Professional Documents
Culture Documents
Contents
2.ARCHITECTURE ........................................................................................................................................... 4
2.1Facade System..................................................................................................................................... 5
2.1.1. Curtain wall façade, façade system and glazing............................................................... 5
2.1.2. Prefab colored concrete .......................................................................................................... 8
2.2 Internal wall ......................................................................................................................................11
2.3 SURFACE FINISH...............................................................................................................................31
2.3.1FLOOR FINISH ............................................................................................................................31
2.3.2 WALL FINISH .............................................................................................................................51
2.3 CEILING FINISH ...............................................................................................................................53
2.4 SKYLIGHT ..........................................................................................................................................75
2.4 TRANSPORT SYSTEM.......................................................................................................................77
2.4.1 LIFT ..............................................................................................................................................77
2.4.2 ESCALATORS .............................................................................................................................81
2.4.3 STAIRCASES ...............................................................................................................................84
2.5 SANITARY FIXTURES ........................................................................................................................88
2.5.1 WASHING BASIN .....................................................................................................................88
2.5.2 TAP ..............................................................................................................................................89
2.5.3 TOILET PANS (VitrA Fresh M line)..........................................................................................89
2.5.4. URINAL.......................................................................................................................................90
2.5.5. SEPARATORS ceramic(Laufen)Rion, urinal division ............................................................91
2.5.6 ACCESSORIES (stainless steel) (Franke) ...............................................................................91
2.5.7. SHOWER ...................................................................................................................................95
2.5.8.ACCESSIBLE SANITARY FIXTURES (VitraDOC-M PACK) ...................................................98
2.5.9 GEBERIT ......................................................................................................................................99
2.6.1 EXTERIOR................................................................................................................................. 100
2.6.2 INTERIOR ................................................................................................................................. 104
2.6.2.3 Utility ........................................................................................................................................ 109
2.6.2.4 Wet Area ................................................................................................................................ 110
2.6.2.5 Sound........................................................................................................................................ 111
2.7 INTERIORS ...................................................................................................................................... 114
Book of standards - 1
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 2
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 3
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.ARCHITECTURE
Book of standards - 4
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.1Facade System
Applications
- Total building cladding.
- curtain walls,
- complex three dimensional façades and
roofs,
- opening lights and
- Curved glasses.
Features
- Flush external surface.
- Engineered to permit glazing in any plane:
vertical, horizontal or sloping.
- High quality and appearance of materials.
- Most widely tested structural glazing system.
- Can incorporate most Pilkington glass types
Book of standards - 5
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
GLAZING
Manufacturer - Pilkington
Product name- Pilkington ActivSuncool(Self-cleaning high performance solar control and
low-emissivity glass)
Description
- self-cleaning
- solar control
- dual coated glass(thermal insulation)
o surface #1 self-cleaning on-line coating with photo-
catalytic and hydrophilic properties
o surface #2 superior off-line solar control and low-
emissivity coating, with high light transmittance, high
light reflectance
- Available in clear or neutral appearances and in two
distinctive colors: blue and silver.
Applications
- As insulating glass units
- for large glazed areas
- for commercial and residential applications
- As toughened or laminated glass.
Features
- Self-cleaning
- superior solar control
- high light transmission and reflection
- Superior low-emissivity, with U-values down to 1. 0 W/m2K in 6-16-4 standard
constructions with argon (90%),
- available in 6 and 8 mm; 4 mm thickness, 10 mm is available on special request
- Maximum size of primary monolithic product is 2500 mm x 4500 mm
- harmonizing spandrel panels (if needed)
o Pilkington Spandrel Glass Coated A140
Appearance in reflection- Neutral/blue
Level of reflection – High(29%)
Product name- Pilkington ActivSuncool 40/22(Pilkington Spandrel Glass Coated A140)
Note
- Maximum size of primary monolithic
product is 6000 mm x 3210 mm.
- The primary product shall only be used
in insulating glass units.
- 16 mm (double glazed units)
Glass configuration
- triple insulating glass unit, Pilkington
Optitherm™ S3 #5
- insulating glass unit,
Pilkington Optitherm™ S3 #3
Pilkington K Glass™ #3
Primary product outside #1+2
Performance code:
Book of standards - 6
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Applications
- used wherevera colored glass without surface
coating is required
- Wherea safety glass is required, they can be
specified as toughened orlaminated glass.
Features
- Reducing the need for air-conditioning.
- Solar control performance and color density vary
with thethickness.
- Available in Green, Blue-Green, Bronze andGrey colors
- Low internal and external reflection,
- Reduce uncomfortable glarefrom the sun, and offering improved privacy compared to
clearglass.
- Reduce UV radiation.
- Can be laminated, toughened, bent and enameled using standardtechniques.
- Available from 3 mm to 10 mm thicknessdepending on the color.
- Satisfies the requirements for harmonized European Norm EN 572.
Performance code:
U value 1.0 W/m2K
Light 58
Energy 34
Light:
Book of standards - 7
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Transmittance 58
Reflectance outside 16
Reflectance inside 22
Color rendering index 88
Energy:
Direct transmittance 28
Reflectance 13
Absorptance 59
Total transmittance 34
Shortwave shading coefficient .32
Long wave shading coefficient .07
Total shading coefficient .39
S, UV
Selectivity index 1.71
UV transmittance 11
- Each element consists of a uniform and non-separable unit for a monolithic appearance.
- Individual | the modular formwork construction is done based on the Architects’
individual design.
- The color of the concrete matrix is variable.
- The characteristic appearance of concrete creates a vivid and authentic surface on the
facade.
- Intelligent assembly | Fixing anchors can be integrated during the production process
(concealed) or added with screws later on.
Technical data
Color: variable, color specification and tolerances to be defined by mock-up
Surface:visible side on one or both panel sides, other surfaces textures on requestdepending on
statics alkali-resistant
Reinforcement:grassfires and steel or stainless steel client specific defined by mock-up,
Edge formation:each fiber C 3D panel is regarded as a single piece.
Book of standards - 9
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Weather Resistance
Water impermeability Ok
Heat-rain-alternate test Ok EN 12467
Frost resistance Ok EN 12467
Frost-defrost-alternate test Ok EN 12467
UV-light resistance UV- and weatherproof color
pigments
Book of standards - 10
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
A. External cladding of Auditorium, Elevator facades, service cores & all sold
walls inside the podium
Manufacturer :FMG FABBRICA MARMI E GRANITI
Name of product: Onsernone; Polished & Bush hammered Granite;
Size 900 x 150 mm for both
Color: Dark Grey & Canadian pink(Autumn rose) for Elevator facade
Technical features:
Book of standards - 11
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
(*) = The p
0,5rding to the UNI CEN standards "fully vitrified t
B. Board room
Manufacturer :Armstrong
Name of product: MetalWorks™ Custom DH700 Flat Custom Ceiling system integrated
with WH1000 Walls(Wall-to-Ceiling 90° transition)
Material
Aluminum – thickness 0.040".
Surface Finish
Painted finishes: Factory applied polyester paint
Laminates: Vinyl-faced membrane
Fire Performance - Class A fire resistant.
Painted aluminum finishes tested per ASTM E84. Flame spread Index 25 or less. Smoke
developed Index 50 orless.
CAN/ULC S102 surface burning characteristics: Flame spread Rating 20. Smoke Developed
Classification 0.
Painted Aluminum finishes CAN/ULC S102 surface burning characteristics: Flame Spread
Rating 0. Smoke developed Classification 0.
Book of standards - 12
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Laminate finish tested per ASTM E84. Flame Spread Index75 or less. Smoke Developed
Index 450 or less.
Book of standards - 13
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
C. CEO office
Manufacturer :Armstrong
Name of product: WoodWorks™ Ekos®standard Wall Panels, size 3000 x 600 mm
perforated(for board room) &unperforated (for CEO office)
Panel Material
Mineral fiber with real wood veneers. Face veneers arequarter-cut, random-matched Anigre
or Makoreveneersstained to the Ekos finishes.
Panel Surface Finish
Tinted, no-solvent coatings on face veneers.
Accessory Material
Milled solid wood stained tocoordinate with Ekosfinishes. Extruded aluminum.
Book of standards - 14
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Wall Construction
Wall construction is one layer 5/8"drywall each side of 3-5/8" metal stud, with Ekos panels
attached onone or both sides.
Fire Performance
Class B fire performance per IBC.Flame Spread Rating of 50 or less and Smoke Developed
Classification of 100 orless when tested per ASTM E84 or CAN/ULC S102.
Book of standards - 15
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
D. Auditorium
Manufacturer
:Armstrong
Name of
product:
Book of standards - 16
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 17
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Z-clipsforpanelinstallation
Book of standards - 18
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
E. Reception
Manufacturer :Armstrong
Name of product:Soundscapes® shapes Wall panels at reception back wall
(Detail description as per the ceiling system at reception area.
See description ceiling system of entrance lobby area section -B)
Note:-
• The design shall be done in harmony with the ceiling system& coordinate with other
interior finishes.
• panels must be impact-resistant for applicationsthat need improved durability.
