You are on page 1of 3

Workshop Manual Training Center

1305 / 1505 / 1605 / 1705 Mobile Revised: 08.2004

LUVD system

Q[%]

100

50

0
1 2

A1 A2

Q = f (A)
∆p1 = ∆p2
Nov 03; P Witt; BRM/VMK2; Atlas Terex

1 - Fine metering
2 - Spool stroke

• Commencement of movement and fine control range independent of pressure and flow rate
• The consumers do not influence one another

Page 6 of 32 Chapter 7
Control block
Training Center Workshop Manual
Revised: 08.2004 1305 / 1505 / 1605 / 1705 Mobile

Flow distribution

80 Consumer I
60 Qobjective = 80,0 l/min
Qactual = 61,5 l/min
40 ratio 0,77
20
t
Q

80
Consumer II
60 Qobjective = 50,0 l/min
Qactual = 38,5 l/min
40 ratio 0,77
20
t
Q

100
Pump
80 Qmax = 100,0 l/min
60
40
20 t
Nov. 03; P. Witt; BRM/VMK2; Atlas Terex

Chapter 7 Page 7 of 32
Control block
Workshop Manual Training Center
1305 / 1505 / 1605 / 1705 Mobile Revised: 08.2004

LUDV principle
(flow distribution independent of load pressure)

qV = f (.p, A)
F1 F2
F1 < F2
P1 < P2

Cover
QV1 A1 > A2
Q V2
∆ p1 = Pp - P1’
P1
∆ p2 = Pp - P2’
P2 p2 = P2’ = P1’
∆ p1 = ∆ p2 = ∆ p

∆ p = const.
∆p3
A1 und A2
P1'(P2') P2'
∆ p3 = P2 - P1
∆p1 ∆p2 qV1 = f (A1)
A1 A2 qV2 = f (A2)

qV1 A1
qV2 = A2

Nov 03; P Witt; BRM/VMK2; Atlas Terex

Page 8 of 32 Chapter 7