Professional Documents
Culture Documents
INSTRUCTIONS
- Click on the name of the drawing below to be taken driectly to
the drawing.
- Printing
--Choose"Current Page" to print a single drawing
-- Choose "Fit" to ensure the drawing will print correctly
Cattle Sheep/Goats
Barbed-Exterior HT Electric-Exterior
Barbed-Interior HT Electric-Interior
HT Electric-Exterior Non-Electric-Exterior
HT Electric-Interior Non-Electric-Interior
Non-Electric-Exterior Woven-Exterior & Interior
Non-Electric-Interior HT Woven-Exterior & Interior
Woven-Exterior & Interior HT Electric Woven- Exterior & Interior
HT Woven-Exterior & Interior
Swine
Horse HT Electric-Exterior
HT Electric-Exterior HT Electric-Interior
HT Electric-Interior Woven-Exterior & Interior
HT Electric Poly-Coated Exterior
HT Electric Poly-Coated Interior
Woven-Exterior & Interior Temporary Fence
Temporary Electric Fence
Temporary Electric Netting
Bison
HT Electric-Exterior
HT Electric-Interior Other Fence Details
Brace
Brace-Electric Fences
Deer Energizer
Specialty Height HT Woven-Exterior & Interior
Poultry
Woven-Exterior & Interior
Specialty Height HT Woven-Exterior & Interior
STANDARD BARBED WIRE FENCE
CATILE. EXTERIOR
t
1��w
• �o�
Z
:::c N
I- uoo
"'"W::::,D..
c., .. .. .. .. .. .. .. .. w
zD::1-
e!>
w
...J
LL.
GROUND LINE
.,y.'x�
I
"-A/.,
:::c '0..
I I I 1 WIRE SPACING FROM GROUND
I I 1 15· TO 42·
I-
w
0
I I
LJ LJ
GROUNDING
IT IS RECOMMENDED THAT FENCES WITHOUT STEEL POSTS BE
BARBED WIRE SHALL NOT BE ELECTRIFIED OR INSULATED FOR GROUNDED FOR LIGHTNING PROTECTION AT LEAST EVERY
ELECTRIFICATION QUARTER MILE. ALL LINE WIRES MUST BE GROUNDED. USE
12.5 GAUGE WIRE FOR LEAD-OUT WIRE.
BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END
ASSEMBLIES. SEE BRACE DETAILS. -GROUND RODS
MIN 4 FEET INTO GROUND
H-BRACING IS REQUIRED AT ALL PULL ASSEMBLIES AND MUST BE 0.5" MIN DIAMETER, GALVANIZED STEEL
INSTALLED EVERY 660' MAX. SEE BRACE DETAILS
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = FT.
Date Drawing Name
United States STANDARD BARBED WIRE FENCE Designed 701-1A
Department of CATTLE, EXTERIOR
Drawn Date
Agriculture 7/19
CLIENT: Checked
Natural Resources Approved
Conservation Service COUNTY: Sheet of
HIGH TENSILE PERMANENT ELECTRIC FENCE
CATTLE, EXTERIOR
30' MAX---------•
50' MAX IF LAND SLOPE < 5% OR
1oo· MAX IF STAYS ARE PLACED EVERY 33'
1
�:�: �= �g: PO
����R PO�
STAY
_J
GROUND LINE
DIA = 7/8" MIN FOR ROUND POSTS OR 1" FOR T-POST STAPLES, WIRES, AND CLIPS SHOULD ALLOW FREE MOVEMENT OF
DEPTH = 1.5' THE HIGH TENSILE FENCE WIRE
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
PLASTIC/COMPOSITE: BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END
ASSEMBLIES. SEE BRACE DETAILS.
DIA = 1" MIN
DEPTH = 1.5' ALL ELECTRIC FENCES SHALL BE GROUNDED AND ALL ENERGIZERS
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
SEE ENERGIZER DETAILS.
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = ----- FT.
Date Drawing Nome
United States HT ELECTRIC FENCE Designed-------- 701-2A
Department of CATTLE. EXTERIOR Drown --------- Dote
Agriculture 7/19
CLIENT: Checked --------1--����-1
Natural Resources Approved -------�
Conservation Service COUNTY: -------------- Sheet of
HIGH TENSILE NON-ELECTRIC FENCE
�
MIN. 2" FOR WOOD POSTS
CATILE, INTERIOR
MIN. 1" FOR OTHER POSTS
i----------12' MAX----------i
-
-
t l
�
-
�
I
- �OW
S!
� ��3:
I- 0::
-
�
j �5�
z z0::1-
w
GROUND LINE
�(!)
'/�y��r
UNE POSTS
WIRE
12.5-GAUGE GALVANIZED WIRE, 140,000 PSI MIN. TENSILE
STRENGTH WITH A 20 YEAR SUPPLIER'S WARRANTY OR SUPPLIER
WOOD:
DIA. = 4" MIN, 2.5" FOR OSAGE ORANGE DOCUMENTATION THAT THE WIRE WILL REMAIN DURABLE FOR THE
DEPTH = 2' MIN PRACTICE LIFESPAN.
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2"
MIN. 900 LBS. BREAKING STRENGTH
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR,
TAMARACK, OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK ALL WIRE SHALL MEET ASTM A854
SHALL BE TREATED BY A METHOD LISTED IN WI CONSTRUCTION
SPEC. #10-FENCES.
