You are on page 1of 161

Ethio-Telecom Head Quarter, IT park Addis Ababa

Contents
2.ARCHITECTURE ........................................................................................................................................... 4
2.1Facade System..................................................................................................................................... 5
2.1.1. Curtain wall façade, façade system and glazing............................................................... 5
2.1.2. Prefab colored concrete .......................................................................................................... 8
2.2 Internal wall ......................................................................................................................................11
2.3 SURFACE FINISH...............................................................................................................................31
2.3.1FLOOR FINISH ............................................................................................................................31
2.3.2 WALL FINISH .............................................................................................................................51
2.3 CEILING FINISH ...............................................................................................................................53
2.4 SKYLIGHT ..........................................................................................................................................75
2.4 TRANSPORT SYSTEM.......................................................................................................................77
2.4.1 LIFT ..............................................................................................................................................77
2.4.2 ESCALATORS .............................................................................................................................81
2.4.3 STAIRCASES ...............................................................................................................................84
2.5 SANITARY FIXTURES ........................................................................................................................88
2.5.1 WASHING BASIN .....................................................................................................................88
2.5.2 TAP ..............................................................................................................................................89
2.5.3 TOILET PANS (VitrA Fresh M line)..........................................................................................89
2.5.4. URINAL.......................................................................................................................................90
2.5.5. SEPARATORS ceramic(Laufen)Rion, urinal division ............................................................91
2.5.6 ACCESSORIES (stainless steel) (Franke) ...............................................................................91
2.5.7. SHOWER ...................................................................................................................................95
2.5.8.ACCESSIBLE SANITARY FIXTURES (VitraDOC-M PACK) ...................................................98
2.5.9 GEBERIT ......................................................................................................................................99
2.6.1 EXTERIOR................................................................................................................................. 100
2.6.2 INTERIOR ................................................................................................................................. 104
2.6.2.3 Utility ........................................................................................................................................ 109
2.6.2.4 Wet Area ................................................................................................................................ 110
2.6.2.5 Sound........................................................................................................................................ 111
2.7 INTERIORS ...................................................................................................................................... 114
Book of standards - 1
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.7.1 INTERIOR SEATING CUM GREENERY ................................................................................ 114


2.7.2 INTERIOR VEGETATION ...................................................................................................... 115
3.STRUCTURAL .......................................................................................................................................... 116
3.1General ............................................................................................................................................ 117
3.2CodesandStandards ...................................................................................................................... 119
3.3 Depth and Extent of Preliminary Design................................................................................... 119
3.4StructuralSystemRequirements ...................................................................................................... 119
3.5Materials .......................................................................................................................................... 120
3.6Loading ............................................................................................................................................ 120
3.6.1 Gravity Loading .................................................................................................................... 120
3.6.2LateralLoading ........................................................................................................................ 121
3.6.3AnyOtherLoading ................................................................................................................... 121
3.7Sub-structure–FoundationTypeandPreliminaryDimensions ...................................................... 121
3.8StructuralAnalysis ............................................................................................................................ 122
4. SANITARY .............................................................................................................................................. 124
4.1.WATERSUPPLYSYSTEM ................................................................................................................ 125
DOMESTICWATERSUPPLYSYSTEM ........................................................................................................ 125
4.1.1 internal..................................................................................................................................... 125
4.1.2 EXTERNAL................................................................................................................................ 126
4.2 .WASTEWATERDRAINAGE .......................................................................................................... 129
4.2.1.INTERNAL ................................................................................................................................ 129
4.2.2.EXTERNAL ................................................................................................................................ 129
4.3 STORM WATER DRAINAGE ........................................................................................................ 130
4.4 SUBSURFACEDRAINAGE ............................................................................................................. 130
5.FIREFIGHTINGSYSTEM ........................................................................................................................ 131
5.0 FIRE FIGHTING SYSTEM............................................................................................................... 132
6. MECHANICAL ....................................................................................................................................... 134
6.1VENTILATIONANDAIRCONDITIONINGSYSTEM....................................................................... 135
6.1.1Cooling ..................................................................................................................................... 135
6.1.2Pipematerials,insulation: ....................................................................................................... 136
6.1.3 TableshowingVentilationandAirconditioningsystemforoccupancies.............................. 136
6.1.4 Theroomnoiselevelshouldbeagreedwiththeclient ............................................................. 137

Book of standards - 2
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

6.3GeneralRequirementsofVentilationandAir-ConditioningUnitsandOtherEquipments. .......... 137


6.3.1 Cooling coils............................................................................................................................ 137
6.3.2Airfilter .................................................................................................................................... 138
6.3.3Dampers .................................................................................................................................. 138
6.3.4Fans ........................................................................................................................................... 138
6.3.5Silencer ..................................................................................................................................... 138
6.3.6Ducts .......................................................................................................................................... 139
6.3.7Accessdoors.............................................................................................................................. 139
6.3.8Ductworkinstallation ............................................................................................................... 139
6.3.9Supplyandexhaustairdevices ............................................................................................... 139
6.3.10Cowlsonrooflocated ........................................................................................................... 140
6.3.11Out-doorairintakegrilles .................................................................................................. 140
6.3.12Analogousthermometers .................................................................................................. 140
6.5CoolingSystem ................................................................................................................................ 140
6.5.1Functionoverview .................................................................................................................... 140
6.5.3CoolingWaterDistributionNetwork ..................................................................................... 141
6.5.4Consumables&SpareParts .................................................................................................... 141
6.5.5MarkingandLabeling ............................................................................................................ 141
6.5.6ContractorsTestingandAdjustmentsbeforeCompletion ................................................ 141
7.ELECTRICAL ............................................................................................................................................. 143
7.2.1 OFFICE BLOCK LIGHT........................................................................................................... 144
7.2.2 LOBBY AND GALLERY LIGHTS ............................................................................................ 146
Manufacturer: Barrisol ......................................................................................................................... 148
7.2.3 CONFERENCE AND MEETING ROOM LIGHTS ................................................................ 149
7.2.4 AUDITORIUM LIGHTS ........................................................................................................... 150
7.2.5 BASEMENT LIGHTS ................................................................................................................ 152
7.2.5 OUTDOOR LIGHTS ............................................................................................................... 152
7.2.7 MISCELLANEOUS LIGHTS .................................................................................................... 156

Book of standards - 3
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.ARCHITECTURE
Book of standards - 4
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.1Facade System

2.1.1. Curtain wall façade, façade system and glazing


FAÇADE SYSTEM
Manufacturer - Pilkington
Product name-Pilkington Planar façade
Description
- A structural glazing system that provides a flush glass
surface, by utilizing stainless steel fittings housed in
countersunk holes to fix the glass façade back to the
structure, instead of using the more conventional framed
systems.
- The exterior glass used in all Pilkington Planar™
systems is normally 10, 12, 15 or 19 mm thick Pilkington
optifloat™ heat soaked toughened glass.
- Pilkington Planar™ can incorporate most Pilkington
glass types, including our the range of solar control,
low-emissivity, screen printed glass as well as our
Pilkington Activ™ self-cleaning glass.

Applications
- Total building cladding.
- curtain walls,
- complex three dimensional façades and
roofs,
- opening lights and
- Curved glasses.
Features
- Flush external surface.
- Engineered to permit glazing in any plane:
vertical, horizontal or sloping.
- High quality and appearance of materials.
- Most widely tested structural glazing system.
- Can incorporate most Pilkington glass types

Book of standards - 5
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

GLAZING
Manufacturer - Pilkington
Product name- Pilkington ActivSuncool(Self-cleaning high performance solar control and
low-emissivity glass)
Description
- self-cleaning
- solar control
- dual coated glass(thermal insulation)
o surface #1 self-cleaning on-line coating with photo-
catalytic and hydrophilic properties
o surface #2 superior off-line solar control and low-
emissivity coating, with high light transmittance, high
light reflectance
- Available in clear or neutral appearances and in two
distinctive colors: blue and silver.
Applications
- As insulating glass units
- for large glazed areas
- for commercial and residential applications
- As toughened or laminated glass.
Features
- Self-cleaning
- superior solar control
- high light transmission and reflection
- Superior low-emissivity, with U-values down to 1. 0 W/m2K in 6-16-4 standard
constructions with argon (90%),
- available in 6 and 8 mm; 4 mm thickness, 10 mm is available on special request
- Maximum size of primary monolithic product is 2500 mm x 4500 mm
- harmonizing spandrel panels (if needed)
o Pilkington Spandrel Glass Coated A140
 Appearance in reflection- Neutral/blue
 Level of reflection – High(29%)
Product name- Pilkington ActivSuncool 40/22(Pilkington Spandrel Glass Coated A140)
Note
- Maximum size of primary monolithic
product is 6000 mm x 3210 mm.
- The primary product shall only be used
in insulating glass units.
- 16 mm (double glazed units)
Glass configuration
- triple insulating glass unit, Pilkington
Optitherm™ S3 #5
- insulating glass unit,
Pilkington Optitherm™ S3 #3
Pilkington K Glass™ #3
Primary product outside #1+2
Performance code:
Book of standards - 6
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

U value 1.1 W/m2K


Light 37
Energy 21
Light:
Transmittance 37
Reflectance outside 25
Reflectance inside 23
Color rendering index 91
Energy:
Direct transmittance 18
Reflectance 40
Absorptance 42
Total transmittance 21
Shortwave shading coefficient 0.21
Long wave shading coefficient 0.03
Total shading coefficient 0.24
S, UV
Selectivity index 1.76
UV transmittance 5
Manufacturer - Pilkington
Product name- Pilkington Optifloat™ Green, insulating glass unit, Pilkington Optitherm™
S1 #3
Description
- Uncoated body-tintedglass, with low light
reflection and high energy absorption.

Applications
- used wherevera colored glass without surface
coating is required
- Wherea safety glass is required, they can be
specified as toughened orlaminated glass.
Features
- Reducing the need for air-conditioning.
- Solar control performance and color density vary
with thethickness.
- Available in Green, Blue-Green, Bronze andGrey colors
- Low internal and external reflection,
- Reduce uncomfortable glarefrom the sun, and offering improved privacy compared to
clearglass.
- Reduce UV radiation.
- Can be laminated, toughened, bent and enameled using standardtechniques.
- Available from 3 mm to 10 mm thicknessdepending on the color.
- Satisfies the requirements for harmonized European Norm EN 572.

Performance code:
U value 1.0 W/m2K
Light 58
Energy 34
Light:

Book of standards - 7
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Transmittance 58
Reflectance outside 16
Reflectance inside 22
Color rendering index 88
Energy:
Direct transmittance 28
Reflectance 13
Absorptance 59
Total transmittance 34
Shortwave shading coefficient .32
Long wave shading coefficient .07
Total shading coefficient .39
S, UV
Selectivity index 1.71
UV transmittance 11

2.1.2. Prefab colored concrete

PCI Architectural Precast Concrete Color and


Texture Selection Guide
Manufacturer - RIEDER
Product name-Fiber-c concrete (concrete skin)

- solid, moldable and durable


- also thin-walled, fireproof and light-weight
- endures maximum load capacity at minimal thickness
and enormous slab size
- used for buildings with a height of up to 300 m
- can be completely recycled
- allows cost-saving constructions of high quality, cutting-
edge aesthetics and long-term durability
Technical Data
·
- good thermic values and fire resistance class A1
according to DIN standard,
- highest fire resistance and thermal stability up to 350°
Celsius·
- Performance:Highest loading capacity at minimum cross
sections and Enormous panel sizes set new standards in
facade engineering for interior and exterior applications.
- Durability: Long-term,over 50 years.
- Authenticity: The use of purely mineral raw materials, top
quality
- Formability: bending, forming and chamfering of
elements in one piece at constant solidity and without
adhesive
- Individuality: Each element is unique in size, colour and
surface.
Specification
Book of standards - 8
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Sizes: 1,2 x 2,5 m and 1,2 x 3,6 m (purpose-designed sizes on request)


Thickness: 8, 10 and 13 mm
Thickness tolerance max: ± 1mm
Bending tensile strength min: 18 Mpa according to EN 12467
Elasticity Module: 20.000 N/mm²
Dead Load: 26 - 32 kg/m2 (13 mm)
Thermal expansion coefficient: 10 x 10-6K-1
Building material class A1 (according to DIN 4102): incombustible
Thermal Stability depending on slab humidity: up to 350° Celsius
Waterproofness, Thermal and Rain testing and frost Resistance Waterproofness
according
Fixing depending on geometry and
Fastening visible application
Fastening invisible screws
Substructure casted anchor system
Joint width aluminum, steel, stainless steel
Casted anchors min. 8 mm
± 5.0 mm
to
EN 12467

Colors & Textures


Color and texture can be specified by the architect.
Manufacturer - RIEDER
Product name- 3 Dimensional Fiber-c concrete facades (“Monolithic Cast “)

- Each element consists of a uniform and non-separable unit for a monolithic appearance.
- Individual | the modular formwork construction is done based on the Architects’
individual design.
- The color of the concrete matrix is variable.
- The characteristic appearance of concrete creates a vivid and authentic surface on the
facade.
- Intelligent assembly | Fixing anchors can be integrated during the production process
(concealed) or added with screws later on.
Technical data
Color: variable, color specification and tolerances to be defined by mock-up
Surface:visible side on one or both panel sides, other surfaces textures on requestdepending on
statics alkali-resistant
Reinforcement:grassfires and steel or stainless steel client specific defined by mock-up,
Edge formation:each fiber C 3D panel is regarded as a single piece.

Book of standards - 9
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Visual characteristics: Differences in color, structure and texture are characteristic.


Efflorescence’s or small, visible pores are not defects. The light resistance varies depending on
the color Differences in the surface appearance; do not affect the technical characteristics of
the panels

Technical Specification fiber 3D Norm


Size 1500 x 3600 mm
Special sizes/geometric on request
shapes/surface structures ± 3 mm
Dimensional variation l < 1 m ± 0.2 % * l; max = 5 mm
Dimensional variation l > 1 m ± 3.5 mm | ± 4 mm
Diagonal difference up to | above 1.5 ± 5 mm | ± 6 mm
m
Diagonal difference above 2.5 m | 3.6
m
Thickness 25 mm - 100 mm
Tolerance thickness ± 2 mm
Physical Characteristics
Tolerances facing up to 600 mm | ± 2 mm | ± 4 mm for flat panels DIN 18202
1200 mm ± 8 mm for flat panels
Tolerances facing up to 3600 mm 0.384 mm/m0.737 mm/m DIN 18202
Swelling 0.34 %
Shrinkage ca. 2.4 kg/dm³
Water absorption 4.3 x 10-6 1/°k
Bulk density DIN 51045
Thermal expansion coefficient A 1 – incombustible
> 7.5 N/mm² DIN 4102 / ASTM E
Building material class 136
Bending tensile strength approx. 23000 N/mm²
Elastic modulus

Weather Resistance
Water impermeability Ok
Heat-rain-alternate test Ok EN 12467
Frost resistance Ok EN 12467
Frost-defrost-alternate test Ok EN 12467
UV-light resistance UV- and weatherproof color
pigments

Book of standards - 10
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.2 Internal wall

A. External cladding of Auditorium, Elevator facades, service cores & all sold
walls inside the podium
Manufacturer :FMG FABBRICA MARMI E GRANITI
Name of product: Onsernone; Polished & Bush hammered Granite;
Size 900 x 150 mm for both
Color: Dark Grey & Canadian pink(Autumn rose) for Elevator facade
Technical features:

PHYSICAL-CHEMICAL PROPERTIES STANDARD OF TEST REQUIRED VALUE


SIZES ISO 10545.2 Length and width ±0,6%
Thickness ±5%
Linearity ±0,5%
Wedging ±0,6%
Warpage ±0,5%
WATER ABSORPTION ISO 10545.3 ≤0,5%

FLEXION RESISTANCE ISO 10545.4 Modulus ≥35 N/mm²


Breaking strength ≥1300N
DEEP ABRASION RESISTANCE ISO 10545.6 Volume ≤175 mm³
FROST RESISTANCE ISO 10545.12 Must not produce noticeable
alteration to surface.
COEFFICIENT OF LINEAR THERMAL- ISO 10545.8 ≤9x10‾6 °C‾¹
EXPANSION
COLOR RESISTANCE TO LIGHT DIN 51094 Must not produce noticeable
colour variation.
CHEMICAL RESISTANCE ISO 10545.13 Must not produce noticeable
signs of chemical attack.
STAIN RESISTANCE ISO 10545.14 1‹X‹5
FRICTION COEFFICIENT BCRA REP Satisfactory friction
(SLIPPERINESS) CEC 6/81
FRICTION COEFFICIENT DIN 51130 Test method available
(SLIPPERINESS)

Book of standards - 11
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

(*) = The p
0,5rding to the UNI CEN standards "fully vitrified t
B. Board room
Manufacturer :Armstrong
Name of product: MetalWorks™ Custom DH700 Flat Custom Ceiling system integrated
with WH1000 Walls(Wall-to-Ceiling 90° transition)

Material
Aluminum – thickness 0.040".
Surface Finish
Painted finishes: Factory applied polyester paint
Laminates: Vinyl-faced membrane
Fire Performance - Class A fire resistant.
Painted aluminum finishes tested per ASTM E84. Flame spread Index 25 or less. Smoke
developed Index 50 orless.
CAN/ULC S102 surface burning characteristics: Flame spread Rating 20. Smoke Developed
Classification 0.
Painted Aluminum finishes CAN/ULC S102 surface burning characteristics: Flame Spread
Rating 0. Smoke developed Classification 0.
Book of standards - 12
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Laminate finish tested per ASTM E84. Flame Spread Index75 or less. Smoke Developed
Index 450 or less.

Book of standards - 13
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

C. CEO office
Manufacturer :Armstrong
Name of product: WoodWorks™ Ekos®standard Wall Panels, size 3000 x 600 mm
perforated(for board room) &unperforated (for CEO office)

Panel Material
Mineral fiber with real wood veneers. Face veneers arequarter-cut, random-matched Anigre
or Makoreveneersstained to the Ekos finishes.
Panel Surface Finish
Tinted, no-solvent coatings on face veneers.
Accessory Material
Milled solid wood stained tocoordinate with Ekosfinishes. Extruded aluminum.
Book of standards - 14
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Wall Construction
Wall construction is one layer 5/8"drywall each side of 3-5/8" metal stud, with Ekos panels
attached onone or both sides.
Fire Performance
Class B fire performance per IBC.Flame Spread Rating of 50 or less and Smoke Developed
Classification of 100 orless when tested per ASTM E84 or CAN/ULC S102.

