QA/QC Procedure Rev. No.: 0
12. Element Serial no 13. Items to be inspected 14. Quantity 15. Drawings no/ remarks
FINAL COUPLING ADJUSTMENT BETWEEN
ELECTRICAL MOTOR N0.1 AND MAIN PUMP 52-YB20-M-601 REV.A
N/A N0.1 N/A
16.
18.
KHATIB & ALAMI
19. General Comments
Signature
Fluke 830 LASER ALIGNM ENT TOOL Report
File info
Filename: MSH300-2T PS2E PP1 FINAL ALIGNMENT
Created: June/27/2021, 11:37:36 am
Measured: July/01/2021, 11:02:15 am
Comment:
Machine dimensions
Value: Unit:
Static
Coupling
Coupling diameter: 343 [mm]
Distance from sensor to prism 582 [mm]
Distance from sensor to coupling center: 292 [mm]
Distance to right machine: 790 [mm]
RPM: 3577 RPM
Movable
Distance from 1 to 2 Feet: 3185 [mm ]
Dimensions [mm]
Pf 577
790 3 185
Vertical:
Gap +0.03 [mm]
Offset -0.20 [mm]
Vertical tolerance:
Horizontal:
Gap -0.04 [mm ]
Offset +0.03 [mm]
Horizontal tolerance: I
Machine foot corrections
Static
Movable Vertical: Horizontal: Unit:
Foot 1 +0.28 -0.13 [mm]
Foot 2 +0.58 -0.52 [mm]
Verti ca l
Gap +0.03
Offset -0. 20 +0. 28 +0.58
Horizontal I
Gap -0.04
Offset +0.03 -0.13 -0.52
Tolerances
Coupling Value: Unit:
RPM 3577
Excellent:
Gap 0.10 [mm]
Offset 0.03 [mm]
Acceptable:
Gap 0.13 [mm]
Offset 0.05 [mm]