You are on page 1of 79

MASTER CLOCK SYSTEM

TECHNICAL & USER MANUAL

TECHNICAL MANUAL A100K10807


Document Scope
This document describes the installation and programming of the
following products:

Product Description Item No.


Marine Master Clock 70000 3005050028
Marine Master Clock 70000L 3005050029
with Network Time Server

Revision Information
Rev. Date Author Description
V1.0 26.05.2013 SEN Final
V1.1 13.04.2013 SEN Updated 1717en13 to1717en16
Added doc.A100K11451 cable
V1.2 25.07.2013 SEN calculation. New rev. of cable
connection diagram A100K10836
V1.3 16.06.2015 SEN Masterclock; Protection changed
to IP-22, page 8
V1.4 25.11.2015 SEN Updated cable connection
diagram A100K10836
v1.5 12.05.2016 SEN Updated cable connection
diagram A100K10836
v1.6 24.08.2016 SEN Updated A100K10836 , changes
on term.block 6
V1.7 13.11.2018 HKL New manual versions 1717en19 -
1795en03 - 9539en14
V1.8 17.6.2019 HKL Power supply 50/60 Hz

Related Documentation
For further information, refer to the following documentation:
Doc.no. Documentation
A100K10836 Rev.02 Autocad dwg cable connection diagram
A100K10838 Autocad dwg dimension drawing 70000 &
70000L

Note: Autocad drawings and datasheets are available for all slave
clocks

A100K10807 v.1.8 Master Clock System Technical & User Manual


Contents

1. User Manual Marine Master Clock


Document:1717en19.doc
Date: 2017-12-22
51 Pages

2. Technical Manual Wired DCF Time Code-Clock


Document: 1785en03.doc
Date: 2009-11-04
5 pages

3. Option Ethernet Marine Master Clock


Document: 1795en03
Date: 2014-05-08
11 Pages

4. Technical Specification Marine Master Clock


Document: 9539en14
Date: 2018-08-15
5 Pages

5. Cable Connection
• Cable Connection Diagram
Document: A100K10836 (1 Page)
• Cable Calculation
Document: A100K11451 (1 Page)
• Dimensions Drawing
Document: A100K10838 (1 Page)

A100K10807 v.1.8 Master Clock System Technical & User Manual


Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 1 of 51

User Manual
Marine Master Clock

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 2 of 51

List of contents
TECHNICAL SPECIFICATIONS ............................................................................................................................... 4
GENERAL .............................................................................................................................................................................. 4
SLAVE CLOCK OUTPUT.......................................................................................................................................................... 4
RELAY OUTPUT ..................................................................................................................................................................... 4
ALARM OUTPUT .................................................................................................................................................................... 4
GENERAL DESCRIPTION........................................................................................................................................ 5

FRONT PANEL DESCRIPTION ............................................................................................................................... 5


KEYBOARD ........................................................................................................................................................................... 6
RELAY OUTPUT CONTROL SWITCHES ..................................................................................................................................... 6
STATUS MONITORING LED:S ................................................................................................................................................. 6
OUTPUT LINE MONITORING LED:S ........................................................................................................................................ 6
INSTALLATION ........................................................................................................................................................ 7

PROGRAMMING....................................................................................................................................................... 8
GENERAL .............................................................................................................................................................................. 8
RUNNING MODE .................................................................................................................................................................... 8
START UP PROCEDURE........................................................................................................................................................... 9
1. Start up questions (this page) ................................................................................................................................. 9
2. Output configuration / Setup (page 10) ................................................................................................................... 9
3. Enter time of Slave Clocks (page 12) ...................................................................................................................... 9
OUTPUT CONFIGURATION / SETUP ....................................................................................................................................... 10
SET UTC WHEN IN OPERATION ............................................................................................................................................ 11
SET LOCAL TIME WHEN IN OPERATION ............................................................................................................................... 11
SLAVE CLOCK ..................................................................................................................................................................... 12
TIME ZONE ADJUSTMENT..................................................................................................................................................... 13
ALARMS .............................................................................................................................................................................. 14
Example 1, display alarms ............................................................................................................................................. 14
Example 1, erase alarms ................................................................................................................................................ 15
Alarm list........................................................................................................................................................................ 16
WEEK PROGRAM & DATE PROGRAM .................................................................................................................................. 17
Concept description ....................................................................................................................................................... 17
Week Program, example 1 (New program) .................................................................................................................... 19
Week Program, example 2 (Change program) .............................................................................................................. 20
Week Program, example 3 (Erase program) ................................................................................................................. 21
Week Program, example 4 (Astronomical function) ...................................................................................................... 22
Week Program, example 5 (Block program).................................................................................................................. 23
Week Program, example 6 (Mask program) .................................................................................................................. 24
Date Program, example (New program)........................................................................................................................ 25
DISPLAY PROGRAM ............................................................................................................................................................. 26
TEMPORARY PROGRAM, EXAMPLE ...................................................................................................................................... 27
GROUP => PERIOD .............................................................................................................................................................. 28
SPEC.-FUNCTIONS ............................................................................................................................................................... 29
SPEC.-FUNCTIONS ............................................................................................................................................................... 29
Status.............................................................................................................................................................................. 30
Language ....................................................................................................................................................................... 32
Setup............................................................................................................................................................................... 33
Software version............................................................................................................................................................. 45

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 3 of 51

Default LT adjust ........................................................................................................................................................... 46


Display format ............................................................................................................................................................... 47
PROGRAMMING FORM ......................................................................................................................................... 48

FAULT TRACING .................................................................................................................................................... 49

ALARM OUTPUT .................................................................................................................................................... 50

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 4 of 51

Technical specifications
General
Crystal Frequency: 4,915200 MHz.
Accuracy: 0,1 sec./24 hours (at +20°C).
Microprocessor: HD6412394.
Connection voltage: 90 - 264V 50/60 Hz and. 24 V DC -5% +20 %.
Max ripple (24V DC): 0,7V RMS.
Power consumption: 65 W (max)
Ambient temperature: Between 0° C and +50°C.
Relative humidity: Max. 85% non-condensing.
IP rating: IP20
Weight: 5.6 kg.
CE-Approval, EMC: Emission acc. to EN61000-6-3, Immunity acc. to. EN61000-6-2.

Slave Clock output


Output 1, 2 and 3:
Impulse system: 1/1 minute, 1/2 minute, second, Time Code (TC)
Type of time: LT, UTC
Impulse length: Minute 0.1-9.9 sec.
Second 0.1-1 sec.
Output 4:
Impulse system: 2-wire: 1/1 minute, 1/2 minute, second, Time Code (TC).
3-wire for Forward/Reverse movement: 1/1-minute alt. 1/2-minut.
Type of time: LT, UTC
Impulse duration: Minute 0.1-9.9 sec.
Second 0.1-1 sec.
Maximum load / output: 2A (The output is equipped with short circuit protection that resets automatically.
Total load all outputs: 2.5A

Relay output
Relay outputs: 2 closing potential-free contacts.
Max. load/relay output: 24 V 6A.
Total load relay outputs: 12A
Program memory: 100 years (EEPROM)
Number of control functions: 800.

Alarm output
Number of outputs: 2 Changeover potential-free contacts.
Type of alarms
Output no. 1 (general alarm): Overload / short circuit, synchronisation alarm
Output no. 2 (power alarm): Power failure alarm

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 5 of 51

General description
Westerstrand Marine Master Clock is the ideal solution for distribution of both Local and UTC time on board
ships.
The Master Clock is equipped with several outputs and inputs for control of Slave Clocks as well as distribution
of time to computers and other equipment needing correct time. The four Slave Clock outputs can be
individually programmed for different types of clocks. External radio receivers / time synchronisation sources
can be connected when higher accuracy is needed.

For control and regulation of various energy consumers such as electrical striking plates, buzzers for pause
signalling etc, the master Clock has a built in yearly programmer with two relay outputs.

The Master Clock is equipped with 10 buttons and a 2 x 16 character LCD. To facilitate the change of time zone
two of the buttons are dedicated for this purpose. A light dimmer makes it possible to adjust the background
illumination to the surrounding light level.

The front mounted power switch is an all pole switch and controls both AC and DC power.
Position IN = Power ON.
Position OUT = Power OFF.

Front panel description

Status monitoring LED:s


Relay output control
Power switch
switches
Output line monitor
LED:s

1 ALARM

2 POWER
RADIO
LINK

LIGHT + ADV.

LIGHT - NO YES REV.