Book of standards - 19
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 20
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Material
PETG
Surface finish
Smooth
Fire Performance
Infusions panels according to NFPA 286are equivalent to Class A Interior finish as definedby the
International Building Code.
Book of standards - 21
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 22
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 23
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 24
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 25
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 26
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 27
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Services Services can be installed either horizontally or vertically and easily accessed for
maintenance or future alteration.
Accessories Cupboard units, ticket and sliding window units, Venetian and vertical blinds within the
sealed glass elements, picture hooks etc.
Sound insulation Double paneled partitions up to Rw 49 dB.
Fire resistance Solid paneled partitions from 30 minutes up to 60 minutes.
Integration of electrical Perforated studs provide access for wiring and other services. Demountable paneling
and data services provides easy access for installation afterwards.
Installation tolerances Floor: +/- 10 mm, Ceiling: +/- 10 mm
Book of standards - 28
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 29
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 30
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.3.1FLOOR FINISH
A. POOL OFFICES/ EXECUTIVE FLOOR/ CONNECTING FACILITIES/ ACCESS ROOM (DATA
CENTERS)
Manufacturer : LINDNER
Name of product: NORTEC acoustic - pool offices/ executive floor/ connecting facilities like
office, meeting with breakaway & training
Acoustic-effective floor panel with appropriate floor covering and acoustic element
αw = 0.65
Sound absorption class: C
System strengths
Book of standards - 31
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
NORTEC Power
Product features:
Book of standards - 32
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Point load 5 – 8 kN
Reaction to fire performance fully non combustible
Fire resistance performance F30 / REI 30
F60 / REI 60
Electrostatic conductivity ≥ 106 Ω
Weight of system 65 – 81 kg/m²
Floor height 150 mm
Panel thickness 40 – 44.5 mm
Pedestal grid 600 x 600 mm
Sound values
Normalized flanking level
difference D n,f,w,P 49 – 51 dB
62 dB
Sound reduction index Rw,P
Normalized flanking impact sound
pressure level Ln,f,w,P 52 – 70 dB
Reduction of impact sound pressure
Level Δ Lw,P 14 – 28 dB
Book of standards - 33
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Load-bearing capacity 3 kN - 5 kN
Panel thickness 30 mm - 40 mm
Fire protection
Reaction to fire performance of the panel A2, A1 (non-combustible)
Book of standards - 34
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Lindner substructures
Pedestals
- Large adjustable range, Corrosion resistant, High load-bearing capacity&Easy installation
Reinforcement profiles
Reinforcement profiles (pedestals) upgraded load bearing capacity of the flooring system.
C-profiles
System accessories
Book of standards - 35
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Intermediate fl
Book of standards - 36
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Cavity barriers
- Fire protection barriers - made from solid gypsum wall blocks (min. 80 mm)
Floor coverings
wood tile - for Executive floor offices
Book of standards - 37
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 38
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 39
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 40
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 41
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
D. AUDITORIUM
Book of standards - 43
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
E. MAIN CORRIDOR
Manufacturer :FMG FABBRICA MARMI E GRANITI
Name of product: PURE LIGHT IVORY; polished Porcelain tile
Size: ,600 x 600 mm
Color: Light ivory
Book of standards - 44
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 45
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
F. TOILET/ SHOWER
Book of standards - 46
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Wall Tiles
G. TERRACE
Manufacturer :FMG FABBRICA MARMIE GRANITI
Name of product: IMPERIAL WHITE; Granite
Size; 300 x 600 mm
Color: White
Technical Features for IMPERIAL WHITE ; Granite
Book of standards - 47
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 48
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
H. BASEMENT FLOORS
Manufacturer : DRACO ItalianaSpA
Name of product: WEPOX COLOR; pigmented epoxy resin coating
(a two-component, pigmented epoxy resin coating)
Color: Grey (or as per the interior design of basement floors)
Book of standards - 49
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 50
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 51
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 52
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Perforation options
Acoustical information
Book of standards - 53
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Visual selection
Accessories
Book of standards - 54
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 55
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Visual selection
Book of standards - 56
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 57
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 58
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 59
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
B. Lobby (2 & 3 stories high)/ Gallery/ Museum/ Show rooms/ Executive dining/ Restaurants/
Lounge/ Cafe
Manufacturer :Armstrong
Name of product: SOUNDSCAPES Shapes Acoustical Clouds(shape & color shall be decided
by the Architect)
Material
7/8" thick fiberglass with DuraBrite® scrim on face and sides or custom 1-3/4" thick fiberglass
with DuraBrite scrim on all sides (360º finishing).
Surface Finish
DuraBrite (Durable scrim) with factory-applied paint on face and sides. Standard White has
energy-saving, high light-reflective finish (LR 0.90). Back of panel is unfinished with embedded
metal extrusions.
Humidity resistance: 95% RH
Weight Substrate: 4kg/m2 Square panel with hanging frame, 6.5kg
Acoustical performance: 2.48 Sabins per panel (based on Square Panel)
Suspension System: Variety of accessory kits available for individual or group suspension or direct
attachment toplasterboard ceiling.
Fire Performance
SoundScapes Shapes panel material is ASTM E84 Class A: Flame Spread 25 or under and
Smoke Developed 50 or less.
CAN/ULC S102 surface burning characteristics. Flame Spread Rating 25 or less. Smoke
Developed Classification 50 or less.
SoundScapes Shapes, as with other architectural features located in the ceiling plane, may
obstruct or skew the existing or planned fire sprinkler water distribution pattern, or possibly
delay the activation of the fire sprinkler or fire detection system. Consult a fire protection
engineer, NFPA 13, and local codes for guidance on the proper installation techniques where
fire detection or suppression systems are present.
ASTM E1264 Classification
Type XII, Form 2, Pattern E
Acoustical Performance
1.49 Sabins per square foot or 66% more sound absorption than the same square footage of
NRC 0.90 continuous ceilings. Color shapes have slightly reduced acoustical performance.
Color selection - (As per the architects decision and the projects logo)
Book of standards - 60
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Panel selection
Book of standards - 61
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 62
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 63
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 64
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 65
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 66
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Material
Optima is fiberglass with a DuraBrite® acousticallytransparent scrim. Noise is absorbed on both
the front andback of panels (NRC 0.75 - 0.95) and High light reflectance of 0.90 - with a
standard 15/16" Prelude® XL® suspension system.
Surface Finish
Optima White has a DuraBrite finish with factoryappliedlatex paint providing superior light
reflectance.
Anti Mold/Mildew & Bacteria
Optima is inherently resistant to thegrowth of mold, mildew, and bacteria.
Color Selection - white
Cap finish colors Detail
Book of standards - 67
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 68
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 69
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
F. Auditorium/ Multi-Purpose
Manufacturer :Armstrong
Name of product: WoodWorks Access Custom Flat Ceiling Systems- Perforated; size- custom
Material
Fire retardant particle board with face-cut veneers;
Surface finish
Clear or tinted semigloss coating
Fire Performance
ASTM E84 surface burning characteristics, HPVA
Certifiedwith audit program per ASTM E84. Flame
Spread Index 25or less. Smoke Developed Index 50 or
less.CAN/ULC S102 surface burning characteristics.
FlameSpread Rating 25 or less. Smoke Developed
Classification50 or less.
Book of standards - 70
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
G.
H. Childcare
Book of standards - 71
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Manufacturer :Armstrong
Name of product: Cirrus® Themes (Critters, Leaves, stars, Things That Fly)–Tegular
size600 x 600 mm
Material
Wet-formed mineral fiber
surface Finish
Factory-applied latex paint
Fire performance
ASTM E84 and CAN/ULC S102 surface burningcharacteristics. Flame Spread Index 25 or
less.Smoke Developed Index 50 or less.
Anti Mold/Mildew & bacteria
It contains an anti-microbial treatmentand provides guaranteed resistance against growthof
mold/mildew and Gram-positive and Gram-negativeodor/stain-causing bacteria for 30
years.
Color: White
I. Clinic
Book of standards - 72
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Manufacturer :Armstrong
Name of product:Optima® Health Zone Square Tegular size 600 x 600 mm with Prelude
XL 15/16" suspension system
Material
Fiberglass with DuraBriteacoustically transparent membrane; CAC backing.Smooth, clean,
durable finish –Impact, Scratch, and Soil-resistant.Outstanding acoustical performance for
open plan areas, both Articulation Class (190) and NRC (0.95).Long-lasting water-
repellency, Washable and Scrubbable, Safe for use with disinfectants, Energy-saving high
light-reflective finish.
Surface Finish
DuraBrite with factory-applied latex paint
Fire performance
ASTM E84 and CAN/ULC S102 surface burningcharacteristics. Flame Spread Index 25 or
less.Smoke Developed Index 50 or less. (UL labeled)
ASTM E1264 classification
Type XII, Form 2, Pattern E, Fire Class A
Sag resistance
HumiGuard® Plus – superior resistance to saggingin high humidity conditions up to, but not
including,standing water and outdoor applications.
Anti Mold/Mildew & bacteria
Fiberglass substrate is inherently resistantto the growth of mold, mildew, and bacteria.