Book of standards - 15
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

D. Auditorium
Manufacturer
:Armstrong
Name of
product:

Book of standards - 16
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

WOODWORKS® (Natural Variation) Walls panels system on Z-clips


installation with high Acoustical performance in Custom to the design
Material
FSC® -certified fire retardant particle board with face-cutveneers (SW-COC-003601).
Surface Finish
Clear or tinted semigloss coating
Fire Performance
ASTM E84 surface burning characteristics, HPVA Certifiedwith audit program per ASTM E84.
Flame Spread Index 25or less. Smoke Developed Index 50 or less.
CAN/ULC S102 surface burning characteristics. Flame spread Rating 25 or less. Smoke
developed Classification50 or less.

Book of standards - 17
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Z-clipsforpanelinstallation

Book of standards - 18
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

E. Reception
Manufacturer :Armstrong
Name of product:Soundscapes® shapes Wall panels at reception back wall
(Detail description as per the ceiling system at reception area.
See description ceiling system of entrance lobby area section -B)
Note:-
• The design shall be done in harmony with the ceiling system& coordinate with other
interior finishes.
• panels must be impact-resistant for applicationsthat need improved durability.

Book of standards - 19
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 20
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

F. Gallery/ Show room/ Telecom Museum


Manufacturer :Armstrong
Name of product:Infusions®panels (Partitions& Walls)

Material
PETG
Surface finish
Smooth
Fire Performance
Infusions panels according to NFPA 286are equivalent to Class A Interior finish as definedby the
International Building Code.

Book of standards - 21
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 22
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 23
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Interior Partition wall


a. Glass Partition wall
Manufacturer :Lindner

Book of standards - 24
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Name of product: Lindner Life 620


Size: customized to the design
• Clean lines,
• Frameless construction enhances transparency and openness of the room
• 40 mm slim connection profiles enable incorporation of dimensional tolerances,
• Integration of face – mounted acoustic elements possible
Technical information

Book of standards - 25
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 26
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Special construction Glass Partition Lindner Life


620 with digital print on site
b. Dry Partition wall
Manufacturer :MAARS JANSEN partitioning systems
Name of product: maars | styleline, 12.5 mm plasterboard panels
Color: As per the interior design
Technical specifications

DESCRIPTION Demountable decorated plasterboard faced partition.


Frame Galvanized steel studs and cross profiles.

Skirting PVC skirting.


Head tracks Recessed or steel sections. Picture hooks can be hung from the recessed head tracks.
Panels 12,5 mm plasterboard. 2 panels.
(material should be glass-fiber reinforced gypsum board).
Panel linking StyleLine Finesse: discreet V-joints without visible connectors.
Module width Up to 1200 mm with vertical divisions
Partition height 3600 mm
Partition thickness 107 mm with double cladding.

Book of standards - 27
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Weight Solid modules approximately 48 kg/m2 for double paneled partitions.


Uprights/Studs/ Cross steel sections, 0.6 mm
profiles
Internal filling mineral wool
Floor and ceiling PVC skirting
channels
Finish, color Metal partition elements, finished with a polyester-epoxy powder coating in satin or soft
touch in one of our RAL colors.
PVC components in RAL colors.
Partition cladding finished with melamine.
(All colors shall be as per interior design)

Services Services can be installed either horizontally or vertically and easily accessed for
maintenance or future alteration.
Accessories Cupboard units, ticket and sliding window units, Venetian and vertical blinds within the
sealed glass elements, picture hooks etc.
Sound insulation Double paneled partitions up to Rw 49 dB.
Fire resistance Solid paneled partitions from 30 minutes up to 60 minutes.
Integration of electrical Perforated studs provide access for wiring and other services. Demountable paneling
and data services provides easy access for installation afterwards.
Installation tolerances Floor: +/- 10 mm, Ceiling: +/- 10 mm

Book of standards - 28
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 29
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 30
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.3 SURFACE FINISH

2.3.1FLOOR FINISH
A. POOL OFFICES/ EXECUTIVE FLOOR/ CONNECTING FACILITIES/ ACCESS ROOM (DATA
CENTERS)

Manufacturer : LINDNER

Name of product: NORTEC acoustic - pool offices/ executive floor/ connecting facilities like
office, meeting with breakaway & training

NORTEC power -connecting facilities like Library

VENTEC - Access rooms (data centers)

Nortec Raised floor

NORTEC - System data

Panel Fiber-reinforced calcium sulphate panel, optionally with galvanized


steel sheet at underside, optionally with edge trim to protect against
impact and moisture
Load-bearing capacity 5 kN
Resistance to earth ≥ 106 Ω
System weight 37 kg/m² - 71 kg/m²
Standard finished floor heights 150 mm
Panel thickness 16 mm - 44 mm
Pedestal spacing 600 mm x 600 mm (other pedestal base spacing system-dependent)
Suitable floor coverings Elastic coverings / textile coverings / HPL / WOODline / STONEline /
loose-laid tiles
Fire protection
Reaction to fire performance of the panel A2/A1 (non-combustible)
Fire resistance performance F 30, REI 30 and F 60, REI 60
Sound protection
Normalised flanking level difference Dn,f,w 48 dB - 59 dB
Sound reduction index Rw 62 dB
Normalized flanking impact sound pressure level Ln,f,w 73 dB - 47 dB
Reduction in impact sound pressure level ΔLw 12 dB - 36 dB
Accessories - Expansion joints - Stringers
- Electrical outlets -Air ventilation outlets
- Facings - Intermediate floors
- Edge panels - Bridging profiles
NORTEC acoustic - Variant 4

Acoustic-effective floor panel with appropriate floor covering and acoustic element

αw = 0.65
Sound absorption class: C

System strengths

Book of standards - 31
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

 Good flanking level difference


 The use of the cavity as air duct is possible
 Excellent absorption in the frequency range of speech

NORTEC Power

Product features:

 Special panel composition - Strengthened pedestals


 Stringers are not required - Safe for driving over with heavy motorised
lifting apparatu

Book of standards - 32
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Point load 5 – 8 kN
Reaction to fire performance fully non combustible
Fire resistance performance F30 / REI 30
F60 / REI 60
Electrostatic conductivity ≥ 106 Ω
Weight of system 65 – 81 kg/m²
Floor height 150 mm
Panel thickness 40 – 44.5 mm
Pedestal grid 600 x 600 mm
Sound values
Normalized flanking level
difference D n,f,w,P 49 – 51 dB
62 dB
Sound reduction index Rw,P
Normalized flanking impact sound
pressure level Ln,f,w,P 52 – 70 dB
Reduction of impact sound pressure
Level Δ Lw,P 14 – 28 dB

Book of standards - 33
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

a) VENTEC raised Floor


VENTEC - System data

Panel Carrier panel from a welded tubular frame construction with


powder coated surface

Load-bearing capacity 3 kN - 5 kN

System weight 40 kg/m² - 43 kg/m²

Standard finished floor 70 mm – 2,000 mm


heights

Panel thickness 30 mm - 40 mm

Pedestal spacings 600 mm x 600 mm (other pedestal base spacings system-


dependent)

Suitable floor coverings Elastic coverings / textile coverings / loose-laid tiles /


coverings with perforation or suited for seepage ventilation

Fire protection
Reaction to fire performance of the panel A2, A1 (non-combustible)

Accessories - Expansion joints - Stringers


- Electrical outlets - Air ventilation outlets
- Facings - Intermediate floors
- Edge panels - Bridging profiles

Book of standards - 34
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Lindner substructures
Pedestals
- Large adjustable range, Corrosion resistant, High load-bearing capacity&Easy installation

Reinforcement profiles

Reinforcement profiles (pedestals) upgraded load bearing capacity of the flooring system.

C-profiles

System accessories

Book of standards - 35
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Electrical outlets Bridging profiles

Expansion joints Air ventilation outlets

Intermediate fl

oor for cables Facings

Book of standards - 36
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Cavity barriers

- Ventilation barriers - made from coated chipboard panels

- Fire protection barriers - made from solid gypsum wall blocks (min. 80 mm)

- Soundproofing barriers - made from porous concrete (min. 100 mm)

Floor coverings
 wood tile - for Executive floor offices

Book of standards - 37
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

 Laminated Linoleum panel - for Pool offices

 Laminated Porcelain panel - for connecting facilities

Book of standards - 38
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

B. LOBBY/ GALLERY/ SHOW ROOM/ MUSEUM

Manufacturer :FMG FABBRICA MARMI E GRANITI


Name of product: ONICE; Polished Cinderella Grey Marble with
LIPICA FUMO; Polished Dark Grey Marble
Size; 1200 x 600, 1200 x 300, 600 x 600 mmfor both
Color: Cinderella Grey & Dark Grey

Technical Features for ONICE; Polished Cinderella Grey Marble

PHYSICAL- STANDARD REQUIRED VALUE


CHEMICAL OF TEST
PROPERTIES
SIZES ISO 10545.2 Length and width ±0,6%
Thickness ±5%
Linearity ±0,5%
Wedging ±0,6%
Warpage ±0,5%
WATER ISO 10545.3 ≤0,5%
ABSORPTION

FLEXION ISO 10545.4 Modulus ≥35 N/mm²


RESISTANCE Breaking strength ≥1300N

DEEP ABRASION ISO 10545.6 Volume ≤175 mm³


RESISTANCE

FROST ISO 10545.12 Must not produce noticeable alteration to surface.


RESISTANCE

COEFFICIENT OF ISO 10545.8 ≤9x10‾6 °C‾¹


LINEAR THERMAL-
EXPANSION
COLOR DIN 51094 Must not produce noticeable colour variation.
RESISTANCE TO
LIGHT
CHEMICAL ISO 10545.13 Must not produce noticeable signs of chemical attack.
RESISTANCE

STAIN ISO 10545.14 1‹X‹5


RESISTANCE

FRICTION BCRA REP Satisfactory friction


COEFFICIENT CEC 6/81
(SLIPPERINESS)
FRICTION DIN 51130 Test method available
COEFFICIENT
(SLIPPERINESS)

Book of standards - 39
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Technical Features for LIPICA FUMO; Polished Dark Grey Marble

PHYSICAL-CHEMICAL PROPERTIES STANDARD OF TEST REQUIRED VALUE


SIZES ISO 10545.2 Length and width ±0,6%
Thickness ±5%
Linearity ±0,5%
Wedging ±0,6%
Warpage ±0,5%
WATER ABSORPTION ISO 10545.3 ≤0,5%

FLEXION RESISTANCE ISO 10545.4 Modulus ≥35 N/mm²


Breaking strength ≥1300N
DEEP ABRASION RESISTANCE ISO 10545.6 Volume ≤175 mm³
FROST RESISTANCE ISO 10545.12 Must not produce noticeable
alteration to surface.
COEFFICIENT OF LINEAR THERMAL- ISO 10545.8 ≤9x10‾6 °C‾¹
EXPANSION
COLOR RESISTANCE TO LIGHT DIN 51094 Must not produce noticeable colour
variation.
CHEMICAL RESISTANCE ISO 10545.13 Must not produce noticeable signs
of chemical attack.
STAIN RESISTANCE ISO 10545.14 1‹X‹5

FRICTION COEFFICIENT BCRA REP Satisfactory friction


(SLIPPERINESS) CEC 6/81
FRICTION COEFFICIENT DIN 51130 Test method available
(SLIPPERINESS)

Book of standards - 40
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

C. STAIRCASES AT LOBBY & CORE


Manufacturer :FMG FABBRICA MARMI E GRANITI
Name of product: NERO MARQUINIA; polished black marble with
ONICE; Polished Cinderella Grey Marble (Description as per lobby floor
finish)
Size: 1200 x 300, 600 x 600 mmfor both
Color: Cinderella Grey & Black

Technical Features for LIPICA FUMO; Polished Dark Grey Marble

PHYSICAL-CHEMICAL PROPERTIES STANDARD OF TEST REQUIRED VALUE

SIZES ISO 10545.2 Length and width ±0,6%


Thickness ±5%
Linearity ±0,5%
Wedging ±0,6%
Warpage ±0,5%
WATER ABSORPTION ISO 10545.3 ≤0,5%

Book of standards - 41
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

FLEXION RESISTANCE ISO 10545.4 Modulus ≥35 N/mm²


Breaking strength ≥1300N
DEEP ABRASION RESISTANCE ISO 10545.6 Volume ≤175 mm³

FROST RESISTANCE ISO 10545.12 Must not produce noticeable


alteration to surface.
COEFFICIENT OF LINEAR THERMAL- ISO 10545.8 ≤9x10‾6 °C‾¹
EXPANSION
COLOR RESISTANCE TO LIGHT DIN 51094 Must not produce noticeable
colour variation.
CHEMICAL RESISTANCE ISO 10545.13 Must not produce noticeable signs
of chemical attack.
STAIN RESISTANCE ISO 10545.14 1‹X‹5

FRICTION COEFFICIENT BCRA REP Satisfactory friction


(SLIPPERINESS) CEC 6/81
FRICTION COEFFICIENT DIN 51130 Test method available
(SLIPPERINESS)

D. AUDITORIUM

Manufacturer :TOUCAN-T carpet manufacture


Book of standards - 42
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Name of product: LOOP | Quadro Loop; size 4m wide


color: As per the interior design of the Auditorium

Product specification (in accordance with DIN EN 1307)

Pile material 100 % Polyamide Alto®


Surface structured Loop
Coloration Uni
Wearability commercial heavy (33) extreme
Comfort class LC 2 (good)
Characteristic features
Width 400 cm
Primary backing PP-fabric
Secondary backing synthetic textile backing
Total weight ca. 2.300 g/m²
Total height ca. 6,2 mm
Pile weight (manufacturer information) ca. 780 g/m²
Structural properties
Fire behavior Cfl-s1
Electrostatic properties ≤ 2 KV
Surface resistance ≤ 10 9 Ω
Volume resistance ≤ 10 9 Ω
Color fastness values
Light fastness ≥5
Rubbing fastness ≥ 3 / ≥ 3-4
Water fastness ≥4

Book of standards - 43
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

E. MAIN CORRIDOR
Manufacturer :FMG FABBRICA MARMI E GRANITI
Name of product: PURE LIGHT IVORY; polished Porcelain tile
Size: ,600 x 600 mm
Color: Light ivory

Technical Features for LIPICA FUMO; Polished Dark Grey Marble

Book of standards - 44
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

SPECIFICATIONS STANDARD STANDARD SPECIFICATION

DIMENSIONS ISO 10545.2 Length and width ± 0.6%


thickness ± 5%
Straightness ± 0.5%
± 0.6% squareness
flatness ± 0.5%
WATER ABSORPTION ISO 10545.3 ≤0,5%
BENDING STRENGTH ISO 10545.4 Modulus of rupture ≥35 N / mm ²
tensile strength ≥1300N
RESISTANCE TO LOW RESISTANCE ISO 10545.6 Volume ≤175 mm³

Frost resistance ISO 10545.12 Surfaces shall be free from any


breakage or damage.
LINEAR thermal expansion ISO 10545.8 ≤9x10~ 6 ° C~¹

Light resistance DIN 51094 No visible color change is allowed.

CHEMICAL RESISTANCE ISO 10545.13 Must not produce noticeable signs


of chemical attack.
Stain Resistance ISO 10545.14 1 <X <5

FRICTION COEFFICIENT BCRA REP Satisfactory friction


(SLIPPERINESS) CEC 6/81
FRICTION COEFFICIENT DIN 51130 Available procedural
(SLIPPERINESS)

Book of standards - 45
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

F. TOILET/ SHOWER

Manufacturer :RAK ceramics


Name of product: ILLUSION - floor & wall Ceramic tile
Red body - glossy - unrectified
size: 20 x 50 cm for wall 33 x 33 cm for floor
Color : IllusionWhite for all toilets, showers & kitchen
IllusionWhite&Illusion Black for Executive floor toilets, shower & kitchenette

20 x 50 cm Tiles Collection Technical Characteristics

Book of standards - 46
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Wall Tiles

Co-ordinated Floor Tiles

G. TERRACE
Manufacturer :FMG FABBRICA MARMIE GRANITI
Name of product: IMPERIAL WHITE; Granite
Size; 300 x 600 mm
Color: White
Technical Features for IMPERIAL WHITE ; Granite

Book of standards - 47
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

PHYSICAL-CHEMICAL PROPERTIES STANDARD OF TEST REQUIRED VALUE

SIZES ISO 10545.2 Length and width ±0,6%


Thickness ±5%
Linearity ±0,5%
Wedging ±0,6%
Warpage ±0,5%
WATER ABSORPTION ISO 10545.3 ≤0,5%
FLEXION RESISTANCE ISO 10545.4 Modulus ≥35 N/mm²
Breaking strength ≥1300N
DEEP ABRASION RESISTANCE ISO 10545.6 Volume ≤175 mm³

FROST RESISTANCE ISO 10545.12 Must not produce noticeable


alteration to surface.
COEFFICIENT OF LINEAR THERMAL- ISO 10545.8 ≤9x10 6‾°C ‾¹
EXPANSION
COLOR RESISTANCE TO LIGHT DIN 51094 Must not produce noticeable
colour variation.
CHEMICAL RESISTANCE ISO 10545.13 Must not produce noticeable
signs of chemical attack.
STAIN RESISTANCE ISO 10545.14 1‹X‹5

FRICTION COEFFICIENT (SLIPPERINESS) BCRA REP Satisfactory friction


CEC 6/81
FRICTION COEFFICIENT (SLIPPERINESS) DIN 51130 Test method available

Book of standards - 48
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

H. BASEMENT FLOORS
Manufacturer : DRACO ItalianaSpA
Name of product: WEPOX COLOR; pigmented epoxy resin coating
(a two-component, pigmented epoxy resin coating)
Color: Grey (or as per the interior design of basement floors)

The material should be:


High chemical resistance: to all the most common aggressive agents.
Resistance to traffic and abrasion:Superiorsurface mechanical strength with resistance to
rolling friction and scratching.
Eco-friendly waterborne formula: safe for both theenvironment and for users; good for use
in closedenvironments.
Easy to clean:Shouldcreates a waterproof and resistant coating that is easy to clean and
reduces the accumulation of dust.
Permeable to water vapor: Should creates a coating with superior
vapor permeability thus preventing blistering.
High adhesion to substrate:Should bonds strongly with concrete, thus preventing
debondingwithout the need for the substrate to be primed.