UTC

Control keyboard
Monitor Clock Monitor Clock
UTC Local Time

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 6 of 51

Keyboard
LIGHT+ Increase LED backlight level
LIGHT- Decrease LED backlight level
↑↓ Select function / Change and scroll
← Move left / Cancel / Leave programming mode
→ Move right
NO Decline
YES Accept / Enter programming mode
ADV. Advance Local Time
REV. Reverse Local Time

Relay output control switches


1 Always ON
0 Always OFF
A Automatic position, ON/OFF according to program.

Status monitoring LED:s


Alarm An alarm has occurred, for instance short circuit on one of the output lines.
Power Power is ON.
Radio Indicating signal coming from an external radio receiver.
Link Indicating Ethernet LAN connection. (option)

Output line monitoring LED:s

Output line no. 1

Output line no. 2

Output line no. 3

Output line no. 4

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 7 of 51

Installation
The Marine Master Clock is intended for stand, cabinet, wall or desk mounting.

1. Mount the Master Clock.


2. Make sure that all analogue slave clocks shows the same time, for instance 12.00.
4. Before connecting the slave clock lines, check the wires for short circuit, faulty connections etc.
5. Connect the slave clock lines.
6. Connect the signal line/lines (to relay contacts).
7. NOTE! For connection of signals etc., mixed voltages must not be used.
Therefore, choose either 230VAC or, for example 24VAC for connection to the relays.
8. Connect, if included, other accessories/options such as radio synchronisation, RS232 etc.
9. Connect the supply voltage and press the power switch.
10. Proceed to “Start up procedure” page 9.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 8 of 51

Programming
General
Using 6 buttons and a 2-row 16-character display carries out all programming.
Programming is self-instructive and to simplify the dialogue Yes/No questions are used.

Running mode
When the Time Base module is in operation it shows date
and time in the display. MON 26 SEP 2016
This is called running mode in this documentation. U10:11:35 L12:11

MON 26 SEP 2016


U10:11:35 L12:11

SET UTC

SET LT
1- Select function ↑↓
SLAVE CLOCK
2- Enter programming mode YES
ALARMS
3- Move sideways ←→

4- Change/scroll ↑↓ WEEK PROGRAM

5- Accept YES DATE PROGRAM

6- Cancel / Leave prog. mode ← DISPLAY PROGRAM

TEMPORARY PROGR.

GROUP  PERIODE

SPEC.-FUNCTIONS

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 9 of 51

Start up procedure

1. Start up questions (this page)

2. Output configuration / Setup (page 10)

3. Enter time of Slave Clocks (page 12)

STARTING
When the Master Clock is connected for the first time correct/requested
LANGUAGE language has to be entered. Press NO until requested
ENGLISH? language occurs in the display e.g. English. Accept with YES.

Set, by using the arrows, the right UTC.


SET UTC Time format: Year, month, date, hour, minute, second.
160926 10:11:00 Set the time a minute in advance.
Wait for the right time and synchronise using YES.

Set, by using the arrows, the right Local Time.


SET LT Time format: Year, month, date, hour, minute, second.
160926 12:11:00 Set the time a minute in advance.
Wait for the right time and synchronise using YES.

MON 26 SEP 2016 The Master Clock is now in running mode.


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 10 of 51

Output configuration / Setup


Each output can be individually configured regarding different parameters. The setup is done from the special
function Setup. If the default setup is used no configuration is needed.

Default setup:

Slave Clock output no. 1 Impulse system: 1/1 minute


Type of time: UTC
Impulse length: 2 sec.

Slave Clock output no. 2 Impulse system: -----------


Type of time:
Impulse length:

Slave Clock output no. 3 Impulse system: -----------


Type of time:
Impulse length:

Slave Clock output no. 4 Impulse system: 3-wire for Forward/Reverse, 1/1-minute.
Type of time: Local Time
Impulse length: 2 sec.

Synchronisation source
NMEA RS485 (NMEA 0183ZDA Time string)

RS232 output
NMSE (NMEA 0183ZDA Time string)

RS485 output
NMSE (NMEA 0183ZDA Time string)

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 11 of 51

Set UTC when in operation

MON 26 SEP 2016 Select function using ↓.


U10:11:35 L12:11

SET UTC Enter the programming mode with YES.

Set, by using the arrows, the right UTC.


SET UTC Time format: Year, month, date, hour, minute, second.
1609266 10:11:00 Set the time a minute in advance.
Wait for the right time and synchronise using YES.

SET UTC Leave programming mode by pressing ← several times.

MON 26 SEP 2016 The master clock is now back in running mode.
U10:11:00 L12:11

Set Local Time when in operation

Remark: To do normal Time Zone adjustments use the buttons, ADV and REV.

MON 26 SEP 2016 Select function using ↓.


U10:11:35 L12:11

SET LT Enter the programming mode with YES.

Set, by using the arrows, the right Local Time.


SET LT Time format: Year, month, date, hour, minute, second.
160926 12:11:00 Set the time a minute in advance.
Wait for the right time and synchronise using YES.

SET LT Leave programming mode by pressing ← several times.

MON 26 SEP 2016 The master clock is now back in running mode.
U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 12 of 51

Slave Clock

MON 26 SEP 2016 Select function using ↓.


U10:11:35 L12:11

SLAVE CLOCK Enter the programming mode with YES.

IMPULSE OUTPUT 1 Select output using ↑↓. Accept with YES.

IMPULSE OUTPUT 1 = 09.07? (Example)


IMPULSE OUTPUT 1 If the slave clocks connected to impulse output 1 shows 09:07 answer YES,
= 09:07 OFF if not, set the time shown by the slave clocks.

IMPULSE OUTPUT 1
= 09:07 OFF Turn ON impulse output 1 by using ↑↓.

IMPULSE OUTPUT 1 Accept with YES


= 09:07 ON

SLAVE CLOCK Leave programming mode by pressing ← several times.

MON 26 SEP 2016 The master clock is now back in running mode.
U10:11:35 L12:11

NOTE! If a slave clock runs out by a minute, its cabling must be pole changed and
the slave clock to be corrected manually.

NOTE! If the time of the slave clocks is ahead of correct/present time the Master Clock
will wait until correct time corresponds with the slave clocks.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 13 of 51

Time zone adjustment

To change Local Time zone two buttons are used. The buttons are named ADV and REV.
To advance the Local Time slave clocks to a new time zone press button ADV.

Example:

MON 26 SEP 2016


U10:11:35 L12:11 Press button ADV.

LOCAL TIME ADJ. Use the default value or change by pressing ADV.
60m ? Accept with YES.

LOCAL TIME ADJ. ! The Local Time slave clocks will now advance 60 minutes.

MON 26 SEP 2016 When the correction is finished the display is automatically returned to
running mode.
U10:11:35 L13:11

To reverse the Local Time slave clocks to a new time zone press button REV.
Example:

MON 26 SEP 2016


U10:11:35 L12:11 Press button REV.

LOCAL TIME ADJ. Use the default value or change by pressing REV.
- 60m ? Accept with YES.

LOCAL TIME ADJ. ! The Local Time slave clocks will now be adjusted as below:
1 Min forward clock’s stop 60 min
0,5 Min F/B clock’s: Reverse 60 Min
TC Clock’s: 11 hours forward
MON 26 SEP 2016 When the correction is finished the display is automatically returned to
U10:11:35 L11:11 running mode.

Remark: To interrupt a time zone adjustment in progress press button ← and YES.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 14 of 51

Alarms

This function is used to display and erase the different alarms in the master clock.

ALARMS- DISPLAY To show the alarms

To erase the alarms


ALARMS- ERASE

Example 1, display alarms

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:35 L12:11

ALARMS Accept with YES.

ALARMS- DISPLAY Press NO until the wished function is shown.


Accept with YES.

The alarm is displayed.


09AUG 15:52 Press ↑↓ to see next alarm.
NO RADIO 30
Return to running mode press ←.

ALARMS- DISPLAY ←.

ALARMS ←.

MON 26 SEP 2016


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 15 of 51

Example 1, erase alarms

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:35 L12:11

ALARMS Accept with YES.

ALARMS- ERASE Press NO until the wished function is shown.


Accept with YES.

The alarm is displayed.


09 AUG 15:52 Press YES to erase the alarm.
NO RADIO

ERASE? Accept with YES.

ALARMS- ERASE Return to running mode press ←.

ALARMS ←.