Details
Book of standards - 73
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Color: White
Book of standards - 74
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.4 SKYLIGHT
Manufacturer :LAMILUX CI SYSTEME
Name of product: LAMILUX CI System glass architecture PR60energysave
Size: Custom as per the design
The profile system
• Extremely stable supporting structure made of rigid aluminum
• Efficient ventilation of glass rebates
• Controlled water and condensate draining by overlapping EPDM secondary draining
• Defined glazing clamping system based on insulating spacer webs
• Elastic bedding of glass panes
Safety on the roof by CE-approved quality in line with EN 13830 (also under 2°
installation pitch)
• Water tightness against driving rain EN12154 / EN12155 /RE 1950
• Airtightness (EN12152 / EN12153 / AE 1950 Pa)
• Resistance towind load (EN13116 / EN12179/2000 Pa permissible load and 3000 Pa
increased load)
Comprehensive soundproofing
• Soundproofing demonstrated in system test in as-installed state as per EN10140-2 up to
46 dB
Energy efficiency:
• Highest passive house efficiency class
– phA advanced component
• Heat transfer coefficient UCWi0.82
W/(m2K)
• No condensate and mould formation
due to stablefRSi value of 0.79
• Low heat loss and high solarheat gain
(ψopak≤ 0.110 W/(mK))
Book of standards - 75
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 76
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.4.1 LIFT
Manufacturer :Schindler
Name of product:Schindler 3300 - Park Avenue type with PORT Technology
Key figures
Capacity 1125 kg - 15 passengers
Travel height Max. 75 m, max. 20 stops
One-sided entrance* 1125 kg
Door width* 1100 mm, type C2
Door height* 2300 mm
Drive system Eco-friendly gearless machine - Machine room less (MRL)
Speed 1.6 m/s
Control Push-button control; stainless steel panel with conventional layout
mechanical push buttons
Interior Style set: Square,
walls: Side wall; Santa Cruz - Laminate Capri Lemon,
Rear wall; Full mirror for core Elevators & full glass for
Panoramic Elevators
Ceiling: Line, Stainless steel Lugano Matt Finish,
Handrail: Straight, Stainless steel Brushed,
Skirting: Aluminum Anodized
Floor: Rubber speckled sand
Car door: Stainless steel Lucerne Brushed
Book of standards - 77
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Performance Security
Group operation up to three elevators Emergency power operation
One-sided entrance * Reservation and restricted access to floors:
Overload detection and visualization in car * via key switch
Two-way communication with assistance center (Telealarm) * via key card
Embedded Tele Monitoring Alarm (ETMA)* via Pin Code (Glass COP 10 key pad)
Automatic return of car to main floor Car call-by-key for parking floors
Automatic evacuation to nearest floor Automatic return to main from parking floors
Car ventilator Penthouse: visitor pick-up control
Floor lighting control Fireman’s control BR1 (EN81-73)
Building management interface Alarm horn in car or in shaft
Design Green
Square interior style sets * Regenerative PF 1 drive
Ceilings with LED lighting * Standby mode
Nameplate for stainless steel COP Automatic car light switch (on/off) *
Glass rear wall: full height Energy saving LED lighting *
Low pit VOC free (Volatile Organic Compound)
Accessibility Lubrication free gearless drive *
Push buttons with conventional keypad layout Halogen-free cabling and wiring
up to 23 floors (– 3 to 20) Shaft ventilation device
Car emergency light * Hybrid Power Manager for PV-panel connection
Book of standards - 78
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Santa Cruz
Colorful and versatile
Book of standards - 79
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 80
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.4.2 ESCALATORS
Manufacturer :Schindler
Name of product:Schindler 9300 Advanced Edition; Type 10 • 35°-K
Detail - Z
Book of standards - 81
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 82
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 83
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.4.3 STAIRCASES
Manufacturer :HDI Railing Systems
Name of product: Kubit ™
Materials
Stainless SteelAISI 304, 316 and 316L grade that is corrosion resistant; standard surface
preparation 240 satin finish for the handrail and post members. A bead blasted finish is
applied tothe post attachments.
Book of standards - 84
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Materials High quality stainless steel, AISI 304, 316 or 316L stainless steel.
Finish Standard surface preparation (240 satin) brushed finish for the handrail.
Infill Panel Tempered glass infill panels 9.5 mm residential or as code requires 12.7
mm commercial or as specified. Custom glass panels available upon
Top Rail request.
Posts 38 mm outside diameter;tube wall 2 mm.
Single flat 51 mm x 13 mm.
Maximum post spacing is 1524 mm for stainless steel handrail between post
Total Height centers.
Panel Link Infill Holder 914 mm handrail, 1067 mm guardrail.
Through bolt connection extended from each post for individual panels
Through Bolt Connection between single posts. Accommodates panel thickness 10 mmto 19 mm.
Through bolt connection mounted directly off of the post with cylindrical
fastening detail to accommodate for single panels between two posts.
Book of standards - 85
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Fastening Types
Core Mount
Maximum post spacing is 1524 mm between post centers for stainless
steel rail.
Concrete: minimum 150 mm thickness, 3000 psi, 76mm edge
distance. An optional cover cap can be specified for the base of the
upright to allow clean concealment of the floor finish interface.
Surface Mount
Surface mount to Concrete, If concrete thickness is more than 133
mm, then quantity (2) 13 mm anchors with 102 mm embedment are
required.3000 psi or greater concrete strength. 76 mm minimum
center line distance from slab edge.Hilti HY 150 MAX-SD chemical
Book of standards - 86
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
anchors recommended.
Surface Mount
Book of standards - 87
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Vanity unit, with space-saving siphon, for washbasin. With floor standing cabinet and soft close
mechanism drawer.
Book of standards - 88
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.5.2 TAP
Public
Description
Soft closing, wall-hung, rimless (optional), Detergent dispensing tank
WC pans include a liquid cleaning tank that dispenses detergent with every flush, cleaning the
pan thoroughly and protecting against bacteria. It also shields the flushing mechanism from the
corrosive effects of cleaning agents placed in the cistern.
Book of standards - 89
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Water saving: special bowl structures and low-flow internal mechanisms, the 2.5/4 L water
conserving WC pans provide efficient flushing with less water, and are certified for the lowest
water consumption by EU standards.
Wall-hung WC pan, 56cm
COLOUR: 003 White
WEIGHT (KG): 25
MATERIAL: Vitreous china
COMPATIBLE WITH:
90-003-009 Toilet seat, soft closing
2.5.4. URINAL
Book of standards - 90
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 91
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 92
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 93
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Paper towel
dispenser for wall
mounting
stainless steel, surface
satin finished,
material thickness 0.8
mm, flat front
cover, cylinder lock
with Franke standard
key, inspection
windows on sides,
loading capacity 500
- 800 paper towels
depending on
convolution, including
stainless steel screws
and dowels.
275 × 355 × 112
mm (W × H × D)
Book of standards - 94
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.5.7. SHOWER
Public
Self-closing (franke)
Book of standards - 95
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Book of standards - 96
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Shower tray
square edge (DuraVit)
Book of standards - 97
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
WC pan
5422S003-5325 Cistern
PRODUCT
2.5.9 GEBERIT
Wallmountedactuator
ConcealedFlushMechanismForBacktoWallWaterCloset
Book of standards - 99
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.6.1 EXTERIOR
Glazed/ metal, partial/flush treated, handle, floor catch Automatic/ manual access/ self-closing,
scratch/wear proof, Sliding/ swing/ Overhead rolling, fire rated, smoke, weather proof, ADA & LEED
compliance
2.6.2 INTERIOR
2.6.2.1 Fire
Fire rating per hour, smoke, metallic/glass, partial/solid, manual access, panic bar handle, floor catch,
swing, ADA & LEED compliance
Operating Stairway
Environment
Factors Standard
Material Steel (treated)
Leaf No Single
Opening configuration Swing
Dimensions
Width x Height 1000x2150
Free Dimension
Width x height 920 x 2110
Fire Class RE 90, REI 60
Air Permeability (Acc. to EN Class 3
1026:2001)
Thermal Resistance (Acc. to EN 2.19 W/m2K
1007-1:2007)
Water Tightness (Acc. to EN Class 3A9B
127:2001)
Resistance to windload (Acc to Class C2
EN 12211:2001)
Cutout window 300x400mm
Surface Finish Select finishing from a wide variety of RAL colours -- NDD – Ninz
Digital Decor, graphic images applied with
special ink jets and protected by a transparent topcoat.