FASTENERS
ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
STEEL:
STANDARD "T" POST M� 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8"
DEPTH= 2' MIN STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
RECOMMENDED LENGTH: 1. 75" MIN. FOR SOFTWOODS
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE 1" MIN. FOR HARDWOODS
STUDDED
USE BARBED STAPLES FOR WOOD POSTS
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP
GALVANIZED MANUFACTURER'S CLIPS OR 14-GAUGE WIRE MAY BE USED TO
FASTEN WIRES TO NON-WOOD POSTS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL
STAPLES, WIRES, AND CLIPS SHOULD ALLOW FREE MOVEMENT
OF THE HIGH TENSILE FENCE WIRE
FIBERGLASS:
DIA. = 7/8" MIN FOR ROUND POSTS OR 1" FOR T-POST
DEPTH = 2' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
GROUNDING
IT IS RECOMMENDED THAT FENCES WITHOUT STEEL POSTS BE
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE GROUNDED FOR LIGHTNING PROTECTION AT LEAST EVERY
QUARTER MILE. ALL LINE WIRES MUST BE GROUNDED. USE
12.5 GAUGE WIRE FOR LEAD-OUT WIRE.
-GROUND RODS
PLASTIC/COMPOSITE:
DIA. = 1" MIN MIN 4 FEET INTO GROUND
DEPTH = 2' MIN 0.5" MIN DIAMETER, GALVANIZED STEEL
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
NOTES
BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END
ASSEMBLIES. SEE BRACE DETAILS.
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length =
ame
United States HT NON-ELECTRIC FENCE Designed-------- 701-38
Department of CATTLE, INTERIOR Drawn --------- Date
Agriculture 7 19____
Checked ________ ..,.._ --11
_1_
CLIENT:
Natural Resources Approved
COUNTY: Sheet of
Conservation Service
J
STANDARD WOVEN WIRE FENCE MIN. 2" FOR WOOD POSTS SINGLE OR MULTIPLE
MIN. 1" FOR OTHER POSTS STRANDS OF EITHER
CATTLE, SHEEP/GOATS, EXTERIOR & INTERIOR BARBED WIRE OR HIGH
TENSILE SMOOTH WIRE
---------16' MAX---------� WITH A SPACING OF
- 2"-6" STARTING AT THE
'
TOP OF THE WOVEN WIRE
�
I
w �
---lf---,1--!+-+11-+-+--+-+-+--+--+--+--+-+-1f--+-+--+--+--+--+-+--+--+-1--1--+--++-1f---,l--l-+-+-
GROUND
""',)V. Y
I
I I I I
w
0
I I I I
LJ LJ 2•-3" MAX. OFF THE
GROUND
DIA. = 4" MIN 14.5-GAUGE OR HEAVIER FOR INTERMEDIATE AND STAY WIRES,
DEPTH = 2' MIN SPACED MAX. 12" APART
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2"
WOVEN WIRE TO MEET ASTM A116
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR,
TAMARACK, OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK JOP WIRES·
SHALL BE TREATED BY A METHOD LISTED IN WI CONSTRUCTION BARBED WIRE MEETING PART I OF WCS (110-FENCES OR HIGH
SPEC. (110-FENCES. TENSILE WIRE MEETING PART II OF WCS (110-FENCES
STEEL: FASTENERS
STANDARD "T" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8" ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
DEPTH= 1.5' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
STUDDED 1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT USE BARBED STAPLES FOR WOOD POSTS
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP GALVANIZED
MANUFACTURER'S CLIPS OR 14-GAUGE WIRE MAY BE USED TO
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL FASTEN WIRES TO NON-WOOD POSTS
NOTES GROUNDING
BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END IT IS RECOMMENDED THAT FENCES WITHOUT STEEL POSTS BE
ASSEMBLIES. SEE BRACE DETAILS. GROUNDED FOR LIGHTNING PROTECTION AT LEAST EVERY
QUARTER MILE. ALL LINE WIRES MUST BE GROUNDED. USE
A CORNER OR BEND ASSEMBLY SHALL BE USED WHEN THE 12.5 GAUGE WIRE FOR LEAD-OUT WIRE.
HORIZONTAL ALIGNMENT CHANGES MORE THAN 15 DEGREES AND A
PULL ASSEMBLY SHALL BE USED WHEN VERTICAL ALIGNMENT CHANGES -GROUND RODS
MORE THAN 15 DEGREES. A CORNER OR BEND ASSEMBLY WILL BE MIN 4 FEET INTO GROUND
USED ONLY WHEN IT WILL NOT AFFECT THE INTEGRITY OF THE FENCE. 0.5" MIN DIAMETER, GALVANIZED STEEL
PULL ASSEMBLIES SHALL BE INSTALLED AT INTERVALS NOT TO EXCEED
660 FEET. THE CONTINUITY OF THE WIRE SHALL BE INTERRUPTED AT
THE PULL ASSEMBLY.
REFER TO WI CONSTRUCTION SPEC (110-FENCES FOR MORE SPECIFIC INFORMATION I Fence Length = FT.
USDA
uu,e 1 urawmg Name
United States STANDARD WOVEN WIRE FENCE Designed-------- 701-4A
Department of CATTLE, SHEEP/GOATS, EXTERIOR & INTERIOR
� Drawn --------- Date
Agriculture 7/19
CLIENT: Checked --------1--����-1
Natural Resources Approved --------
Conservation Service COUNTY: Sheet of
HT WOVEN WIRE FENCE
CATILE, SHEEP OR GOATS,
EXTERIOR & INTERIOR
j
MIN. 2" FOR WOOD POSTS
MIN. 1" FOR OTHER POSTS
SINGLE OR MULTIPLE
STRANDS OF EITHER
BARBED W IRE OR H IGH
TENSILE SMOOTH W IRE W ITH
1,___________ 25' MAX-----------1 A SPACING OF 2"-6"
1 I STARTING AT TH E TOP OF
l
THE WOVEN WIRE
+ -+----+� -
- --------------------- - -
---+ --+
�g�
i-- ���
J
:::c
'q' �5�
z
w
...J
----=;:��$=1��������������:!!:=������**=:!!:=��G�R�OU ND�LINE
� !:!J i..
��1-
:::c
I I '/�>0W I I ·�·
w I I I I � 7• MAX. OFF TH E
GROUND WITH A W IRE
LJ
Cl
lJ ALONG THE GROUND IF
ELECTRIF IED
OTH ERWISE, 2"-3"
LINE POSTS
ALL STEEL POSTS WILL BE ROLLED FROM H IGH CARBON STEEL RECOMM ENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
1" MIN. FOR HARDWOODS
REFER TO W I CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATIO N I Fence Length = ----- FT.
