19F3701, bus communication reduced

Show All Profiles

Valid for software release


Model Software release start Software release stop
A40E Volvo V2007.4.0

The function triggers an alarm when reduced function at information bus SAE J1708 or control bus SAE J1939 (CAN2) is
detected.

Input signal
From Description Reaction to incorrect input signal
System message from ECU M3703, Bus communication failure No error assumed
(information bus SAE J1708)
System message from ECU M3702, bus communication failure
(control bus SAE J1939) (CAN 2)

Output signal
Description To
M3701, Alarm level, reduced bus 31C3701
communication

MO31 Warnings, 31C3701


Input signal Conditions Alarm level/Output signal
M3701, Alarm level, Error at SAE J1708 or SAE J1939 3 Alarm figure:
reduced bus (CAN2) detected during ten consecutive
communication checks

31F3801, orange central warning