Infinite varieties of customizable decorations in harmony
with specific door settings
Frame “Sendzimir” processed hot-galvanized sheet metal
Grooves for thermo expansive sealing and rebate sealing
Fitting Concrete wall
Accessories (MANDATORY) rubber seal FF/ CR, Nr.2 automatic door sweep
Hinges --Nr. 2 three-wing hinges for each leaf --of which one ball-
bearing hinge with screws for vertical
adjustment of the leaf, marked as per EN 1935, classified
for up to 160 kg load, 200.000 cycles durability,
suitable for fire door use --and one hinge with self-closing spring
Locking mechanism --Reversible locking mechanism with bolt and
central lock -- marked in conformity with EN 12209 standard
Handle --Fire rated handle in black plastic with steel core
Panic Bar
Closing regulator -- Two-leaved doors include an RC/STD closing
regulator to
Book of standards - 104
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.6.2.2 Office
Solid/partial/ full, swing/sliding, handle, floor catch, wooden/glazed, manual access/ self closing,
sound insulation, ADA & LEED compliance
2.6.2.3 Utility
Metallic, fire rating, manual access, partial/full, handle, floor catch, scratch/wear proof, sliding, ADA &
LEED compliance
Operating Environment Kitchen, Kitchenette, Storage, General Store, Archive, MEP Room,
Technical room/ Shaft, Cold Store
Factors Standard
Material Steel
Leaf No 1,2
Opening configuration swing
Dimensions
Thickness Width 1000mm
Width x Height Height 2850 mm
Free Dimension 900mm x 2100mm
Width x height
Sound Insulation (STC) up to 42 dB Rw (= laboratory value)
Valid for flush doors with steel frame and retractable floor
sealing.
Fire Label according to DIN EN 1634:
T30 / EI2 30 C5)
Moisture Resistance (according to RAL-RG o Moisture room (Nr. 08/05-A135-K1)
426) o Wet room (Nr. 08/05-A135-K2)
Strain Class (physical Endurance) Class E (Nr. 03/08-1258)
Cutout none
Edge Finish Lacquered edge in RAL- and NCS-colours
Thickness/ weight ca. 49 mm /ca. 37 kg/m²
Surface Finish Lacquered according to RAL - and NCS – colours
Frame Steel frame (one- and two-piece)
Book of standards - 109
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
Fitting wall
Accessories standard :Lever handles, hinges, locks, door opener
LEED Requirements Recycled Content4.1: Use materials with recycled content
such that the sum of the post-consumer recycled content plus
one-half of the preconsumer
content constitutes at least 10% of the total values of the
material in the project
Recycled Content 4.2:Use materials with recycled content
such that the sum of the post-consumer recycled content plus
one-half of the preconsumer
content constitutes an additional 10% beyond MR Credit
4.1 (total of 20% based on cost) of the total values of
the material in the project
Lebo Luana 1, LA Lock Sided, 1 Big LA,
Moisture resistance, thermal resistance, metallic/ wooden/ treated glazed, flush, sliding, manual access,
handle, ADA & LEED compliance
Operating Environment Changing, Massage, shower Rooms, Steam and Sauna Rooms
Factors Standard
Material Glass
Leaf No single
Opening config. Sliding/ swing
Dimensions Width 1000mmx Height 2850 mm
Free Dimension (WxH) 900mm x 2100mm
Sound Insulation (STC) up to 38 dB Rw (= laboratory value)
Valid for flush doors with steel frame and retractable floor sealing.
Moisture Resistance Moisture room (Nr. 08/05-A135-K1)
(RAL-RG 426) o Wet room (Nr.08/05-A135-K2)
Climate Class Climate class II (Nr. 08/05-A132-Z1)
Strain Class Class S (Nr. 03/08-1257)
Cutout none
Edge Finish Lacquered edge in RAL- and NCS-colours
Thickness/ weight ca. 42 mm / ca. 35 kg/m2
Book of standards - 110
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
2.6.2.5 Sound
Sound insulation, wooden/ glazed, flush/ partial/ treated, handle, automatic/ manual access,
sliding/swing, ADA & LEED compliance
2.6.2.6 Security
Metallic, flush, durability, sound insulation, fire rated, automatic access, ADA & LEED compliance
2.7 INTERIORS
LOBBY AREA
• Structure must support 10 LB/SQFT saturated GSKY versa wall system gravity weight.
• Adequate lighting must be designed and installed min 15 0 foot candles even flood 4.300K
color temp, metal Halide recommended
3.STRUCTURAL
Book of standards - 116
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
3.1General
TheEthioTelecomHeadQuarterBuildingisacomplexbuildingcoveringbuildablearea of
about200,000m2consistsof18blockseachseparatedbymeansofexpansionjointsandgroupedintosevent
ypologicalBlocksasshown inFigure4.1.EachBlockgroupisexplainedbelow:
Block A
Thisblockgroupconsistsoffivesimilar referredtoasBlockA1,A2,A3,A4&A5, on
axesEtoMinthelongitudinaldirectionandaxes2-3-4BlockA1;axes9-10-11Block A2;axes16-17-
18BlockA3;23-24-25BlockA4and30-31-32BlockA5inthetransverse
direction,respectively.These blocksareisolatedfromthe adjoining building
blocksbymeansofexpansionjointssothatnoloadeffectfromtheotherstotherespective
blockcomponentwouldbetransferredoritseffectwillbeaffectinganyotherblockadjacent
toeach.Theblocksassume2B+SB+10 storiesandRCroofslab.
Block B
Theblock groupunderthisconsistsoffourblocksofitsduplicatereferredtoasBlock B1,B2,B3&
B4,onaxesLtoMuptoGroundfloorandL-kabovethegroundinthe longitudinaldirectionandaxes4’-
8’BlockB1;axes11’-15’BlockB2;axes18’-22’
BlockB3and25’-29’BlockB4inthetransversedirection,respectively.Theseblocksare
alsoisolatedfromthe adjoining building
blocksbymeansofexpansionjointsinsimilarmannertotheblock
Agroup.Theblocksassume2B+SB+9storeyandRCroof slab,andareslightlycurvedinplan.
Block C
ThisTheblockgroupunderthisconsistsoffourblocksofitsduplicatereferredtoas BlockC1, C2,
C3&C4,onaxesEtoGuptoGroundfloorandE-Fabovethegroundin
thelongitudinaldirectionandaxes4’-8’Block C1;axes11’-15’Block C2;axes18’-22’
BlockC3and25’-29’BlockC4inthetransversedirection,respectively.Theseblocks
arealsoisolatedfromthe adjoining building
blocksbymeansofexpansionjointsinsimilarmannertotheblockBgroup.Theblocksassume
2B+SB+10 storiesandRCroofslabandareslightlycurvedinplan.
Block D
ThisblockisasinglelongblockreferredtoasBlockD,onaxesAtoD’inthe
longitudinaldirectionandaxes2-11’in the
transversedirection.Thisblockisalsoisolatedfromtheadjoining building
blocksbymeansofexpansionjointsinsimilar
mannertotherestofthebuildingblocks.TheblockassumespartlySB+G+ 2 stories
andRCroofslab.
Block E
Thisblockisasingle,longblockreferredtoasBlockE,onaxesCtoD’inthe
longitudinaldirectionandaxes11-
22’inthetransversedirection.Thisblockisalsoisolatedfromtheadjoiningbuildingblocksbymeansof
expansionjointsinsimilar
mannertotherestofthebuildingblocks.TheblockassumespartlySB+G+2stories andRCroofslab.
Block F
ThisTheblockgroupunderthisconsistsoffourblocksofitsduplicatereferredtoas
BlockF1,F2,F3&F4,onaxesHtoJ’andfallshortofthegroundfloorinthe
Book of standards - 117
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
longitudinaldirectionandaxes4’-8’BlockF1;axes11’-15’BlockF2;axes18’-22’ BlockF3and25’-
29’BlockF4inthetransversedirection,respectively.Theseblocks are alsoisolatedfromthe
adjoining building
blocksbymeansofexpansionjointsinsimilarmannertotheblockBgroup.Theblocksassume2B+SBa
ndRCroofofground slabandareslightlycurvedinplan.
Block G
ThisblockisasinglelongblockreferredtoasBlockG,onaxesCtoD’inthelongitudinaldirectionandax
es22-32inthetransversedirection.Thisblockisalso
isolatedfromtheadjoiningbuildingblocksbymeansofexpansionjointsinsimilar
mannertotherestofthebuildingblocks.TheblockassumespartlySB+G+2stories andRCroofslab.
3.2CodesandStandards
ThedesignCodesusedandtobeusedbythestructuralengineertodetermineloadsonstructureareEuroCode
(EC-2010)andupdated version oftheEthiopianBuildingCodesofStandards(EBCS-
2013,Draft).AstheEuroCodeswillbeimplementedtotheEthiopianpracticewithinthenext couple of
years, the report shall make use of the Euro Codes
wheneverpossible.However,withlimitedguidance on
procedures,alternativecodessuchasACIwillbeusedtofillthegapwithproperexplanationandadjustmentt
o suit tothebasestandards.
Theobjectiveofthispreliminarydesignistoprovidethebasisforthefinalanddetaildesign ofthebuilding
complex.
3.4StructuralSystemRequirements
The structuralarrangement in the finaldesignshallbemade in a mannerthat it can transmit
allloadsconsistingofdead,wind&imposedloadsinadirectmannertothefoundation.
Lateralstabilityinthetwoorthogonaldirectionsshallbeprovidedbyasystemofstrong
pointswithinthestructuresoastoproduceabracednon-
swaystructureinwhich,thestructuralformandframingshallassumethefollowing:
Simplearrangementofslab/beamsandcolumnssothatloadsarecarriedtothe
foundationsbytheshortest andmostdirectroutes,
Thecolumnsarenotsubjectedtosignificantswaymoments,
Strong pointsprovidedbythecorewallsenclosingthestairs,liftsandsurfaceducts,
Additionalstiffnessprovidedbyshearwalls,
Thecoreandshearwallsdistributedthroughoutthestructuralframeworksoarranged
thattheircombinedshearcenterislocatedapproximatelyonthelineoftheresultantinplanoftheapp
liedoverturningforces.Inasituationwheretheabovepointisnotpossible,theresultingtwistingmome
ntsshallbeconsideredwhencalculatingtheload carriedbyeachstrong point.