USDA
Date Drawing Nome
United States HT WOVEN WIRE FENCE Designed-------- 701-5A
Department of CATTLE, SH EEP/GOATS, EXT ERIOR & I NT ERIOR Drown --------- Dote
Agriculture 1/ 1 9
CLIENT: Checked ________ ...,.._. _ _ ��--11
Natural Resources Approved
Conservation Service COUNTY: Sheet of
HIGH TENSILE PERMANENT ELECTRIC FENCE
SHEEP/GOATS, EXTERIOR
i-----------30' MAX----------------i
50' MAX IF LAND SLOPE < 5% OR MIN. 2" FOR WOOD POSTS
100' MAX IF STAYS ARE PLACED EVERY 33' MIN. 1" FOR OTHER POSTS
�
STAY _l
z
w
....J
GROUND LINE
I I
w
0
I I
LINE POSTS
WOOD:
DIA. = 4" MIN, 2.5" FOR OSAGE ORANGE 12.5-GAUGE GALVANIZED WIRE, 140,000 PSI MIN. TENSILE
DEPTH = 2' MIN STRENGTH WITH A 20 YEAR SUPPLIER'S WARRANTY OR SUPPLIER
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2" DOCUMENTATION THAT THE WIRE WILL REMAIN DURABLE FOR THE
PRACTICE LIFESPAN.
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR,
TAMARACK, OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK MIN. 900 LBS. BREAKING STRENGTH
SHALL BE TREATED BY A METHOD LISTED IN WI CONSTRUCTION
SPEC. #10-FENCES. ALL WIRE SHALL MEET ASTM A854
STEEL: FASTENERS
STANDARD "T" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8"
ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
DEPTH = 1.5'
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
STUDDED
1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT
USE BARBED STAPLES FOR WOOD POSTS
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP
GALVANIZED
USE INSULATED MANUFACTURER'S CUPS TO FASTEN WIRES TO
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL STEEL POSTS
DIA. = 1" MIN ALL ELECTRIC FENCES SHALL BE GROUNDED AND ALL ENERGIZERS
DEPTH = 1.5' SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" SEE ENERGIZER DETAILS.
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length FT.
Date Drawing Nome
United States HT ELECTRIC FENCE Designed-------- 701-2G
Department of SHEEP /GOATS, EXTERIOR
Drawn --------- Dote
Agriculture 7/19
Checked --------t--����-1
Natural Resources CLIENT:
1
z
w
...J
GROUND LINE
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT USE INSULATED MANUFACTURER'S CUPS TO FASTEN WIRES TO
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP GALVANIZED STEEL POSTS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL USE MANUFACTURER'S CUPS OR 14-GAUGE WIRE TO FASTEN
WIRES TO FIBERGLASS AND PLASTIC/COMPOSITE POSTS
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length FT.
Drawing Nome Dote
United States HT ELECTRIC FENCE Designed-------- 701-2H
Department of SHEEP/GOATS, INTERIOR Drown --------- Dote
Agriculture 7/19
CLIENT: Checked -------- .....����"'
Natural Resources
Conservation Service
Approved --------
COUNTY: Sheet of
HIGH TENSILE NON-ELECTRIC FENCE
SHEEP/GOATS, EXTERIOR s
MIN. 2" FOR WOOD POSTS
i-----------12' MAX-----------i _:i 1" FOR OTHER POSTS
-
-- •
T
�
-�
- �- I
-- ---
t
�
I v
b
z
w
...J
GROUND LINE
'/�y��r -X)C../,T
I
I I .. V,.TY
I I IWIRE SPACING FROM GROUND:
w I I I I 6" TO 42"
I I LJ
.!iQIES.
BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END
ASSEMBLIES. SEE BRACE DETAILS.
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = _____ FT.
Date Drawing Name
United States HT NON-ELECTRIC FENCE Designed-------- 701-3C
Department of SHEEP /GOATS, EXTERIOR
Drawn --------- Date
Agriculture 7/19
CLIENT: Checked-------- ....����...
Natural Resources Approved --------
Conservation Service COUNTY: Sheet of
HIGH TENSILE NON-ELECTRIC FENCE
SHEEP/GOATS , INTERIOR �
MIN. 2" FOR WOOD POSTS
i----------12' MAX-----------i 1" FOR OTHER POSTS
�
-
--
1
�
� t
- � w5:� a.
-
ow
I �£15 t- Ct:
oli=
-
LJJLJ.J
lJ.. J: C,
o::
t-
w
GROUND LINE
'/�,7�.,r •,UV:,
I I I I WIRE SPACING FROM GROUND:
I • • vr.yy
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL STAPLES, WIRES, AND CLIPS SHOULD ALLOW FREE MOVEMENT
OF THE HIGH TENSILE FENCE WIRE
FIBERGLASS:
DIA. = 7/8" MIN FOR ROUND POSTS OR 1" FOR T-POST GROUNDING
DEPTH = 2' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" IT IS RECOMMENDED THAT FENCES WITHOUT STEEL POSTS BE
GROUNDED FOR LIGHTNING PROTECTION AT LEAST EVERY
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE QUARTER MILE. ALL LINE WIRES MUST BE GROUNDED. USE
12.5 GAUGE WIRE FOR LEAD-OUT WIRE.
-GROUND RODS
MIN 4 FEET INTO GROUND
PLASTIC/COMPOSITE:
DIA. = 1" MIN 0.5" MIN DIAMETER, GALVANIZED STEEL
DEPTH = 2' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
NQIES
BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END
ASSEMBLIES. SEE BRACE DETAILS.
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = _____ FT.
