11-4 Troubleshooting: Alarm Display Error Conditions Status When Error Occurs Cause Measures
11-4 Troubleshooting: Alarm Display Error Conditions Status When Error Occurs Cause Measures
· Wire correctly.
· The forward drive · Replace the limit sensor.
Occurs when the servo is prohibition (POT) input · Check whether the
Drive prohibition input turned ON. and reverse drive power supply for control
38
error Or, occurs during prohibition (NOT) input is input correctly.
operation. were both OFF at the · Check whether the setting for
same time. Drive Prohibition Input
Selection (Pn504) is correct.
Absolute encoder Occurs when the power · The voltage supplied to · Set up the absolute encoder.
40 system down error supply is turned ON. the absolute encoder is · Connect the battery
ABS Occurs during operation. low. power supply.