MON 26 SEP 2016


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 16 of 51

Alarm list
The following alarms are available

Type of alarm Indication Reason for alarm Action


Alarm code

NO RADIO 30 Red alarm LED lit. The Master Clock has Check the external
General alarm relay activated. not been synchronised synchronisation source. If
within the alarm limit. no external source is used
inactivate the alarm. See
special function/ setup
sync. source page 36.
UF LOW 52 Red alarm LED lit. Impulse voltage below Remove connected clocks
General alarm relay activated. alarm limit. and clear the alarm. If OK,
check clocks and wiring.
SHORT CIRCUIT 53 Red alarm LED lit. Short circuit on impulse Remove short circuit.
Common alarm relay activated. amplifier. If OK, clear the alarm.
CURRENT LOW 61 Red alarm LED lit. Impulse current on Check output connections.
General alarm relay activated. output no. 1 is below If OK, clear the alarm.
alarm limit.
CURRENT LOW 62 Red alarm LED lit. Impulse current on Check output connections.
General alarm relay activated. output no. 2 is below If OK, clear the alarm.
alarm limit.
CURRENT LOW 63 Red alarm LED lit. Impulse current on Check output connections.
General alarm relay activated. output no. 3 is below If OK, clear the alarm.
alarm limit.
CURRENT LOW 64 Red alarm LED lit. Impulse current on Check output connections.
General alarm relay activated. output no. 4 is below If OK, clear the alarm.
alarm limit.
CURRENT HIGH 71 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 1 is above If OK, clear the alarm.
alarm limit.
CURRENT HIGH 72 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 2 is above If OK, clear the alarm.
alarm limit.
CURRENT HIGH 73 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 3 is above If OK, clear the alarm.
alarm limit.
CURRENT HIGH 74 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 4 is above If OK, clear the alarm.
alarm limit.
CURRENT HIGH 75 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 4 is above If OK, clear the alarm.
(Remark: Alarm 75 is only used alarm limit.
in a 3-wire Forward/Reverse
system.)

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 17 of 51

Week Program & Date Program


Using these two functions, programming of the outputs is made.

Concept description
Program A "program" refers to programming an output to a certain time. The word program
represents a single time event and several programs are defined as a group of
programs.
For example: output 2 switches on every working day (Monday-Friday) at 8.00.

Week program A week program is a program, which is repeated every week. You can for each
program choose for which days of the week it shall be valid:
Individual or block programming.
M = Monday
T = Tuesday
W = Wednesday
T = Thursday
F = Friday
S = Saturday
S = Sunday

Date program A date program is a program, which is valid for a specific date.

Group A group of programs, signal events.

Type of signals There are some different kinds of signals, depending on how the relay output is to
be used.

ON/OFF Is used when a longer lasting switching ON is required, e.g. for controlling fans,
door locks, lighting etc.

01s Is used when a short pulse is required, e.g. for bells/buzzers.


Pulse duration selectable from 1-99 seconds.

Astr. Astr. (Twilight) is a function which closes/opens a predestined relay at sunrise


resp. sunset. Which day and month of the year it is, and where the Time Central
programmer is located geographically, define the time of the sunrise resp. sunset.
The sunrise resp. sunset are calculated in the software of the Y8 module.
The geographic position of the Time Central is entered at starting up.
A map indicating latitude (°north) and longitude (°east) is enclosed.

Mask A program that is repeated f. ex every hour is easily entered by the use of mask
program.
XX.15.00 ; the program is repeated every hour att minute 15.
08.XX.00 ; the program is repeated every minute between 08.00 and 09.00.
XX.XX.00 ; The program is repeated every minute.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 18 of 51

To simplify programming 3 sub menus are used:

WEEK PROGRAM
NEW GROUP A To enter new programs.

WEEK PROGRAM
ERASE GROUP A To erase a separate existing program.

WEEK PROGRAM
To change existing programs.
CHANGE GROUP A

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 19 of 51

Week Program, example 1 (New program)

Example: Outputs No. 2 shall switch on Monday – Friday at 09.00 and off at 17.00.

MON 26 SEP 2016 Select function using ↑↓.


U10:11:00 L12:11

WEEK PROGRAM Enter programming mode using YES.

WEEK PROGRAM Select new program using YES.


NEW GROUP A

WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
NEW GROUP A

OUTPUT 2 ON Select output using ↑↓. Move to the right using →.


------- 08:00:00

OUTPUT 2 ON
------- 08:00:00 State type of signal using ↑↓.

OUTPUT 2 ON
MTWTF-- 08:00:00 State the days the program shall function using ↑↓.
Move to the right using →.

State the time of the program using ↑↓.


OUTPUT 2 ON Move to the right using →.
MTWTF-- 09:00:00 Accept using YES.
If the program is approved the text “Program saved” is displayed quickly.

OUTPUT 2 OFF Continue with programming OFF for the same output or leave
MTWTF-- 17:00:00 programming by pressing ← several times.

WEEK PROGRAM

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 20 of 51

Week Program, example 2 (Change program)

Example: A signal on output 1, Monday – Friday at 08.00, shall be changed to 08.15. Signal length is 5 seconds.

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:00 L12:11

WEEK PROGRAM Enter programming mode using YES.

WEEK PROGRAM Select change program using YES.


CHANGE GROUP A

WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
CHANGE GROUP A

OUTPUT 2 05S
Select output using ↑↓. Move to the right using →.
MTWTF-- 08:00:00

OUTPUT 2 05S
MTWTF-- 08:00:00 Step forward to the program, which is to be changed using NO and YES.

OUTPUT 2 05S Change the time to 09.15 using the arrows.


MTWTF-- 08:15:00 Accept using YES.

WEEK PROGRAM
Leave the programming by pressing ← several times.

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 21 of 51

Week Program, example 3 (Erase program)

Example: A signal on output 1, Fridays at 16.30 shall be deleted. Signal length is 5 seconds.

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:00 L12:11

WEEK PROGRAM Enter programming mode using YES.

WEEK PROGRAM Select erase program using YES.


ERASE GROUP A

WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
ERASE GROUP A

OUTPUT 1 ON Select output using ↑↓. Move to the right using →.


MTWTF-- 09:00:00

OUTPUT 1 05S Step forward to the program that is to be erased using NO and YES.
----F-- 16:30:00 Accept using YES.

WEEK PROGRAM Leave the programming by pressing ← several times.

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 22 of 51

Week Program, example 4 (Astronomical function)

Example: Output No. 1 shall switch ON all sunset All days and switch OFF at sunrise.

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:00 L12:11

WEEK PROGRAM Enter programming mode using YES.

WEEK PROGRAM Select new program using YES.


NEW GROUP A

WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
NEW GROUP A

OUTPUT 2 ON Select output using ↑↓. Move to the right using →.


MTWTF-- 08:00:00

OUTPUT 2 ASTR
MTWTF-- State type of signal using ↑↓.

OUTPUT 2 ASTR State the days the program shall function using ↑↓.
MTWTF-- Accept using YES.
If the program is approved the text “Program saved” is displayed quickly.

WEEK PROGRAM Leave the programming by pressing ← several times.

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 23 of 51

Week Program, example 5 (Block program)

Example: Outputs No. 2 shall switch on Monday, Wednesday and Friday at 09.00.

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:00 L12:11

WEEK PROGRAM Enter programming mode using YES.

WEEK PROGRAM Select new program using YES.


NEW GROUP A

WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
NEW GROUP A

OUTPUT 2 ON Select output using ↑↓. Move to the right using →.


------- 08:00:00

OUTPUT 2 ON
------- 08:00:00 State type of signal using ↑↓.

OUTPUT 2 ON
M-W-F-- 08:00:00 State the days the program shall function using ↑↓.
Move to the right using →.

State the time of the program using ↑↓.


OUTPUT 2 ON Move to the right using →.
M-W-F-- 09:00:00 Accept using YES.
If the program is approved the text “Program saved” is displayed quickly.

OUTPUT 2 OFF Continue with programming OFF for the same output or leave
M-W-F-- 09:00:00 programming by pressing ← several times

WEEK PROGRAM

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 24 of 51

Week Program, example 6 (Mask program)

Example: Outputs No. 2 shall switch on for 5 seconds every hour at minute 15, all days in the week.

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:00 L12:11

WEEK PROGRAM Enter programming mode using YES.

WEEK PROGRAM Select new program using YES.


NEW GROUP A

WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
NEW GROUP A

OUTPUT 2 ON Select output using ↑↓. Move to the right using →.


------- 08:00:00

OUTPUT 2 05S State type of signal using ↑↓.


------- 08:00:00 05S = Pulse with 5 seconds length.

OUTPUT 2 05S State the days the program shall function using ↑↓.
MTWTFSS 08:00:00 Move to the right using →.

State the time of the program using ↑↓. ** = every hour.


OUTPUT 2 05S Move to the right using →.
MTWTFSS **:15:00 Accept using YES.
If the program is approved the text “Program saved” is displayed quickly.

WEEK PROGRAM Leave programming by pressing ← several times.