Date Drawing Nome
HT NON-ELECTRIC FENCE Designed-------- 701-3D
United States
1-------1
SHEEP/GOATS, INTERIOR Drown --------- Dote
Department of
Agriculture 7/19
CLIENT: Checked --------1-------1
Natural Resources COUNTY:
Approved
Conservation Service Sheet of
MIN. 2" FOR WOOD POSTS
MIN. 1" FOR OTHER POSTS
HT ELECTRIC WOVEN WIRE FENCE
SHEEP/GOATS, EXTERIOR & INTERIOR SINGLE OR MULTIPLE
STRANDS OF HIGH
TENSILE SMOOTH WIRE
WITH A SPACING OF
2"-6" STARTING AT THE
TOP OF THE WOVEN WIRE
1 �� . • i:iJo !l;;
r-- :i::z3:
J �5�
z0::1-
z w<!>
w
...J
GROUND LINE oq- i...
I I I I
I I I I
LJ LJ � 7" MAX. OFF TI<E
GROUND WITH A WIRE
ALONG THE GROUND IF
ELECTRIFIED. OTHERWISE
2·-3·
LINE POSTS
.wJRE
WOOD: 12.5-GAUGE OR HEAVIER WIRE WITH CLASS 3 GALVANIZING
DIA. = 4• MIN FOR TOP AND BOTTOM STRANDS OF WOVEN WIRE
DEPTH = 2' MIN
14.5-GAUGE OR HEAVIER WIRE WITH CLASS 3 GALVANIZING
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2"
FOR INTERMEDIATE AND STAY WIRES, SPACED MAX. 12" APART
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR, FOR NON-ELECTRIC WOVEN WIRE AND 24" WHEN THE WIRE IS
TAMARACK, OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK ELECTRIFIED.
SHALL BE TREATED BY A METHOD LISTED IN WI CONSTRUCTION
SPEC. #10-FENCES. WOVEN WIRE TO MEET ASTM A641
JOP WIRES·
STEEL: HIGH TENSILE WIRE MEETING PART II OF WCS #10-FENCES
STANDARD i" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8"
DEPTH= 1.5' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
POSTS SHALL BE UV PROTECTED FOR THE LIFE OF THE FENCE STAPLES, WIRES, AND CLIPS SHOULD ALLOW FREE MOVEMENT
OF THE HIGH TENSILE FENCE WIRE
!::!.OIES.
BRACES ARE REQUIRED AT ALL CORNERS, GATES, AND END GROUNDING
ASSEMBLIES. SEE BRACE DETAILS.
ALL ELECTRIC FENCES SHALL BE GROUNDED AND ALL
PULL ASSEMBLIES ARE NOT NEEDED FOR HIGH-TENSILE WOVEN ENERGIZERS SHALL BE INSTALLED PER MANUFACTURER'S
WIRE. RECOMMENDATIONS. SEE ENERGIZER DETAILS.
TENSION OF FENCE SHOULD BE SET SUCH THAT THE SAG BETWEEN
POSTS IS 1 INCH OR LESS
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION I Fence Length = FT.
----------30' MAX----------.
50' MAX IF LAND SLOPE < 5% OR
100' MAX IF STAYS ARE PLACED EVERY 33' __:::i_
MIN. 2" FOR WOOD POSTS
1" FOR OTHER POSTS
STAY
I
:::c
z
w
....J
GROUND LINE
:::c I I I I IRE SPACING FROM GROUND:
w
Cl
I I I I 3
4
WIRE: 28, 38", 48"
WIRE: 18" TO 48" (MIN. 2 HOT)
LJ 5 WIRE: 18" TO 54" (MIN. 3 HOT)
LINE POSTS
WOOD: 12.5-GAUGE GALVANIZED WIRE, 140,000 PSI MIN. TENSILE
DIA. = 4" MIN, 2.5" FOR OSAGE ORANGE STRENGTH WITH A 20 YEAR SUPPLIER'S WARRANTY OR SUPPLIER
DEPTH = 2' MIN DOCUMENTATION THAT THE WIRE WILL REMAIN DURABLE FOR THE
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2" PRACTICE LIFESPAN.
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR, MIN. 900 LBS. BREAKING STRENGTH
TAMARACK, OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK
SHALL BE TREATED BY A METHOD LISTED IN WI CONSTRUCTION ALL WIRE SHALL MEET ASTM A854
SPEC. #10-FENCES.
FASTENERS
STEEL: ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
STANDARD "T" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8" STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
DEPTH = 1.5'
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE
STUDDED USE BARBED STAPLES FOR WOOD POSTS
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP GALVANIZED USE INSULATED MANUFACTURER'S CUPS TO FASTEN WIRES TO
STEEL POSTS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL
USE MANUFACTURER'S CLIPS OR 14-GAUGE WIRE TO FASTEN
WIRES TO FIBERGLASS AND PLASTIC/COMPOSITE POSTS
FIBERGLASS:
STAPLES, WIRES, AND CUPS SHOULD ALLOW FREE MOVEMENT
DIA. = 7/8" MIN FOR ROUND POSTS OR 1" FOR T-POST OF THE HIGH TENSILE FENCE WIRE
DEPTH = 1.5'
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END
ASSEMBLIES. SEE BRACE DETAILS.
POSTS SHALL BE UV PROTECTED FOR THE LIFE OF THE FENCE
ALL ELECTRIC FENCES SHALL BE GROUNDED AND ALL ENERGIZERS
SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
SEE ENERGIZER DETAILS.
----- FT.
_____..
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length
Date Drawing Name
United States HT ELECTRIC FENCE Designed-------- 701-2C
Department of HORSE, EXTERIOR
Drawn --------- Date
Agriculture 7/19
CLIENT: Checked -------�a-------1
Natural Resources
Conservation Service COUNTY: -------------- Approved -------�
Sheet of
HIGH TENSILE PERMANENT ELECTRIC FENCE
HORSES, INTERIOR
-----------50' MAX---------•
70' MAX IF INTERIOR LANE FENCE
I
MIN. 2" FOR WOOD POSTS
MIN. 1" FOR OTHER POSTS
r�g�•
CX)
�o
z�
t") lJJ::::, Q.