Strong pointsshallbemadeeffectivethroughoutthefullheightofthebuilding
Where a building structure is divided by expansion joints, each part should be
structurallyindependentanddesignedtobestableandrobustwithoutrelyingonthestabilityofadja
centsections.
3.5Materials
The
structuralmaterialusedismainlyconcreteandreinforcingsteel,specifiedbythecharacteristiccubestrength
at28thdayofageandsteelreferredbyitsyieldstrength.ThedesignequationsneverthelessrefertoConcret
ecylinderstrengthfck,andcharacteristicyieldstrength ofreinforcement,fyk.
Partialfactorsforconcreteare 1.5 forultimatelimit state and
1.0forserviceabilitylimitstates.Thepartialfactorsforreinforcementsteelare1.15for
ultimatelimitstate and1.0forserviceability limit state.
Concrete: Forallmainstructuralframeworkofthebuildingconsistingofslab,stair,
beams&foundationfootings,concretefck=24MPa(cylindercrushingstrengthattheageof
28days,cubeC-30)shallbeused.ForColumnsandshearwalls–Concreteclasscorresponding
tofck= 40 MPa(C-50)or,fck= 32MPa(C-40)shallbeused.
3.6Loading
LoadsandloadcombinationshallbebasedinaccordancetoEthiopianbuildingCodeStandardEBCS
1,2013,Draft(orEuroCodeEC-2010).TheLiveloadingsonfloorsshallbe in accordance with function
oftheparticularfloor.
Forself-weightanddeadloads,weightsfrommaterialpropertiesandweightsoftheitemsinconsideration
shallbeusedfortheactualcalculations.
CategoryD:Shoppingareas
D1:Areasingeneralretailshops
D2:Areasindepartmentstores
Category C
-C1 2.0 to 3.0 3.0 to 4.0
-C2 3.0 to 4.0 2.5 to 7.0(4.0)
-C3 3.0 to 5.0 4.0 to 7.0
-C4 4.5 to 5.0 3.5 to 7.0
-C5 5.0 to 7.5 3.5 to 4.5
Category D
-D1 4.0 to 5.0 3.5 to 7.0(4.0)
-D2 4.0 to 5.0 3.5 to 7.0
Forthepermanentloads,loadingmaybecomputedonthebasisofunitweightandunitvolumeofthematerialu
singthedimensionsspecifiedinthepreliminarydesignandtobe specifiedinthe finaldesign.
3.6.2LateralLoading
Thefirstandmostimportantlateralloadto be
addressedistheearthquakeloadingwhichisdependentthegeographicallocationofProjectsite.Inthisrega
rd,theBuildingsiteisAddisand the coefficient associated with the bed rock acceleration is to be
considered in accordance with the provision andrequirementsofdraftEBCS-8,2013.Suchloading
combined with functionalloadingshallbecheckedforeverymemberoftheframeworkconsisting of
beams,columnsandshearwall.
3.6.3AnyOtherLoading
Otherloadsexhibitedincludelateralloadconsistingoftheearthpressuretotheframedretainingwallcomm
encingfromtheNaturalgroundtothesecondbasementlevel,whichisassumedto be the pressure
ofwhichisdistributedlinearlyassumingpeak at the bottom.The
pressureistobecomputedinaccordancewiththeprovisionofEBCS-7,2013usingeither
RankinsorCoulombsdistributioncoefficient.
Windmay be consideredforthecladdingandforthe glazing supporting frameandanyprojection
butlightstructure with largepanel.
3.7Sub-structure–FoundationTypeandPreliminaryDimensions
Thefoundationinthepreliminarydesignisestablishedusingthehistoryofthebuildingsin the
neighborhoodofthe Tele Building site. Accordingly, the site possess a subsoil of
weatheredrockat a depth not more than 6 m from the naturalgroundlevel,
detailsofwhichtobeconsideredafterthesoilandthegeotechnicalinvestigationistobecarriedout.Asperthei
nvestigationreportandsitefindings,thefinaldesignerisexpectedtoexamintheinformation from the
groundinvestigationanddecideson the type
offoundationtobeusedinthefinaldesign.Inthisregard,thedesignerisexpectedtoconsiderespeciallyanye
xistingoffuturestructureadjacenttotheperimeterofthebuildingstructuresthatmayinfluencenotonlytheloc
ationofthefoundationbutalsoanypossibleeffectonthesuperstructureand adjacent buildings.
Asinthepreliminarydesign,thefollowinghasbeenselected, subject
tomodificationinthefinaldesignafterdetailfindingsofthesuperstructure effect andsubsoilinvestigation.
3.8StructuralAnalysis
Structuralmodelling
Staticactions
Themodelingforstaticactionsshallbebasedonanappropriatechoiceoftheforce- deformation
relationships of the members and their connections and between membersandtheground.
Boundary conditions applied to the model shall represent those intended in the structure.
Effectsofdisplacementsanddeformationsshallbetakenintoaccountinthecontext
ofultimatelimitstateverificationsiftheyresultinasignificantincreaseoftheeffectofactions.
Dynamicactions
4. SANITARY
Book of standards - 124
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
STANDARDSANDCODESOFPRACTICE
Sanitaryandplumbingdesigninvolvesinwatersupplysystem,wastewatercollection,disposalw
ithtreatmentsystem,stormwaterdrainageanddisposalsystemandsubsurfacedrainagecollect
ionsystemfromthebuildingandthecompoundshallcomplywiththerequirementsofpertinentSta
ndardsandCodesofpractice.TheseincludeEBCS1995,BS
5572-1978,BS301-1985&AS3500.2-1990forwastewaterdrainage,BS6700-
1987forwatersupplyandBS6367-1983fordrainageofroofsandpavedareas.
4.1.WATERSUPPLYSYSTEM
DOMESTICWATERSUPPLYSYSTEM
Thedomesticwatersupplytothewholecompoundistobemademainlyfromthemunicipalwatersystemorbor
eholesatthevicinity.Initiallywaterisstoredingroundwaterreservoirandpumpedtoelevated/roof/watert
anksorwheresufficientpressureisattaineddirectsupplyismadefromgroundwaterreservoir.
Alternatelythesupplytoeachfixturecanbedonethroughboasterpumpswithpressurevesselsconnections
Pipesshallbelaidoverrooftops,withinanenclosedarea,orfromwatertanksupporttowersanddropvertica
llydowntodrawoff(outletPoints.)Pipesshallhavetobelaidwithinfloorslabs(inducts),wherefloor-
mountedequipmentistobesupplied.
4.1.1 internal
PIPES,FITTINGS,ACESSORIES
ColdandhotwaterpipesshallbePolypropyleneRandomCo-
polymerresins(PPType3rawmaterial)PPR,PN-
20pipesforcoldandhotwater,andbefixedtoslabs,walls,beamsoretc…withmetalstrapsorsimilarma
terial.
ThepipeshallcomplytoDIN8077,DIN8078,DIN1988,DIN16960,DIN16962etc.Oritsequivalent.
Allfittingsandaccessoriesofwaterpipeinstallationsshallbeofthesamequalityifnothighersideandprov
idedwithmetallicinsertionformetalvalvesandgadgetsinstallations
Theconnecxtioneffectedbythermalfusionusingrecommendedmachines
VALVES,TAPSANDFAUCETS
chromeplatedbrassquarterturnanglevalveswithchromeplatedcopperconnectingpipe,unionnutandc
hromeplatedbrasswallflanges,andaccessoriescompleteinallrespects.TheAnglevalveshouldbecapa
bleresistingofPN-10beforehandwashbasins,waterclosetsandotherfixtures.
bronzeandbrassmadegatevalvescompletewithunions,elasticwaterproofing,handwheelsandallthen
ecessaryaccessoriesorapprovedequalusedwithPN=16AllvalvesshallbecompatibletoPP-Rpipes
Uptoandincluding50mm:Bronzebody,bronzetrim,risingstem,handwheel,insidescrew,singlewedgeor
disc,solderendsasappropriate.flangedends.