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 25 of 51

Date Program, example (New program)

Example: Outputs No. 1 shall switch on the 1st of August at 12.00.

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:00 L12:11

DATE PROGRAM Enter programming mode using YES.

DATE PROGRAM Select new program using YES.


NEW

OUTPUT 1 ON Select output using ↑↓. Move to the right using →.


AUG 01 08:00:00

OUTPUT 1 ON
AUG 01 08:00:00 State type of signal using ↑↓.

OUTPUT 1 ON
AUG 01 08:00:00 State the date the program shall function using ↑↓.
Move to the right using →.

State the time of the program using ↑↓.


OUTPUT 1 ON Move to the right using →.
AUG 01 12:00:00 Accept using YES.
If the program is approved the text “Program saved” is displayed quickly.

OUTPUT 1 OFF Continue with programming OFF for the same output or leave
AUG 01 12:00:00 programming by pressing ← several times.

DATE PROGRAM

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 26 of 51

Display Program

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:00 L12:11

DISPLAY PROGRAM Enter display program using YES.

DISPLAY PROGRAM Select program group using ↑↓, accept with YES.
GROUP A

GROUP A Select output to be displayed using ↑↓, accept with YES.


OUTPUT ALL

OUTPUT 2 ON Step forwards alt. Backwards using ↑↓.


MTWTF-- 08:00:00

DISPLAY PROGRAM Leave the function display program by pressing ← several times.

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 27 of 51

Temporary Program, example

Example: Outputs No. 2 shall switch on immediately 15.35.00 and turn off according to normal week program.
The temporary program will automatically be erased when the event has been effected.

MON 26 SEP 2016 Select function using ↑↓ .


U10:11:00 L12:11

TEMPORARY PROGR. Enter programming mode using YES.

OUTPUT 2 ON Select output using ↑↓. Move to the right using →.


15:35:00

OUTPUT 2 ON State type of signal using ↑↓.


15:35:00 Accept using YES

OUTPUT 2 ON Accept using YES or change the time of the program using ↑↓.
15:35:00

TEMPORARY PROGR. Leave the programming by pressing ″ several times.

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 28 of 51

Group => Period

Each program group can be associated to one or several time periods. A time period can consist of one or
several dates. Maximum 99 time periods can be used. Program group A is as default associated to a time period
covering the complete year, 1/1-31/12.

Example:
A school has one group of programs that are used during the school season and another used during school
holidays. School season = Group A, School holidays = Group B.

The school holidays are at the following dates: 1/5, 10/6-15/8, 23/9 and so on...

MON 26 SEP 2016


U10:11:00 L12:11 Select function using ↑↓ .

GROUP => PERIOD Enter programming mode using YES.

GROUP B
1:____ - _____ Select group of programs using ↑↓, accept using YES.

GROUP B State the date when the period shall begin.


1:MAY01 - _____ Move to the right using →.

GROUP B
State the date when the period shall end.
1:MAY01 – MAY01 Accept with Yes.

GROUP B Continue with next time period.


2:____ - _____

GROUP B
2:JUN07 – _____

GROUP B Accept with YES.


2:JUN07 – AUG15

GROUP => PERIOD


Continue with next time period or leave
programming by pressing ← several times.

MON 26 SEP 2016


U10:11:00 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 29 of 51

Spec.-Functions

The special functions contain functions used during setup and configuration of the Master Clock.
If the default settings are used no configuration is needed.

MON 26 SEP 2016 Select function using ↓ .


U10:11:35 L12:11

SPEC.-FUNCTIONS Accept with YES.

SPEC.-FUNCTIONS Press NO until wished function is shown.


STATUS Accept with YES.

STATUS Show status information of the different output/ input in the Master Clock.

LANGUAGE
Language selection.

Setup / configuration of the different impulse system, type of


SETUP synchronisation etc.

DISPLAY FORMAT
Display format in running mode.

SOFTWARE VERSION Present software version.

DEFAULT LT ADJ. Default value used when pressing button ADV or REV.

SPEC.-FUNCTIONS Return to running mode press ←.


STATUS

MON 26 SEP 2016


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 30 of 51

Status

With this function each input/output status can be checked.

Example:
Check the status of the synchronisation source receiver.

MON 26 SEP 2016 Select function using ↓ .


U10:11:35 L12:11

Accept with YES.


SPEC.-FUNCTIONS Press NO until wished function is shown.

SPEC.-FUNCTIONS Accept with YES.


STATUS

STATUS Press NO until wished input/output is shown.


SYNC.SOURCE Accept with YES.

NMEA RS485 60% The Master Clock has accepted 60% of the synchronisation messages.
14OCT 19:59:00 Last reception was 14/10 19:59:00.

STATUS Return to running mode press ←.


SYNC.SOURCE

SPEC.-FUNCTIONS ←
STATUS

SPEC.-FUNCTIONS ←

MON 26 SEP 2016


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 31 of 51

Status sync. source

Type of synchronisation % of accepted messages

NMEA RS485 60%


01 MAY 12:00:00

Last reception was 01MAY12:00:00*.

*Remark: For W-GPS the marked position always shows the actual second. This information is updated every
other second.

Status impulse output

Impulse current

IL=0.5
12:00 UF=26 V

Slave Clock time Impulse voltage

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 32 of 51

Language

With this function the language be selected.

Example:

MON 26 SEP 2016 Select function using ↓ .


U10:11:35 L12:11

Accept with YES.


SPEC.-FUNCTIONS Press NO until wished function is shown.

SPEC.-FUNCTIONS Accept with YES.


LANGUAGE

LANGUAGE Select, by using the arrows, the wished language.


ENGLISH? Accept with YES.

SPEC.-FUNCTIONS Return to running mode press ←.


LANGUAGE

MON 26 SEP 2016


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 33 of 51

Setup

With this function the different output and input can be configured. If the default setup is used no configuration
is needed.

Example:
Set the alarm limit for synchronisation source alarm to 1 hour. (Default setting is 12 hours.)

MON 26 SEP 2016 Select function using ↓ .


U10:11:35 L12:11

Accept with YES.


SPEC.-FUNCTIONS Press NO until wished function is shown.

SPEC.-FUNCTIONS Accept with YES.


SETUP

SETUP Press NO until wished input/output is shown.


SYNC SOURCE Accept with YES.

NMEA RS485 Set, by using the arrows, the alarm limit to 1 hour (01h).
AL.LIMIT --h -- m

NMEA RS485 Accept with YES


AL.LIMIT 01h 00 m

SETUP Return to running mode press ←.


SYNC SOURCE

SPEC.-FUNCTIONS ←
SETUP

SPEC.-FUNCTIONS ←

MON 26 SEP 2016


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 34 of 51

Setup sync. source

Below is a description of the different configuration parameters available in the setup menu for sync. source.
Please remark that if default settings are used no configuration is needed.

Type of synchronisation

NMEA RS485
AL. LIMIT --h--m

Alarm limit

Type of synchronisation
State type of external synchronisation. The following time sources can be selected:

NMEA RS485 (default) Synchronisation using RS485 input and NMEA ZDA protocol.
NMEA RS232 Synchronisation using RS232 input and NMEA ZDA protocol.
W-GPS Radio synchronisation GPS type Westerstrand.
DCF77 Radio synchronisation DCF77.
TC Time code type hard wired DC
-------- No external synchronisation

Alarm limit
The configuration parameter Alarm limit specifies the time delay before the radio alarm is activated. Default
setting is that the radio alarm is inactivated, AL.LIMIT --h--m.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 35 of 51

Setup impulse output

Below is a description of the different configuration parameters available in the setup menu for impulse output.
Please remark that if default settings are used no configuration is needed.

Impulse type

Type of impulse Type of time

1/1MIN 24H LT
2.0s?

Impulse length

Type of impulse
Selection of impulse type. The following types are available.

1/1M-24H : Polarised 1/1-minute impulse with 24 hours resetting


1/1M-12H : Polarised 1/1-minute impulse with 12 hours resetting.
1/2M-24H : Polarised 1/2-minute impulse with 24 hours resetting
1/2M-12H : Polarised 1/2-minute impulse with 12 hours resetting.
SEC-12H : Polarised Second impulses with 12 hours resetting.
SEC-60S : Polarised Second impulses with 60 seconds resetting.
1/2-SEC : Polarised Second impulses with 60 seconds resetting.
TCmarine : Time Code marine
TC-ext : Time Code marine for TC-Clocks diameter 600-900 mm.
FW/RW : 3-wire for Forward/Reverse, 1/1-minute.
FW/RW1/2 : 3-wire for Forward/Reverse, 1/2-minute.
1/1M-SS : Polarised 1/1-minute impulse for analogue clocks with sweeping second hand.
(2 seconds pulse length in normal mode and 0.5 seconds during correction)
1/2M-12B : Clock signal to Telegraph Logger
----------- : No impulse system.