��g
we>
lJ...
GROUND LINE
STANDARD "T" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8" STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
DEPTH = 1.5'
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE
STUDDED USE BARBED STAPLES FOR WOOD POSTS
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT USE INSULATED MANUFACTURER'S CLIPS TO FASTEN WIRES TO
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP GALVANIZED STEEL POSTS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL USE MANUFACTURER'S CLIPS OR 14-GAUGE WIRE TO FASTEN
WIRES TO FIBERGLASS AND PLASTIC/COMPOSITE POSTS
FIBERGLASS:
STAPLES, WIRES, AND CLIPS SHOULD ALLOW FREE MOVEMENT OF
DIA. = 7/8" MIN FOR ROUND POSTS OR 1" FOR T-POST THE HIGH TENSILE FENCE WIRE
DEPTH = 1.5'
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
DIA. = 1" MIN ALL ELECTRIC FENCES SHALL BE GROUNDED AND ALL
DEPTH = 1.5' ENERGIZERS SHALL BE INSTALLED PER MANUFACTURER'S
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" RECOMMENDATIONS. SEE ENERGIZER DETAILS.
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = FT.
Date Drawing Name
United States
Department of HT ELECTRIC FENCE Designed-------- 701-20
1-------1
HORSE, INTERIOR Drawn --------- Date
Agriculture 7/19
Checked --------1-------1
Natural Resources CLIENT:
i----------30' MAX----------i
50' MAX IF LAND SLOPE < 5% OR
100' MAX IF STAYS ARE PLACED EVERY 33'
;��
STAY
/ MIN. 2" FOR WOOD POSTS
MIN. 1" FOR OTHER POSTS
I
--�H----��------++-----------+-1--""'--
• Wc
<X) :I:z:3:
z
w
I') �5�
....J ��1-
GROUND LINE
�--�-LJ LJ
WIRE
UNE POSTS
12.5-GAUGE GALVANIZED WIRE, 140,000 PSI MIN. TENSILE
WOOD: STRENGTH WITH A 20 YEAR SUPPLIER'S WARRANTY OR SUPPLIER
DIA. = 4" MIN, 2.5" FOR OSAGE ORANGE DOCUMENTATION THAT THE WIRE WILL REMAIN DURABLE FOR THE
PRACTICE LIFESPAN.
DEPTH = 2' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2" MIN. 900 LBS. BREAKING STRENGTH
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR, METALLIC-COATED STEEL SMOOTH HT WIRE CORE WITH
TAMARACK, OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK UV-RESISTANT, WHITE, ELECTRICALLY CONDUCIVE POLYMER
SHALL BE TREATED BY A METHOD LISTED IN WI CONSTRUCTION COATING.
SPEC. /110-FENCES.
ALL WIRE SHALL MEET ASTM A854
STEEL:
FASTENERS
STANDARD "T" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8"
DEPTH= 1.5' MIN ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE
STUDDED RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP GALVANIZED USE BARBED STAPLES FOR WOOD POSTS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL USE INSULATED MANUFACTURER'S CLIPS TO FASTEN WIRES TO
STEEL POSTS
FIBERGLASS: USE MANUFACTURER'S CLIPS OR 14-GAUGE WIRE TO FASTEN
DIA. = �· MIN OR 1" AREA WIRES TO FIBERGLASS AND PLASTIC/COMPOSITE POSTS
DEPTH = 1.5' MIN
STAPLES, WIRES, AND CUPS SHOULD ALLOW FREE MOVEMENT OF
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" THE HIGH TENSILE FENCE WIRE
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE
.N..OTES.
PLASTIC/COMPOSITE: BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END
ASSEMBLIES. SEE BRACE DETAILS.
DIA. = 1" MIN
DEPTH = 1.5' MIN ALL ELECTRIC FENCES SHALL BE GROUNDED AND ALL ENERGIZERS
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
SEE ENERGIZER DETAILS.
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE
REFER TO WI CONSTRUCTION SPEC /110-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = FT.
Drawing Name
Date
United States
Department of
HT PERMANENT ELECTRIC Designed-------- 701-6A
HORSE, EXTERIOR
Drawn --------- Date
Agriculture 1_;_1_9 ____.....
Checked ________ ..,_
Natural Resources CLIENT:
I I I I
w
Cl
I I I I
LJ
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP GALVANIZED 1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL USE BARBED STAPLES FOR WOOD POSTS
NOTES
PLASTIC/COMPOSITE:
BRACES NOT REQUIRED FOR SINGLE STRAND HT ELECTRIC
DIA. = 1" MIN FENCES.
DEPTH = 1' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" ALL ELECTRIC FENCES SHALL BE GROUNDED AND ALL ENERGIZERS
SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE SEE ENERGIZER DETAILS.
POSTS SHALL BE UV PROTECTED FOR THE LIFE OF THE FENCE
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = FT.
J
INGLE STRAND OF
>--------16' MAX-------
HIGH TENSILE SMOOTH
i
WIRE WITH A SPACING
I
OF 2"-6" STARTING AT
I
- THE TOP OF THE
WOVEN WIRE
1 ��J
I��
�::::::=::=:=:=:=:=:=:=::::=:=:=:=:=:=::::=::=:=:::::::=:=: v :I:
• lJJ t-
I
.__....,H'
......,
.,)'�
......_....._";'/ ���-�X�/. 5.s�.
)V .,)',�
�
,.__
',< ...._.__...._...._.._......._......,....._....._....._4"-r
....._
���
GROUND LINE
x?.';y>1'7�
><X/.
JU);; LL.::>
�
(!)
I I I I
Vl('-l v• ·v /.YY
I
w
Cl
I I I I
LJ LJ 2"-3" MAX. OFF
THE GROUND
WOOD:
10-GAUGE OR HEAVIER FOR TOP AND BOTTOM STRANDS OF
WOVEN WIRE
FASTENERS
SPEC. #10-FENCES.