Book of standards - 49
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 50
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.3.2 WALL FINISH


I. External wall cladding
Manufacturer :FMG FABBRICA MARMI E GRANITI
Name of product: Polished or Bush hammeredwhiteLimestone;
Size 900 x 150, 600 x 150 mm for both
Color: White
Technical Features
PHYSICAL-CHEMICAL STANDARD OF REQUIRED VALUE
PROPERTIES TEST
SIZES ISO 10545.2 Length and width ±0,6%
Thickness ±5%
Linearity ±0,5%
Wedging ±0,6%
Warpage ±0,5%
WATER ABSORPTION ISO 10545.3 ≤0,5%
FLEXION RESISTANCE ISO 10545.4 Modulus ≥35 N/mm²
Breaking strength ≥1300N
DEEP ABRASION RESISTANCE ISO 10545.6 Volume ≤175 mm³
FROST RESISTANCE ISO 10545.12 Must not produce noticeable
alteration to surface.
COEFFICIENT OF LINEAR ISO 10545.8 ≤9x10 6‾°C ‾¹
THERMAL-EXPANSION
COLOR RESISTANCE TO LIGHT DIN 51094 Must not produce noticeable
colour variation.
CHEMICAL RESISTANCE ISO 10545.13 Must not produce noticeable
signs of chemical attack.
STAIN RESISTANCE ISO 10545.14 1<X<5
FRICTION COEFFICIENT BCRA REP Satisfactory friction
(SLIPPERINESS) CEC 6/81
FRICTION COEFFICIENT DIN 51130 Test method available
(SLIPPERINESS)

Book of standards - 51
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 52
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.3 CEILING FINISH


Suspended ceiling
I. For Offices
A. Board & Executive floor/ Meeting/conference/Training rooms
Manufacturer :Armstrong
Name of product: Woodworks Veneer, Plain(Unperforated)/ Perforated, Vector system,
600 x 600 mm
Material
Fire retardant particle board with face-cut veneers;FSC-certified fire retardant particle
board with face-cut veneers (SW-COC-003601).
Surface finish
Clear or tinted semi-gloss coating
Fire Performance
ASTM E84 surface burning characteristics, HPVA Certifiedwith audit program per ASTM
E84.Flame Spread Index 25or less. Smoke Developed Index 50 or less.CAN/ULC S102
surface burning characteristics. FlameSpread Rating 25 or less. Smoke Developed
Classification50 or less.
ASTM E1264 classification
Composite – Fire Class A
Veneer selection

Perforation options

• W1 - for Board & Executive floor


• W2 - for Meeting/conference/Training

Acoustical information

Book of standards - 53
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Visual selection

Accessories

WoodWork Trim Axiom® Trim

WoodWorks Trim (Wood Substrate) Installation WoodWorks Trim


(Aluminum Substrate)
Installation

Book of standards - 54
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

B. Open (pool) offices/Library


Manufacturer :Armstrong
Name of product: Optima techZone Ceiling Systems, size 1200 x 1200 mm with

15x1200mm technical panels for alternate continuous lights and


diffusers with other services for a monolithic,
uncluttered visual
Material
Fiberglass with DuraBrite acoustically transparent membrane; CAC backing
Surface Finish
DuraBrite with factory-applied latex paint
Fire Performance
ASTM E84 and CAN/ULC S102 surface burningcharacteristics. Flame Spread Index 25 or
less.Smoke Developed Index 50 or less. (UL labeled)
ASTM E1264 Classification
Type XII, Form 2, Pattern EFire Class A
Sag Resistance
HumiGuard® Plus – superior resistance to saggingin high humidity conditions up to, but not
including,standing water and outdoor applications.
Field panel color - White with no perforation

Edge Details - Optima square Tegular Technical panel

Book of standards - 55
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Visual selection

Book of standards - 56
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

II. Entrance Lobby areas


A. Reception area / Main corridors
Manufacturer :Armstrong
Name of product: Optima Radial Lay-in ortegular - size as per the design
Material
Fiberglass with DuraBrite®Outstanding acoustical performancewithacoustically transparent
membrane of NRC 0.90-0.95. With CAC backing&superior light reflectance (reduces
lighting and energy costs up to 18%). Non-directional finish, Smooth, clean, durable finish,
Washable, Impact-resistant,Scratch-resistant and Soil-resistant.Humidity-resistant
HumiGuard® Plus performance to inhibit panel sag.
Surface Finish
DuraBrite with factory-applied latex paint
Fire performance
ASTM E84 and CAN/ULC S102 surface burning characteristics. Flame Spread Index 25 or
less. Smoke Developed Index 50 or less. (UL labeled)
ASTM E1264 Classification
Type XII, Form 2, Pattern E Fire Class A
Sag resistance
Resistance to sagging in high humidity conditions
Anti Mold/Mildew & bacteria
Resistant to the growth of mold, mildew, and bacteria.
Color - white
Details -

Book of standards - 57
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 58
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 59
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

B. Lobby (2 & 3 stories high)/ Gallery/ Museum/ Show rooms/ Executive dining/ Restaurants/
Lounge/ Cafe
Manufacturer :Armstrong
Name of product: SOUNDSCAPES Shapes Acoustical Clouds(shape & color shall be decided
by the Architect)

Material
7/8" thick fiberglass with DuraBrite® scrim on face and sides or custom 1-3/4" thick fiberglass
with DuraBrite scrim on all sides (360º finishing).
Surface Finish
DuraBrite (Durable scrim) with factory-applied paint on face and sides. Standard White has
energy-saving, high light-reflective finish (LR 0.90). Back of panel is unfinished with embedded
metal extrusions.
Humidity resistance: 95% RH
Weight Substrate: 4kg/m2 Square panel with hanging frame, 6.5kg
Acoustical performance: 2.48 Sabins per panel (based on Square Panel)
Suspension System: Variety of accessory kits available for individual or group suspension or direct
attachment toplasterboard ceiling.
Fire Performance
SoundScapes Shapes panel material is ASTM E84 Class A: Flame Spread 25 or under and
Smoke Developed 50 or less.
CAN/ULC S102 surface burning characteristics. Flame Spread Rating 25 or less. Smoke
Developed Classification 50 or less.
SoundScapes Shapes, as with other architectural features located in the ceiling plane, may
obstruct or skew the existing or planned fire sprinkler water distribution pattern, or possibly
delay the activation of the fire sprinkler or fire detection system. Consult a fire protection
engineer, NFPA 13, and local codes for guidance on the proper installation techniques where
fire detection or suppression systems are present.
ASTM E1264 Classification
Type XII, Form 2, Pattern E
Acoustical Performance
1.49 Sabins per square foot or 66% more sound absorption than the same square footage of
NRC 0.90 continuous ceilings. Color shapes have slightly reduced acoustical performance.
Color selection - (As per the architects decision and the projects logo)

Book of standards - 60
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Panel selection

Book of standards - 61
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

For Restaurants, Executive dining, Lounges & Cafes

Book of standards - 62
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 63
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

For Reception areas, corridors around the lobby

For Lobby, Gallery, Show rooms & Museum

Book of standards - 64
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

C. Kitchen/ Store/ Rest rooms


Manufacturer :Armstrong
Name of product: Kitchen zoneSquare Lay-in size 600 x 600 mm
Material
Wet-formed mineral fiber
Brighter visual with 20% more light reflectance than vinyl-covered gypsum, Durable – Water-
repellent, Washable, Scratch-resistant, Soil-resistant. Smooth surface meets USDA/FSIS
guidelines for use in food processing areas.
Surface Finish
Factory-applied vinyl latex paint
Fire performance
ASTM E84 and CAN/ULC S102 surface burning characteristics. Flame Spread Index 25 or less.
Smoke Developed Index 50 or less. (UL labeled)
ASTM E1264 classification
Type IX, Form 2, Pattern G Fire Class A
Sag resistance
HumiGuard® Plus – superior resistance to saggingin high humidity conditions.
Anti Mold/Mildew & bacteria
BioBlock® Plus contains an anti-microbial treatmentand provides guaranteed resistance against
growth of mold/mildew and Gram-positive and Gram-negativeodor/stain-causing bacteria for
30 years.

Book of standards - 65
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 66
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

D. Gymnasium/Squash court/ Locker rooms/ Multipurpose rooms


Manufacturer :Armstrong
Name of product: Capz Optima - (size according to the room)

Material
Optima is fiberglass with a DuraBrite® acousticallytransparent scrim. Noise is absorbed on both
the front andback of panels (NRC 0.75 - 0.95) and High light reflectance of 0.90 - with a
standard 15/16" Prelude® XL® suspension system.
Surface Finish
Optima White has a DuraBrite finish with factoryappliedlatex paint providing superior light
reflectance.
Anti Mold/Mildew & Bacteria
Optima is inherently resistant to thegrowth of mold, mildew, and bacteria.
Color Selection - white
Cap finish colors Detail

Book of standards - 67
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 68
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

E. Changing room/ shower/ Steam/ Sauna/ Access room/Utility


Manufacturer :Armstrong
Name of product: Ceramaguard fine fissured™Square Lay-in perforated size
Material
Ceramic and mineral fiber composite. Durable, Washable, Scrubbable, Soil-resistant,
resistance to chemical fumes
Surface Finish
Scrubbable factory-applied plastic paint finish
Fire Performance
ASTM E84 and CAN/ULC S102 surface burningcharacteristics. Flame Spread Index 25 or
less.Smoke Developed Index 50 or less. (UL labeled)Fire Guard™: A fire resistive ceiling when
usedin applicable UL assemblies
ASTM E1264 Classification
High density ceramic-likecomposition with scrubbablefinish.Fire Class A
Sag Resistance
HumiGuard® Max – superior resistance to saggingin high humidity conditions including
standingwater and outdoor applications.
Anti Mold/Mildew & Bacteria
Totally inorganic product.Resistant to the growthof mold, mildew, and bacteria.
Color: White

Book of standards - 69
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

F. Auditorium/ Multi-Purpose

Manufacturer :Armstrong
Name of product: WoodWorks Access Custom Flat Ceiling Systems- Perforated; size- custom

Material
Fire retardant particle board with face-cut veneers;
Surface finish
Clear or tinted semigloss coating
Fire Performance
ASTM E84 surface burning characteristics, HPVA
Certifiedwith audit program per ASTM E84. Flame
Spread Index 25or less. Smoke Developed Index 50 or
less.CAN/ULC S102 surface burning characteristics.
FlameSpread Rating 25 or less. Smoke Developed
Classification50 or less.

ASTM E1264 classification


Composite – Fire Class A

Book of standards - 70
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

G.

H. Childcare
Book of standards - 71
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Manufacturer :Armstrong
Name of product: Cirrus® Themes (Critters, Leaves, stars, Things That Fly)–Tegular
size600 x 600 mm
Material
Wet-formed mineral fiber
surface Finish
Factory-applied latex paint
Fire performance
ASTM E84 and CAN/ULC S102 surface burningcharacteristics. Flame Spread Index 25 or
less.Smoke Developed Index 50 or less.
Anti Mold/Mildew & bacteria
It contains an anti-microbial treatmentand provides guaranteed resistance against growthof
mold/mildew and Gram-positive and Gram-negativeodor/stain-causing bacteria for 30
years.
Color: White

I. Clinic
Book of standards - 72
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Manufacturer :Armstrong
Name of product:Optima® Health Zone Square Tegular size 600 x 600 mm with Prelude
XL 15/16" suspension system

Material
Fiberglass with DuraBriteacoustically transparent membrane; CAC backing.Smooth, clean,
durable finish –Impact, Scratch, and Soil-resistant.Outstanding acoustical performance for
open plan areas, both Articulation Class (190) and NRC (0.95).Long-lasting water-
repellency, Washable and Scrubbable, Safe for use with disinfectants, Energy-saving high
light-reflective finish.
Surface Finish
DuraBrite with factory-applied latex paint
Fire performance
ASTM E84 and CAN/ULC S102 surface burningcharacteristics. Flame Spread Index 25 or
less.Smoke Developed Index 50 or less. (UL labeled)
ASTM E1264 classification
Type XII, Form 2, Pattern E, Fire Class A
Sag resistance
HumiGuard® Plus – superior resistance to saggingin high humidity conditions up to, but not
including,standing water and outdoor applications.
Anti Mold/Mildew & bacteria
Fiberglass substrate is inherently resistantto the growth of mold, mildew, and bacteria.

Details

Book of standards - 73
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Color: White

Book of standards - 74
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.4 SKYLIGHT
Manufacturer :LAMILUX CI SYSTEME
Name of product: LAMILUX CI System glass architecture PR60energysave
Size: Custom as per the design
The profile system
• Extremely stable supporting structure made of rigid aluminum
• Efficient ventilation of glass rebates
• Controlled water and condensate draining by overlapping EPDM secondary draining
• Defined glazing clamping system based on insulating spacer webs
• Elastic bedding of glass panes

Safety on the roof by CE-approved quality in line with EN 13830 (also under 2°
installation pitch)
• Water tightness against driving rain EN12154 / EN12155 /RE 1950
• Airtightness (EN12152 / EN12153 / AE 1950 Pa)
• Resistance towind load (EN13116 / EN12179/2000 Pa permissible load and 3000 Pa
increased load)
Comprehensive soundproofing
• Soundproofing demonstrated in system test in as-installed state as per EN10140-2 up to
46 dB
Energy efficiency:
• Highest passive house efficiency class
– phA advanced component
• Heat transfer coefficient UCWi0.82
W/(m2K)
• No condensate and mould formation
due to stablefRSi value of 0.79
• Low heat loss and high solarheat gain
(ψopak≤ 0.110 W/(mK))

Book of standards - 75
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 76
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.4 TRANSPORT SYSTEM

2.4.1 LIFT
Manufacturer :Schindler
Name of product:Schindler 3300 - Park Avenue type with PORT Technology

Key figures
Capacity 1125 kg - 15 passengers
Travel height Max. 75 m, max. 20 stops
One-sided entrance* 1125 kg
Door width* 1100 mm, type C2
Door height* 2300 mm
Drive system Eco-friendly gearless machine - Machine room less (MRL)
Speed 1.6 m/s
Control Push-button control; stainless steel panel with conventional layout
mechanical push buttons
Interior Style set: Square,
walls: Side wall; Santa Cruz - Laminate Capri Lemon,
Rear wall; Full mirror for core Elevators & full glass for
Panoramic Elevators
Ceiling: Line, Stainless steel Lugano Matt Finish,
Handrail: Straight, Stainless steel Brushed,
Skirting: Aluminum Anodized
Floor: Rubber speckled sand
Car door: Stainless steel Lucerne Brushed

Book of standards - 77
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Performance Security
Group operation up to three elevators Emergency power operation
One-sided entrance * Reservation and restricted access to floors:
Overload detection and visualization in car * via key switch
Two-way communication with assistance center (Telealarm) * via key card
Embedded Tele Monitoring Alarm (ETMA)* via Pin Code (Glass COP 10 key pad)
Automatic return of car to main floor Car call-by-key for parking floors
Automatic evacuation to nearest floor Automatic return to main from parking floors
Car ventilator Penthouse: visitor pick-up control
Floor lighting control Fireman’s control BR1 (EN81-73)
Building management interface Alarm horn in car or in shaft
Design Green
Square interior style sets * Regenerative PF 1 drive
Ceilings with LED lighting * Standby mode
Nameplate for stainless steel COP Automatic car light switch (on/off) *
Glass rear wall: full height Energy saving LED lighting *
Low pit VOC free (Volatile Organic Compound)
Accessibility Lubrication free gearless drive *
Push buttons with conventional keypad layout Halogen-free cabling and wiring
up to 23 floors (– 3 to 20) Shaft ventilation device
Car emergency light * Hybrid Power Manager for PV-panel connection

Book of standards - 78
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Santa Cruz
Colorful and versatile

Book of standards - 79
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 80
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.4.2 ESCALATORS

Manufacturer :Schindler
Name of product:Schindler 9300 Advanced Edition; Type 10 • 35°-K

Technical Features Transportation dimensions


Rise: max. 4.59 m
Balustrade: Design E - Slim line design
Balustrade height: 1000 mm
Inclination: 35°
Step width: 1,000 mm
Step run: 2 horizontal steps

Detail - Z

Book of standards - 81
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 82
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Book of standards - 83
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.4.3 STAIRCASES
Manufacturer :HDI Railing Systems
Name of product: Kubit ™
Materials
Stainless SteelAISI 304, 316 and 316L grade that is corrosion resistant; standard surface
preparation 240 satin finish for the handrail and post members. A bead blasted finish is
applied tothe post attachments.

Stainless Steel Handrail


Materials High quality stainless steel grade, AISI 304, 316 and 316L.
Finish Standard surface preparation 240 satin finish for the handrail.
Dimensions 38 mm outside diameter; tube wall 2 mm.
Supports Anti-corrosive marine grade AISI 304, 316 and 316L stainless steel supports.
Internal expansion clamp for handrail included. Maximum spacing1300 mm.
79.4 mm wall rosette.
Fastening Base Fastening available with secret fixing 31.75 mm diameter.
Clear space to wall is 38 mm.

Wall mounted handrail with optional rosette. Panel Link

Book of standards - 84
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Tempered Glass Infill Panels

Materials High quality stainless steel, AISI 304, 316 or 316L stainless steel.
Finish Standard surface preparation (240 satin) brushed finish for the handrail.
Infill Panel Tempered glass infill panels 9.5 mm residential or as code requires 12.7
mm commercial or as specified. Custom glass panels available upon
Top Rail request.
Posts 38 mm outside diameter;tube wall 2 mm.
Single flat 51 mm x 13 mm.
Maximum post spacing is 1524 mm for stainless steel handrail between post
Total Height centers.
Panel Link Infill Holder 914 mm handrail, 1067 mm guardrail.
Through bolt connection extended from each post for individual panels
Through Bolt Connection between single posts. Accommodates panel thickness 10 mmto 19 mm.
Through bolt connection mounted directly off of the post with cylindrical
fastening detail to accommodate for single panels between two posts.

Book of standards - 85
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Fastening Types

Core Mount
Maximum post spacing is 1524 mm between post centers for stainless
steel rail.
Concrete: minimum 150 mm thickness, 3000 psi, 76mm edge
distance. An optional cover cap can be specified for the base of the
upright to allow clean concealment of the floor finish interface.

Surface Mount
Surface mount to Concrete, If concrete thickness is more than 133
mm, then quantity (2) 13 mm anchors with 102 mm embedment are
required.3000 psi or greater concrete strength. 76 mm minimum
center line distance from slab edge.Hilti HY 150 MAX-SD chemical

Book of standards - 86
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

anchors recommended.

Two Point Side Mount


The two point side mount is connected to steel or concrete with two
attachments. Precise measurements are required for accurate
installation of the posts and glass. Maximum post spacing between
post centers is 1524 mm for stainless steel handrail.

Surface Mount

Book of standards - 87
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.5 SANITARY FIXTURES

2.5.1 WASHING BASIN


Public
Under the counter (DuraStyle for the Commercial and Office Sectors)

CEO, or other special rooms (Laufen Pro S)

Vanity unit, with space-saving siphon, for washbasin. With floor standing cabinet and soft close
mechanism drawer.

