You are on page 1of 34

Control Valve 9SX14

DX80R

July, 2009
Overseas Product Support Team
Text No. HYD0062
Control valve

ƒ General spec of STD. valve (DX80R)

I. Maker & Model : Rexroth / 9SX14


II. Type : Pilot control
III. No. of spool : 12
IV. Spool Dia. : 14mm
V. Spool arrangement : INLET1, BM, BKT, AM, DZ, OP, TL, TR, B/SW, INLET2, SW, OUTLET
VI. LS relief valve : 280kgf/cm²
VII. Port relief vavle : 310kgf/cm²
VIII. Main relief valve : 340kgf/cm²

2
Control valve

ƒ Exterior view (1)

1. Inlet block
2. Boom block
3. Bucket block
4. Arm block
5. Dozer block
6. Option block
7. Travel(L) block
8. Travel(R) block
9. Boom swing block
10. Inlet-2 block
11. Swing block
12. Outlet block

3
Control valve

ƒ Exterior view (2)

1. Primary relief valve


2. LS flow regulator
3. LS relief valve
4 .Secondary relief valve
5. Flushing valve
6. T port
7. P port
8. LS port
9. T1 port
10. P2 port
11. T3 port

4
Control valve

ƒ Section view & schematics comparisons

1. housing
2. Spool
3. Check valve
4. Pressure Compensator
5. Secondary Vavle
6. Plug

5
Control valve

ƒ Drawing Anti-cavitation valve


P2

LS

LS flow regulator LS relief valve

Spool
Flushing valve
compensator

T Secondary relief valve


Primary relief valve

6
Control valve

• LS System(1)

△P = P1- P2

Q= kA√△P or △P = k(Q/A)²
Control valve

• LS System(2)
Control valve

• SX14 General (1)


Control valve

• SX14 General (2)

A1 A2
Control valve
• Flow regulator

1. Function :
-When System pressure drops down,
LS pressure doesn’t drop
immediately
-> capacity of hose
-> compensator is closed
- System pressure is higher than load
pressure
-> abnormal engine load
Flow regulator decompresses LS line
2. Remarks
Flow regulator is orifice valve installed
strainer on front of the valve
Control valve

• Flushing Valve (1)

1. Function :
- Available oil for anti-cavitation valves
- Minimum cooling function
- Safety valve.
- Ready to move each actuator.
2. Remarks
- The setting pressure would be
adjusted by inside shim.
Control valve
• Flushing Valve (2)

P LS

LS pressure Set pressure


Neutra 0bar 25bar
Operation LS LS + 25bar
Control valve

• Primary relief valve

1.Function :
- Restrict the max system pressure
2.Remarks
- The primary valve is the same as a
secondary valve
- Setting Pressure
Primary valve : 340bar
Secondary valve :310bar
Control valve

• LS relief valve (1)

1.Function :
- Restrict the max LS pressure
2.Remarks
- The setting pressure of LS relief
valve is 280bar
Control valve

• LS relief valve - Max System pressure (2)

Max pump pressure = Max work port pressure


Pmax setting :
System Pressure : M Port
Dead end a movement
Set LS relief
Check pump pressure at M port
Control valve

• LS relief valve - Normal Movement (3)

Moving actuator : Pump pressure < Max Pressure

Pump – 15 bar

0
bar

15
bar

Spool : Meter in
15
bar
Compenasator
Orifice

P
Pump
Control valve

• LS relief valve- Dead ended Movement (4)

Stalled actuator
pump pressure = max pressure
P pump

15 bar
~ 0 bar

15 bar Spool
meter in
Compensator
orifice

P pump
Control valve

• Flow System (1)


Control valve

• Flow System (2)


Control valve

• Flow System (3)


Control valve

• Flow System (4)


Control valve
• Flow System (5)
Control valve

• Flow System (6)


Control valve

• Flow System (8)


Control valve

• Flow System (9)


Control valve

• Flow System (10)


Control valve

• Flow System (11)


Control valve

• Flow System(12)
Control valve

• Flow System of Compensator


Control valve

• Flow System of Compensator(1)


Control valve

• Flow System of Compensator(2)

Actuation
Control valve

• Flow System of Compensator(3)

Actuation Actuation
Control valve

• Spools ( Boom.Arm Bucket,Swing..)

A Type

B Type

Marking

Type Spool Remarks


A Type Boom The marking of the spool must be A port

B Type Arm, Bucket, Dozzer, Travel, Option, B/Swing,Swing The marking of the spool must be B port

You might also like