STEEL:
STANDARD "T" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8"
ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
DEPTH= 1.5' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE STUDDED RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT 1" MIN. FOR HARDWOODS
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP GALVANIZED
USE BARBED STAPLES FOR WOOD POSTS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL
MANUFACTURER'S CLIPS OR 14-GAUGE WIRE MAY BE USED TO
FASTEN WIRES TO NON-WOOD POSTS
GROUNDING
BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND
END ASSEMBLIES. SEE BRACE DETAILS. IT IS RECOMMENDED THAT FENCES WITHOUT STEEL POSTS BE
GROUNDED FOR LIGHTNING PROTECTION AT LEAST EVERY
A CORNER OR BEND ASSEMBLY SHALL BE USED WHEN THE QUARTER MILE. ALL LINE WIRES MUST BE GROUNDED. USE
HORIZONTAL ALIGNMENT CHANGES MORE THAN 15 DEGREES AND 12.5 GAUGE WIRE FOR LEAD-OUT WIRE.
A PULL ASSEMBLY SHALL BE USED WHEN VERTICAL ALIGNMENT
CHANGES MORE THAN 15 DEGREES. A CORNER OR BEND -GROUND RODS
ASSEMBLY WILL BE USED ONLY WHEN IT WILL NOT AFFECT THE MIN 4 FEET INTO GROUND
INTEGRITY OF THE FENCE. 0.5" MIN DIAMETER, GALVANIZED STEEL
USDA
Date Drawing Name
United States STANDARD WOVEN WIRE FENCE Designed 701-48
Department of HORSE, EXTERIOR & INTERIOR Date
Drawn
Agriculture 7/19
i----------30' MAX----------i
50' MAX IF LAND SLOPE < 5% OR
100' MAX IF STAYS ARE PLACED EVERY 33' _:i
MIN. 2" FOR WOOD POSTS
1" FOR OTHER POSTS
STAY
------tr-+------t�---------1,1----------+-1---� l� '!.t
N WI
i
<!> a..
w�
:i:::o
Uo
�z
LL.::)
0
GROUND LINE et:
<!>
LJ
PLASTIC/COMPOSITE:
BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END
DIA. = 1" MIN ASSEMBLIES. SEE BRACE DETAILS.
DEPTH = 1.5' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" ALL ELECTRIC FENCES SHALL BE GROUNDED AND ALL ENERGIZERS
SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
SEE ENERGIZER DETAILS.
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = FT.
Dote Drawing Name
United States
Department of HT ELECTRIC FENCE Designed-------- 701-21
SWINE, EXTERIOR Drawn --------- Date
Agriculture 7/19
Checked --------1--����-1
Natural Resources CLIENT:
----------50' MAX----------
70' MAX IF INTERIOR LANE FENCE
MIN. 2" FOR WOOD POSTS
MIN. 1" FOR OTHER POSTS
-----l-+-------€�----------------+-1--__J'----
• � �w
Iijjo!!;
� :i::z,r;
z � �5�
w
....J f::i�I-
GROUND LINE
LJ
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = FT.
United States HT ELECTRIC FENCE Designed--------
Department of SWINE, INTERIOR
Drown--------� Dote
Agriculture 7/19
Checked -------- .....����-1
Natural Resources
CLIENT:
J
STANDARD WOVEN WIRE FENCE
SWINE, EXTERIOR AND INTERIOR SINGLE STRAND OF
EITHER BARBED WIRE OR
I
----------16' MAX---------,,-ii HIGH TENSILE SMOOTH
-I WIRE WITH A SPACING OF
6" STARTING AT THE TOP
OF THE WOVEN WIRE
1��w
j
� • �o
z�
J���
I (X)
I') w::::> D..
I-
w
---ll--l--lll-+l--l--+-+-+-+-+--+--+-+-+-1-+-+-+--+-+--+-+-+-+-t-11-t---t+-1t--t-11-t-
GROUND LINE i...
..._ vv,T
I
I- I I I I
w
0
I I I I 2"-3" MAX. OFF
LJ LJ THE GROUND
WOOD:
DIA. = 4" MIN
DEPTH = 2' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2" 10-GAUGE OR HEAVIER FOR TOP AND BOTIOM STRANDS OF
WOVEN WIRE
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR, TAMARACK,
OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK SHALL BE 14.5-GAUGE OR HEAVIER FOR INTERMEDIATE AND STAY WIRES,
TREATED BY A METHOD LISTED IN WI CONSTRUCTION SPEC.
SPACED MAX. 12" APART
/110-FENCES.
WOVEN WIRE TO MEET ASTM A116
STEEL:
JOP WIRES:
STANDARD "T" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8" BARBED WIRE MEETING PART I OF WCS /110-FENCES OR HIGH
DEPTH= 1.5' MIN TENSILE WIRE MEETING PART II OF WCS /110-FENCES
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
REFER TO WI CONSTRUCTION SPEC /110-FENCES FOR MORE SPECIFIC INFORMATION I Fence Length = FT.
USDA ____...
Drawing Name
uate
United States STANDARD WOVEN WIRE FENCE Designed-------- 701-4D
2i Department of SWINE, EXTERIOR & INTERIOR
Drawn --------- Date
.._
Agriculture 7/19
CLIENT: Checked -------�1-------1
Natural Resources Approved --------
COUNTY:
Conservation Service Sheet of
HIGH TENSILE PERMANENT ELECTRIC FENCE
BISON, EXTERIOR
----------30' MAX------------<
50' MAX IF LAND SLOPE < 5% OR MIN. 2" FOR WOOD POSTS
-----
1oo· MAX IF STAYS ARE PLACED EVERY 33' MIN. 1" FOR OTHER POSTS
STAY
- �
�
•
-�
1�g�
�
- �
I
- t We-
N :I:z:3:
-� LO w::::> a.
I
bz � uo o
-
z0::1-
w<!>
w
....J
i...