Type of time
LT = Local Time.
UTC = Universal Time Coordinated.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 36 of 51

Impulse length
Configuration of impulse length.

1/1 and 1/2 -minute impulse: 0.1s – 9.9 s.


Second impulses: 0.1 – 1.0 s.

Alarm limits

Impulse current low limit Impulse current high limit

IL=0.0 - 2.0A
UF= -- V

Impulse feedback
voltage limit

Impulse current low limit


Alarm limit for low current (minimum load). The minimum load can be set from 0A up to 2.0A.

Impulse current high limit


Alarm limit for high current (maximum load). The maximum load can be set from 0A up to 2.0A.

Impulse feedback voltage limit


Alarm limit for feedback impulse voltage.
-- : No limit (default).
01 - 99 : Limit in volts, V.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 37 of 51

Setup RS232 and RS485/422 output / input

Below is a description of the different configuration parameters available in the setup menu for the RS232 and
RS485 input/ output.
Please remark that if default settings are used no configuration is needed. The RS485/422 input protocol is
always fixed to NMEA ZDA Time string and cannot be changed.

Type of time
Type of protocol

NMSE LT
4800 8N1

Baud rate Data format

Type of protocol
Name of the transmission / reception protocol used in the module. The following protocols are available.

NMEA output from Master Clock


NMMI: NMEA 0183, ZDA Time string, minute update, without hundreds of seconds
NMSE: NMEA 0183, ZDA Time string, second update, without hundreds of seconds
NMMC: NMEA 0183, ZDA Time string, minute update, with hundreds of seconds
NMSC: NMEA 0183, ZDA Time string, second update, with hundreds of seconds

NMin NMEA 0183, ZDA Time string, (input to Master Clock)

Other protocols
1: General 2-way-communication protocol.
2, 3, 5, 7, 16 etc.: Automatic time message protocols.

Type of time
Type of time received or transmitted.
LT = Local Time.
UTC = Universal Time Coordinated.

Baudrate
Available speeds: 300, 600, 1200, 2400, 4800, 9600 baud.

Data format
Data format of message received or transmitted.
No. of data bits, 7 or 8.
Type of parity, none, odd or even.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 38 of 51

No. of stop bits, 1 or 2.

Available formats:
7N1, 7N2, 7O1, 7O2, 7E1, 7E2, 8N1, 8N2, 8O1, 8O2, 8E1, 8E2,

Protocol description

ZDA - Time & Date - UTC, Day, Month, Year and Local Time Zone
1 2 3 4 5 6 7
| | | | | | |
$--ZDA,hhmmss.ss,xx,xx,xxxx,xx,xx*hh<CR><LF>

Field Number:
1) Universal Time Coordinated (UTC)
2) Day, 01 to 31
3) Month, 01 to 12
4) Year
5) Local zone description, 00 to +- 13 hours
6) Local zone minutes description, same sign as local hours
7) Checksum

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 39 of 51

Protocol 2

The message has length 20 bytes according to:

STX F G W 20 YY MM DD HH MM SS ETX BCC

F - Flag bits
7 =0
6 =1
5 =0
4 =0 Winter time, =1 summer time
3 =1 Synced from Radio source, e.g. DCF77
2 =1 Synched from timeserver

1 0 Type of time
OFF OFF UTC
OFF ON LOC
ON OFF NOR

Example:
Assume wintertime time, synched from radio source, synchronized from timeserver, local time:
Bits 6, 3, 2 and 0 are set: 0100 1101 = 4Dh = 'M'

G - UTC offset during wintertime from letter 'P' in 1/2 hour steps.
Example:
Germany 2 x 1/2 = 1 hour, so 'P'+2 = 'R'

W Weekday '1' Monday .. '7' Sunday


YY Year '00'..'99'
MM Month '01'..'12'
DD Day of month '01'..'31'
HH Hour '00'..'23'
MM Minute '00'..'59'
SS Second '00'..'59'
ETX 03h
BCC Exclusive or of bytes F..ETX

The message is transmitted each second

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 40 of 51

Protocol 3
At second 56 this message will be transmitted:

HH:MM:00 SP DD/MN/YY SP NNN SP W CR LF (25 bytes)

HH = Hour ‘00’ – ‘23’.


: = 3AH
MM = Minute ’00’ – ‘59’.
SP = Blank 20H.
DD = Date ’01’ – ‘31’.
/ = 2FH
MN = Month ‘01’ – ‘12’.
YY = Year ‘00’ – ‘99’.
NNN = Daynumber ‘001’ – ‘365’ (3 bytes).
W = Weekday ‘1’ – ‘7’.
CR = 0DH.
LF = 0AH.

At second 60 (0) a synchronisation sign SUB (1AH) is transmitted.

Remark: The message transmitted at second 56 is next minute.


Example:
At 09:07:56 is a message transmitted. The time included in this message will be 09:08:00.

Protocol 5
T:YY:MN:DD:WW:HH:MM:SS CR LF (24 bytes)

T = T
: = 3AH
YY = Year 00....99
MN = Month 01....12
DD = Day 01....31
WW = Day of week 01....07
HH = Hour 00....23
mm = Minutes 00....59
ss = Seconds 00....59
CR = Carrige return 0Dh.
LF = Line feed 0Ah.

The time message is sent out each minute or each second.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 41 of 51

Protocol 7

STX WW VV YYYY MN DD HH MM SS F G BCC ETX (24 bytes)

STX = 02h (1 byte).

WW = Week number '01'-'53'


VV = Weekday '01'-'07'
YYYY = Year '2003-2099'
MN = Month '01'-'12'
DD = Day '01'-'31'
HH = Hour '00'-'23'
MM = Minute '00'-'59'
SS = Second '00'-'59'

F = '0' Winter-time.
= '1' Summer-time.

G = Offset to UTC for winter-time according to (1 byte):


',' (2Ch) -2 hours, '.' (2Eh) -1 hour, '0' (30h) 0 hour.

BCC = Checksum; Exclusive OR of bytes WW..F G in hexadecimal ascii


format (2 bytes). Byte STX is NOT included!.

ETX = 03h (1 byte).

This message is sent out each second.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 42 of 51

Protocol 16*

STC HH MM SS DD MO MO YY HL HL ML ML ECT

Code description Hex value


STC Start Transmission Character 02
H Ten UTC hours 30-32
H Unit UTC hours 30-39
M Ten UTC minutes 30-35
M Unit UTC minutes 30-39
S Ten UTC seconds 30-35
S Unit UTC seconds 30-39
D Ten date UTC 30-33
D Unit date UTC 30-39
MO Ten month UTC 30-31
MO Unit month UTC 30-39
Y Ten year UTC 30-39
Y Unit year UTC 30-39
HL Ten LT hours 30-32
HL Unit LT hours 30-39
ML Ten LT minutes 30-35
ML Unit LT minutes 30-39
ECT End transmission character 03

* Protocol 16M = Message transmitted each minute.


* Protocol 16S = Message transmitted each second.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 43 of 51

Setup special pulse

Relay output no. 2 can be dedicated to send out a special pulse. When this function is enabled the relay is
activated every day for 5 seconds at 02.00 UTC.

Use the procedure below to enable the special pulse.

MON 26 SEP 2016 Select function using ↓ .


U10:11:35 L12:11

Accept with YES.


SPEC.-FUNCTIONS Press NO until wished function is shown.

SPEC.-FUNCTIONS Accept with YES.


SETUP

SETUP Press NO until wished input/output is shown.


SPECIAL PULSE Accept with YES.

SPECIAL PULSE Change to using ↑↓.


NO ?

SPECIAL PULSE Accept with YES


YES ?

SETUP Return to running mode press ←.


SPECIAL PULSE

SPEC.-FUNCTIONS ←
SETUP

SPEC.-FUNCTIONS ←

MON 26 SEP 2016


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 44 of 51

Setup NMEA LT

This function is valid only if the Master Clock is synchronised from an external NMEA source. Special function
sync. source must be set to NMEA RS485 or NMEA RS232.
With this function it can be selected if the Master Clock should use the Local Time (LT) information included in
the NMEA time message. The Master Clocks LT will be set to the nearest time with respect to the default value
entered in the special function DEFAULT LT ADJ.

Example:
DEFAULT LT ADJ is set to 20 minutes. Local Time is 15:30.

1. Received LT is changed 5 minutes to 15:35, which is closer to 15:30 than 15:50;


Master Clock LT will stay on 15:30.

