You are on page 1of 3

FUNCTIONAL DESCRIPTION OF REGULATORS

Regulator Code Control Curves Hydraulic Circuit


0000 Stepless Manual Displacement Control A
The pump is supplied without a regulator. The discharge
a
flow can be steplessly adjusted by manually turning
adjustment screws on the pump. This adjustment

Discharge flow Q
provision is a standard feature on all K3VG pumps
providing a means to limit the maximum and
minimum displacement.
Discharge pressure Pd

Dr B
Range of Flow Control 50-100%

A
10## Horsepower Control

Discharge flow Q
1N## Horsepower and Negative Flow Control
In response to a rise in delivery pressure, the swash
plate tilting angle is decreased, restricting the input a

torque. This regulator prevents excessive load against Discharge pressure Pd


the prime mover. By adding a pilot signal to the Pi port Pi
Discharge flow Q

the discharge flow can be infinitely adjusted within the


range of the pump. An increase in pilot signal will result
in a decrease in flow, hence the Negative control.
Pilot pressure Pi b
Range of Flow Control 100-15% Dr B
A
1P## Horsepower and Positive Flow Control
Discharge flow Q

This regulator combines the Horsepower Control with


Positive Flow Control. By adding a pilot signal to the Pi
a
port the discharge flow can be infinitely adjusted within
the range of the pump. An increase in pilot signal will Discharge pressure Pd

result in an increase in flow, hence the Positive control. Pi


Discharge flow Q

Pilot pressure Pi b
Range of Flow Control 2.5-100%
Dr B

1E## Horsepower and Electric Flow Control A1 A2


Discharge flow Q

This regulator combines the Horsepower Control with


Electric Flow Control. A proportional reducing valve is
added to the regulator so the discharge flow can be a1
infinitely adjusted within the range of the pump. An Discharge pressure Pd

increase in electric signal to the proportional reducing


Discharge flow Q

valve will result in an increase in flow. This regulator a2


40 bar
requires an amplifier (refer to page 9) to provide the
electric signal.
b
Electric (Current) Signal
Dr B1 B2
Range of Flow Control 2.5-100%

50## Horsepower and Pressure Cutoff A


Discharge flow Q

5N## Horsepower, Pressure Cutoff and


Negative Flow Control a
This regulator combines the Horsepower Control with
Pi
Pressure Cutoff Control. By adding a pilot signal to the Discharge pressure Pd

Pi port the discharge flow can be infinitely adjusted


Discharge flow Q

within the range of the pump. An increase in pilot signal


will result in a decrease in flow, hence the Negative
control.
Pilot pressure Pi
b
Dr B
Range of Flow Control 100-15%

6
FUNCTIONAL DESCRIPTION OF REGULATORS (continued)
Regulator Code Control Curves Hydraulic Circuit
5P## Horsepower, Pressure Cutoff and Positive Flow Control

Discharge flow Q
A
This regulator combines the Horsepower Control with Pressure
Cutoff Control. By adding a pilot signal to the Pi port the a
discharge flow can be infinitely adjusted within the range of
Discharge pressure Pd Pi
the pump. An increase in pilot signal will result in an increase
in flow, hence the Positive control.

Discharge flow Q
Pilot pressure Pi b
Range of Flow Control 2.5-100% Dr B

5E## Horsepower, Pressure Cutoff and Electric Flow Control A1 A 2

Discharge flow Q
This regulator combines the Horsepower Control with Pressure
Cutoff and Electric Flow Control. A proportional reducing a1
valve is added to the regulator so the discharge flow can be infi-
nitely adjusted within the range of the pump. An increase Discharge pressure Pd

in electric signal to the proportional reducing valve will result Discharge flow Q

in an increase in flow. This regulator requires an amplifier


(refer to page 9) to provide the electric signal. a2
40 bar

Electric (Current) Signal b


Range of Flow Control 2.5-100 % Dr B1 B2

5L## Horsepower and Load Sense Control


This regulator combines Horsepower Control and Load Sense A
Control.
a
Discharge flow Q

PL

Discharge pressure Pd

b
Dr B
Range of Flow Control 2.5-100%

6000 Pressure Cutoff Control


This regulator maintains a constant pressure regardless of the A
discharge flow. It is imperative that a safety relief valve is
installed in the circuit. a
Discharge flow Q

By connecting the Pc port to a remote pressure control, variable PC


pump pressure control can be achieved.
A subplate can be added to the regulator that will Discharge pressure Pd
accommodate a “DO3” proportional relief valve for variable b
Pressure Cutoff Control. Dr B

6L00 Load Sense Control


This regulator controls the pump displacement to match the flow A
requirement as a function of load pressure. In addition, there is a
Discharge flow Q

Pressure Cutoff Function incorporated into the regulator. a

PL

Discharge pressure Pd

b
Dr B
Range of Flow Control 2.5-100%

7
FUNCTIONAL DESCRIPTION OF REGULATORS (continued)
Regulator Code Control Curves Hydraulic Circuit
70## Horsepower and Pressure Cutoff
7N## Horsepower, Pressure Cutoff and

Discharge flow Q
Negative Flow Control (with Remote Pressure Cutoff Capability)
A
This regulator combines the Horsepower Control with Pressure
Cutoff Control. By adding a pilot signal to the Pi port the
a
discharge flow can be infinitely adjusted within the range of Discharge pressure Pd
the pump. An increase in pilot signal will result in a decrease Pi
in flow, hence the Negative control.
PC

Discharge flow Q
By connecting the Pc port to a remote pressure control, variable
pump pressure control can be achieved.
Discharge pressure Pd b
A subplate can be added to the regulator that will Dr B
accommodate a “DO3” proportional relief valve for variable Range of Flow Control 100-15%

Pressure Cutoff Control.

7P## Horsepower, Pressure Cutoff and Positive Flow Control


(with Remote Pressure Cutoff Capability)
This regulator combines the Horsepower Control with Pressure
Discharge flow Q

A
Cutoff Control. By adding a pilot signal to the Pi port the
discharge flow can be infinitely adjusted within the range of a
the pump. An increase in pilot signal will result in an increase
Discharge pressure Pd Pi
in flow, hence the Positive control.
PC
By connecting the Pc port to a remote pressure control, variable
Discharge flow Q

pump pressure control can be achieved.

A subplate can be added to the regulator that will b


accommodate a “DO3” proportional relief valve for variable Pilot pressure Pi Dr B
Pressure Cutoff Control. Range of Flow Control 2.5-100%

7E## Horsepower, Pressure Cutoff and Electric Flow Control


(with Remote Pressure Cutoff Capability)
This regulator combines the Horsepower Control with Pressure
Discharge flow Q

A1 A 2
Cutoff and Electric Flow Control. A proportional reducing
valve is added to the regulator so the discharge flow can be infi-
nitely adjusted within the range of the pump. An increase a1
Discharge pressure Pd
in electric signal to the proportional reducing valve will result
in an increase in flow. This regulator requires an amplifier
(refer to page 9) provide the electric signal. PC
Discharge flow Q

40 bar
a2
By connecting the Pc port to a remote pressure control, variable
pump pressure control can be achieved.
b
Electric (Current) Signal Dr B1 B2
A subplate can be added to the regulator that will
accommodate a “DO3” proportional relief valve for variable Range of Flow Control 2.5-100%
Pressure Cutoff Control.