GROUND LINE
I
V'X.X..,::Y
I
I I 'V�,r�
I I w1RE SPACING FROM GROUND:
w I I I I 1 12· TO 52"
I I LJ
LINE POSTS
WIRE
WOOD: 12.5-GAUGE GALVANIZED WIRE, 140,000 PSI MIN. TENSILE
DIA. = 4" MIN, 2.5" FOR OSAGE ORANGE STRENGTH WITH A 20 YEAR SUPPLIER'S WARRANTY OR SUPPLIER
DEPTH = 2' MIN DOCUMENTATION THAT THE WIRE WILL REMAIN DURABLE FOR THE
PRACTICE LIFESPAN.
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2"
MIN. 900 LBS. BREAKING STRENGTH
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR, TAMARACK,
OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK SHALL BE ALL WIRE SHALL MEET ASTM A854
TREATED BY A METHOD LISTED IN WI CONSTRUCTION SPEC.
#10-FENCES.
STEEL: FASTENERS
STANDARD "T" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8" ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
DEPTH= 1.5' MIN STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE
STUDDED 1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT USE BARBED STAPLES FOR WOOD POSTS
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP
GALVANIZED USE INSULATED MANUFACTURER'S CLIPS TO FASTEN WIRES TO
STEEL POSTS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL
USE MANUFACTURER'S CLIPS OR 14-GAUGE WIRE TO FASTEN WIRES
TO FIBERGLASS AND PLASTIC/COMPOSITE POSTS
FIBERGLASS:
DIA. = 7/8" MIN FOR ROUND POSTS OR 1" FOR T-POST STAPLES, WIRES, AND CLIPS SHOULD ALLOW FREE MOVEMENT OF
DEPTH = 1.5' MIN THE HIGH TENSILE FENCE WIRE
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length ----- FT.
e Drawing Name
United States 701-2E
Department of
HT ELECTRIC FENCE Designed--------
I _l
MIN. 2" FOR WOOD POSTS
MIN. 1" FOR OTHER POSTS
50' MAX-----------,•-i-
70' MAX IF INTERIOR LANE FENCE
I-CD..
-----if-+-------++-----------------+-1-----�5���
----+-+------<E,.,..----------------H----
��ffi��
GROUND LINE
LINE POSTS
.wIB..E.
WOOD: 12.5-GAUGE GALVANIZED WIRE, 140,000 PSI MIN. TENSILE
DIA. = 4" MIN, 2.5" FOR OSAGE ORANGE STRENGTH WITH A 20 YEAR SUPPLIER'S WARRANTY OR SUPPLIER
DEPTH = 2' MIN DOCUMENTATION THAT THE WIRE WILL REMAIN DURABLE FOR THE
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2" PRACTICE LIFESPAN.
STEEL: FASTENERS
STANDARD i" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8" ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
DEPTH= 1.5' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE STUDDED RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP GALVANIZED USE BARBED STAPLES FOR WOOD POSTS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL USE INSULATED MANUFACTURER'S CLIPS TO FASTEN WIRES TO
STEEL POSTS
FIBERGLASS:
USE MANUFACTURER'S CLIPS OR 14-GAUGE WIRE TO FASTEN
DIA. = 7/8" MIN FOR ROUND POSTS OR 1" FOR T-POST WIRES TO FIBERGLASS AND PLASTIC/COMPOSITE POSTS
DEPTH = 1.5' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" STAPLES, WIRES, AND CLIPS SHOULD ALLOW FREE MOVEMENT OF
THE HIGH TENSILE FENCE WIRE
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE
PLASTIC/COMPOSITE: NOTES
DIA. = 1" MIN BRACES ARE REQUIRED AT ALL CORNERS, GATES, PULL AND END
DEPTH = 1.5' MIN ASSEMBLIES. SEE BRACE DETAILS.
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1"
ALL ELECTRIC FENCES SHALL BE GROUNDED AND ALL ENERGIZERS
POSTS SHALL BE DURABLE FOR THE LIFE OF THE FENCE SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
SEE ENERGIZER DETAILS.
POSTS SHALL BE UV PROTECTED FOR THE LIFE OF THE FENCE
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length
Dote
United States
Department of
HT ELECTRIC FENCE Designed--------
z
w
...J
I I I I
v• •X/,�
w
0
I I I I
LJ LJ 2"-3" MAX. OFF
THE GROUND
LINE POSTS
12.5-GAUGE OR HEAVIER WIRE WITH CLASS 3 GALVANIZING
WOOD: FOR TOP AND BOTTOM STRANDS OF WOVEN WIRE
DIA. = 5" MIN
14.5-GAUGE OR HEAVIER WIRE WITH CLASS 3 GALVANIZING
DEPTH = 2' MIN
FOR INTERMEDIATE AND STAY WIRES, SPACED MAX. 12" APART
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2" FOR NON-ELECTRIC WOVEN WIRE AND 24" WHEN THE WIRE IS
ELECTRIFIED.
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR,
TAMARACK, OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK WOVEN WIRE TO MEET ASTM A641
SHALL BE TREATED BY A METHOD LISTED IN WI CONSTRUCTION
SPEC. #10-FENCES.
JOP WIRE·
BARBED WIRE MEETING PART I OF WCS #10-FENCES OR HIGH
STEEL: TENSILE WIRE MEETING PART II OF WCS #10-FENCES
STANDARD T POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8"
DEPTH= 1.5' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" FASTENERS
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
STUDDED
STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
GALVANIZED 1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL USE BARBED STAPLES FOR WOOD POSTS
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION I Fence Length = ----- FT.
!lE�r
S ANDARD WOVEN WIRE FENCE MIN . 1" FOR OTHER POSTS
T
O R E D IN E R R
U LT T � = T
-- P- _ _ _ _ Y_ ._ _ _X , �:
'
i --- - _
· - - _ _ _ -10- ------i ' J
M i
I _
STARTING AT THE TOP OF
THE WOVEN WIRE
.........11,.....1.,-�--r-���-r-�--.--r-.,........,,.........--r-........--r----,-----.----,---.--r-.---.r--r--,+-,l--,--'r-
l-r-r-
1�g�
: �Cj:
J
N Z
I"- w::::>Q.
