Service Bulletin

Copier B/W
Issued by Canon Europa N.V.
HARDWARE

Model: Ref No.:


iR1022A iR1022-006
iR1022F (F1-T01-N00-10014-01)
iR1022i
Date:
iR1022iF
December, 2008
iR1024A
iR1024F
iR1024i
iR1024iF
iR1024N

Location:
ADF Assembly
Subject:
Preventing the installation part of the Hinge Units of the Base Frame from being broken
Detail:
<Symptom>
Repeated opening and closing the ADF may break the installation part of the Hinge Units [2] of the Base Frame [1].

(1/6)
iR1022-006

P-1 ADF Assembly

[1] Frame, Base [2] Hinge Unit

<Cause>
Stress generated at opening and closing the ADF is concentrated to the installation part of the Hinge Units of the Base
Frame, causing a broken Base Frame.

<Factory Measures>
The thickness of the Ribs [3] of the installation part of the Hinge Units of the Base Frame is changed. The shape [4]
of the Hinge Units is changed accordingly.

(2/6)
iR1022-006

P-2 Frame, Base

[A] Old Type [B] New Type

[3] Change in the thickness of the Rib

(3/6)
iR1022-006

P-3 Hinge Unit

[A] Old Type [B] New Type

[4] Point of shape change

Servicing Work:
A new setting of the Hinge Unit (FM2-8210-000) that is a set of the new type of the Hinge Unit and the Spacer [5]
is made.

a. If the above symptom occurs, replace the new type of the Base Frame and the Hinge Units simultaneously. There
is no need to install the Spacer.
b. When installing the new type of the Hinge Units to the old type of the Base Frame, install the Spacer.

(4/6)
iR1022-006

P-4 Hinge Unit (FM2-8210-000)

[5] Spacer

Service Parts:

Simultaneous
No. Parts Number Description Q'ty Fig No.
Replacement

Old FL2-3983-000 FRAME, BASE 1->0


1 A2 161
New FL2-3983-010 FRAME, BASE 0->1

Old FM2-4974-000 HINGE UNIT 2->0


2 A2 161
New FM2-8210-000 HINGE UNIT 0->2

Supply of the new part(s) will follow a normal supply pattern.

(5/6)
iR1022-006
Affected Machines:

iR1023N 120V : TJE30485 and later iR1022A EU 230V : TJG43576 and later

iR1022A GB 230V : TTR01941 and later iR1022N 230V : DLD00473 and later

iR1022F EU 230V : TJJ18537 and later iR1022F 230V : MFR01691 and later

iR1022F AU 230V : MFS00834 and later iR1022F KR 220V : MFT01065 and later

iR1022F TW 120V : TJP00057 and later iR1022F GB 230V : TTS00951 and later

iR1022i EU 230V : TJQ12461 and later iR1022i GB 230V : TTT00377 and later

iR1022iF 230V : MFU04589 and later iR1022iF AU 230V : MFV02853 and later

iR1023iF 120V : TJR55888 and later iR1022iF CN 220V : TJU01669 and later

iR1022iF EU 230V : TJW38443 and later iR1022iF GB 230V : TTU00957 and later

iR1025N 120V : DQX01188 and later iR1024A EU 230V : DQY04547 and later

iR1024N 230V : DQZ00017 and later iR1024F EU 230V : DRA01449 and later

iR1024F 230V : DRB00144 and later iR1024F AU 230V : DRE00081 and later

iR1024i EU 230V : DRK01382 and later iR1025iF 120V : DRL02795 and later

iR1024iF 230V : DRM00267 and later iR1024iF AU 230V : DRN00417 and later

iR1024iF EU 230V : DRQ03342 and later