Syndey Street : South Block Loadings

Site Coordinates Easting 306373 Northing


Site altitude = 125 m

Wind:

Qb = 1.2 kN/m2 (to be calculated)

snow drift = 2 kN/m2 (to be calculated)

Roof dead load

single Ply membrane 0.1 kN/m2


rigid insulation 0.1 kN/m2
18mm Plyqwood decking 0.12 kN/m2
Timber truss/joists 0.3 kN/m2
100mm Mineral wool 0.2 kN/m2
12.5mm British gypsum 0.1 kN/m2
Ceiling and Services 0.35 kN/m2

Dead load = 1.27 kN/m2


Solar panel load = 0.5 kN/m2
Total Dead Load = 1.77 kN/m2
Roof Imposed load
imposed load for access = 1.5

Imposed load (snow) = 0.6 kN/m2

Imposed load (maintenance) = 2


Imposed load to be taken in calcs: = 0.6
Perimeter external Wall linear loads

Parapet height h= 1.3

timber stud wall wint = 0.5

facing block 100 mm @ 20


wext = 2

Total weigh of the walls 3.25


Surface Load to be applied to roof

Total dead load = 1.77 kN/m2

Total live load = 2 kN/m2

Load Distribution on Bearing Walls

Linear Load in
Roof Dead Load
load along grid line A = 6.55

load along grid line B = 8.32


load along grid line C = 8.32

load along grid line D = 6.55

load along grid line 1 = 1.77

load along grid line 2 = 5.13

load along grid line 3 = 5.13

load along grid line 4 = 1.77


668122 City: Livingston

Roof make up

culated)

as drift
assumed light roof (tbc by architect)
permanent

kN/m2 maintenance load: (accidental load)

kN/m2
kN/m2

kN/m2

kN/m3
kN/m2

kN/m
Linear Load in (kN/m)
ad Load Wall dead wall Roof Live load
3.25 7.40

9.40
9.40

3.25 7.40

(for 1m width) 3.25 2.00 (for 1m width)

5.80

5.80

(for 1m width) 3.25 2.00 (for 1m width)


Roof dimensions:

7400

B
2000

7400

19000
1 2 5800 3
19000