You are on page 1of 8

TEST PROJECT

Revision: B
Job No: 18705 Page: C/01
Calcs By: RKR Date: 28/01/2022

Data Input

Concrete density 25.0 kN/m3


yfgk 1.40 Factor for Dead loads
yfqk 1.60 Factor for Imposed Loads
Brickwork Density, 23.0 kN/m3
Screed Density 24.0 kN/m3
Height of Floors 3.0
Imposed Load on Slabs 3.0
Imposed Load from Floor Finishes 23.0
Load Takedown Calculations

First up we have to take into account the roof loads


1) ROOF
a) Dead Load

Provide Dimensions of tributary area Roof Pitch = 30


Length = 1.6 WIDTH = 1.85

or Just Area straight away


Area = 2.96 sqm (This is length x width)

Provide the dead load factor for the type of roof and state the code

Factor = 1 kN/m2 Code of practice and location =

Thus the dead load component due to the roof is = 1 X

= 3.417914 kN

b) Live Load
All the same data input as above applies in this section so

Provide the live load factor for the type of roof and state the code

Factor = 1.2 Kn/m2 Code of practice and location =

Thus the live load component due to the roof is = 1.2 X

= 4.101496 kN

Next up we have to take into account the slab loads


2) Slab
a) Dead Load

Provide Dimensions of tributary area Slab Thickness = 0.2


LENGTH = 1.6 WIDTH = 1.85

or Just Area straight away


Area = 2.96 sqm (This is length x width)

Provide the unit weight of concrete in this component

Gamma = 24 kN/m3 Code of practice and location =


Thus the dead load component due to the slab is = 24 X

= 17.76 kN

b) Live Load
All the same data input as above applies in this section so

Provide the live load factor for the type of floor area usage and state the code

Factor = 2 Kn/m2 Code of practice and location =

Thus the live load component due to the roof is = 2 X

= 5.92 kN

c) Load Bearing Walls on slabs


Provide the Length and height of these walls Unit Weight of the Bricks
Width of wall , Default 230 m
Length = 0 metres (provide the length to the next support in metres)
Height = 0 metres (provide the length to the next support in metres)

Load distributed to the floors


= 0 X 0 X 0.23
= 0 kN

Next up we have to take into account the beam loads


3) Beams
a) Dead Load

Provide Dimensions of tributary area Beam Depth = 0.6


LENGTH = 1.6 metres (provide the length to the next support in metres)
WIDTH = 1.85 metres (provide the length to the next support in metres)

or Just total length straight away

= 3.45 metres

Provide the unit weight of concrete in this component

Gamma = 24 kN/m3 Code of practice and location =

Thus the dead load component due to the roof is = 24 X

= 9.94 kN
b) Load Bearing Walls on beams
Provide the Length and height of these walls Unit Weight of the Bricks
Width of wall , Default 230 m
Length = 3.45 metres (provide the length to the next support in metres)
Height = 3 metres (provide the length to the next support in metres)

Load distributed to the floors


= 3 X 3.45 X 0.2
= 45.54 kN

Next up we have to take into account the column loads

4) Columns Type Rectangle


a) Dead Load

Provide Dimensions of tributary area Section Depth = 0.2


or provide CIRCLE section diameter

Height of the column is =


Unequal individual Columns = 3
or Thus average or just the Equal Height = 3 metres

Provide the unit weight of concrete in this component = 24 kN/m3

Thus the total Load is = 24 X 3 X 0.0400

= 2.88 kN

Next up we have to take into account the stub of the column just before the base
5) Stub Column Type Rectangle
a) Dead Load

Provide Dimensions of tributary area Section Depth = 0.2


or provide section diameter

Height of the column is = 1.5 metres

Provide the unit weight of concrete in this component = 24 kN/m3

Thus the total Load is = 24 X 1.5 X 0.0400

= 1.44 kN
Degrees Reduction factor = 1.155
(provide the length to the next support in metres)
(provide the length to the next support in metres)

ASCE 2002

2.96 X 1.155

ASCE 2002

2.96 X 1.155

metres Screed Thickness = 0.050


(provide the length to the next support in metres)
(provide the length to the next support in metres)

BS
2.96 X 0.250 Unit weight by the area by the thickness

BS

2.96

Unit Weight of the Bricks = 23 kN/m3


Width of wall , Default 230 mm = 0.23

X 23

metres Beam Width = 0.200 metres

Thus Area of Beam Section is = 0.1200 sqm

BS

3.45 X 0.120 Unit weight by the area by the thickness


Unit Weight of the Bricks = 22 kN/m3
Width of wall , Default 230 mm = 0.2

or Indiviudal Heights

X 22

Circle Rectangle

Section Width = 0.200 metres


CIRCLE section diameter = 0.46 which gives 0.16619

Thus Area of Column Section is = 0.0400 sqm

Circle Rectangle

Section Width = 0.200 metres


de section diameter = 0.46 which gives 0.16619

Thus Area of Column Section is = 0.0400 sqm


Corner Base and Column Results Grid Position B8

Component
Dead No: Result Live No: Result
Roof = 3.42 1 3.42 4.10 1 4.10
Slabs = 17.76 1 17.76 5.92 1 5.92
Walls on Slabs = 0 0 0.00 0 0 0.00
Beams = 9.94 2 19.87 0 2 0.00
Walls on Beams = 45.54 1 45.54 0 1 0.00
Columns = 2.88 2 5.76 0 2 0.00
Stub = 1.44 1 1.44 0 1 0.00

TOTAL UNFACTORED LOADS 93.79 10.02


Total is = 103.81

ULS FACTORS DEAD LIVE


CODE BS 1.4 1.6
SANS 1.2 1.5

TOTAL ULS LOADS


CODE = SANS Pick an option here
Therefore
LOAD DEAD = 112.548 LIVE = 15.032
= 127.580
Now Soil Pressure

Maximum Allowable Bearing Pressure = 200 kPa or kN/m2 it’s the same

Thus required area under SLS = Force/Pressure


= 103.81 / 200
= 0.5191 square metres

thus assuming a square base each side is = 0.720456 X 0.72046


= 0.73 X 0.73

112.38 10
79.96 17.2
192.34 27.2
259.34

You might also like