Book of standards - 88
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.5.2 TAP
Public

Self closing manual tap (Franke AQUA)


Self-closing pillar tap
AQUALINE-C self-closing pillar tap DN 15, noise
group I, for connecting to cold water or pre-
mixed warm water, flow time adjustable, all-
metal construction, polished chromium-plated
brass. WRAS approved.
AQUA203
for connection to pre-mixed warm water

CEO, or other special rooms (Laufen Pro S)

Self closing touch free automatic


Electronic washbasin tap
PROT RONIC-S battery-supplied washbasin tap with touch-
free operation, DN 15 with aerator and integrated flow
control, for connection to pre-mixed warm or cold water
supply, polished chromium-plated brass, 6 V battery. WRAS
approved.
AQUA131

2.5.3 TOILET PANS (VitrA Fresh M line)

Description
Soft closing, wall-hung, rimless (optional), Detergent dispensing tank
WC pans include a liquid cleaning tank that dispenses detergent with every flush, cleaning the
pan thoroughly and protecting against bacteria. It also shields the flushing mechanism from the
corrosive effects of cleaning agents placed in the cistern.

Book of standards - 89
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Water saving: special bowl structures and low-flow internal mechanisms, the 2.5/4 L water
conserving WC pans provide efficient flushing with less water, and are certified for the lowest
water consumption by EU standards.
Wall-hung WC pan, 56cm
COLOUR: 003 White
WEIGHT (KG): 25
MATERIAL: Vitreous china
COMPATIBLE WITH:
90-003-009 Toilet seat, soft closing

2.5.4. URINAL

Touch free Auto flush (Duravit)


Urinal with flushing nozzle: Despite low water use, the flushing nozzle provides perfect hygienic
rinsing of the surfaces. The odor trap accessible from within the basin can be replaced quickly
and easily. This version can also be combined with proven automatic infrared user detection,
including various adjustable flushing and service programs, and can be powered by battery or
mains connection.

Book of standards - 90
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.5.5. SEPARATORS ceramic(Laufen)Rion, urinal division

2.5.6 ACCESSORIES (stainless steel) (Franke)


Mirror

Book of standards - 91
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Stainless steel mirror for wall mounting


stainless steel, with a reflective polished
surface, material thickness 1 mm,
hidden thief resistant invisible fixings,
reinforced with cement polystyrene
plate, including stainless steel screws and
dowels.
390 × 290 × 7 mm (W × H × D)

Waste Bin in stall /wall mounted


Waste bin for wall mounting
stainless steel, surface satin
finished, material thickness 0.8
mm, folding self
closing lid, with integrated bag
holder, cylinder lock with
Franke standard key,
including stainless steel screws
and dowels.
capacity: approximately 16
liters, 355 × 540 × 110 mm
(W × H × D)
RODX604

Toilet roll holder


Toilet roll holder for
wall mounting
stainless steel, surface
satin finished, material
thickness 3 mm,
cylinder lock
withFranke standard
key, for 1 roll with
max. Ø 140 mm, thief
protected
spindle, controlled
paper consumption
due to spindle stop
mechanism,
including stainless steel
screws and dowels.
150 × 100 × 130 mm
(W × H × D)

Book of standards - 92
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Toilet Brush holder


Toilet brush holder for wall
mounting
stainless steel, surface satin
finished, material thickness 0.9
mm, white nylon
brush with flushing rim cleaner,
integrated drip tray, brush has
to be hooked
in, including stainless steel
screws and dowels.
135 × 235 × 135 mm (W × H
× D)

Soap dispenser Wall Mounted

Soap dispenser for wall


mounting
stainless steel, surface
satin finished, material
thickness 0.8 mm, flat
front
cover, cylinder lock with
Franke standard key,
suitable for liquid soaps
and
lotions, 0.8 litre soap
tank, plastic dispensing
handle, including
stainless
steel screws and dowels.
116 × 321 × 143 mm
(W × H × D)

Book of standards - 93
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Paper Towel Dispenser

Paper towel
dispenser for wall
mounting
stainless steel, surface
satin finished,
material thickness 0.8
mm, flat front
cover, cylinder lock
with Franke standard
key, inspection
windows on sides,
loading capacity 500
- 800 paper towels
depending on
convolution, including
stainless steel screws
and dowels.
275 × 355 × 112
mm (W × H × D)

Baby changing station (Koala Bear

stainless steel clad surface mounted horizontal baby


changing station with polyethylene interior. Full length
steel-on-steel hinges with 11 gauge steel mounting
bracket eliminating plastic wear points and providing
superior child protection and durability. Gas spring
mechanism ensures smooth open and close. Built-in
liner cavity and two bag hooks. Includes child safety
straps. Bed surface exclusively contains Microban®
antimicrobial, reducing odor causing bacteria. ASTM
compliant. Meets ADA requirements when mounted
properly. Liner dispenser holds 15 liners. Constructed
with 55% recycled materials; contributes to LEED
certified building requirements.
Interior Color is Grey.
• Unit Dimensions: 35¼” W x 20” H (892 mm x
508 mm)
• Depth (closed): 4” (102 mm) Extension (open):
19” (483 mm)
• Shipping Weight: 46 lbs

Book of standards - 94
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.5.7. SHOWER
Public
Self-closing (franke)

AQUATIMER - A3000 open shower fitting


AQUATIMER – A3000 open, electronically time-
controlled shower fitting DN 15 for in-wall installation,
with a facility for paid water delivery via AQUAPAY
coin-operated controller, and a feature for externally
controlling functions such as fitting settings and
communication via ECC function controller. 24 V DC. For
connecting to pre-mixed warm or cold water supply.
With flush mounting cabinet, watertight electronic T-
junction as well as electronic module, solenoid valve,
stainless steel cover plate with Piezo-button with
start/stop function.
Integrated control functions: Flow duration 30 sec.,
hygiene flushing.
Additional functions with ECC function controller
(Ethernet): Automatic thermal disinfection, safety switch-
off, cleaning switch-off.
AQUA605 Basic installation kit with 2000100734
adhesive flange

Book of standards - 95
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

ECC2 function controller


ECC2 function controller - A3000 open with Ethernet and
CAN bus connection for the fittings level and with
integrated power supply, real-time clock with calendar
function and WEB server. For connecting 32 AQUA 3000
open fittings/electronic system modules or up to 200 m
cable length for the purpose of supplying power and
external control, e.g. for adjusting fittings and for
communication. 230 V AC / 24 V DC.
Z-A3OP0011

AQUATIMER – A3000 open stainless steel shower


panel with thermostat
AQUATIMER – A3000 open shower panel made of
stainless steel, for on-wall installation, with electronic
time-control, thermostatic mixer and a facility for paid
water distribution via AQUAPAY coin-operated
controller and a feature for externally controlling
functions such as fitting settings and communication via
ECC function controller. 24 V DC. For connection to hot
and cold water supply. With waterproof electronic
module, solenoid valve cartridge, thermostat with metal
handle with integrated overtwist protection, Piezo-button
with start/stop function and AQUAJET-Slimline shower
head (0.2 l/s) with plastic jet plate and enclosed flow-
rate regulator (0.15 l/s). Housing made of profiled
stainless steel with plastic profile cover caps, visible
fitting parts polished chromium- plated. Integrated
control functions: Flow duration 30 sec., hygiene flushing.
Additional functions with ECC function controller
(Ethernet): Automatic thermal disinfection, safety switch-
off, cleaning switch-off.

Model with integrated tray for shower gel


AQUA614 2000101337
With InoxPlus surface finishing – easy to clean

Book of standards - 96
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Coin-operated controller for volume-dependent water


delivery
AQUAPAY coin-operated controller for volume-
dependent, paid water delivery. Volume per coin can
be set in steps of one litre from 1 – 500 litres, preset to
20 litres, maximum number of coins 30. Display for
residual volume. Residual volume is deleted after 1-30
minutes of non-use, preset to 5 minutes. Can be switched
over to unpaid water delivery. Mechanical coin tester
with opto-coupler for coins or tokens. Rugged stainless
steel housing for on-wall mounting, with safety lock and
connector for contact water meter and solenoid valve.
24 V DC
240 × 220 × 130 mm (W × H × D)
AQUA804 for tokens

CEO, or other special rooms (Laufen Pro S)

Shower tray
square edge (DuraVit)

A= 993 B=993 C=496.5 D=496.5


Shower Head(JEE-O)
Free-standing stainless steel shower.The characteristic ring or button regulates the shower
gradually from closed to open, from cold to hot.

Book of standards - 97
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.5.8.ACCESSIBLE SANITARY FIXTURES (VitraDOC-M


PACK)
PRODUCT DESCRIPTION:Doc-M Pack complete,low level boxed
PACK INCLUDES:
1 x High raised low-level WC
1 x Toilet seat, ring
1 x Low-level cistern
1 x Low-level fitting pack with espaculate lever
1 x 45cm washbasin
1 x Lever action spray mixer
5 x 60cm grab rails
1 x Hinged rail 1 x Padded back rest
1 x Chrome waste 1 x Tap hole stopper
1 x Bottle trap 1 x LANTAC approved drawing

PRODUCT DESCRIPTION:Accessible basin, 60cm


COLOUR: 003 White
WEIGHT (KG): 17.8
MATERIAL: Fine fire clay

WC pan
5422S003-5325 Cistern
PRODUCT

DESCRIPTION:WatersavingClose-coupled WC pan with raised button


Book of standards - 98
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Close-coupled cistern including fittings


COLOUR: 003 White
WEIGHT (KG): 37.8
MATERIAL: Vitreous china
COMPATIBLE WITH:77-003-009 Toilet seat, soft closing

2.5.9 GEBERIT

 Wallmountedactuator

ConcealedFlushMechanismForBacktoWallWaterCloset

Book of standards - 99
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.6.1 EXTERIOR
Glazed/ metal, partial/flush treated, handle, floor catch Automatic/ manual access/ self-closing,
scratch/wear proof, Sliding/ swing/ Overhead rolling, fire rated, smoke, weather proof, ADA & LEED
compliance

Operating Environment LOBBY ENTRANCE, Pic


RECEPTION
Factors Standard KlienRollMatic
Material Glass Flush
Leaf No 2, Double
Opening configuration Sliding
Dimensions
Thickness 12mm
Width x Height 1800mmx 3000mm
Free Dimension
Width x height
Sound Insulation (STC) 50db
Fire Label E (45 min)
Moisture Resistance RAL- Moisture room (Nr.
RG 426) 08/05-A135-K1)
Climate Class II (Nr. 08/05-A132-
Z2)
Strain Class (physical E 49mm Door
Endurance)
Radiation Protection 4mm lead equivalent
Cutout None
Edge Finish Seamless
Thickness/ weight
Surface Finish
Frame Anodized Aluminum
Fitting
Accessories
LEED Requirements Recycled Content4.1: Use materials with recycled content such that the sum
of the post-consumer recycled content plus one-half of the
preconsumercontent constitutes at least 10% of the total values of the
material in the project
Recycled Content 4.2:Use materials with recycled content such that the sum
of the post-consumer recycled content plus one-half of the
preconsumercontent constitutes an additional 10% beyond MR Credit 4.1
(total of 20% based on cost) of the total values of
the material in the project

Book of standards - 100


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Operating PARKING GARAGE


Environment
Type Commercial Rolling Service Shafts Solid Shaft: 1", 1-1/4", 1-1/2", 1-
Door 3/4", 2", 2-1/2", 3"
Mount Exterior Ring-Splits 6" Pipe: 9" Ring
Configuration Single Door Counterbalance Includes all required components
Hardware
Size 40' with Slat Restrictions Hood Type: Round; Material: Steel
Width =5000mm
Height= 2850mm
Operation Through-Wall Motor: Wall Weight 24-Gauge Steel
Mount Counterbalance
Cover
Drive Right Hand HeadPlate Cover Steel
Slat Type Large Contour Color/Finish Standard: Gray
Endlocks/Windlocks Zinc Plated Malleable Cast Miscellaneous Parts Curtain Stops, Hood Support
Iron
Material Steel Nuts/Bolts Headplate Bolts Masonry Anchors,
Hood Screws, Drive Pins
Gauge 18-Gauge Lock Locking Bars
Bottom Bar Hot-Rolled Steel Angle Weather Seal Guide Brush
Color/Finish Gray Counterbalance 1 Year or Cycle Life
Vision Panels 4" x 1" Parts 1-Year
Wear Straps Polyester Belt Jamb Constuction Steel, or Masonry
Mounting Jamb Wear Strips Polyethylene Tape (UHMW)
Guide Constuction Hot-Rolled Steel Angle Color/Finish Black, Galvanized

DuraCoil™ Optima Rolling Service Door

Book of standards - 101


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Operating Environment COURTYARD GARDEN , ROOF TERRACE GARDEN ACCESS


Factors Standard Linder Lindner T0 Recessed door
Type „D / F“, LEBO Verano 12
Material Glass Flush
Leaf No Double, single
Opening configuration Swing
Dimensions Width 1000mm
Thickness Height 2850 mm
Width x Height
Free Dimension 900mm x 2700mm
Width x height
Sound Insulation (STC) up to 43 dB for flush doors with
steel frame and retractable floor
sealing.
Fire Label E (45 min)
Moisture Resistance RAL- Moisture room (Nr. 08/05-A135-
RG 426) K1)
Burglary resistance: burglary resistance WK 3 (Nr.
(according to DIN V ENV 255_32576)
1627)
Climate Class II (Nr. 08/05-A132-Z2)
Strain Class (physical E 49mm Door
Endurance)
Climate class: Climate class II (Nr. 08/05-
132-Z3)
Cutout None
Edge Finish SeamlessLacquered edge in RAL-
and NCS-colours
Thickness/ weight 68 mm / according to quality of
glass
Surface Finish Lacquered according to RAL - and
NCS – colours
Frame Aluminium frame
Fitting Wall
Accessories optional
LEED Requirements Recycled Content4.1: Use materials with recycled content such that the sum
of the post-consumer recycled content plus one-half of the
preconsumercontent constitutes at least 10% of the total values of the
material in the project
Recycled Content 4.2:Use materials with recycled content such that the sum
of the post-consumer recycled content plus one-half of the
preconsumercontent constitutes an additional 10% beyond MR Credit 4.1
(total of 20% based on cost) of the total values of
the material in the project

Book of standards - 102


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Operating Environment FLOOR DOORS Pic


Factors Standard NYSTORM Water Tight

DOOR: Aluminum, 1/4" diamond plate, mill finish with


FRAME: A live load of 625 psf with a maximum deflection of
HINGES: L/160
PRESSURE LOCK LATCHES: Aluminum, 1/4" extrusion, mill finish
HOLD-OPEN ARM: Type 316 stainless steel
WATER TIGHT GASKET: Type 316 stainless steel
CERTIFICATIONS: Type 316 stainless steel with red vinyl grip
FLOOR DOOR SIZE: Handle
CLEAR UNOBSTRUCTED OPENING: Epdm, around entire hatch
OPENING: Tested to be water tight underApplied pressure of a 10
foot column ofWater
36" (width) x 36" (length)
LEED Requirements Recycled Content4.1: Use materials with recycled content such that the sum
of the post-consumer recycled content plus one-half of the pre-
consumercontent constitutes at least 10% of the total values of the material
in the project
Recycled Content 4.2:Use materials with recycled content such that the sum
of the post-consumer recycled content plus one-half of the pre-
consumercontent constitutes an additional 10% beyond MR Credit 4.1
(total of 20% based on cost) of the total values of
the material in the project

Book of standards - 103


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.6.2 INTERIOR
2.6.2.1 Fire
Fire rating per hour, smoke, metallic/glass, partial/solid, manual access, panic bar handle, floor catch,
swing, ADA & LEED compliance

Operating Stairway
Environment
Factors Standard
Material Steel (treated)
Leaf No Single
Opening configuration Swing
Dimensions
Width x Height 1000x2150
Free Dimension
Width x height 920 x 2110
Fire Class RE 90, REI 60
Air Permeability (Acc. to EN Class 3
1026:2001)
Thermal Resistance (Acc. to EN 2.19 W/m2K
1007-1:2007)
Water Tightness (Acc. to EN Class 3A9B
127:2001)
Resistance to windload (Acc to Class C2
EN 12211:2001)
Cutout window 300x400mm
Surface Finish Select finishing from a wide variety of RAL colours -- NDD – Ninz
Digital Decor, graphic images applied with
special ink jets and protected by a transparent topcoat.
Infinite varieties of customizable decorations in harmony
with specific door settings
Frame “Sendzimir” processed hot-galvanized sheet metal
Grooves for thermo expansive sealing and rebate sealing
Fitting Concrete wall
Accessories (MANDATORY) rubber seal FF/ CR, Nr.2 automatic door sweep
Hinges --Nr. 2 three-wing hinges for each leaf --of which one ball-
bearing hinge with screws for vertical
adjustment of the leaf, marked as per EN 1935, classified
for up to 160 kg load, 200.000 cycles durability,
suitable for fire door use --and one hinge with self-closing spring
Locking mechanism --Reversible locking mechanism with bolt and
central lock -- marked in conformity with EN 12209 standard
Handle --Fire rated handle in black plastic with steel core

Panic Bar
Closing regulator -- Two-leaved doors include an RC/STD closing
regulator to
Book of standards - 104
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

ensure the correct closing sequence of the leaves -- marking in


conformity with EN 1158 standard
LEED Requirements NONE
NystormNinzUniverFiredoors EI260-Sm (smoke control door)

2.6.2.2 Office
Solid/partial/ full, swing/sliding, handle, floor catch, wooden/glazed, manual access/ self closing,
sound insulation, ADA & LEED compliance

Operating Environment Office Main Entrance


Factors Standard
Material Aluminum , Glass
Leaf No 1
Opening configuration SLIDING
Dimensions 1800x2150
Width x Height
Free Dimension 1800x 2100
Width x height
Sound Insulation (STC) up to 37 dB Rw tested to DIN EN ISO 140-3

Fire Label EI60 tested to 13501-2


Cutout none
Fitting wall
Description designed to divide rooms through the use of a barn
door frameless glass door featuring a self-closing mechanism.
Accessories • Ideal for bathroom, bedroom or kitchen entrances, office fronts,
Surface Finish laboratories, etc.
Edge Finish • Minimalist design with a compact clear anodized track holding panels
Frame up to 10’ high.
• Innovative application allowing 8 different speed settings and
improving drastically the typical soft closing systems.
• Clipped valance for a quick installation.
• Clear opening free of floor tracks.
• Minimal gap between the door and the wall to enhance aesthetic and
acoustical features.
• Glass panels held through high weight capacity pressure clamps with
no glass drillings (use of tempered or laminated glass) for doors up to 4’-7”.
• Pre-mounted and pre-tensioned belt for a quicker and easier assembly.
Book of standards - 105
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

• Use of 3/8” and 1/2” glass doors.


