You are on page 1of 4

14.500 780.68 14.500 780.

68
11,500kW
405.0 48.70 405.0 48.50

HP Steam 14.500 780.68

405.0 0.198
G

Sealing Steam

0.200 599.11

59.65 69.00

2.500 677.74

185.0 20.50
LP Steam

Ejector steam

14.500 780.68

405.0 0.400

SJAE

Air T = 45°C

0.187 58.25
3.000 32.07
58.28 69.60
32.00 0.004

Make up

12.000 58.60

58.40 69.60

11.5 00 62.63
p [ata] h [kcal/kg]
62.44 69.60
t [°C] m [t/h]
1 ata = 1 kg/cm2(a) = 0.980665 bar(a) = 735.56 mm of Hg
D:\Projects_Chirayu\SST200_300\RCCPL\WHR\var01\KGRAPH01.kgr

Prepared: 29.03.2019 Prepared by: Chirayu Title: Pages:


Revision: Heat balance diagram 4
Revision Responsible
index: department: PG SC Loadpoint 1 // PG Case
Pg. no.:
Project: RCCPL
1
Enquiry
DrawingNo:
No:
14.500 780.68 14.500 780.68
2,550 kW
405.0 14.75 405.0 14.55

HP Steam 14.500 780.68

405.0 0.198
G

Sealing Steam

0.127 624.34

61.50 20.70

2.500 677.74

185.0 6.149
LP Steam

Ejector steam

14.500 780.68

405.0 0.400

SJAE

Air T = 45°C

0.122 49.36
3.000 32.07
49.38 21.30
32.00 0.004

Make up

12.000 49.72

49.50 21.30

11.5 00 63.06
p [ata] h [kcal/kg]
62.87 21.30
t [°C] m [t/h]
1 ata = 1 kg/cm2(a) = 0.980665 bar(a) = 735.56 mm of Hg
D:\Projects_Chirayu\SST200_300\RCCPL\WHR\var01\KGRAPH01.kgr

Prepared: 29.03.2019 Prepared by: Chirayu Title: Pages:


Revision: Heat balance diagram 4
Revision Responsible
index: department: PG SC Loadpoint 2 // 30% Load
Pg. no.:
Project: RCCPL
2
Enquiry
DrawingNo:
No:
14.500 780.68 14.500 780.68
5,100 kW
405.0 24.45 405.0 24.25

HP Steam 14.500 780.68

405.0 0.198
G

Sealing Steam

0.146 611 .01

53.03 34.50

2.500 677.74

185.0 10.25
LP Steam

Ejector steam

14.500 780.68

405.0 0.400

SJAE

Air T = 45°C

0.139 52.02
3.000 32.07
52.04 35.10
32.00 0.004

Make up

12.000 52.37

52.15 35.10

11.5 00 60.44
p [ata] h [kcal/kg]
60.24 35.10
t [°C] m [t/h]
1 ata = 1 kg/cm2(a) = 0.980665 bar(a) = 735.56 mm of Hg
D:\Projects_Chirayu\SST200_300\RCCPL\WHR\var01\KGRAPH01.kgr

Prepared: 29.03.2019 Prepared by: Chirayu Title: Pages:


Revision: Heat balance diagram 4
Revision Responsible
index: department: PG SC Loadpoint 3 // 50% Flow
Pg. no.:
Project: RCCPL
3
Enquiry
DrawingNo:
No:
14.500 780.68 14.500 780.68
12,700 kW
405.0 53.55 405.0 53.35

HP Steam 14.500 780.68

405.0 0.198
G

Sealing Steam

0.215 598.58

61.20 75.90

2.500 677.74

185.0 22.55
LP Steam

Ejector steam

14.500 780.68

405.0 0.400

SJAE

Air T = 45°C

0.201 59.76
3.000 32.07
59.79 76.50
32.00 0.004

Make up

12.000 60.12

59.91 76.50

11.5 00 63.78
p [ata] h [kcal/kg]
63.59 76.50
t [°C] m [t/h]
1 ata = 1 kg/cm2(a) = 0.980665 bar(a) = 735.56 mm of Hg
D:\Projects_Chirayu\SST200_300\RCCPL\WHR\var01\KGRAPH01.kgr

Prepared: 29.03.2019 Prepared by: Chirayu Title: Pages:


Revision: Heat balance diagram 4
Revision Responsible
index: department: PG SC Loadpoint 4 // VWO
Pg. no.:
Project: RCCPL
4
Enquiry
DrawingNo:
No: