You are on page 1of 3

Architectural

The items on Building lot


Ground
Site
Passageways in the site for emergency evacuation
Fence Foundation
Masonry work
Retaining wall
Foundation, prime structural members and items on elevations
Foundation
RC columns
SS columns
Wooden columns
RC girders and beams
SS girders and beams
Wooden girders and beams
RC or other bearing walls
RC braces
SS braces
RC floor slabs
RC roof slabs
SS roof support structure
Exterior wall Masonry work
Other structural members
Exterior finishing material, etc.
Sign boards, outdoor units of A/Cs, etc. attached to the exterior wall
Windows Sashes/frames
Gaskets
Windowpane
Doors
Projections Structural parts (balconies, eaves, protruding rooms)
Fixtures (handrails, brackets for A/C outdoor units, etc.)
Roof
Flat roof
Circumference of the flat roof
Pitched roof
Equipment and fixtures (cooling towers and sign towers, etc.)
Interior
Walls facing to the interior space Masonry work
Other structure
Finish
Windows Sashes/frames
Gaskets
Windowpane
Floors Structure, etc.
Ceilings Finish
Lightings and hanging items, etc.
Evacuation facilities, etc.
Passageways
Doorways
Stairs Handrails
Steps, landings, etc.
Evacuation
Evacuation Ladders
Smoke exhaust equipment /assembly Smoke exhaust equipment
Others
Particular structures, etc. Membrane members and the fittings parts of membrane structure
Seismic base isolation equipment and the trench
Lightning protection system
Chimneys Chimneys for building service
Other chimneys
Ventilation
Habitable rooms installed with ventilation equipment
(excluding kitchens, etc.)
Mechanical driven ventilation equipment Appearance of the equipment
Performance (including centrally controlled HVAC system)
Centrally controlled HVAC system Capital equipment and appearance of piping
Kitchen, etc. required to be installed with ventilation equipment
Passive ventilation system or mechanical driven ventilation equipment
Mechanical driven ventilation equipment
Habitable rooms installed with ventilation equipment
Fire dampers, etc.
Smoke exhaust
General

Smoke exhaust fans Appearance


Performance
Others Appearance of smoke vents for mechanical smoke exhaust system
Performance of smoke vents for mechanical smoke exhaust system
Ducts for mechanical smoke exhaust system (excluding concealed parts)
Fire dampers
Emergency power
Emergency generator Appearance
Performance
Engines directly coupled with smoke exhaust Appearance
fans Performance
Emergency Lighting
Lighting equipment
Emergency lighting equipment
Standby battery (built-in or not built-in) and emergency generator
Standby batteries
Standby battery (not built-in) and emergency generator
Changeover circuit
Standby battery (built-in)
Wiring and pilot lamp for charging
Standby battery (not built-in)
Standby battery Appearance of the battery room
Capacity
Charger
Sanitary
Water supply and drainage equipment
Water supply and drainage piping(excluding concealed parts)
Quality of water
Water supply equipment
Reservoir tanks and supply pumps
Boilers (including circulation pumps)
Drainage equipment
Sump pits
Waste water recycle system
Others Sanitary fixtures
Drainage traps
Interceptors for grease, hair, and so on
Drainage
Electrical
Wiring, etc. Outlet/wiring/switch
Wall plates for switch and outlet
Circuit Breaker
Circuit Breaker /distribution board
wiring
Building management system / integrated instrument
Emergency generator Appearance
Performance
Elevators and escalators
Elevators Sill grooves
Doors and interior condition
Whole
Maintenance records
Escalators Steps, landing, handrails
Whole
Maintenance records
Fire fighting equipment
Fire fighting equipment Fire extinguishers
Sprinkler
Hydrant
Others
LPG gas cylinders Location
LPG gas Cylinders
Piping

You might also like