• Clear anodized aluminium finish.
• Ball bearing system for quiet and soft opening.
• Wall or cilling mounted.
Systems tested up to 100.000 cycles as per European standard
EN1527.
LEED Requirements Recycled Content4.1: Use materials with recycled content such that the sum of
the post-consumer recycled content plus one-half of the preconsumercontent
constitutes at least 10% of the total values of the material in the project
Recycled Content 4.2:Use materials with recycled content such that the sum of
the post-consumer recycled content plus one-half of the preconsumercontent
constitutes an additional 10% beyond MR Credit 4.1 (total of 20% based on
cost) of the total values of
the material in the project
Lindner Plus Fire resistant door panels, Unikself KLEIN

Operating Environment Internal Office, shops show room


Factors Standard
Material glass Flush
Leaf No single
Opening configuration swing
Dimensions
Thickness Width 1000mm
Width x Height Height 2850 mm
Free Dimension 900mm x 2100mm
Width x height

Operating Meeting and exec level offices


Environment
Factors Standard
Material Wood flush w glazed
opening
Leaf No Single, double

Book of standards - 106


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Opening configuration swing


Dimensions T= 42mm
Thickness Width 1000mm
Width x Height Height 2850 mm
Free Dimension 900mm x 2100mm
Width x height
Operating Environment Toilets
Factors Standard
Material Wood flush
Leaf No Single, double
Opening configuration Sliding
Dimensions T= 42mm
Thickness Width 1200mm
Width x Height Height 2850 mm
Free Dimension 1000mm x 2100mm
Width x height
General Standards
Factors Standard
Sound Insulation (STC) up to 32 dB Rw (= laboratory value)
Valid for flush doors with steel frame and
retractable floor sealing.
Fire Label
Moisture Resistance (according to RAL-RG 426) Moisture room (Nr. 08/05-A135-K1)
Wet room (Nr.08/05-A135-K2)
Climate Class Climate class II (Nr. 08/05-A132-Z1)
Strain Class (physical Endurance) Class S (Nr. 03/08-1257)
Cutout Frame width 160 mm (Optional)
Edge Finish o Lacquered edge in RAL- and NCS-colours
Thickness/ weight ca. 42 mm / ca. 23 kg/m2
Surface Finish Veneered, stained, transparent laqcuered
Frame Aluminium frame
Fitting Wall
Plasterboard partition
Accessories Standard Lever handles, hinges, locks, door
opener etc.
LEED Requirements Recycled Content4.1: Use materials with recycled
content such that the sum of the post-consumer
recycled content plus one-half of the
preconsumercontent constitutes at least 10% of
the total values of the material in the project
Recycled Content 4.2:Use materials with
recycled content such that the sum of the post-
consumer recycled content plus one-half of the
preconsumercontent constitutes an additional
10% beyond MR Credit 4.1 (total of 20%
based on cost) of the total values of

Book of standards - 107


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

the material in the project


Equivalent materials Linder wooden door type A, Lightline 1 Lebolit
Beech with glass “Pave”

Operating Exec room


Environment
Factors Standard
Material Wood flush
Leaf No Single
Opening configuration Sliding
Dimensions T= 42mm
Thickness Width 1200mm
Width x Height Height 2850 mm
Free Dimension 1000mm x 2100mm
Width x height
Sound Insulation (STC) Up to 42 dB Rw (= Laboratory value) = 68 mm door leaf
Sound insulation values are achieved in steel frame
Moisture Resistance o Moisture room (Nr. 08/05-A135-K1)
Climate Class Climate class II (42 mm: Nr. 08/05-A132-Z1,
Strain Class (physical Class S for 42 mm doors (Nr. 03/08-1257)
Endurance)
Cutout none
Edge Finish Solid wood inset edge band
Thickness/ weight ca. 42 mm / ca. 23 kg/m² to ca. 38 kg/m²
Surface Finish Veneered, transparent lacquered
Frame Steel frame (one- and two-piece)
Fitting Plasterboard partition
Accessories Standard: Lever handles, hinges, locks, door opener etc.
LEED Requirements Recycled Content4.1: Use materials with recycled content such that the
sum of the post-consumer recycled content plus one-half of the
preconsumer
content constitutes at least 10% of the total values of the material in
the project
Recycled Content 4.2:Use materials with recycled content such that the
sum of the post-consumer recycled content plus one-half of the
preconsumer
content constitutes an additional 10% beyond MR Credit 4.1 (total of
20% based on cost) of the total values of
the material in the project
Linder Sliding Door Type S/ KlienUnikGlass

Book of standards - 108


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.6.2.3 Utility

Metallic, fire rating, manual access, partial/full, handle, floor catch, scratch/wear proof, sliding, ADA &
LEED compliance

Operating Environment Kitchen, Kitchenette, Storage, General Store, Archive, MEP Room,
Technical room/ Shaft, Cold Store
Factors Standard
Material Steel
Leaf No 1,2
Opening configuration swing
Dimensions
Thickness Width 1000mm
Width x Height Height 2850 mm
Free Dimension 900mm x 2100mm
Width x height
Sound Insulation (STC) up to 42 dB Rw (= laboratory value)
Valid for flush doors with steel frame and retractable floor
sealing.
Fire Label according to DIN EN 1634:
T30 / EI2 30 C5)
Moisture Resistance (according to RAL-RG o Moisture room (Nr. 08/05-A135-K1)
426) o Wet room (Nr. 08/05-A135-K2)
Strain Class (physical Endurance) Class E (Nr. 03/08-1258)
Cutout none
Edge Finish Lacquered edge in RAL- and NCS-colours
Thickness/ weight ca. 49 mm /ca. 37 kg/m²
Surface Finish Lacquered according to RAL - and NCS – colours
Frame Steel frame (one- and two-piece)
Book of standards - 109
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Fitting wall
Accessories standard :Lever handles, hinges, locks, door opener
LEED Requirements Recycled Content4.1: Use materials with recycled content
such that the sum of the post-consumer recycled content plus
one-half of the preconsumer
content constitutes at least 10% of the total values of the
material in the project
Recycled Content 4.2:Use materials with recycled content
such that the sum of the post-consumer recycled content plus
one-half of the preconsumer
content constitutes an additional 10% beyond MR Credit
4.1 (total of 20% based on cost) of the total values of
the material in the project
Lebo Luana 1, LA Lock Sided, 1 Big LA,

2.6.2.4 Wet Area

Moisture resistance, thermal resistance, metallic/ wooden/ treated glazed, flush, sliding, manual access,
handle, ADA & LEED compliance

Operating Environment Changing, Massage, shower Rooms, Steam and Sauna Rooms
Factors Standard
Material Glass
Leaf No single
Opening config. Sliding/ swing
Dimensions Width 1000mmx Height 2850 mm
Free Dimension (WxH) 900mm x 2100mm
Sound Insulation (STC) up to 38 dB Rw (= laboratory value)
Valid for flush doors with steel frame and retractable floor sealing.
Moisture Resistance Moisture room (Nr. 08/05-A135-K1)
(RAL-RG 426) o Wet room (Nr.08/05-A135-K2)
Climate Class Climate class II (Nr. 08/05-A132-Z1)
Strain Class Class S (Nr. 03/08-1257)
Cutout none
Edge Finish Lacquered edge in RAL- and NCS-colours
Thickness/ weight ca. 42 mm / ca. 35 kg/m2
Book of standards - 110
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Surface Finish Glass, Lacquered according to RAL - and NCS – colours


Frame Aluminium frame
Fitting Wall
Accessories Standard: Lever handles, hinges, locks, door opener
LEED Requirements Recycled Content4.1: Use materials with recycled content such that the sum of
the post-consumer recycled content plus one-half of the preconsumercontent
constitutes at least 10% of the total values of the material in the project
Recycled Content 4.2:Use materials with recycled content such that the sum
of the post-consumer recycled content plus one-half of the
preconsumercontent constitutes an additional 10% beyond MR Credit 4.1
(total of 20% based on cost) of the total values ofthe material in the project
KLEIN UNIKGLASS, Lindner Object door type “B”

2.6.2.5 Sound

Sound insulation, wooden/ glazed, flush/ partial/ treated, handle, automatic/ manual access,
sliding/swing, ADA & LEED compliance

Operating Environment Auditorium Entrance


Factors Standard
Material KLEIN UNIKGLASS, Lindner Object door
type S, Lebolit Nature Oak Anthracite
Luana Metal 18, Linder Object Door Type E,
Leaf No 2, 1
Opening Swing
configuration
Dimensions Width 1000mmX 1900x2150
Height 2850 mm
Free Dimension 900mm x 2700mm
Width x height 1820 x 2110
Operating Environment Back stage rooms
Factors Standard
Material KLEIN UNIKGLASS, Lindner Object door
type S, Lebolit Nature Oak Anthracite

Book of standards - 111


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Luana Metal 18, Linder Object Door Type E,


Leaf No 1
Opening Swing and sliding
configuration
Dimensions Width 1000mmX 1900x2150
Height 2850 mm
Free Dimension 900mm x 2700mm
Width x height 1820 x 2110
Operating Environment Lounge, Bar, Exec dinning, Staff Canteen
Factors Standard
Material KLEIN UNIKGLASS, Lindner Object door
(equivalent ) type S, Lebolit Nature Oak Anthracite
Luana Metal 18, Linder Object Door Type E,
Leaf No 2, 1
Opening Swing and sliding
configuration
Dimensions Width 1000mmX 1900x2150
Height 2850 mm
Free Dimension 900mm x 2100mm
Width x height 1820 x 2110
General standard
Factors Standard
Sound (STC) 52dB
Fire Label according to DIN EN 1634:
T30 / EI2 30 C5)
Climate Class Climate class II (Nr. 08/05-A132-Z1)
Strain Class Class E (Nr. 03/08-1258)
Cutout none
Edge Finish seamless
Surface Finish Glass, Lacquered edge in RAL- and NCS-colours
Frame Aluminium frame
Fitting Wall
Accessories Standard: Lever handles, hinges, locks, door opener
LEED Requirements Recycled Content4.1: Use materials with recycled content such that the sum of the
post-consumer recycled content plus one-half of the preconsumercontent
constitutes at least 10% of the total values of the material in the project
Recycled Content 4.2:Use materials with recycled content such that the sum of the
post-consumer recycled content plus one-half of the preconsumercontent
constitutes an additional 10% beyond MR Credit 4.1 (total of 20% based on
cost) of the total values of
the material in the project

Book of standards - 112


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.6.2.6 Security
Metallic, flush, durability, sound insulation, fire rated, automatic access, ADA & LEED compliance

Operating Environment GENERAL SECURITY OFFICES


Factors Standard
Material AssaAbloy: Ceco Doors, RestrictDor™
Security Door and Frame System
Leaf No 1
Opening config. swing
Dimensions W xH 1219 mm x 2438mm)
Free DimensionWxH 1000mm x 2300mm
Features • 2" (50.8mm) thick custom construction seamless design rated forExtra Heavy-
Duty or Maximum duty, interior or exterior use
• Extra strong 18 gauge (1.0mm) vertical steel stiffeners placed4” (101.6mm)
apart and welded to the face sheets every3-1/2” (88.9mm) along their
length.
• Fully welded vertical edge seams for enhanced strength and
aesthetic appearance
• Fiberglass batt insulation between stiffeners to limit thermal and
sound transmission
• Lock and hinge edge beveled 1/8" in 2" (1:16)
• 12 gauge (2.3mm) closer reinforcement
• 10 gauge (3.1 mm) inverted steel end channels welded to both
face sheets
• 7 gauge (4.2 mm) steel hinge reinforcement
• Neutral prime base coat
option Galvannealed or galvanized steel
surface Seamless, 14 guage finish
Physical Endurance Level A (1,000,000 cycles)
(Cycle Testing)
Fire Rating according to DIN EN 1634:
T30 / EI2 30 C5)
LEED Req. none

Book of standards - 113


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.7 INTERIORS

2.7.1 INTERIOR SEATING CUM GREENERY


Manufacturer: OFFECT
Name of Product: Green Islands
Application: In public spaces or waiting areas i.e. lobbies, gallery, or corridor as deemed
necessary.
Material: Frame (Ø 160 cm or
148 x 148 cm) in plywood and
solid wood with cold foam
wrapped in flameproof fiber.
Upholstered in fabric or leather
incl. flowerpot.

Book of standards - 114


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

2.7.2 INTERIOR VEGETATION

LOBBY AREA
• Structure must support 10 LB/SQFT saturated GSKY versa wall system gravity weight.
• Adequate lighting must be designed and installed min 15 0 foot candles even flood 4.300K
color temp, metal Halide recommended

Book of standards - 115


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

3.STRUCTURAL
Book of standards - 116
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

3.1General
TheEthioTelecomHeadQuarterBuildingisacomplexbuildingcoveringbuildablearea of
about200,000m2consistsof18blockseachseparatedbymeansofexpansionjointsandgroupedintosevent
ypologicalBlocksasshown inFigure4.1.EachBlockgroupisexplainedbelow:

Block A
Thisblockgroupconsistsoffivesimilar referredtoasBlockA1,A2,A3,A4&A5, on
axesEtoMinthelongitudinaldirectionandaxes2-3-4BlockA1;axes9-10-11Block A2;axes16-17-
18BlockA3;23-24-25BlockA4and30-31-32BlockA5inthetransverse
direction,respectively.These blocksareisolatedfromthe adjoining building
blocksbymeansofexpansionjointssothatnoloadeffectfromtheotherstotherespective
blockcomponentwouldbetransferredoritseffectwillbeaffectinganyotherblockadjacent
toeach.Theblocksassume2B+SB+10 storiesandRCroofslab.

Block B
Theblock groupunderthisconsistsoffourblocksofitsduplicatereferredtoasBlock B1,B2,B3&
B4,onaxesLtoMuptoGroundfloorandL-kabovethegroundinthe longitudinaldirectionandaxes4’-
8’BlockB1;axes11’-15’BlockB2;axes18’-22’
BlockB3and25’-29’BlockB4inthetransversedirection,respectively.Theseblocksare
alsoisolatedfromthe adjoining building
blocksbymeansofexpansionjointsinsimilarmannertotheblock
Agroup.Theblocksassume2B+SB+9storeyandRCroof slab,andareslightlycurvedinplan.

Block C
ThisTheblockgroupunderthisconsistsoffourblocksofitsduplicatereferredtoas BlockC1, C2,
C3&C4,onaxesEtoGuptoGroundfloorandE-Fabovethegroundin
thelongitudinaldirectionandaxes4’-8’Block C1;axes11’-15’Block C2;axes18’-22’
BlockC3and25’-29’BlockC4inthetransversedirection,respectively.Theseblocks
arealsoisolatedfromthe adjoining building
blocksbymeansofexpansionjointsinsimilarmannertotheblockBgroup.Theblocksassume
2B+SB+10 storiesandRCroofslabandareslightlycurvedinplan.

Block D
ThisblockisasinglelongblockreferredtoasBlockD,onaxesAtoD’inthe
longitudinaldirectionandaxes2-11’in the
transversedirection.Thisblockisalsoisolatedfromtheadjoining building
blocksbymeansofexpansionjointsinsimilar
mannertotherestofthebuildingblocks.TheblockassumespartlySB+G+ 2 stories
andRCroofslab.

Block E
Thisblockisasingle,longblockreferredtoasBlockE,onaxesCtoD’inthe
longitudinaldirectionandaxes11-
22’inthetransversedirection.Thisblockisalsoisolatedfromtheadjoiningbuildingblocksbymeansof
expansionjointsinsimilar
mannertotherestofthebuildingblocks.TheblockassumespartlySB+G+2stories andRCroofslab.
Block F
ThisTheblockgroupunderthisconsistsoffourblocksofitsduplicatereferredtoas
BlockF1,F2,F3&F4,onaxesHtoJ’andfallshortofthegroundfloorinthe
Book of standards - 117
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

longitudinaldirectionandaxes4’-8’BlockF1;axes11’-15’BlockF2;axes18’-22’ BlockF3and25’-
29’BlockF4inthetransversedirection,respectively.Theseblocks are alsoisolatedfromthe
adjoining building
blocksbymeansofexpansionjointsinsimilarmannertotheblockBgroup.Theblocksassume2B+SBa
ndRCroofofground slabandareslightlycurvedinplan.

Block G
ThisblockisasinglelongblockreferredtoasBlockG,onaxesCtoD’inthelongitudinaldirectionandax
es22-32inthetransversedirection.Thisblockisalso
isolatedfromtheadjoiningbuildingblocksbymeansofexpansionjointsinsimilar
mannertotherestofthebuildingblocks.TheblockassumespartlySB+G+2stories andRCroofslab.

The height ofthestructure range from10.76 m to54.48m including basement floor

Book of standards - 118


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

3.2CodesandStandards

ThedesignCodesusedandtobeusedbythestructuralengineertodetermineloadsonstructureareEuroCode
(EC-2010)andupdated version oftheEthiopianBuildingCodesofStandards(EBCS-
2013,Draft).AstheEuroCodeswillbeimplementedtotheEthiopianpracticewithinthenext couple of
years, the report shall make use of the Euro Codes
wheneverpossible.However,withlimitedguidance on
procedures,alternativecodessuchasACIwillbeusedtofillthegapwithproperexplanationandadjustmentt
o suit tothebasestandards.

3.3 Depth and Extent of Preliminary Design

Theobjectiveofthispreliminarydesignistoprovidethebasisforthefinalanddetaildesign ofthebuilding
complex.

The preliminary design islimitedtoonetypicalblockdetailsofwhichto be addressedinthe


finaldesign.Staticalcalculationusingtheselectedinitialcrosssection
dimensionhasbeencarriedincludingdesignanddrawingofrepresentativestructuralmembers. Thedetail
design fortheselectedbuildingusingcorrected/adjusteddimensionofmembersandfortherest of the
blocksshallbeaddressedinthe finaldesignbythedesignandbuildContractor.

3.4StructuralSystemRequirements
The structuralarrangement in the finaldesignshallbemade in a mannerthat it can transmit
allloadsconsistingofdead,wind&imposedloadsinadirectmannertothefoundation.
Lateralstabilityinthetwoorthogonaldirectionsshallbeprovidedbyasystemofstrong
pointswithinthestructuresoastoproduceabracednon-
swaystructureinwhich,thestructuralformandframingshallassumethefollowing:

 Simplearrangementofslab/beamsandcolumnssothatloadsarecarriedtothe
foundationsbytheshortest andmostdirectroutes,
 Thecolumnsarenotsubjectedtosignificantswaymoments,
 Strong pointsprovidedbythecorewallsenclosingthestairs,liftsandsurfaceducts,
 Additionalstiffnessprovidedbyshearwalls,
 Thecoreandshearwallsdistributedthroughoutthestructuralframeworksoarranged
thattheircombinedshearcenterislocatedapproximatelyonthelineoftheresultantinplanoftheapp
liedoverturningforces.Inasituationwheretheabovepointisnotpossible,theresultingtwistingmome
ntsshallbeconsideredwhencalculatingtheload carriedbyeachstrong point.
 Strong pointsshallbemadeeffectivethroughoutthefullheightofthebuilding
 Where a building structure is divided by expansion joints, each part should be
structurallyindependentanddesignedtobestableandrobustwithoutrelyingonthestabilityofadja
centsections.

Book of standards - 119


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

3.5Materials
The
structuralmaterialusedismainlyconcreteandreinforcingsteel,specifiedbythecharacteristiccubestrength
at28thdayofageandsteelreferredbyitsyieldstrength.ThedesignequationsneverthelessrefertoConcret
ecylinderstrengthfck,andcharacteristicyieldstrength ofreinforcement,fyk.
Partialfactorsforconcreteare 1.5 forultimatelimit state and
1.0forserviceabilitylimitstates.Thepartialfactorsforreinforcementsteelare1.15for
ultimatelimitstate and1.0forserviceability limit state.

Concrete: Forallmainstructuralframeworkofthebuildingconsistingofslab,stair,
beams&foundationfootings,concretefck=24MPa(cylindercrushingstrengthattheageof
28days,cubeC-30)shallbeused.ForColumnsandshearwalls–Concreteclasscorresponding
tofck= 40 MPa(C-50)or,fck= 32MPa(C-40)shallbeused.

ReinforcingSteel: YieldStrengthfyk= 400MPaor largerforall barswithφ≥10mm


YieldStrengthfy=300MPa,otherwise

3.6Loading

3.6.1 Gravity Loading

LoadsandloadcombinationshallbebasedinaccordancetoEthiopianbuildingCodeStandardEBCS
1,2013,Draft(orEuroCodeEC-2010).TheLiveloadingsonfloorsshallbe in accordance with function
oftheparticularfloor.

Forself-weightanddeadloads,weightsfrommaterialpropertiesandweightsoftheitemsinconsideration
shallbeusedfortheactualcalculations.

Forliveloadsthe following shallbe in useforthedesignofthebuildingcomplex:

CategoryA: Areas fordomesticand residential activities - Rooms in


residentialbuildingsandhouses;bedroomsandwardsinhospitals;bedroomsinhotelsandhoste
lskitchensandtoilets.
CategoryB: Office areas
CategoryC: Areaswherepeople maycongregate(with the exception
ofareasdefinedundercategoryA,B,andD1))
 C1:Areaswithtables,etc.e.g.areasinschools,cafés,restaurants,dining
halls,readingrooms,receptions.
 C2: Areas withfixedseats, e.g. areas inchurches, theatres or cinemas, conference
rooms,lecturehalls,assemblyhalls,waitingrooms,railwaywaitingrooms.
 C3: Areas withoutobstacles for moving people, e.g. areas inmuseums,
exhibitionrooms,etc.andaccessareasinpublicandadministrationbuildings,
hotels,hospitals,railway station forecourts.
C4:Areaswithpossiblephysicalactivities,e.g.dancehalls,gymnasticrooms, stages.
 C5:Areassusceptibletolargecrowds,e.g.inbuildingsforpubliceventslikeconcerthalls,
sportshallsincludingstands,terracesandaccessareasandrailwayplatforms.

Book of standards - 120


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

CategoryD:Shoppingareas
 D1:Areasingeneralretailshops
 D2:Areasindepartmentstores

Table2.1-Imposed loadsonfloors, balconiesandstairsinbuildings


Categoriesofloadedareas qk Qk
[kN/m2 [kN]
Category A
-Floors 1.5 to2.0 2.0 to 3.0
-Stairs 2.0 to4.0 2.0 to 4.0
-Balconies 2.5 to 4.0 2.0 to 3.0
Category B 2.0 to 3.0 1.5 to 4.5

Category C
-C1 2.0 to 3.0 3.0 to 4.0
-C2 3.0 to 4.0 2.5 to 7.0(4.0)
-C3 3.0 to 5.0 4.0 to 7.0
-C4 4.5 to 5.0 3.5 to 7.0
-C5 5.0 to 7.5 3.5 to 4.5
Category D
-D1 4.0 to 5.0 3.5 to 7.0(4.0)
-D2 4.0 to 5.0 3.5 to 7.0

Forthepermanentloads,loadingmaybecomputedonthebasisofunitweightandunitvolumeofthematerialu
singthedimensionsspecifiedinthepreliminarydesignandtobe specifiedinthe finaldesign.

3.6.2LateralLoading
Thefirstandmostimportantlateralloadto be
addressedistheearthquakeloadingwhichisdependentthegeographicallocationofProjectsite.Inthisrega
rd,theBuildingsiteisAddisand the coefficient associated with the bed rock acceleration is to be
considered in accordance with the provision andrequirementsofdraftEBCS-8,2013.Suchloading
combined with functionalloadingshallbecheckedforeverymemberoftheframeworkconsisting of
beams,columnsandshearwall.

3.6.3AnyOtherLoading
Otherloadsexhibitedincludelateralloadconsistingoftheearthpressuretotheframedretainingwallcomm
encingfromtheNaturalgroundtothesecondbasementlevel,whichisassumedto be the pressure
ofwhichisdistributedlinearlyassumingpeak at the bottom.The
pressureistobecomputedinaccordancewiththeprovisionofEBCS-7,2013usingeither
RankinsorCoulombsdistributioncoefficient.
Windmay be consideredforthecladdingandforthe glazing supporting frameandanyprojection
butlightstructure with largepanel.

3.7Sub-structure–FoundationTypeandPreliminaryDimensions

Book of standards - 121


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Thefoundationinthepreliminarydesignisestablishedusingthehistoryofthebuildingsin the
neighborhoodofthe Tele Building site. Accordingly, the site possess a subsoil of
weatheredrockat a depth not more than 6 m from the naturalgroundlevel,
detailsofwhichtobeconsideredafterthesoilandthegeotechnicalinvestigationistobecarriedout.Asperthei
nvestigationreportandsitefindings,thefinaldesignerisexpectedtoexamintheinformation from the
groundinvestigationanddecideson the type
offoundationtobeusedinthefinaldesign.Inthisregard,thedesignerisexpectedtoconsiderespeciallyanye
xistingoffuturestructureadjacenttotheperimeterofthebuildingstructuresthatmayinfluencenotonlytheloc
ationofthefoundationbutalsoanypossibleeffectonthesuperstructureand adjacent buildings.

Asinthepreliminarydesign,thefollowinghasbeenselected, subject
tomodificationinthefinaldesignafterdetailfindingsofthesuperstructure effect andsubsoilinvestigation.

Block A, Block B and Block C aremultistorybuildingsof up to level 10, the


loadingstransferredthroughthecolumnsofconsiderabledegree,andhenceareselectedtohaveMATtype
foundation forbothbearingsandstabilityreasons.

BlockD,E,FandGareoflowerstoreywhoseloading onsupportingcolumnsarenotsubstantial. In viewof


strong subsoil, isolated footings are most economical and safe. However,duetotheprovision of
expansionjoints,thefootingsattheboundarytoadjacentblockmayneedtobetiedtothenearbyfootingofth
esamebuildingblockbymeansofstraporcombinedfootingwouldbetheotheroption,
detailsofwhichtobeconsideredinthefinaldesign.

3.8StructuralAnalysis

Structuralmodelling

 Calculationsshallbecarriedoutusingappropriatestructuralmodelsinvolving relevant variables.


 Thestructuralmodelsselectedshouldbethoseappropriateforpredictingstructural
behaviorwithanacceptablelevelofaccuracy.Thestructuralmodelsshouldalsobe
appropriatetothelimitstatesconsidered.
 Structuralmodelsshallbebasedonestablishedengineeringtheoryandpractice.If
necessary,theyshallbeverifiedexperimentally.

Book of standards - 122


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Staticactions

 Themodelingforstaticactionsshallbebasedonanappropriatechoiceoftheforce- deformation
relationships of the members and their connections and between membersandtheground.
 Boundary conditions applied to the model shall represent those intended in the structure.
 Effectsofdisplacementsanddeformationsshallbetakenintoaccountinthecontext
ofultimatelimitstateverificationsiftheyresultinasignificantincreaseoftheeffectofactions.

Indirect actionsshallbeintroducedinthe analysisasfollows:


−inlinearelasticanalysis,directlyorasequivalentforces(using appropriate modularratioswhere
relevant);
−innon-linearanalysis,directlyasimposeddeformations.

Dynamicactions

 The structuralmodelto be usedfordeterminingthe action effectsshallbe established


takingaccountofall relevant
structuralmembers,theirmasses,strengths,stiffnessesanddampingcharacteristics,andallreleva
ntnonstructuralmemberswiththeirproperties.
 Theboundary conditions applied to the model shall be representative of those
intendedinthe structure.
 Whenitisappropriatetoconsiderdynamicactionsasquasi-
static,thedynamicpartsmaybeconsideredeitherbyincludingtheminthestaticvaluesorbyapplyin
gequivalentdynamicamplificationfactorstothestaticactions.
 In the case of ground-structure interaction, the contribution of the soilmay be
modeledbyappropriateequivalentspringsanddash-pots.
 Whererelevant(e.g.forwindinducedvibrationsorseismicactions)theactionsmay
bedefinedbyamodalanalysisbasedonlinearmaterialandgeometricbehavior.Forstructurestha
thaveregulargeometry,
stiffnessandmassdistribution,providedthatonlythefundamentalmodeisrelevant,anexplicitmod
alanalysismaybesubstituted byananalysiswith equivalent staticactions.

Thedynamicactionsmaybealsoexpressed,asappropriate,intermsoftimehistoriesorinthe
frequencydomain,andthestructuralresponsedeterminedbyappropriate methods.
Wheredynamicactionscausevibrationsofamagnitudeorfrequenciesthatcould
exceedserviceabilityrequirements,aserviceabilitylimitstateverificationshouldbe carriedout.

Firedesign: The structuralfiredesign analysisshallbebasedondesign firescenarios(seeEBCS


EN1991-1-
2:2013),andshallconsidermodelsforthetemperatureevolutionwithinthestructureaswellasmodelsfo
rthemechanicalbehaviorofthestructureat elevatedtemperature.

Furtherdetailsandguidelinesareprovidedinthe following documents:


1. TechnicalSpecifications
2. PreliminaryStructuralDesignReport
3. StructuralDrawings

Book of standards - 123


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

4. SANITARY
Book of standards - 124
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

STANDARDSANDCODESOFPRACTICE
Sanitaryandplumbingdesigninvolvesinwatersupplysystem,wastewatercollection,disposalw
ithtreatmentsystem,stormwaterdrainageanddisposalsystemandsubsurfacedrainagecollect
ionsystemfromthebuildingandthecompoundshallcomplywiththerequirementsofpertinentSta
ndardsandCodesofpractice.TheseincludeEBCS1995,BS
5572-1978,BS301-1985&AS3500.2-1990forwastewaterdrainage,BS6700-
1987forwatersupplyandBS6367-1983fordrainageofroofsandpavedareas.

4.1.WATERSUPPLYSYSTEM
DOMESTICWATERSUPPLYSYSTEM

Thedomesticwatersupplytothewholecompoundistobemademainlyfromthemunicipalwatersystemorbor
eholesatthevicinity.Initiallywaterisstoredingroundwaterreservoirandpumpedtoelevated/roof/watert
anksorwheresufficientpressureisattaineddirectsupplyismadefromgroundwaterreservoir.

Alternatelythesupplytoeachfixturecanbedonethroughboasterpumpswithpressurevesselsconnections

Pipesshallbelaidoverrooftops,withinanenclosedarea,orfromwatertanksupporttowersanddropvertica
llydowntodrawoff(outletPoints.)Pipesshallhavetobelaidwithinfloorslabs(inducts),wherefloor-
mountedequipmentistobesupplied.

4.1.1 internal
PIPES,FITTINGS,ACESSORIES
ColdandhotwaterpipesshallbePolypropyleneRandomCo-
polymerresins(PPType3rawmaterial)PPR,PN-
20pipesforcoldandhotwater,andbefixedtoslabs,walls,beamsoretc…withmetalstrapsorsimilarma
terial.

ThepipeshallcomplytoDIN8077,DIN8078,DIN1988,DIN16960,DIN16962etc.Oritsequivalent.

Allfittingsandaccessoriesofwaterpipeinstallationsshallbeofthesamequalityifnothighersideandprov
idedwithmetallicinsertionformetalvalvesandgadgetsinstallations

Theconnecxtioneffectedbythermalfusionusingrecommendedmachines

VALVES,TAPSANDFAUCETS

Book of standards - 125


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

chromeplatedbrassquarterturnanglevalveswithchromeplatedcopperconnectingpipe,unionnutandc
hromeplatedbrasswallflanges,andaccessoriescompleteinallrespects.TheAnglevalveshouldbecapa
bleresistingofPN-10beforehandwashbasins,waterclosetsandotherfixtures.

bronzeandbrassmadegatevalvescompletewithunions,elasticwaterproofing,handwheelsandallthen
ecessaryaccessoriesorapprovedequalusedwithPN=16AllvalvesshallbecompatibletoPP-Rpipes

Uptoandincluding50mm:Bronzebody,bronzetrim,risingstem,handwheel,insidescrew,singlewedgeor
disc,solderendsasappropriate.flangedends.

DISINFECTION,TESTINGANDCOMMISSIONING

Flushing,disinfectingandtestingandcommissioningofwatersupplysystem.Flushinghastobedonetocleant
hepipelinefromdebrisandsilts.Disinfectinghastobedonewithliquidchlorin8-
10ppm.Allwaterpipesshallbetestedwithpressureof10kg/cm(10bar).asperWHOguidelines

4.1.2 EXTERNAL
PIPES,FITTINGS,ACESSORIES

IfthewatersourceforthesiteistheAAWSSAwatersupplyservicelinetheservicepipefromthetownmainlinebr
anchesbydiameter100mmHDPEtypepipeused,whichdirectlyfillsthewaterreservoirandregulatedbyfloa
tvalveinthereservoirandalsodirectlysuppliesthesystembybypasslinesothesizingwillbedesignedbythisco
nsideration.

externalUVexposedwaterpipesshallbeHighDensityPolyethylene(HDPE),PN-
10pipes,andbelaidonroofandUnitpriceshallincludeallassistancecivilworksandnecessaryfittingssuc
hasT,bendsetc.accordingtowhereshownonthedrawing.Allasperdetails,toISOstandard4427uvresis
tant

Book of standards - 126


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

ThefittingsandtheaccessoriesfortheHdpepipesshallbeofthesamematerialandtheconnectionshallbe
mechanicalorfusionsystemdependingonthesizesordiameterofthepipeaspertherecommendationsby
themanufacturer

APPURTENANCES

Theexternalwatersupplysystemshallhaveabulkwatermeterforthemunicipalityreadingslocatedaroun
dthefrontageandprotectedandadditionallyalocalizedperblockwatermeterforeachblockisprosedat
eachreservoirinlets

Isolatingbronzevalvesenclosedinavalveboxesmadeofbrickwallandplatecoveredisrequiredwit
hinthecompoundwaterpipelayoutespeciallyforgardeningpurpose.

STORAGESANDPUMPS

Thewaterreservoirisnecessarymainlytomakereadilyavailablefordomesticreserveandthefirefightingi
ncaseoffirebreakandalsotosomeextentforusage.

ForallbuildingsGRPwatertankisselectedbasedonthecurrentengineeringpracticesconsideringfl
exibilityinuse,unitweight,andcost.etc

Thechosenpositionforwaterstationissecondbasementfloorasshownonthedrawing-
thispositionisselectedbecauseof,itsaccessibilityandsecurityreasons,andaboveallspaceavailability.

Book of standards - 127


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Foreachblockaseparatereservoirisplacedforflexibilityandmanagementpurposeandfinallyallthetanksw
illbeinterconnectedatlowerlevelandactasaunit.
ThereservoirisselectedtobemadeupofgloballyacceptedGRP(GlassReinforcedPlastic)reservoirswithmu
ltipleof50m3capacityarerecommendeddependingontherequirementattheplanningperiodasshownthe
GRPreservoirsarehygienically,hydraulically,acceptedandeasilycleaned,assembled&dismantled,lightw
eight,longlifematerials.
Theelevatedroofwatertowersarealsoselectedtobethemadeupofmaterialas
ofthereservoirs(GRP)andlocatedoneachblockmosttoprooffortherequiredheight.Seebelow

Thepumpstationislocatedadjacenttothereservoirandalsomadetobeinunderorovergroundforreduction
ofdisturbancesbypumpnoiseandforlessobstruction.

Eachblockwillhaveitsownprimarypumpandforstandbyshareswithothers.Thepumpstationshallhavetwoi
denticalcentrifugalself-
primingelectricanddieseldrivenmotorsforfunctionalandstandbypumpsrespectively.

Thesizingofthepumpsaredeterminedbyusingtheroofwatertankrefillingtimeandfrequencyofstartupan
doffposition

Book of standards - 128


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

4.2 .WASTEWATERDRAINAGE

4.2.1.INTERNAL

PIPES,FITTINGS,&ACESSORIES

Alldomesticwaste,ventandstormwaterpipelinesshallbecomplytoBS459,BS
4660,BS5481asappropriate,usingdoubleringsealsandgasketscomplyingwithBS2394uPVC,PN-
6pipesandshallbeprovidedwithaminimumslopeasstatedinthedrawing.Pipesandnecessaryfittingssha
llbestandardqualityandbefreefromdamageduringstorage,constructionandetc.Unitpriceshallinclude
allthe
necessaryassistancecivilworks,suchasexcavationcartaway,fixingorhangingtowalls,beamsorslabs.etc.
,necessaryfittingssuchasbends,Y,etc.StormwateruPVC,PN-
6pipesshallresisttheexternaltemperatureandthequalityshallmeetthepurpose.

Basedonthefixturetype,size,flowandtypeofthewastewatergeneratedthefollowingbasicpipesizes
andtrapsareusedforasinglefixture.

Thefixtureunit(FU)ratingisalsodepictedforbranchandhousedrainsandsewersselectedfromEBC
S-9page86…

Todeterminethesizesofbranchesandhousedraintheloadoneachsectionisconsideredintermsoffixtur
eunits.

ThesummationoftheloadintermsoffixtureunitsisusedtoselectthepipesizesfromatableEBCS-9page98-
101withminimumgradeforeachpipesection

Forventilatinginternaldrainageaseparateventingsystemispropsedwhereateachfloorlevelthewastesta
ckisconnectedinsuchawaytobeventedandfinallytheventheadisporturudedtoexternalairabovetheroof
level.

4.2.2.EXTERNAL
ThewastewatergeneratedinallbuildingsisassumedtobecollectedbyusinguPVCwastewaterpipe
andledtothenearbyAAWSSAsewerageline,whichisaroundthebuildingortothecompoundleveltr
eatmentfacility.
AlternativelyifforsomereasonstheconnectiontotheAAWSSAseweragelineisfailedordelayedthewas
tewatercollectedfromthewholebuildingisledtotheseptictankbyupvcpipefortreatment.Afiltermedia,s
oakawaypitfollowstheseptictank,wherebyeffluentisconsideredtobetreatedtosomeextenttobeconne
ctedtothenearbymunicipalwastewaterline.

ForinspectionandAllmanholesalongthesewerlinesshallbeofbrickwallandreinforcedconcretecompletewi
thcast-ironframe,cover,andladderandplacedat

Book of standards - 129


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

 SewerPipediameterchanges
 Changesinsewerslope
 Junctionswherethereisdirectionofflowchanges
 Whereinspectionisneeded
 Andatintervalsasshownbelowforinterceptingtheflow
Manholesspacingisbasedonsewersizeandthetypeofareasservedandtheintendeddistancebetwe
enthemanholesisvariable.Typicalcrosssectionanddetailisshown

4.3 STORM WATER DRAINAGE


Allroofswillbedrainedinternallythroughverticalandhorizontalpipework(UPVC)tomanholeslocatedext
ernaltothebuildings.Therainwaterwillthenbeconveyedtoconvenientdisposalpointsoutofthesitetogethe
rwiththesitesurfacewater.

Therun-
offfromtheroofiscollectedandledtothestormwaterdrainsbyusingupvcdownpipespaintedbyanti-
solarprotectivelayerandsecuredtowalls,slabsbymetalstraps.
Thesizesofthedownpipesareselectedfromachart(area,slope,rainfallintensity&no.&sizeofdrains)bylo
calizingtheroofdrainedareaandconsideringroofarea,roofslopeandtherainfallintensityofImm/hr

Theexternalstormwaterrun-
offthatisthedischargefromtheroofdownpipes,pavements,walkwayandroadsarecollectedbyopena
ndcloseddrains

Thecloseddrainsareinterconnectedbyacircularmanholeslocatedbetweenthedrains

4.4 SUBSURFACEDRAINAGE
Forthebuildingasubsurfacedrainageisprovidedwherebasementisconstructed.Thesubsurfacedrainageis
tointerceptthesubsurfaceflowthatmayaffectthebasementsandsurfaceinfiltrationsbyusingaporousfilter
mediamadeofwashedgravelinawovenpolyethylenesheetgeosyntheticmaterial

Theflowsarecollectedinthemanholesthentosumppitsandfinallydischargedtothenearbystormwaterd
rainagesystembysubmersibleautomaticpumps.

Book of standards - 130


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

5.FIREFIGHTINGSYSTEM
Book of standards - 131
.
Ethio-Telecom Head Quarter, IT park Addis Ababa

5.0 FIRE FIGHTING SYSTEM

for the building a water-based fire fighting system is designed as per the
requirements set in EBCS-9 and portable multipurpose fire extinguishers placed
adjacent to the FHR
Fire hose reels are used for fire fighting in case of firebreak. For all floors of block
hydrant is designed for the floor the floor area which is less than 800 m2. for area
greater than 800m2 two FHR are used as per the code
Additionally a sprinkler system is used where there is assumed to be public interference
is high and fire expectation is high around public lobby

And also chemical based extinguishers shall be placed at fire vulnerable rooms like
data rooms, kitchen and security
Externally the fire suppression is done by using fire hose reel boxes and portable fire
extinguishers located at four sides of the site and additionally for refilling a fire
brigade track a pillar type fire hydrants are used and located at four corners as
shown.

Kitchen Fire suppressors Fire pump

Book of standards - 132


.
Ethio-Telecom Head Quarter, IT park Addis Ababa

Fire Hose reel & extinguisher Box

Sprinkler heads

Fire Hose reel & extinguisher Boxes

Book of standards - 133


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

6. MECHANICAL
Book of standards - 134
.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

6.1VENTILATIONANDAIRCONDITIONINGSYSTEM
AddisAbabaislocated2400mtabovesealevel,9°21’Nlatitudeand38°45’Elongitude.Max.summert
emperatureis28.5°cDB,19°cWBandmin.wintertemperatureis5°cWB.

Meetingroom,trainingrooms,topmanagerialofficesandboardroomfloorwillbeequippedwithfancoilsc
onnectedtothecoolingsystem.Forallfancoilscondensedwatercollectorpipesshallbelaidandpipesshallb
econnectedtoneareststormwaterdrainageline.
Assemblyhallwillbeequippedwithacoolingchillerandairhandlingunit.(notetobeincluded)Forgym/wor
kout,staffandexecutivedining,stores,technicalroomsandmainkitcheninsemi
basementandgroundfloorwillhavebothsupplyandexhaustairfacilities.(notetobeincluded)

Basementcarparkingwillhavemechanicalsupplyandexhaustairventilation.(notetobeincluded)
Eachblockofficecorridorswillhaveanexhaustairventilation.(noteprincipleofwork)

6.1.1Cooling

Thecoolingforthecoolingandairconditioningofoccupanciesintheofficebuildingblocksaswellasthecoo
lingofassemblyhallinstallationistobecarriedoutbyacoolingwithanaircooledchiller,moreeconomical
alternativesarepossible.Integratedhydronicmoduleaircooledchillersarepreferred.

Thenecessarycoolingcapacityistobecalculatedandaneconomicalcoolingsystemistobeconstructed.The
pumpsofthechilleraretobecarriedoutasdoublepumpsandattentionistobepaidtothefrostresistanceofth
efacilities.

- Coolingmachinery aircooled
- Typeofdrive electric
- Coolingagents R410A
- Refrigerationcapacity Accordingtocoolingloadcalculation
- Systemtemperature 6°/12°C
- Dimensioningfortemperatureupto40°C

Figure:chillerwithintegratedhydraulicmodule

Preferredmake:manufacturer:YorkorCarrier

Book of standards - 135


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

6.1.2Pipematerials,insulation:

AllthepipelinenetworksandfittingsareusuallytobedesignedandverifiedatratedpressureofPN10b
ar.Theappropriateacceptancerecordsincludingproofofflushingshouldbepresented.

Colddistribution/chillingpipeworkDuracoolpre-insulatedABSpipes.

Insulationwithdiffusionproofrubberinsulation,basedonthequalitystandardofthecompany,Armstrongpr
oductArmaflex19mminsulationthickness,gluedontheentiresurfaceofthe
pipewalls.Outsidechillingpipeworkshallbewithprotectivejacketmadeofmetal.

AllpipelinenetworkshaveacoatofpaintorinsulationandaretobemarkedinEnglishwithpermanentla
bels.

6.1.3 TableshowingVentilationandAirconditioningsystemforoccupancies

Item Occupancy Supplyair Exhaustair FanCoils Cooling Electric


no. Heating
1 Toilets Natural Mechanical No No No
(Fan)
2 Offices Natural Through No No No
corridor
3 Officecorridors Natural Mechanical No No No
(Fan)
4 Meeting,trainingrooms Mechanical Mechanical Yes Yes Yes
(Fan) (Fan)
5 TopManagerialoffices Mechanical Mechanical Yes Yes Yes
andBoardroomfloor (Fan) (Fan)
6 Gym/workout Mechanical Mechanical Yes Yes Yes
(Fan) (Fan)
7 Staffandexecutive Mechanical Mechanical No No No
dinning (Fan) (Fan)
8 Kitchen Mechanical Mechanical No No No
9 Technicalrooms Mechanical Mechanical No No No
(Fan) (Fan)

Book of standards - 136


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

10 Stores Mechanical Mechanical No No No


(Fan) (Fan)
11 Assemblyhall Mechanical Mechanical No Yes No
(AHU) (Fan)
11 Basementcarparking’s Mechanical Mechanical No No No
(Fan) (Fan)
12 Staircase Mechanical No No No No
(Fan)

Description Temperature Temperature


Winter(°C) Summer(°C)
Ambientdesigntemperature 5DB 28.5DB
ManagerialofficesandBoardroom 20 25
Assemblyhall,Meetingand 20 25
Trainingrooms

HumidityDescription
Ambientdesignhumidityshallbe90(winter)/40(summer)
Aspecifichumidificationanddehumidificationoftheairisnotplanned.Recom
mendedminimumfreshairsupplyratesforroomis10liter/sec.
Roomnoiselevel

6.1.4 Theroomnoiselevelshouldbeagreedwiththeclient
Occupancy NoiseLeveldb(A)
Offices 30
ManagerialofficesandBoardroom 30
Meetingrooms/Auditorium 30
Gymnasium 60
Kitchen 40

6.3GeneralRequirementsofVentilationandAir-
ConditioningUnitsandOtherEquipments.

6.3.1 Cooling coils


Heatingandcoolingcoilsshallbedesignedaccordingtofollowingrequirements.Ceilingcoolingunitswill
beinstalledinmeetingrooms,trainingroom,topmanagerialofficesandboardroomfloorandgym/wor
koutareas.Thoseunitsoperateinrecirculationairmodeandtheyshouldmaintaininsummerthetemperat
ureinsideofvalue≤8°Cinrelationtoexternaltemperature,butmax.30°C.

Controlsystemofventilationandcoolingshallrenderthefollowingfeatures.

-Temperaturecontrol
-Airmixingcontrol
-Supervisionoverfreezing
-Dailyandweeklyprogram

Book of standards - 137


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

• Maximumpressuredropheating-andcoolingcoilsshallbe30kPaonwaterside.
• Maximumairvelocityforcoolingcoilsinshallbe2.0m/s.

6.3.2Airfilter

Airfilters,factorymade,designedasfollowsandaccordingtoEthiopiannormsAHU´sshallbeprovidedwit
hcleanablefiltersequippedwithpressuredifferencedetector.

AHU’sshallbeprovidedoneextrasetoffilter.Ifpossiblesparefiltershallbepossibletobuylocally.

6.3.3Dampers

Necessary numbers of dampers for adjustment shall be installed.

Adjustment dampers in duct-work shall be type iris damper, to be designed for cleaning inside
ducts by opening the damper.

Requested Fire dampers shall be provided according to Ethiopian standard EBCS-11 and also
fulfill the following.

The fire dampers shall be connected to a supervision and control system connected to the Fire
Alarm center.

If any of the dampers are not functional as planned, the malfunction shall be indicated.

In case of power brake and in case of stopped fans, dampers for smoke and dampers for both
smoke and fire shall close.

6.3.4Fans

Thefansshallbecompletelyequippedtoachieveintendedfunctions.

Theexhaustfanforthekitchenexhaustshallbebeltdrivencentrifugalfanswithbackwardstraightimpellers
,inspectioncoveronthecasingandadrainbossinthebottomofthecasing.

Thecapacityofthefansandmotorsshallinclude15%asareserve.Rooflocat
edfansshallbeassembledonfactorymaderoofcurbs.
TheoutdoorfansshallbecoatedtobeprotectedfortheclimateofAddisAbaba.

6.3.5Silencer
Providefactorymadesilencerswhichshallfacilitateeasyinsidecleaning.Silencersshallbeinstalledt
ofulfillthenoiselevelrequirement.

Book of standards - 138


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

6.3.6Ducts
Ventilationchannelsaswellasrequiredpipefittingsandroundpipeswithrelevantpipefittingsshouldbem
adeofgalvanizedsteeltinwithproperhangingsandstiffening.Inventilationchannels/pipessuitableinspe
ctionopeningsprovidedforchannelcleaningworksshouldbeinstalled.

Ductsandductworkelementsshallbegalvanized,factorymade,designedasfollowsandaccording
toEthiopianstandards.

Kitchenandsmokeexhaustductsshallbemadebyweldedblacksteelsheetof1.5mmthicknessinordertobeli
quidproof.

Provideaccessdoorsforcleaningeverypartofthesystem.Horizontalductsshallbeexecutedwithslopetof
acilitatedischargeofcleaningliquid.Lowestedgeprovidedwithdischargevalve.
Exhaustductsfromdishwashingmachinesbycircularwoundfactorymadealuminum.
• Maximumpressuredropshallbe0,8Pa/m
• Minimumdiametershallbe130mm.
• Ductsshallbeprovidedwithinspectionpanels(hatches)facilitateinsidecleaningandinspect
ion.
• Openductendsshallbeprotectedfromdirtwithprovisionalarrangements.
• Beforethe“TestsonCompletion”allductsshallbecleanedinsideandoutside.

Supplyandexhaustairdevicesmaybeconnectedtotheductswithamaximumof1mlongflexiblemetal
tubeiftheconnectionpointislocatedaboveaclosedsuspendedceiling.

6.3.7Accessdoors

Tofacilitateforinspection,cleaningandmaintenanceaccessdoorsshallbeerectedinspecialsectionsahe
adofallcoolingandheatingcoils(bothsides)etc.

6.3.8Ductworkinstallation

Coolairductsshallbeinsulatedwithmineralwool,byblanketminimumthickness25mmandcoveredwithA
luminumfoilinclosedsuspendedceilings.Visiblecoolairductsshallnotbeinsulated.

Acousticinsulationshallbemadeinternallybymineralwoolandcoveredwithperforatedgalvanized
sheetmetal.

Fireinsulationshallbemadebymineralwool.Visibleinsulationshallbecoveredwithmetalfolioandwire
mesh.Elsewherewiremesh.

6.3.9Supplyandexhaustairdevices

Book of standards - 139


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

Alldevicesshallbefactorymadeofstandardtypemodelswithadjustableairflowratesanddirections;It
shallbepossibletomeasuretheairflowfromalldevices.Airflowsfromsupplyandexhaustdevicesshallb
eshownonthedrawingsforeachoccupancy.
Devicesshallbeeasytocleanandmadebyfactorypaintedsteelsheet,oranodizedaluminum.

6.3.10Cowlsonrooflocated

Cowlsshallbefactorymadebygalvanizedsteelsheetassembledonfactorymaderoofcurb.

6.3.11Out-doorairintakegrilles

Grillesshallbefactorymadebygalvanizedsteelsheet.

6.3.12Analogousthermometers

Provideanalogousthermometersinallventilationandairconditioningsystemstoseetheirtemperature
schange.

6.5CoolingSystem

6.5.1Functionoverview
ThecoolingofchilledwatersupplyingbuildingpremisesandFan-
coilunitsshallbeaccomplishedbymeansofnecessarynumbersfactoryassembledandfactoryfullloadr
untested“Microprocessorcontrolled,air-
cooledliquidchillersutilizingscrollcompressorsandhydraulicpumpsystems’’.

CoolingwatersystemsshallbeconnectedtoallfancoilunitsandtoallAirHandlingUnits.Thecoolingsystems
shallbeconnectedandmonitoredbytheBMS.

Thecoolingplantshallbeinstalledaccordingtowhereshowninthedrawingandbeofhydraulicmo
dulewithdualpump.

Unitshallalsobeprovidedwith:

Factoryinstalledmicroprocessor-controlled,minimum-
loadcontrolthatshallpermitunitoperationdowntoaminimumof15%capacity.
• Coolerheatersprovideprotectionfromcoolerfreeze.
• Safetyarrangements,mudstrainersandautomaticallyoperatingairmicrobubblesep
arators.
• Buffertanks
• Hydronicmodulechilledwaterpumpswithstand-bypumpsandwithauto-changeover.
• Factorymadeelectricswitch-boardsandcontrolboards

Book of standards - 140


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

Thecoolingofairconditioningshallbeaccomplishedbymeansofonefactorymadewaterchilledunitus
ingenvironmentallyapprovedcoolingagent,FreonR410Aorequal.

Theair-
coolingcondensersshallbedimensionedformaximumoutdoortemperaturesof+40°C.Theevaporatorssh
allbedimensionedforcoolingwatertemperatures6/12°C

6.5.3CoolingWaterDistributionNetwork

ThechilledwatersystemsshallbedesignedastwopipesystemssuppliesAirHandlingUnitsandfancoils.Thes
ystemshallbedesignedandconstructedforthecalculatedcapacitiesofthebuilding.
Pipenetworkshallbedesignedmaximumpressuredrop,100Pa/m.

Material:ABS-Duracool
Thecoolingdistributionnetworkshallbeequippedwithsufficientnumberofclosingandadjustingval
vesinordertoadjustittocorrectwaterflows.

AHU’sandallfancoilsshallbeequippedwithclosingvalves.
Coldwaterpipesinsulationshouldbeapprovedqualityofrubberinsulationmaterial(Armaflexorsim
ilar).Jointsoftheinsulationshallbegluedandtight.Thefancoilsshallbedesignedforlowtemperaturei
ncludingheater.

6.5.4Consumables&SpareParts

Thefollowingminimumsparepartswillbeprovided;
PriortohandingoverthenContractorshallprovideconsumablesasfollow:
1.VentilationsystemfiltersminimumoneseteachAHU.
2.Fanbelts2pcseachfan.

6.5.5MarkingandLabeling

Pipesandductsplastictape360ºvisibilitiesshowingthemediainplaintextaswelldifferentcolourandfl
owdirection.Distanceshallbefrequent.
Allpartslikepumps;AHU,valves,controllersetc.shallbelabeledwithindividualidentificationno.engrave
donwhiteplasticsheets.

6.5.6ContractorsTestingandAdjustmentsbeforeCompletion

TheContractorshallsubmitadetailedtestprogrammefortheEmployersapprovalbeforestartingthe
tests.

Thefollowinggeneraltestsshallbeprovided,

• Performancetests(totalcapacityetc.)ofeachsystem
• Adjustmentsofallflowratesinliquidandairsystems

Book of standards - 141


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

• Soundleveltestsinoccupiedzones
• Water,coolingsystem,
• Tightness(pressure)testsofallpipes
• Performancetestsofcoolingplants(systems).

TheContractorshallpromptlyforwardtotheEmployerdulycertifiedreportofthetests.

Ventilationandairconditioningsystems,

1.Performancetestsofmaximumtransmittedheatingandcoolingpowerforeachheatingandcoolingc
oils.
2.Performancetestsofairflowratesineachsystem

TheBMS-system

1.Allsystemsandfunctionsshallbetestedfromthecomputer.

2.Oneweekfaultfreecompletelogallsystemswillbeprovide

Book of standards - 142


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

7.ELECTRICAL

Book of standards - 143


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

7.2.1 OFFICE BLOCK LIGHT


RECESSED CEILING DOWNLIGHTS
Manufacturer: PHILIPS
Product family code BBS560 [BBS560]

Ceiling type Exposed- and Options Emergency lighting Concealed ceilings: bracket
symmetrical concealed (integrated): 3hours (EL3)* ZBS460SMB (1 set = 4 pcs)
T-bar ceiling and plaster Lighting controls: reach is 25 - 65mmConcealed
(board) ceiling Actilumemulticontroller(ACL)* ceiling with T-bar 38 mm:
Ceiling grid Module size in Compatible with DALI (only bracket ZBS460 SMB-TPM (1
length: 600 x 600 mm, relatingto dimmable driver set = 4pcs)
Module size in length: 625 x PSD)Euro fuse (FU) included Brackets for plaster ceilings
625 *not for BBS561 ZBS460
Module length: 675 x 675 mm Materials Housing: zinc- SMB-PLC (1 set = 12/24
Light source Philips DayZone coated steel pcs)*Through-wiring possible
LED module Rim: post lacquered *Suspension brackets are
4000 K: 51 W (LED35S) Optical cover: acrylic (AC- included for
3000 K: 55 W (LED35S) MLO),polycarbonate (PC- BBS561
Beam angle 90º MLO) Connection Push-in connector
Lum.flux 3500 lm Color White (WH), silver grey (PI) or with pull
(independent of CCT) Exposed ceilings: in lay, no relief (PIP)
Driver Built-in bracketsneeded Wieland connector GST 18, 3
or 4poles (W, W4)

Book of standards - 144


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

OFFICE CEILING LIGHTS


Manufacturer: ASD Lighting
Name of Product: Rhapsody LED
Supplied with TRIDONIC LED (4000˚K) with a CRI of
85
2.4m x 3m typical spacing’s (600 x 600 mm
version).
Meets the average luminance limits of 3000 cd/m²
at 65° (LG3).
Materials: steel, finished in white (RAL9016) and
available with premium opal refractor.
Installation: Suitable for draw-up and lay-in
applications making it suitable for a number of
ceiling systems such as exposed ‘T’, concealed fix
and some metal pan ceilings.
Plug & Play options
Standards
IP20CE‘F’ MarkBSEN.60598.2.1Class 1
Options
3000˚K available on request.
Integral emergency.
Stand alone proximity sensor.
DSI / DALI Dim / Analogue.
3% to 97% pre-programmed e-Motion Corridor
dimming
Plug & Play options on request
Sizes (mm)
600 x 600 – Recessed, 600 x 600 – Surface,500 x 500 – Recessed,1200 x 300 – Recessed,1200 x 600 –
Recessed
LED & Operating options:
3000 – Standard Output,4500 – Medium Output,6000 – High Output 600 mm,9000 – High Output 1200 mm

OFFICE WALL MOUNTED LIGHTS

Manufacturer Formagenda
Name of Product: Tape

TAPE is a lighting-range that uses the latest high end LED-technology. The
innovative setup allows a very thin design. The LED is providing a warm
comfortable atmosphere. Like a slip of paper TAPE seems to float in front of
the wall or above the table. With its minimal and light but still powerful
design TAPE is a highlight in every room.
Material: aluminiumanodized
Colours: black, white, silver, champagne, aluminum polished

This product contains built-in LED lamps belonging to energy classes:


A++Energy classes on a scale of A++ (highest efficiency) to E (lowest
efficiency).

Book of standards - 145


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

7.2.2 LOBBY AND GALLERY LIGHTS

Designer Hans Buschfeld developed the low-voltage system LightLight® system, OLEDs are suspended in the
space on fine wires of differing lengths.
Using LightLight® modular components, the track can be combined to meet project-specific requirements.
Hundreds of BLACKBODY OLED elements (1.6W / OLED) vary in colour temperature between 2700 K and
3000 K.I.Rain is a customized luminous object. Sending inquiries with square measurements and design to
designers is possible.

Book of standards - 146


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

GALLERY LIGHTS
Manufacturer Ingo Maurer

Name of product: Flying Flames


Flying Flames is a flexible chandelier system. Elements are placed freely with a magnet on the canopy
board. The canopy board with integrated electronic ballast comes in two sizes. Flying Flames is designed to
permit individual ver- sions of a chandelier. Choose between the rectangular for the smaller, square
canopy, or place multiple canopy boards in a line to create a long chandelier.
Material
Circuit board,metal, anodisedaluminium, plastic
Light source
Flame Element: two displays with each 128 dimmable LEDs, 0.6 W, 2700 K, CRI > 80 Ra
Downlight Element: 7 W, 2700 K, 530lm, CRI > 90 Ra
Technical data: 125-230 V, secondary output 38 V and 5 V. Maximum 25 W
Dimensions
Cable length: 200 cm. Canopy 60 x 60 cm or 114 x 40 cm. Flame Element 43 x 3 x ca. 0.3 cm. Downlight
Element 14,5 x 2,5 x 2.5 cm
More info
Both types of the canopy made of white lacquered steel are equipped with jacks for up to ten Flame
Elements and a maximum of two Downlight Elements. The downlights are equipped with a touch dimmer
with memory function. The flame elements are dimmable separately by holding down a small button on the
circuit board. Integrated electronic ballast adapter.
This product contains built-in LED lamps belonging to energy classes: A+

Book of standards - 147


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

GALLERY LIGHTS
Manufacturer: Barrisol
Name of product:
Contemporary Light Column
Barrisol Lumière Color stretch
ceiling allows a multitude of
moods and ambiences to be
created thanks to the light
variation and color changes. The
rhythm, animations, and emphasis
of the space is dependent on
which specific lighting system is
installed above the Barrisol
translucent stretch ceiling.

Barrisol Lumière Color uses a Barrisol translucent sheet enlightened by a higher source of light. It then
becomes possible to play with the light intensity and different colors thanks to a system of light variation
(LED lighting).

Book of standards - 148


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

7.2.3 CONFERENCE AND MEETING ROOM LIGHTS


Profile in extruded
aluminiumpaintedwhite.Suitable for wall / ceiling
or suspended compositions. Complete with
lampholder, ballast. Through wiring 3 or 5 poles
x dimm/em. To be ordered separately:
polycarbonate diffuser and T5 seamless bulb.

XP2040-60
59cm x 70cm, h 9,4cm
24W/830 HO24SLS G5

XP2040-90
89cm x 70cm, h 9,4cm
39W/830 HO39SLS G5

XP2040-120
119cm x 70cm, h 9,4cm
54W/830 HO54SLS G5

Manufacturer:KOBE
Name of Product: KAGAWA Line
Description: Decorative pendant light luminare
for LED with its own reflector.
Technical Details: luminare made out of top
quality aluminum material, painted ecru and
black electronic or HF ballast, luminare
featuring wire suspension and transparent
supply wire.
Application: conference halls , galleries, offices

Book of standards - 149


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

7.2.4 AUDITORIUM LIGHTS

Book of standards - 150


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

Book of standards - 151


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

7.2.5 BASEMENT LIGHTS


Manufacturer:PHILIPS
Product family code: WT460C
[WT460C]
No. of light sources:4 [4 pcs]
Lamp family code LED42S [LED Module,
system flux
4200 lm]
Light source color 840 [840 white]
Optic type WB [Wide beam]
Ingress protectioncode IP66 [Dust
penetration-protected, jet-proof]
Length L1300 [1300 mm]
Glow-wire test 850/5 [Temp. 850 °C,
duration s]
Input voltage 220-240 V [220 to 240 V]
Housing material PC [Polycarbonate]

7.2.5 OUTDOOR LIGHTS


DRIVE OVER GROUND LIGHT
Drive/ Walk over recessed up light with round ring, for wall/pavement mounting requiring recessed
box
Indoor and outdoor light fitting
Drive/walk-over recessed uplight with round ring, for pavement mounting with recessed box
Colour:Stainless steel
Suitable for Pedestrian areas, gardens, sheltered inside
Technical details-fitting
• Reinforced thermoplastic recessed box
• Anodized die-cast aluminium body
• Flat, clear tempered glass diffuser 12mm thickness
• Adjustable ±15° for all lamp types
• AISI 316L stainless steel ring
• Drive-over 2500Kg at max. 20Km/h
• Stainless steel screws
Technical details RGB
• Led RGB full color 3x3W EDISON with beam optics 30°
supplied in 12V PWM
• Cable 4x0.5mmq H05RN-F (1mt)
Compulsory accessory
• Recessed box ø190x270mm (Cod. 7000.0002)
Compulsory accessories RGB
• DMX generator (Cod. CS180011)
• DMX controller with driver (Cod. CS180008)
• RGB connection kit 4 pole (Cod. CS180018)

Book of standards - 152


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

Accessory
• IP68 connector (Cod. CS093002)
OUTDOOR LIGHT FITTING( Bollard Type)
Decorative “total light” fitting with recessed body in 2 heights: 98mm and 501mm
Requiring recessed box
Color
White translucent
Suitable forPedestrian areas, paths, private gardens
Special features
Total lighting optics
Maximum safety through separation of wiring and optics
Technical details-fitting
• Anodized die-cast aluminium body
• Flat trasparent tempered glass diffuser 12mm thickness
• Cylindrical optics in white translucent polycarbonate
• Closing cap in reinforced thermoplastic
• Thermoplastic conical reflector
• Stainless steel screws
Technical details RGB
• Led RGB full color 3x3 EDISON supplied in 12V PWM
• Cable 4x0,5mmq H05RN-F (1mt)
Compulsory accessories
• Recessed box Ø190x270mm (Cod. 7000.0002)
Compulsory accessories RGB
• DMX generator (Cod. CS180011)
• DMX controller with driver (Cod. CS180008)
• RGB connection kit 4 pole (Cod. CS180018)
Accessory
• IP68 connector (Cod. CS093002)
FACADE FLOODLIGHT
Manufacturer: Toshiba
Product name :outdoor projector / ip65 / led floodlight 5500
FEATURES
Dimmable: No
Electrical class: II
Protection rating: IP65
Power factor: 0.9
Temperature range: -20 °C - +35 °C
Constant lumen output
ENEC

Book of standards - 153


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

OUTDOOR LIGHTING FITTINGS


Stud Led
Code : 1876282M

LED fitting for pole top use on Ø60mm poles

Suitable for
Main and secondary roads, cycle paths, pedestrian areas, parking areas, public and private gardens,
squares

Accessories/Compositions
Stud System

Special features
Pull-out wiring compartment closing door for easy maintenance
Conforms to local and international dark sky laws
Possibility of direct current supply in 12V to integrate the photovoltaic installation
High lighting efficiency
Energy saving

Technical details fitting


• Die-cast aluminium body
• Thermoplastic wiring compartment closing door
• Acrylic transparent diffuser
• Thermoplastic cover
• Cut-out system when opening the wiring compartment door, through disconnecting switch
• Stainless steel screws

Technical details monochromatic Led


• 24 monochromatic Led 55W CREE 4000K neutral white (NW), 5976 lm, supply tension 220-240V 50-
60Hz

LED optics for a round symmetrical, predominantly frontal light


throw, guaranteeing a good level
of performance at elevated distances

Book of standards - 154


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

OUTDOOR LIGHTING FITTINGS


Materials and Finishes: Column and arm
made of a continuous galvanized steel
tube section with a grey paint finish,
measuring 120 x 280 mm and 2.5 mm
thick (4.7 m street lamp), and 150 x 300
mm and 4 mm thick (7.7 m street lamp).
LED Luminaire: Optical unit based on
closed LED technology modules using
light distribution refractor lenses. Set of
36 LEDs (max. 55 W) for 4.7 m lamp
and 72 LEDs (max. 110 W) for 7.7 m
lamp. Neutral white light tone (4500 K).
It can also be provided in warm white
light tone (3000 K).
Adjustable electronic power supply. The LED modules can be powered from 350 mA to 500mA. 40W
36 LED (350 mA), 55W 36 LED (500mA), 80W 72 LED (350 mA) 110W 72 LED (500mA)
Installation and maintenance:The street lamp is delivered in two parts: the structure and the optical
unit.
The column is embedded using a concrete cube made on-site and four anchor bolts, 20 cm below the
pavement surface. A groove must be made for wiring. The template and anchor bolts are supplied
with the column.
Standard replacements and maintenance for fittings.LED technology minimizes functional maintenance
of the luminaire
Weight: 4.7 m: 117.5 Kg, 7.7 m: 265.5 Kg.
WALL MOUNTED FLOODLIGHT
Manufacturer: RAB lighting
Name of product: STL1HBLED2X13W
Lifespan: 100,000-hour LED lifespan based on IES LM-80
results and TM-21 calculations
Swivels: Fully adjustable with sure-grip locks. 1/2" NPS
threaded arm with serrated locking swivel fits all standard
mounting covers. Color matched EZ Grip lock nuts. Stainless
steel screw.
Housing: Precision die cast aluminum housing
Reflectors: NEMA 5x5 floodlight reflector with 4x4 optional
spotlight reflector for field installation. Photometrics show
flood configuration.

Fixture Efficacy: 47 Lumens per Watt


Drivers(2):Multi-chip 13W high output long life LED Driver Constant Current, 100V - 277V, 50/60 Hz
Sensor Time Adjustment:5 seconds to 12 minutes.
Sensor Surge Protection :Withstands up to 6000 volts.
Sensor Wide Sensitivity Control :Adjustable from 100% to 30%.
Sensor Temperature Compensation :Sensitivity adjusts automatically for consistent detection in hot and
cold ambient temperatures.
Sensor Wall Switch Manual Override:Two flip logic prevents activation by momentary power outages.
Override resets to auto at dawn. No extra wiring needed.

Book of standards - 155


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

Sensor LED Detection Indicator :Shows when sensor is detecting in daytime and glows red at night for
"on-guard" deterrence.
Sensor Advanced Detection Logic :Minimizes false triggers.

7.2.7 MISCELLANEOUS LIGHTS


Manufacturer: LUMATEC FRANCE, LUMATEC SUISSE
The same lamp can be installed as a recessed, semi-
recessed or surface fitting. The lamp features a prismatic
cover and is suitable both for ceiling and wall mounting.
Electronics prevents appliances from over-heating. Low
working temperature maximizes battery life.
MaterialMetal housing, powder coated RAL 9006. Any
other RAL and NCS colors on request.Also available with
LEDCE label and in conformity with EN standards.
Lamp with individual battery:
Mains voltage: 230V/50-60Hz ±10%
Battery: Maintenance-free Ni/Cd , 1h or 3h
LED-type lamp: Ni MH
Recharge time: 90% of capacity in 20 hours
Luminous flux : about 60% of mains
Power requirement: 2 VA maximum
Emergency operation: at 70% of mains voltage
Lamp for use with central battery systems:
Connection: 220, 110, 60,40, 24V AC/DC (+ 30% -20%)

RECESSED LUMINAIRES FOR WALLS AND STAIRS


Manufacturer: BEGA
Product name: 2201
shielded light
with LED or for fluorescent lamps
Protection class IP 64
Cast aluminium, aluminium and
stainless steel,Safety glass, matt
2196 · 2197 Reflector made of
pure anodisedaluminium
luminaires for operating with
alternatingand direct current
LED colour temperature optionally
3000 K or 4000 K
3000 K Article number
4000 K Article number + K4
Luminaire colour optionally
graphite or silver

Book of standards - 156


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

RECESSED SPOTLIGHTS FOR DIFFERENT SPACES

Type BBS480 (UGR22 version)


BBS481 (UGR19 version)
Light source Non-replaceable LED module Color White (WH), grey (GR) or black (BK)
Light color Warm white, 3000 K InstallationRecessed,fixation by means of spring
Neutral white, 4000 K fasteners
Power 13 W (3000 K), 12 W (4000 K) Accessories Adaptor ring 175 mm to 150 mm
Luminous flux BBS480: 1095 lm cutoutdiameter
BBS481: 1076 lm Material Heat sink, bracket, reflector and front
C RI85 rim: aluminum
Median useful life Fixation: steel and polycarbonate
L80B5050,000 hours Driver box: plastic
Median useful life Color White (WH) or grey (GR)
L90B5025,000 hours Installation Fixation by means of spring fasteners
Driver failure rate 1% per 5000 hours Main applications Retail, shops, airports, hospitals,
Average ambienttemp.+25 ºC
Power supply 220-240 V / 50-60 Hz
Integrated into independent driver
box
Optic High-gloss mirror, UGR22 (BBS480)
High-gloss mirror with ring louver,
UGR19 (BBS481)
Matt reflector, UGR22 (BBS480)
Connection Wieland (W)
Push-in (PI)
Option Lighting controls: dimming by DALI
Emergency lighting: 3 hours (EL3)

Book of standards - 157


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

RECESSED WALL LIGHT


Manufacturer: daisalux
Name of product:

Description:
Small recessed unit comprising a square Zamak
embellisher and a square/round diffuser of
tempered glass. Mains voltage power supply 230V
AC or 24V AC/DC.Lights up by LEDs. Has
accessories to also operate when mains power is
off (PBL units) or with a low safety voltage (TL
transformer).
Characteristics
Format: Lecu round or square
Operation: Luminaire, Self-contained
Voltage: 230 V 50Hz / 24V AC/DC
Autonomy (h): It depends on the PBL power suppy
unit PBL*. 1h Self-contained
Emergency lamp: White Led for Self-contained
Mains lamp: White Led
Degree of protection: IP 65 IK06, IP 66 IK06 (Inside
recessing box, adequate for outdoor)
Electrical insulation: Type II and Type III
Colours: cool white, Warm white, Blue

BATHROOM LIGHTS

Manufacturer: Pujolilluminacion
Family: ARCOS
Application: Bathroom Lights
Description: Wall lamp with LED strip
Versions: USA UK J
Diffuser: Polycarbonate
Frame: Aluminium
Finishes: Chrome - Matt nickel - White - Antracita Mate
Bulb:
LED 40W 3300lm 3000K (4000K optional)

Book of standards - 158


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

LED LIGHT SCREEN

GALLERY LIGHTS

Book of standards - 159


.
ETHIO TELECOM HEAD QUARTER BUILDING Book of Standard

Manufacturer Sattler
Name of Product: CircoloTris

Sophisticated circular light with


ceiling canopy and three current
carrying steel cable suspensions
with flexible inclination angle
possibilities.LED technology 24 V,
light temperature 3000K,
optionally 4000 K. Dimming 1-
10V possible.Colour options:
white, polished aluminium.

This product contains built-in LED


lamps belonging to energy classes:
A++,A+,A

Energy classes on a scale of A++


(highest efficiency) to E (lowest
efficiency).

Contemporarily interpreted
chandelier UNIONE, consisting
out of 6 illuminated rings out of
aluminum, light output outwards,
with applied acrylic diffuser,
ceiling canopy for fixation and
steel cable suspension; 24V LED
technology; colour temperature
3000K, optionally 4000K and
dimming (1-10V or Dali). Frame
color white, polished aluminum.

This product contains built-in


LED lamps belonging to energy
classes: A++,A+,A

Energy classes on a scale of


A++ (highest efficiency) to E
(lowest

Book of standards - 160


.