2. Received LT is changed 10 minutes to 15:40, which is in the middle of 15:30 and 15:50;
Master Clock LT will stay on 15:30.

3. Received LT is changed 15 minutes to 15:45, which is closer to 15:50 than 15:30;


Master Clock LT will change 20 minutes to 15:50.

Default setting is NO, which means that the Local Time information is not used.

Use the procedure below to change the setting.

MON 26 SEP 2016


Select function using ↓ .
U10:11:35 L12:11

SPEC.-FUNCTIONS Accept with YES.

SPEC.-FUNCTIONS Press NO until wished function is shown.


SETUP Accept with YES.

Press NO until wished input/output is shown.


SETUP
Accept with YES.
NMEA LT

NMEA LT Change to using ↑↓.


NO ?

NMEA LT
YES ? Accept with YES

SETUP
NMEA LT
Return to running mode press ←.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 45 of 51

SPEC.-FUNCTIONS
SETUP ←

SPEC.-FUNCTIONS

MON 26 SEP 2016
U10:11:35 L12:11

Software version

This function shows the software version for the Time Base module.

MON 26 SEP 2016 Select function using ↓ .


U10:11:35 L12:11

Accept with YES.


SPEC.-FUNCTIONS Press NO until wished function is shown.

SPEC.-FUNCTIONS Accept with YES.


SOFTWARE VERSION

MMC-A127 The software version is MMC-A127.


11m 11m = Uptime for this Master Clock.

SPEC.-FUNCTIONS Return to running mode press ←.


SOFTWARE VERSION

SPEC.-FUNCTIONS ←

MON 26 SEP 2016


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 46 of 51

Default LT adjust

This function is used to enter the default value used when pressing button ADV or REV.

Example:
Change default LT adj. from 60 minutes to 20 minutes.

MON 26 SEP 2016 Select function using ↓ .


U10:11:35 L12:11

Accept with YES.


SPEC.-FUNCTIONS Press NO until wished function is shown.

SPEC.-FUNCTIONS Accept with YES.


DEFAULT LT ADJ.

DEFAULT LT ADJ. Change to using ↑↓.


60 m ?

DEFAULT LT ADJ.
Accept with YES.
20 m ?

SPEC.-FUNCTIONS Return to running mode press ←.


DEFAULT LT ADJ.

SPEC.-FUNCTIONS ←

MON 26 SEP 2016


U10:11:35 L12:11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 47 of 51

Display format

With this function the display format in running mode can be selected.

The following three formats can be selected:

Format 1
MON 26 SEP 2016 LT = Local Time.
10:11:00 LT UTC = Universal Time Coordinated.

MON 26 SEP 2016 Format 2 (Default)


U10:11:00 L12:11 L = Local Time
U = UTC

MON 26 SEP 2016 Format 3,


LT Used for test / fault finding.

Example:

MON 26 SEP 2016 Select function using ↓ .


U10:11:35 L12:11

Accept with YES.


SPEC.-FUNCTIONS Press NO until wished function is shown.

SPEC.-FUNCTIONS Accept with YES.


DISPLAY FORMAT

DISPLAY FORMAT Select, by using the arrows, the wished display format.
-1- LT Accept with YES.

SPEC.-FUNCTIONS Return to running mode press ←.


DISPLAY FORMAT

MON 26 SEP 2016


12:11:00 LT

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 48 of 51

Programming form
Function Group Output Type of Day/Date Time
no. signal

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 49 of 51

Fault tracing
The display is blank

A. The green LED “POWER” is light?

A1. No.
A1A. Check the supply voltage.
A1B. Power supply wires connected correctly?

A2. Yes.
A2A. Restart the master clock by switching the supply voltage off and on.

After starting up the master clock, no impulses appear (to correct the slave clocks).

B1. The master clock awaits the time shown by the slave clocks. Impulses will be distributed when correct
time = the time shown by the slave clocks.

Relay outputs are programmed but nothing happens.

C1. The switch on the front panel is in position 0. Correct position is A.

C2. Check that the output is working when the switch is in position 1.

C3. Different program types have different priority. E.g. a programmed date program overrides a signal
point in a week program.
Priority order (1=highest, 3=lowest):
1) Date program 2) Group 3) Week program

Alarm messages

D1. “Short circuit”

Excessive load on the impulse output. Check the slave clock wiring. Impulses are stored (memorised)
during the alarm. When the fault is fixed, all the stored impulses are distributed by rapid impulsing.

D2. “Memory full”

The master clock is out of memory, probably due to incorrect programming. Use week program for
repetitive signals or group for a certain period. See the programming instructions in this manual.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 50 of 51

D3. “Exists”

The signal point is already programmed.

D4. “Not programmed”

When trying to change a non-existing signal point.

Alarm output
The Master Clock is equipped with two separate alarm relays. One relay for general alarm and one for power
failure alarm. See alarm list on page 16 for details.

General alarm 1-2 1-3


Normal mode, no alarm Open Closed
Overload/short circuit alarm Closed Open
Synchronisation alarm Closed Open

Power alarm 8-9 8 - 10


Normal mode, no alarm Open Closed
Power failure alarm Closed Open

General alarm relay Power alarm relay

1 8

2 9

3 10

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Connection diagram

P.O. Box 133


05 (2-WIRE)

SE-545 23 TÖREBODA
IMPULSE OUTP. 4
PIN NO. SIGNAL
1 IMPULSE 4A
2 IMPULSE 4B
3 NO CONNECTION
4 IMPULSE 4A
5 IMPULSE 4B
6 NO CONNECTION
06 07

WESTERSTRAND URFABRIK AB
01 04 7 IMPULSE 4A
PIN NO. SIGNAL REMARK 24VDC
PIN NO. SIGNAL REMARK PIN NO. SIGNAL REMARK 8 IMPULSE 4B

Tel. +46 506 48000


Fax. +46 506 48051
1 PIN NO. SIGNAL
1 CHASSIS GND 1 IMPULSE 1A 9 NO CONNECTION ALARM RELAY
RS485
2 OUTPUT 1 +24
2 -Rx RS485 NMEA INPUT 2 IMPULSE 1B IMPULSE OUTPUT 10 IMPULSE 4A
NO. 1 3 2 0V
3 +Rx RS485 3 IMPULSE 1A 11 IMPULSE 4B
CHASSIS GND 4 3 PE
4 4 IMPULSE 1B 12 NO CONNECTION 1 PROGRAM RELAY
5 OUTPUT
5 -Tx RS485 RS485 OUTPUT 5 IMPULSE 2A
+Tx RS485 6
6 6 IMPULSE 2B IMPULSE OUTPUT 05 (3-WIRE) 2
NO. 2 7 08
7 NC NO CONNECTION 7 IMPULSE 2A IMPULSE OUTP. 4
8 MAINS 85-264VAC
User Manual

8 GND 8 IMPULSE 2B PIN NO. SIGNAL POWER FAILURE


GPS RECEIVER 9 ALARM RELAY PIN NO. SIGNAL
9 + 9 IMPULSE 3A 1 LT FORWARD
OUTPUT
MARINE MASTER CLOCK

10 1 L
10 DCF 10 IMPULSE 3B IMPULSE OUTPUT 2 LT COMMON
NO. 3 11 2 N
11 +24 11 IMPULSE 3A

E-mail:
3 LT REVERSE
24V DC OUT 12

Internet::
12 0V 12 IMPULSE 3B 3 PE
4 LT FORWARD
5 LT COMMON
6 LT REVERSE

02 (OPTION) 03 7 LT FORWARD

ETHERNET 100BASET PIN NO. SIGNAL REMARK 8 LT COMMON

PIN NO. SIGNAL 2 Rx RS232 RS232 INPUT 9 LT REVERSE

1 RX+ 3 Tx RS232 RS232 OUTPUT 10 LT FORWARD

2 RX- 5 GND RS232 SIGNAL GND 11 LT COMMON

3 TX+ 12 LT REVERSE
Edition 7, connector 02 moved. 2016-10-10 PM
6 TX- Edition 6, RS485 +/- switched. 2011-09-06 PM
2468
Author: PM

1 357

info@westerstrand.se
http://www.westerstrand.se
PM 2016-10-10 CONNECTION DRAWING
Page: 51 of 51

Marine master Clock


Date: 2017-12-22
Document: 1717en19.doc

084550-00 7 1 (1)
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 1 of 5

WIRED DCF
TIME CODE-CLOCK
Max. 400 mm in diameter
for Time zone adjustment

TECHNICAL MANUAL

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 2 of 5

General
Westerstrand analogue clock for wired DCF Time-Code from Marine Master Clock provides the possibility to
create a time distribution system, with high accuracy and high reliability.
The clock is intended for connection to a 2-wire bus which combines power supply and serial Time-Code
A built in microprocessor receives the Time Code, reads the position of the hands, and sets the clock to correct
time. The Time-Code, built up according to the DCF-format, contains information about year, month, day hour
and minute. At each minute shift seconds are synchronised as well. The transmission speed is 1 bit/second.
24VDC power supply for the built in electronics is combined with the Time-Code.
The clock is intended for time zone adjustment from a Marine master clock.

