 12 mm BAR ( SPACING = 103 mm c/c )

MAIN NEGATIVE LONG. REINFORCEMENT (SAGGING MOMENTS):-

DESIGN MOMENT UNDER COLUMN A / COLUMN B = 284.632 KN-m

Ast = 2360.819 mm2

Ast min = 1326 mm2

HENCE Ast PROVIDED = 2360.819 mm2

BAR DIA. AREA Ast reqd. BAR BAR PROVIDE SPACING UNIT WT TOTAL
(mm) (mm2) (mm2) REQD. PROVIDE Ast (mm2) (mm) c/c Kg/m WT. (kg)
12 113.1 2360.819 20.88 21 2375.1 125 0.889 42.94

HENCE PROVIDE # 21 - 12 mm BAR ( SPACING = 125 mm c/c )

You might also like