DISINFECTION,TESTINGANDCOMMISSIONING
Flushing,disinfectingandtestingandcommissioningofwatersupplysystem.Flushinghastobedonetocleant
hepipelinefromdebrisandsilts.Disinfectinghastobedonewithliquidchlorin8-
10ppm.Allwaterpipesshallbetestedwithpressureof10kg/cm(10bar).asperWHOguidelines
4.1.2 EXTERNAL
PIPES,FITTINGS,ACESSORIES
IfthewatersourceforthesiteistheAAWSSAwatersupplyservicelinetheservicepipefromthetownmainlinebr
anchesbydiameter100mmHDPEtypepipeused,whichdirectlyfillsthewaterreservoirandregulatedbyfloa
tvalveinthereservoirandalsodirectlysuppliesthesystembybypasslinesothesizingwillbedesignedbythisco
nsideration.
externalUVexposedwaterpipesshallbeHighDensityPolyethylene(HDPE),PN-
10pipes,andbelaidonroofandUnitpriceshallincludeallassistancecivilworksandnecessaryfittingssuc
hasT,bendsetc.accordingtowhereshownonthedrawing.Allasperdetails,toISOstandard4427uvresis
tant
ThefittingsandtheaccessoriesfortheHdpepipesshallbeofthesamematerialandtheconnectionshallbe
mechanicalorfusionsystemdependingonthesizesordiameterofthepipeaspertherecommendationsby
themanufacturer
APPURTENANCES
Theexternalwatersupplysystemshallhaveabulkwatermeterforthemunicipalityreadingslocatedaroun
dthefrontageandprotectedandadditionallyalocalizedperblockwatermeterforeachblockisprosedat
eachreservoirinlets
Isolatingbronzevalvesenclosedinavalveboxesmadeofbrickwallandplatecoveredisrequiredwit
hinthecompoundwaterpipelayoutespeciallyforgardeningpurpose.
STORAGESANDPUMPS
Thewaterreservoirisnecessarymainlytomakereadilyavailablefordomesticreserveandthefirefightingi
ncaseoffirebreakandalsotosomeextentforusage.
ForallbuildingsGRPwatertankisselectedbasedonthecurrentengineeringpracticesconsideringfl
exibilityinuse,unitweight,andcost.etc
Thechosenpositionforwaterstationissecondbasementfloorasshownonthedrawing-
thispositionisselectedbecauseof,itsaccessibilityandsecurityreasons,andaboveallspaceavailability.
Foreachblockaseparatereservoirisplacedforflexibilityandmanagementpurposeandfinallyallthetanksw
illbeinterconnectedatlowerlevelandactasaunit.
ThereservoirisselectedtobemadeupofgloballyacceptedGRP(GlassReinforcedPlastic)reservoirswithmu
ltipleof50m3capacityarerecommendeddependingontherequirementattheplanningperiodasshownthe
GRPreservoirsarehygienically,hydraulically,acceptedandeasilycleaned,assembled&dismantled,lightw
eight,longlifematerials.
Theelevatedroofwatertowersarealsoselectedtobethemadeupofmaterialas
ofthereservoirs(GRP)andlocatedoneachblockmosttoprooffortherequiredheight.Seebelow
Thepumpstationislocatedadjacenttothereservoirandalsomadetobeinunderorovergroundforreduction
ofdisturbancesbypumpnoiseandforlessobstruction.
Eachblockwillhaveitsownprimarypumpandforstandbyshareswithothers.Thepumpstationshallhavetwoi
denticalcentrifugalself-
primingelectricanddieseldrivenmotorsforfunctionalandstandbypumpsrespectively.
Thesizingofthepumpsaredeterminedbyusingtheroofwatertankrefillingtimeandfrequencyofstartupan
doffposition
4.2 .WASTEWATERDRAINAGE
4.2.1.INTERNAL
PIPES,FITTINGS,&ACESSORIES
Alldomesticwaste,ventandstormwaterpipelinesshallbecomplytoBS459,BS
4660,BS5481asappropriate,usingdoubleringsealsandgasketscomplyingwithBS2394uPVC,PN-
6pipesandshallbeprovidedwithaminimumslopeasstatedinthedrawing.Pipesandnecessaryfittingssha
llbestandardqualityandbefreefromdamageduringstorage,constructionandetc.Unitpriceshallinclude
allthe
necessaryassistancecivilworks,suchasexcavationcartaway,fixingorhangingtowalls,beamsorslabs.etc.
,necessaryfittingssuchasbends,Y,etc.StormwateruPVC,PN-
6pipesshallresisttheexternaltemperatureandthequalityshallmeetthepurpose.
Basedonthefixturetype,size,flowandtypeofthewastewatergeneratedthefollowingbasicpipesizes
andtrapsareusedforasinglefixture.
Thefixtureunit(FU)ratingisalsodepictedforbranchandhousedrainsandsewersselectedfromEBC
S-9page86…
Todeterminethesizesofbranchesandhousedraintheloadoneachsectionisconsideredintermsoffixtur
eunits.
ThesummationoftheloadintermsoffixtureunitsisusedtoselectthepipesizesfromatableEBCS-9page98-
101withminimumgradeforeachpipesection
Forventilatinginternaldrainageaseparateventingsystemispropsedwhereateachfloorlevelthewastesta
ckisconnectedinsuchawaytobeventedandfinallytheventheadisporturudedtoexternalairabovetheroof
level.
4.2.2.EXTERNAL
ThewastewatergeneratedinallbuildingsisassumedtobecollectedbyusinguPVCwastewaterpipe
andledtothenearbyAAWSSAsewerageline,whichisaroundthebuildingortothecompoundleveltr
eatmentfacility.
AlternativelyifforsomereasonstheconnectiontotheAAWSSAseweragelineisfailedordelayedthewas
tewatercollectedfromthewholebuildingisledtotheseptictankbyupvcpipefortreatment.Afiltermedia,s
oakawaypitfollowstheseptictank,wherebyeffluentisconsideredtobetreatedtosomeextenttobeconne
ctedtothenearbymunicipalwastewaterline.
ForinspectionandAllmanholesalongthesewerlinesshallbeofbrickwallandreinforcedconcretecompletewi
thcast-ironframe,cover,andladderandplacedat
SewerPipediameterchanges
Changesinsewerslope
Junctionswherethereisdirectionofflowchanges
Whereinspectionisneeded
Andatintervalsasshownbelowforinterceptingtheflow
Manholesspacingisbasedonsewersizeandthetypeofareasservedandtheintendeddistancebetwe
enthemanholesisvariable.Typicalcrosssectionanddetailisshown
Therun-
offfromtheroofiscollectedandledtothestormwaterdrainsbyusingupvcdownpipespaintedbyanti-
solarprotectivelayerandsecuredtowalls,slabsbymetalstraps.
Thesizesofthedownpipesareselectedfromachart(area,slope,rainfallintensity&no.&sizeofdrains)bylo
calizingtheroofdrainedareaandconsideringroofarea,roofslopeandtherainfallintensityofImm/hr
Theexternalstormwaterrun-
offthatisthedischargefromtheroofdownpipes,pavements,walkwayandroadsarecollectedbyopena
ndcloseddrains
Thecloseddrainsareinterconnectedbyacircularmanholeslocatedbetweenthedrains
4.4 SUBSURFACEDRAINAGE
Forthebuildingasubsurfacedrainageisprovidedwherebasementisconstructed.Thesubsurfacedrainageis
tointerceptthesubsurfaceflowthatmayaffectthebasementsandsurfaceinfiltrationsbyusingaporousfilter
mediamadeofwashedgravelinawovenpolyethylenesheetgeosyntheticmaterial
Theflowsarecollectedinthemanholesthentosumppitsandfinallydischargedtothenearbystormwaterd
rainagesystembysubmersibleautomaticpumps.
5.FIREFIGHTINGSYSTEM
Book of standards - 131
.
Ethio-Telecom Head Quarter, IT park Addis Ababa
for the building a water-based fire fighting system is designed as per the
requirements set in EBCS-9 and portable multipurpose fire extinguishers placed
adjacent to the FHR
Fire hose reels are used for fire fighting in case of firebreak. For all floors of block
hydrant is designed for the floor the floor area which is less than 800 m2. for area
greater than 800m2 two FHR are used as per the code
Additionally a sprinkler system is used where there is assumed to be public interference
is high and fire expectation is high around public lobby
And also chemical based extinguishers shall be placed at fire vulnerable rooms like
data rooms, kitchen and security
Externally the fire suppression is done by using fire hose reel boxes and portable fire
extinguishers located at four sides of the site and additionally for refilling a fire
brigade track a pillar type fire hydrants are used and located at four corners as
shown.
Sprinkler heads
6. MECHANICAL
Book of standards - 134
.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard
6.1VENTILATIONANDAIRCONDITIONINGSYSTEM
AddisAbabaislocated2400mtabovesealevel,9°21’Nlatitudeand38°45’Elongitude.Max.summert
emperatureis28.5°cDB,19°cWBandmin.wintertemperatureis5°cWB.
Meetingroom,trainingrooms,topmanagerialofficesandboardroomfloorwillbeequippedwithfancoilsc
onnectedtothecoolingsystem.Forallfancoilscondensedwatercollectorpipesshallbelaidandpipesshallb
econnectedtoneareststormwaterdrainageline.
Assemblyhallwillbeequippedwithacoolingchillerandairhandlingunit.(notetobeincluded)Forgym/wor
kout,staffandexecutivedining,stores,technicalroomsandmainkitcheninsemi
basementandgroundfloorwillhavebothsupplyandexhaustairfacilities.(notetobeincluded)
Basementcarparkingwillhavemechanicalsupplyandexhaustairventilation.(notetobeincluded)
Eachblockofficecorridorswillhaveanexhaustairventilation.(noteprincipleofwork)
6.1.1Cooling
Thecoolingforthecoolingandairconditioningofoccupanciesintheofficebuildingblocksaswellasthecoo
lingofassemblyhallinstallationistobecarriedoutbyacoolingwithanaircooledchiller,moreeconomical
alternativesarepossible.Integratedhydronicmoduleaircooledchillersarepreferred.