Installation
Connect Time code to time code input, connection movement.
The hands will step forward to 12 position and wait there for correct time message.
The speed is approx. 1 step/sec. When an accepted Time message the hands will step forward to correct time.

If the Marine master clock sends out a special time message (Time zone adjustment), the hands will step
forward rapidly to correct time.
The speed of the hands is 10 steps/ sec.

Synchronisation
When the clock has received and accepted a correct time code message, the hands will step forward rapidly.
If the Marine master clock sends out a special time message (Time zone adjustment), the hands will step
forward rapidly to correct time. The speed of hands is 10 steps/ sec.
Automatic feedback control of the hands at 12:00 and 00:00.
If the time code would disappear, the clock continues by means of the built-in quartz crystal.

During a power failure, the clock is temporarily stopped. After the restoration of power the hands steps forward
to the 12.00-position and waits, for a Time-Code to be received.

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 3 of 5

Technical data
Art.no 113160-20,113160-22.113163-20,113163-22
Connection 2-wire
Connection voltage 24VDC combined with serial Time-Code

Type of time code DCF-format with Time zone adjustment.


Microcontroller PIC16F628
Temperature range -20°C to +50°C
Power consumption 20 mA. (113160-20,113160-22)
30 mA. (113163-20,113163-22)

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 4 of 5

113160-20

113160-22

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 5 of 5

113163-20 Ø1 Ø3

4
4
5 M13x1
4.5 TC 87.5
(17.5) 39

113163-22

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 1 of 11

Option
Ethernet
Marine Master Clock

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 2 of 11

List of contents
List of contents ....................................................................................................................................................2
General ................................................................................................................................................................3
Link indicator ..................................................................................................................................................3
Technical data......................................................................................................................................................3
Configuration.......................................................................................................................................................4
Status IP.......................................................................................................................................................5
Work mode (NTP Server or Client) ...............................................................................................................5
WEB browser ......................................................................................................................................................6
Login window..................................................................................................................................................6
Status >>..........................................................................................................................................................7
General >>.......................................................................................................................................................8
Network >>......................................................................................................................................................9
DHCP ..........................................................................................................................................................9
IP .................................................................................................................................................................9
Gateway.......................................................................................................................................................9
Subnetmask..................................................................................................................................................9
DNS .............................................................................................................................................................9
SNMP ..........................................................................................................................................................9
SNMP server ...............................................................................................................................................9
NTP >> ..........................................................................................................................................................10
NTP mode..................................................................................................................................................10
Broadcast/Multicast Server + Interval(s)...................................................................................................10
NTP server 1..5..........................................................................................................................................10
Interval(s) ..................................................................................................................................................10
Max. correction (s) ....................................................................................................................................10
Help>>...........................................................................................................................................................11
Technical remark ...............................................................................................................................................11

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 3 of 11

General
The Ethernet module makes it possible to connect a Master Clock to a LAN (Ethernet Local Area Network).
The module can be built into a Marine Master Clock.

The module can be used for Master Clock remote control, programming of relay outputs, alarm distribution,
supervision and for distribution of correct time. The module can be configured to work as a NTP server or NTP
client.
For transmission of correct and accurate time the NTP (Network Time Protocol) is used. NTP is a part of the
protocol family UDP/IP.
When using the Ethernet module for time distribution the Master Clock can act as a NTP primary server or as a
NTP client.
Units connected to the LAN, supporting NTP, can receive correct time from the Master Clock via the network
module.
Included with the Ethernet module is NyToP, Westerstrand NTP-client for Windows 98/NT/2000/XP/Vista.
For remote control and relay programming the windows based application software QW3Control can be used.
The QW3Control is an option.

To configure the different parameters such as IP-address, work mode etc. a normal WEB-browser is used.

Link indicator
The front panel of the Marine Master Clock has a Link indicator LED.
Link indicator LED ON = Link activated. The Master Clocks is connected to a network.
LED OFF = No link activated. The Master Clock is not connected to a network.

Technical data
Art. no.: 123384-00
Supported protocols: NTP version 1, 2 and 3, RFC1305
(For time distribution) SNTP, RFC 1769
Other supported protocols: FTP (RFC 959)
HTTP
Transport protocol: TCP/IP
IP-address assignment Dynamic, using DHCP, or fixed IP-address
Compatibility: Ethernet version 2/IEEE 802.3
Ethernet: Supports 100BASE-T (RJ45) connections
Ambient temperature: -20°C up to +55°C
Device Management: Web-Based (requires web browser)
NTP client software: NyToP , freeware, manual 1672
Application software: QW3Control art. no. 123396-00, manual 1739

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 4 of 11

Configuration
Most of the configuration parameters are set via an external PC by using a Web-browser, but some of the
settings can also be done from the Master Clock.

The following parameters can be set from the Master Clock by using the special function setup.
• IP address

The following parameters can be viewed from the Master Clock by using the special function status.
• IP address

Example:
Give the module IP-address 192.168.1.66

MON 14 OCT 2007 Select function by using ↓ .


09:07:00 LTw
Accept using YES.
SPEC.-FUNCTIONS Press NO until wished function is displayed.

SPEC.-FUNCTIONS Accept using YES.


SETUP

SETUP Press NO until the text IP is displayed.


IP Accept using YES.

IP Set, by using the arrows, the IP-addess 192.168.001.066.


192.168.001.066?
Accept using YES.

SETUP Return to running mode by using ←.


IP

SPEC.-FUNCTIONS ←
SETUP

SPEC.-FUNCTIONS

MON 14 OCT 2007


09:07:00 LTw

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 5 of 11

Status IP

Link- indicator
Work mode

S L A Activity indicator
192.168.1.10

Present IP-address

Work mode S = Server. The Master Clock works as a NTP time server.
C = Client. The Master Clock works as a NTP time client.

Link indicator L = Link activated. The Master Clocks is connected to a network.


= No link activated. The Master Clock is not connected to a network.

Activity indicator A = Showing the network traffic from / to the Master Clock.

Work mode (NTP Server or Client)


The network module kan work in two different modes
Server:
The Master Clock works as a NTP time server answering to NTP requests from NTP clients.

Client/Server:
The Master Clock is both NTP client and NTP server.
The work mode is set from the Master Clock, SPEC.-FUNKTIONS / SETUP / SYNC.SOURCE.

SYNC.SOURCE = NTP CLIENT


The Master Clock acts as a NTP-client receiving its time from an external NTP server.

SYNC.SOURCE = NMEA, GPS, etc.;


The Master Clock acts as a NTP server providing connected external clients with correct time.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 6 of 11

WEB browser
Login window
The Web interface requires a password. Always use user name admin and a valid password.
Default password is password.

After login a function list is displayed.:

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 7 of 11

Status >>

Displays the Master Clock status. The status is automatically updated every 10th second.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 8 of 11

General >>

To set general parameters.

Name Symbolic name, maximum 48 characters


Example: Station Master Clock.

Password Enter a new password. The password has to be repeated.

Firmware Function to enable firmware download.

Save Save parameters.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 9 of 11

Network >>
Used to set the network parameters.

DHCP
With this function it is defined if the Ethernet modules should receive its IP-address automatically from a DHCP
server or use the static IP-address.

IP
This function is used to give the Ethernet module a static IP-address.

Gateway
This function is used to enter a gateway IP-address.

Subnetmask
This function is used to enter a subnetmask.

DNS
This function is used to enter a name server IP-address.

SNMP
With this code the SNMP functionality can be disabled/enabled.

SNMP server
This function is used to enter the IP-address of the SNMP server.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 10 of 11

NTP >>
Used to set the NTP parameters.

NTP mode
NTP mode is set from the Master Clock keyboard, special function SETUP/SYNC SOURCE. See page 5.
Server: The Ethernet module answers time request from clients.
Client/Server: The Ethernet module acts as both a NTP client and a NTP server.

Broadcast/Multicast Server + Interval(s)


--- No periodic transmission of time. A client will ask for time.
Broadcast Transmit time periodic to IP=255.255.255.255
Multicast Transmit time periodic to IP=224.0.1.1
Client NTP clock
With periodic transmission client network clocks will show a new time quicker. Make sure the
client clock has enabled broadcast/multicast, e.g. NTP mode = Broadcast/Multicast. Also
Country/Timezone = Local Time must be selected in the client clock.

