You are on page 1of 1

Bhopal Metro Rail Project

Package BH-06

Sr. Tender Clause/Sub- Clause Description (relevant portion) as Clause Description (relevant portion) as
No. Document Clause/Para existing in the Tender Documents amended now to be read as
Reference (Page No)

Systems
(Part 2)

52 Volume IV, Chapter 24, 24.12, Technical Data Sheet -Hume Pipe Technical Data Sheet -Hume Pipe
TS-E&M Table, Sr. No. 3 Type- NP2 Type- NP3
System (304 of 524)
(Part 2)

53 Volume IV, 28.5, 1st Fans shall be AMCA certified DIDW centrifugal, Fans shall be AMCA certified for air, sound as per
st
TS-E&M paragraph, 1 line forward inclined blades. AMCA 211, AMCA 311, and FEI, DIDW centrifugal,
System (344 of 524) forward inclined blades.
(Part 2)

54 Volume IV, 30.4, (1st bullet The exhaust air blower shall be long casing Tube The exhaust air blower shall be long casing Tube
TS-E&M point) Axial Flow fans connected to the duct & shall be of Axial Flow fans connected to the duct & shall be of
System (353 of 524) floor / ceiling / wall mounted type as specified in the floor / ceiling / wall mounted type as specified in the
(Part 2) Bill of Quantities. The capacity of tube axial flow Bill of Quantities. The capacity of tube axial flow
fans, diameter, maximum motor H.P & static fans, diameter, maximum motor H.P & static
pressure, etc. shall be according to schedule of pressure, etc. shall be according to schedule of
equipment & Bill of Quantities. The noise level of equipment & Bill of Quantities. The noise level of
axial fan shall be less than 80 dBA at 2.5 meters axial fan shall in compliance with AMCA standards.
from the fan.

Corrigendum – 2, Date: 10.11.2021 Page 19 of 80