��g
z
w
...J ---ll--l--lll-+l--l-+-+-+-+-+--+--+--+-+-1-+-+-+-+-+----111 '--+-+-+-t-lt-t---t+-11--t-11-t-
GROUND LINE
''A/'7
I I I I
w
0
I I I I
LJ CHICKEN/TURKEY--2" X 4" WOVEN WIRE
LJ 2"-3" MAX. OFF
THE GROUND
LINE POSTS
WIRE
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP GALVANIZED 1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL USE BARBED STAPLES FOR WOOD POSTS
_____..
REFER TO WI CONSTRUCTION SPEC #10 FENCES FOR MORE SPECIFIC INFORMATION
'
�
1��w
• :i:::
G:io\l§
J���
I N z>
I'- w=>Q.
w I
__,__,_,......-+_-+-+-+--+--+--+--+-+--1--+-_-+-_--+---+-_-+-........,,........-+
--++--1>--<---+- GROUND LINE
I
LL.
,.;v.,
I
I I I I
w I I I I 2"-3" MAX. OFF
LJ CHICKEN/TURKEY--2" X 4" WOVEN WIRE LJ THE GROUND
WIRE
LINE POSTS
12.5-GAUGE OR HEAVIER WIRE WITH CLASS 3 GALVANIZING
FOR TOP AND BOTTOM STRANDS OF WOVEN WIRE
WOOD:
DIA. = 5" MIN 14.5-GAUGE OR HEAVIER WIRE WITH CLASS 3 GALVANIZING
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 2" FOR INTERMEDIATE AND STAY WIRES, SPACED MAX. 12" APART
DEPTH = 2' MIN FOR NON-ELECTRIC WOVEN WIRE AND 24" WHEN THE WIRE IS
ELECTRIFIED.
ALL WOOD SPECIES EXCEPT RED CEDAR, WHITE CEDAR,
TAMARACK, OSAGE ORANGE, BLACK LOCUST, AND WHITE OAK WOVEN WIRE TO MEET ASTM A641
SHALL BE TREATED BY A METHOD LISTED IN WI CONSTRUCTION
SPEC. #10-FENCES. JOP WIRES:
BARBED WIRE MEETING PART I OF WCS #10-FENCES OR HIGH
STEEL: TENSILE WIRE MEETING PART II OF WCS #10-FENCES
STANDARD "T" POST MIN 1.25 LBS/FT, 1-3/8" X 1-3/8" X 1/8"
DEPTH= 1.5' MIN
MIN. LENGTH= FENCE HEIGHT + POST DEPTH + 1" FASTENERS
ALL STEEL POSTS WILL HAVE AN ANCHOR PLATE AND BE ALL WIRES SHALL BE ATTACHED TO EACH LINE POST
STUDDED
STAPLES SHALL BE 9-GAUGE, GALVANIZED STEEL OR HEAVIER.
ALL STEEL POSTS WILL BE PAINTED WITH A WEATHER RESISTANT
PAINT FOR STEEL, ENAMELED AND BAKED, OR HOT DIP RECOMMENDED LENGTH: 1.75" MIN. FOR SOFTWOODS
GALVANIZED 1" MIN. FOR HARDWOODS
ALL STEEL POSTS WILL BE ROLLED FROM HIGH CARBON STEEL USE BARBED STAPLES FOR WOOD POSTS
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = FT.
FIBERGLASS:
DIA. = 3/8" MIN
1. LINE POST SPACING VARIES DEPENDING ON MANUFACTURER. ADDmONAL STEP-IN POSTS MAY BE NEEDED TO REINFORCE CORNERS,
TURNS OR DIPS IN THE TERRAIN.
2. FENCE TYPE CLIPS OR JUMPERS ARE A QUICK AND EASY WAY TO ATTACH THE NETTING TO THE ELECTRIC SOURCE ESPECIALLY WITH AN
ADJOINING FENCE. MANY MANUFACTURERS HAVE CLIPS BUILT IN TO LINK SECTIONS OF NETTING TOGETHER, BUT THE ENERGIZER OR SOME
SECTION OF FENCE NORMALLY HAS TO BE SHUT OFF TO DO THIS.
3. IT IS BEST NOT TO SEPARATE MOTHERS FROM PROGENY WITH ELECTRIFIED NETTING DURING A WEANING PROCESS. USE A PHYSICAL
BARRIER FENCE INSTEAD. SOME ANIMALS HAVE A VERY STRONG HERDING INSTINCT AND MAY TRY TO GET THROUGH FENCE HOT OR NOT
TO BE ABLE TO JOIN THE ANIMALS ON THE OTHER SIDE.
4. DO NOT LEAVE NETTING OFF (NOT ENERGIZED) WHEN SHEEP, GOATS OR POULTRY ARE NEAR IT. IF YOU DO THEY LOSE THEIR FEAR.
THEN WHEN THE NET IS TURNED ON THEY CHALLENGE THE NET AND MAY BECOME ENTANGLED.
REFER TO WI CONSTRUCTION SPEC #10-FENCES FOR MORE SPECIFIC INFORMATION Fence Length = FT.
Date
United States TEMPORARY INTERIOR Designed--------
Drawing Name
701-98
Department of ENERGIZED NETTING FENCE Drawn--------- Date
Agriculture 7/19
CLIENT: Checked -------�a--����-1
Natural Resources Approved --------
Conservation Service COUNTY: Sheet of
United States
Department of
Agriculture
Natural Resources
Conservation Service
United States
Department of
Agriculture
Natural Resources
Conservation Service
·
·
·
·
·
·
··
··
··
·
United States
Department of
Agriculture
Natural Resources
Conservation Service