Timebase
With this function the type of time transmitted in the NTP message is chosen. Default=UTC.

NTP server 1..5


This function is used if the Time Central is receiving time from an external NTP Server and NTP
mode Client/Server. The value entered can be either an IP-address or a name if the DNS
server (name server) functionality is used. Server ip address is then the address of the external NTP Server.

Interval(s)
NTP client poll interval in seconds
This function is used if work NTP Client/Server is selected.

Max. correction (s)


This function is used if the Ethernet module is configured as an NTP client
Enter max. correction in seconds. The time is compared with current time in the Time Central. If 0 is chosen,
then no check of the time is done.

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 11 of 11

Help>>
Used to view a pdf help file.

Technical remark
When option Ethernet is mounted and synchronisation source NMEA RS485 is selected the RS485 output can
only be used for transmission of NMEA ZDA time string with fixed baudrate (4800) and data format (8N1).

WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 1 av 5

Technical specification Marine Master clock

General
The master clock has 6 buttons and one (2 line x 16 character) LCD. To facilitate time zone change
there are 2 separate buttons for this purpose. The master clock also has a dimmer to adjust background illumina-
tion.

Technical data
Crystal frequency: 4,915200 MHz.
Accuracy: 0,1 sek./24 hours (+20C°).
Microprocessor: HD6412394.
Time memory: 30 days (Back-up with Super Capacitor)
Ambient temperature: 0° C to +50°C.
Relative humidity: Max. 85% non-condensing.
Case: 19” case according to drawing 085811-00.
IP rating: IP20
Weight: 5.0 kg.
CE-approval, EMC Emission according to EN61000-6-3, Immunity according to EN61000-6-2.

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 2 av 5

Outputs for slave movements *:


Control clocks: Analogue display, with background illumination.
Output 1:
Impulse system: 1/1 minute, 1/2 minute, second, 1/2 second, time code (TC)
Type of time: LT, UTC
Impulse length: Minute 0.1-9.9 sec.
Second 0.1-1 sec.
Output 2:
Impulse system: 1/1 minute, 1/2 minute, second, 1/2 second, time code (TC)
Type of time: LT, UTC
Impulse length: Minute 0.1-9.9 sec.
Second 0.1-1 sec.

Output 3:
Impulse system: 1/1 minute, 1/2 minute, second, 1/2 second, time code (TC)
Type of time: LT, UTC
Impulse length: Minute 0.1-9.9 sec.
Second 0.1-1 sec.

Output 4:
Impulse system: 2-wire, 1/1 minute, 1/2 minute, second, 1/2 second, time code (TC).
3-wire for forward forward/back. 1/1-minute alt. 1/2-minute.

Type of time: LT, UTC


Impulse length: Minute 0.1-9.9 sec.
Second 0.1-1 sec.

Max. load / output: 2A


Total load all
outputs together: 2.5A

The outputs have short circuit protection that is restored automatically.

*Analogue intelligent slave clocks connected to time code output receive the time code and steps to correct time
by rapid impulses. The rapid impulses have a speed of approx. 10 steps /second. To step forward 11 hours takes
approx. 1 minute and 10 seconds.

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 3 av 5

Relay outputs
Number of outputs: 2 Changeover potential-free contacts.
Max load/relay output: 230 V 6A.
Program memory: 100 year (EEPROM).
Signal points: 800

Special pulse output


Relay output no. 2 can be dedicated to send out a special pulse.
When this function is enabled the relay is activated every day for 5 seconds at 02.00 UTC.

Telegraph Logger Clock signal


If one of the impulse outputs is configured to work as telegraph logger clock signal (1/2M-12B), then relay out-
put no. 2 is used to send out a Counter C.W. signal and can not be used for other purposes.

Alarm output
Number of outputs: 2 Changeover potential-free contacts.
Type of alarms
Output no. 1 (general alarm): Overload / short circuit, synchronisation alarm
Output no. 2 (power alarm): Power failure alarm

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 4 av 5

Serial ports
The Master Clock is equipped with two serial ports, one RS232 and one RS422/485.
Both ports can be used either as input or output for serial time messages.
If programmed as output the port can be used to send out time to external equipment such as computers etc.
If programmed as input the port can be used to synchronise the master clock with an external time source pro-
vided with RS232 or RS485 output. The purpose of this is to achieve higher accuracy.

Protocol, data format and baud rate is selectable for respective serial port.

Serial output
Baud rate (selectable): 300, 600, 1200, 2400, 4800, 9600, 19200 baud.

Data format (selectable) 7N1, 7N2, 7O1, 7O2, 7E1, 7E2, 8N1, 8N2, 8O1, 8O2, 8E1, 8E2
No. of data bits: 7 or 8.
Type of parity: None, odd or even.
No. of stop bits: 1 or 2.
Selectable data format:

Available protocols - ZDA Time string, NMEA 0183


- Westerstrand protocol no. 2, 3, 5, 7 etc.
(Automatic time message protocols)

Type of time (selectable): UTC, LT

Serial input
Baud rate: 4800 baud.
Data format: 8N1
Type of protocol: ZDA Time string, NMEA 0183

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 5 av 5

Power supply
The master clock has two inputs for power supply, one for AC, and one for 24V DC. As standard the DC-input
is a direct connected input without galvanic isolation and no compensation for low input voltage. With option
DC/DC the DC-input will be galvanic isolated and low / high input voltage is compensated automatically.

Supply voltage: 90 - 264V 50/60 Hz and 24VDC.


Option DC/DC:
(Galvanic isolated)
Input voltage: 19 - 36VDC
Output voltage: 23 – 30VDC (adjustable)
Isolation voltage: 1500V

Power consumption
AC: 65W
DC: 50W

Options
DC/DC -converter
Ethernet LAN connection
GPS-receiver
Table model
Software for time to computer, WINT

Ethernet LAN (option)


Protocol: NTP according to RFC1305 and RFC1361, TCP/IP
Compatibility: Ethernet version 2/IEEE 802.3
Ethernet: Connection 100BASE-T (RJ45)

WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Calculation of Cable Area in Time Systems

General
To make a time system with impulse operated analog and digital slave clocks that performs
satisfactorily, the cable from the Master Clock to the Slave Clocks needs to be dimensioned
correctly.
A 10% voltage drop is allowed in the cable.
The length and area of the cable and the current (load) on the cable affect the voltage drop.

Formula
A = l x I x k
A = Area [mm2]
l = cable length [m]
I = current [A]
k = 0.015 [constant]

Power Consumption
Impulse Slave Clocks
Analog clocks minute ≤ 400 mm: 7.5 mA
Analog clocks minute ≤ 900 mm: 15 mA
Analog clocks minute + sweep seconds hand ≤ 400 mm: 25 mA
Analog clocks minute 3-wire F/R ≤ 400 mm: 10 mA
Digital Clocks: 5 mA
Time-Code (TC) Slave Clocks
Analog clocks minute ≤ 400 mm: 14 mA (version with movement 113160-00)
Analog clocks minute ≤ 400 mm: 7 mA (version with movement 21634-00)
Analog clocks minute ≤ 900 mm: 20 mA
Analog clocks minute + sweep seconds hand ≤ 400 mm, indoor: 12 mA
Analog clocks minute + sweep seconds hand ≤ 400 mm, outdoor: 20 mA
Analog clocks minute + sweep seconds hand ≤ 900 mm: 27 mA
Time-Code Marine (TCM) Slave Clocks
Analog clocks minute ≤ 400 mm: 20 mA
Analog clocks minute ≤ 900 mm: 20 mA
Analog clocks minute + sweep seconds hand ≤ 400 mm, outdoor: 27 mA
Analog clocks minute + sweep seconds hand ≤ 900 mm: 27 mA

Example
A time system consists of 40 analog clocks with a diameter of 300 mm.
The power consumption will then be 40 x 7.5 = 300 mA = 0.3A
Cable length is 100 meters.
A = 100 x 0.3 x 0.015 = 0.45 mm2
Choose a cable with an area of at least 0.45 mm2.

Doc. no. A100K11451 MCS Cable Calculation Document Date 13.11.2018 HKL
www.zenitel.com
Zenitel Norway AS

DOC NO.

A100K10807 customer.service@zenitel.com
Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Vingtor-Stentofon products are developed and marketed
by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice.
ZENITEL PROPRIETARY. This document and its supplementing elements, contain Zenitel or third party information which is proprietary and confidential. Any disclosure, copying, distribution or use is
prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend. Zenitel – All rights reserved.

You might also like