Thenecessarycoolingcapacityistobecalculatedandaneconomicalcoolingsystemistobeconstructed.The
pumpsofthechilleraretobecarriedoutasdoublepumpsandattentionistobepaidtothefrostresistanceofth
efacilities.
- Coolingmachinery aircooled
- Typeofdrive electric
- Coolingagents R410A
- Refrigerationcapacity Accordingtocoolingloadcalculation
- Systemtemperature 6°/12°C
- Dimensioningfortemperatureupto40°C
Figure:chillerwithintegratedhydraulicmodule
Preferredmake:manufacturer:YorkorCarrier
6.1.2Pipematerials,insulation:
AllthepipelinenetworksandfittingsareusuallytobedesignedandverifiedatratedpressureofPN10b
ar.Theappropriateacceptancerecordsincludingproofofflushingshouldbepresented.
Colddistribution/chillingpipeworkDuracoolpre-insulatedABSpipes.
Insulationwithdiffusionproofrubberinsulation,basedonthequalitystandardofthecompany,Armstrongpr
oductArmaflex19mminsulationthickness,gluedontheentiresurfaceofthe
pipewalls.Outsidechillingpipeworkshallbewithprotectivejacketmadeofmetal.
AllpipelinenetworkshaveacoatofpaintorinsulationandaretobemarkedinEnglishwithpermanentla
bels.
6.1.3 TableshowingVentilationandAirconditioningsystemforoccupancies
HumidityDescription
Ambientdesignhumidityshallbe90(winter)/40(summer)
Aspecifichumidificationanddehumidificationoftheairisnotplanned.Recom
mendedminimumfreshairsupplyratesforroomis10liter/sec.
Roomnoiselevel
6.1.4 Theroomnoiselevelshouldbeagreedwiththeclient
Occupancy NoiseLeveldb(A)
Offices 30
ManagerialofficesandBoardroom 30
Meetingrooms/Auditorium 30
Gymnasium 60
Kitchen 40
6.3GeneralRequirementsofVentilationandAir-
ConditioningUnitsandOtherEquipments.
Controlsystemofventilationandcoolingshallrenderthefollowingfeatures.
-Temperaturecontrol
-Airmixingcontrol
-Supervisionoverfreezing
-Dailyandweeklyprogram
• Maximumpressuredropheating-andcoolingcoilsshallbe30kPaonwaterside.
• Maximumairvelocityforcoolingcoilsinshallbe2.0m/s.
6.3.2Airfilter
Airfilters,factorymade,designedasfollowsandaccordingtoEthiopiannormsAHU´sshallbeprovidedwit
hcleanablefiltersequippedwithpressuredifferencedetector.
AHU’sshallbeprovidedoneextrasetoffilter.Ifpossiblesparefiltershallbepossibletobuylocally.
6.3.3Dampers
Adjustment dampers in duct-work shall be type iris damper, to be designed for cleaning inside
ducts by opening the damper.
Requested Fire dampers shall be provided according to Ethiopian standard EBCS-11 and also
fulfill the following.
The fire dampers shall be connected to a supervision and control system connected to the Fire
Alarm center.
If any of the dampers are not functional as planned, the malfunction shall be indicated.
In case of power brake and in case of stopped fans, dampers for smoke and dampers for both
smoke and fire shall close.
6.3.4Fans
Thefansshallbecompletelyequippedtoachieveintendedfunctions.
Theexhaustfanforthekitchenexhaustshallbebeltdrivencentrifugalfanswithbackwardstraightimpellers
,inspectioncoveronthecasingandadrainbossinthebottomofthecasing.
Thecapacityofthefansandmotorsshallinclude15%asareserve.Rooflocat
edfansshallbeassembledonfactorymaderoofcurbs.
TheoutdoorfansshallbecoatedtobeprotectedfortheclimateofAddisAbaba.
6.3.5Silencer
Providefactorymadesilencerswhichshallfacilitateeasyinsidecleaning.Silencersshallbeinstalledt
ofulfillthenoiselevelrequirement.
6.3.6Ducts
Ventilationchannelsaswellasrequiredpipefittingsandroundpipeswithrelevantpipefittingsshouldbem
adeofgalvanizedsteeltinwithproperhangingsandstiffening.Inventilationchannels/pipessuitableinspe
ctionopeningsprovidedforchannelcleaningworksshouldbeinstalled.
Ductsandductworkelementsshallbegalvanized,factorymade,designedasfollowsandaccording
toEthiopianstandards.
Kitchenandsmokeexhaustductsshallbemadebyweldedblacksteelsheetof1.5mmthicknessinordertobeli
quidproof.
Provideaccessdoorsforcleaningeverypartofthesystem.Horizontalductsshallbeexecutedwithslopetof
acilitatedischargeofcleaningliquid.Lowestedgeprovidedwithdischargevalve.
Exhaustductsfromdishwashingmachinesbycircularwoundfactorymadealuminum.
• Maximumpressuredropshallbe0,8Pa/m
• Minimumdiametershallbe130mm.
• Ductsshallbeprovidedwithinspectionpanels(hatches)facilitateinsidecleaningandinspect
ion.
• Openductendsshallbeprotectedfromdirtwithprovisionalarrangements.
• Beforethe“TestsonCompletion”allductsshallbecleanedinsideandoutside.
Supplyandexhaustairdevicesmaybeconnectedtotheductswithamaximumof1mlongflexiblemetal
tubeiftheconnectionpointislocatedaboveaclosedsuspendedceiling.
6.3.7Accessdoors
Tofacilitateforinspection,cleaningandmaintenanceaccessdoorsshallbeerectedinspecialsectionsahe
adofallcoolingandheatingcoils(bothsides)etc.
6.3.8Ductworkinstallation
Coolairductsshallbeinsulatedwithmineralwool,byblanketminimumthickness25mmandcoveredwithA
luminumfoilinclosedsuspendedceilings.Visiblecoolairductsshallnotbeinsulated.
Acousticinsulationshallbemadeinternallybymineralwoolandcoveredwithperforatedgalvanized
sheetmetal.
Fireinsulationshallbemadebymineralwool.Visibleinsulationshallbecoveredwithmetalfolioandwire
mesh.Elsewherewiremesh.
6.3.9Supplyandexhaustairdevices
Alldevicesshallbefactorymadeofstandardtypemodelswithadjustableairflowratesanddirections;It
shallbepossibletomeasuretheairflowfromalldevices.Airflowsfromsupplyandexhaustdevicesshallb
eshownonthedrawingsforeachoccupancy.
Devicesshallbeeasytocleanandmadebyfactorypaintedsteelsheet,oranodizedaluminum.
6.3.10Cowlsonrooflocated
Cowlsshallbefactorymadebygalvanizedsteelsheetassembledonfactorymaderoofcurb.
6.3.11Out-doorairintakegrilles
Grillesshallbefactorymadebygalvanizedsteelsheet.
6.3.12Analogousthermometers
Provideanalogousthermometersinallventilationandairconditioningsystemstoseetheirtemperature
schange.
6.5CoolingSystem
6.5.1Functionoverview
ThecoolingofchilledwatersupplyingbuildingpremisesandFan-
coilunitsshallbeaccomplishedbymeansofnecessarynumbersfactoryassembledandfactoryfullloadr
untested“Microprocessorcontrolled,air-
cooledliquidchillersutilizingscrollcompressorsandhydraulicpumpsystems’’.
CoolingwatersystemsshallbeconnectedtoallfancoilunitsandtoallAirHandlingUnits.Thecoolingsystems
shallbeconnectedandmonitoredbytheBMS.
Thecoolingplantshallbeinstalledaccordingtowhereshowninthedrawingandbeofhydraulicmo
dulewithdualpump.
Unitshallalsobeprovidedwith:
Factoryinstalledmicroprocessor-controlled,minimum-
loadcontrolthatshallpermitunitoperationdowntoaminimumof15%capacity.
• Coolerheatersprovideprotectionfromcoolerfreeze.
• Safetyarrangements,mudstrainersandautomaticallyoperatingairmicrobubblesep
arators.
• Buffertanks
• Hydronicmodulechilledwaterpumpswithstand-bypumpsandwithauto-changeover.
• Factorymadeelectricswitch-boardsandcontrolboards
Thecoolingofairconditioningshallbeaccomplishedbymeansofonefactorymadewaterchilledunitus
ingenvironmentallyapprovedcoolingagent,FreonR410Aorequal.
Theair-
coolingcondensersshallbedimensionedformaximumoutdoortemperaturesof+40°C.Theevaporatorssh
allbedimensionedforcoolingwatertemperatures6/12°C
6.5.3CoolingWaterDistributionNetwork
ThechilledwatersystemsshallbedesignedastwopipesystemssuppliesAirHandlingUnitsandfancoils.Thes
ystemshallbedesignedandconstructedforthecalculatedcapacitiesofthebuilding.
Pipenetworkshallbedesignedmaximumpressuredrop,100Pa/m.
Material:ABS-Duracool
Thecoolingdistributionnetworkshallbeequippedwithsufficientnumberofclosingandadjustingval
vesinordertoadjustittocorrectwaterflows.
AHU’sandallfancoilsshallbeequippedwithclosingvalves.
Coldwaterpipesinsulationshouldbeapprovedqualityofrubberinsulationmaterial(Armaflexorsim
ilar).Jointsoftheinsulationshallbegluedandtight.Thefancoilsshallbedesignedforlowtemperaturei
ncludingheater.
6.5.4Consumables&SpareParts
Thefollowingminimumsparepartswillbeprovided;
PriortohandingoverthenContractorshallprovideconsumablesasfollow:
1.VentilationsystemfiltersminimumoneseteachAHU.
2.Fanbelts2pcseachfan.
6.5.5MarkingandLabeling
Pipesandductsplastictape360ºvisibilitiesshowingthemediainplaintextaswelldifferentcolourandfl
owdirection.Distanceshallbefrequent.
Allpartslikepumps;AHU,valves,controllersetc.shallbelabeledwithindividualidentificationno.engrave
donwhiteplasticsheets.
6.5.6ContractorsTestingandAdjustmentsbeforeCompletion
TheContractorshallsubmitadetailedtestprogrammefortheEmployersapprovalbeforestartingthe
tests.
Thefollowinggeneraltestsshallbeprovided,
• Performancetests(totalcapacityetc.)ofeachsystem
• Adjustmentsofallflowratesinliquidandairsystems
• Soundleveltestsinoccupiedzones
• Water,coolingsystem,
• Tightness(pressure)testsofallpipes
• Performancetestsofcoolingplants(systems).
TheContractorshallpromptlyforwardtotheEmployerdulycertifiedreportofthetests.
Ventilationandairconditioningsystems,
1.Performancetestsofmaximumtransmittedheatingandcoolingpowerforeachheatingandcoolingc
oils.
2.Performancetestsofairflowratesineachsystem
TheBMS-system
1.Allsystemsandfunctionsshallbetestedfromthecomputer.
2.Oneweekfaultfreecompletelogallsystemswillbeprovide
7.ELECTRICAL
Ceiling type Exposed- and Options Emergency lighting Concealed ceilings: bracket
symmetrical concealed (integrated): 3hours (EL3)* ZBS460SMB (1 set = 4 pcs)
T-bar ceiling and plaster Lighting controls: reach is 25 - 65mmConcealed
(board) ceiling Actilumemulticontroller(ACL)* ceiling with T-bar 38 mm:
Ceiling grid Module size in Compatible with DALI (only bracket ZBS460 SMB-TPM (1
length: 600 x 600 mm, relatingto dimmable driver set = 4pcs)
Module size in length: 625 x PSD)Euro fuse (FU) included Brackets for plaster ceilings
625 *not for BBS561 ZBS460
Module length: 675 x 675 mm Materials Housing: zinc- SMB-PLC (1 set = 12/24
Light source Philips DayZone coated steel pcs)*Through-wiring possible
LED module Rim: post lacquered *Suspension brackets are
4000 K: 51 W (LED35S) Optical cover: acrylic (AC- included for
3000 K: 55 W (LED35S) MLO),polycarbonate (PC- BBS561
Beam angle 90º MLO) Connection Push-in connector
Lum.flux 3500 lm Color White (WH), silver grey (PI) or with pull
(independent of CCT) Exposed ceilings: in lay, no relief (PIP)
Driver Built-in bracketsneeded Wieland connector GST 18, 3
or 4poles (W, W4)
Manufacturer Formagenda
Name of Product: Tape
TAPE is a lighting-range that uses the latest high end LED-technology. The
innovative setup allows a very thin design. The LED is providing a warm
comfortable atmosphere. Like a slip of paper TAPE seems to float in front of
the wall or above the table. With its minimal and light but still powerful
design TAPE is a highlight in every room.
Material: aluminiumanodized
Colours: black, white, silver, champagne, aluminum polished
Designer Hans Buschfeld developed the low-voltage system LightLight® system, OLEDs are suspended in the
space on fine wires of differing lengths.
Using LightLight® modular components, the track can be combined to meet project-specific requirements.
Hundreds of BLACKBODY OLED elements (1.6W / OLED) vary in colour temperature between 2700 K and
3000 K.I.Rain is a customized luminous object. Sending inquiries with square measurements and design to
designers is possible.
GALLERY LIGHTS
Manufacturer Ingo Maurer
GALLERY LIGHTS
Manufacturer: Barrisol
Name of product:
Contemporary Light Column
Barrisol Lumière Color stretch
ceiling allows a multitude of
moods and ambiences to be
created thanks to the light
variation and color changes. The
rhythm, animations, and emphasis
of the space is dependent on
which specific lighting system is
installed above the Barrisol
translucent stretch ceiling.
Barrisol Lumière Color uses a Barrisol translucent sheet enlightened by a higher source of light. It then
becomes possible to play with the light intensity and different colors thanks to a system of light variation
(LED lighting).
XP2040-60
59cm x 70cm, h 9,4cm
24W/830 HO24SLS G5
XP2040-90
89cm x 70cm, h 9,4cm
39W/830 HO39SLS G5
XP2040-120
119cm x 70cm, h 9,4cm
54W/830 HO54SLS G5
Manufacturer:KOBE
Name of Product: KAGAWA Line
Description: Decorative pendant light luminare
for LED with its own reflector.
Technical Details: luminare made out of top
quality aluminum material, painted ecru and
black electronic or HF ballast, luminare
featuring wire suspension and transparent
supply wire.
Application: conference halls , galleries, offices
Accessory
• IP68 connector (Cod. CS093002)
OUTDOOR LIGHT FITTING( Bollard Type)
Decorative “total light” fitting with recessed body in 2 heights: 98mm and 501mm
Requiring recessed box
Color
White translucent
Suitable forPedestrian areas, paths, private gardens
Special features
Total lighting optics
Maximum safety through separation of wiring and optics
Technical details-fitting
• Anodized die-cast aluminium body
• Flat trasparent tempered glass diffuser 12mm thickness
• Cylindrical optics in white translucent polycarbonate
• Closing cap in reinforced thermoplastic
• Thermoplastic conical reflector
• Stainless steel screws
Technical details RGB
• Led RGB full color 3x3 EDISON supplied in 12V PWM
• Cable 4x0,5mmq H05RN-F (1mt)
Compulsory accessories
• Recessed box Ø190x270mm (Cod. 7000.0002)
Compulsory accessories RGB
• DMX generator (Cod. CS180011)
• DMX controller with driver (Cod. CS180008)
• RGB connection kit 4 pole (Cod. CS180018)
Accessory
• IP68 connector (Cod. CS093002)
FACADE FLOODLIGHT
Manufacturer: Toshiba
Product name :outdoor projector / ip65 / led floodlight 5500
FEATURES
Dimmable: No
Electrical class: II
Protection rating: IP65
Power factor: 0.9
Temperature range: -20 °C - +35 °C
Constant lumen output
ENEC
Suitable for
Main and secondary roads, cycle paths, pedestrian areas, parking areas, public and private gardens,
squares
Accessories/Compositions
Stud System
Special features
Pull-out wiring compartment closing door for easy maintenance
Conforms to local and international dark sky laws
Possibility of direct current supply in 12V to integrate the photovoltaic installation
High lighting efficiency
Energy saving
Sensor LED Detection Indicator :Shows when sensor is detecting in daytime and glows red at night for
"on-guard" deterrence.
Sensor Advanced Detection Logic :Minimizes false triggers.
Description:
Small recessed unit comprising a square Zamak
embellisher and a square/round diffuser of
tempered glass. Mains voltage power supply 230V
AC or 24V AC/DC.Lights up by LEDs. Has
accessories to also operate when mains power is
off (PBL units) or with a low safety voltage (TL
transformer).
Characteristics
Format: Lecu round or square
Operation: Luminaire, Self-contained
Voltage: 230 V 50Hz / 24V AC/DC
Autonomy (h): It depends on the PBL power suppy
unit PBL*. 1h Self-contained
Emergency lamp: White Led for Self-contained
Mains lamp: White Led
Degree of protection: IP 65 IK06, IP 66 IK06 (Inside
recessing box, adequate for outdoor)
Electrical insulation: Type II and Type III
Colours: cool white, Warm white, Blue
BATHROOM LIGHTS
Manufacturer: Pujolilluminacion
Family: ARCOS
Application: Bathroom Lights
Description: Wall lamp with LED strip
Versions: USA UK J
Diffuser: Polycarbonate
Frame: Aluminium
Finishes: Chrome - Matt nickel - White - Antracita Mate
Bulb:
LED 40W 3300lm 3000K (4000K optional)
GALLERY LIGHTS
Manufacturer Sattler
Name of Product: CircoloTris
Contemporarily interpreted
chandelier UNIONE, consisting
out of 6 illuminated rings out of
aluminum, light output outwards,
with applied acrylic diffuser,
ceiling canopy for fixation and
steel cable suspension; 24V LED
technology; colour temperature
3000K, optionally 4000K and
dimming (1-10V or Dali). Frame
color white, polished aluminum.