Professional Documents
Culture Documents
Revision Information
Rev. Date Author Description
V1.0 26.05.2013 SEN Final
V1.1 13.04.2013 SEN Updated 1717en13 to1717en16
Added doc.A100K11451 cable
V1.2 25.07.2013 SEN calculation. New rev. of cable
connection diagram A100K10836
V1.3 16.06.2015 SEN Masterclock; Protection changed
to IP-22, page 8
V1.4 25.11.2015 SEN Updated cable connection
diagram A100K10836
v1.5 12.05.2016 SEN Updated cable connection
diagram A100K10836
v1.6 24.08.2016 SEN Updated A100K10836 , changes
on term.block 6
V1.7 13.11.2018 HKL New manual versions 1717en19 -
1795en03 - 9539en14
V1.8 17.6.2019 HKL Power supply 50/60 Hz
Related Documentation
For further information, refer to the following documentation:
Doc.no. Documentation
A100K10836 Rev.02 Autocad dwg cable connection diagram
A100K10838 Autocad dwg dimension drawing 70000 &
70000L
Note: Autocad drawings and datasheets are available for all slave
clocks
5. Cable Connection
• Cable Connection Diagram
Document: A100K10836 (1 Page)
• Cable Calculation
Document: A100K11451 (1 Page)
• Dimensions Drawing
Document: A100K10838 (1 Page)
User Manual
Marine Master Clock
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 2 of 51
List of contents
TECHNICAL SPECIFICATIONS ............................................................................................................................... 4
GENERAL .............................................................................................................................................................................. 4
SLAVE CLOCK OUTPUT.......................................................................................................................................................... 4
RELAY OUTPUT ..................................................................................................................................................................... 4
ALARM OUTPUT .................................................................................................................................................................... 4
GENERAL DESCRIPTION........................................................................................................................................ 5
PROGRAMMING....................................................................................................................................................... 8
GENERAL .............................................................................................................................................................................. 8
RUNNING MODE .................................................................................................................................................................... 8
START UP PROCEDURE........................................................................................................................................................... 9
1. Start up questions (this page) ................................................................................................................................. 9
2. Output configuration / Setup (page 10) ................................................................................................................... 9
3. Enter time of Slave Clocks (page 12) ...................................................................................................................... 9
OUTPUT CONFIGURATION / SETUP ....................................................................................................................................... 10
SET UTC WHEN IN OPERATION ............................................................................................................................................ 11
SET LOCAL TIME WHEN IN OPERATION ............................................................................................................................... 11
SLAVE CLOCK ..................................................................................................................................................................... 12
TIME ZONE ADJUSTMENT..................................................................................................................................................... 13
ALARMS .............................................................................................................................................................................. 14
Example 1, display alarms ............................................................................................................................................. 14
Example 1, erase alarms ................................................................................................................................................ 15
Alarm list........................................................................................................................................................................ 16
WEEK PROGRAM & DATE PROGRAM .................................................................................................................................. 17
Concept description ....................................................................................................................................................... 17
Week Program, example 1 (New program) .................................................................................................................... 19
Week Program, example 2 (Change program) .............................................................................................................. 20
Week Program, example 3 (Erase program) ................................................................................................................. 21
Week Program, example 4 (Astronomical function) ...................................................................................................... 22
Week Program, example 5 (Block program).................................................................................................................. 23
Week Program, example 6 (Mask program) .................................................................................................................. 24
Date Program, example (New program)........................................................................................................................ 25
DISPLAY PROGRAM ............................................................................................................................................................. 26
TEMPORARY PROGRAM, EXAMPLE ...................................................................................................................................... 27
GROUP => PERIOD .............................................................................................................................................................. 28
SPEC.-FUNCTIONS ............................................................................................................................................................... 29
SPEC.-FUNCTIONS ............................................................................................................................................................... 29
Status.............................................................................................................................................................................. 30
Language ....................................................................................................................................................................... 32
Setup............................................................................................................................................................................... 33
Software version............................................................................................................................................................. 45
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 3 of 51
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 4 of 51
Technical specifications
General
Crystal Frequency: 4,915200 MHz.
Accuracy: 0,1 sec./24 hours (at +20°C).
Microprocessor: HD6412394.
Connection voltage: 90 - 264V 50/60 Hz and. 24 V DC -5% +20 %.
Max ripple (24V DC): 0,7V RMS.
Power consumption: 65 W (max)
Ambient temperature: Between 0° C and +50°C.
Relative humidity: Max. 85% non-condensing.
IP rating: IP20
Weight: 5.6 kg.
CE-Approval, EMC: Emission acc. to EN61000-6-3, Immunity acc. to. EN61000-6-2.
Relay output
Relay outputs: 2 closing potential-free contacts.
Max. load/relay output: 24 V 6A.
Total load relay outputs: 12A
Program memory: 100 years (EEPROM)
Number of control functions: 800.
Alarm output
Number of outputs: 2 Changeover potential-free contacts.
Type of alarms
Output no. 1 (general alarm): Overload / short circuit, synchronisation alarm
Output no. 2 (power alarm): Power failure alarm
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 5 of 51
General description
Westerstrand Marine Master Clock is the ideal solution for distribution of both Local and UTC time on board
ships.
The Master Clock is equipped with several outputs and inputs for control of Slave Clocks as well as distribution
of time to computers and other equipment needing correct time. The four Slave Clock outputs can be
individually programmed for different types of clocks. External radio receivers / time synchronisation sources
can be connected when higher accuracy is needed.
For control and regulation of various energy consumers such as electrical striking plates, buzzers for pause
signalling etc, the master Clock has a built in yearly programmer with two relay outputs.
The Master Clock is equipped with 10 buttons and a 2 x 16 character LCD. To facilitate the change of time zone
two of the buttons are dedicated for this purpose. A light dimmer makes it possible to adjust the background
illumination to the surrounding light level.
The front mounted power switch is an all pole switch and controls both AC and DC power.
Position IN = Power ON.
Position OUT = Power OFF.
1 ALARM
2 POWER
RADIO
LINK
LIGHT + ADV.
UTC
Control keyboard
Monitor Clock Monitor Clock
UTC Local Time
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 6 of 51
Keyboard
LIGHT+ Increase LED backlight level
LIGHT- Decrease LED backlight level
↑↓ Select function / Change and scroll
← Move left / Cancel / Leave programming mode
→ Move right
NO Decline
YES Accept / Enter programming mode
ADV. Advance Local Time
REV. Reverse Local Time
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 7 of 51
Installation
The Marine Master Clock is intended for stand, cabinet, wall or desk mounting.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 8 of 51
Programming
General
Using 6 buttons and a 2-row 16-character display carries out all programming.
Programming is self-instructive and to simplify the dialogue Yes/No questions are used.
Running mode
When the Time Base module is in operation it shows date
and time in the display. MON 26 SEP 2016
This is called running mode in this documentation. U10:11:35 L12:11
SET UTC
SET LT
1- Select function ↑↓
SLAVE CLOCK
2- Enter programming mode YES
ALARMS
3- Move sideways ←→
TEMPORARY PROGR.
GROUP PERIODE
SPEC.-FUNCTIONS
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 9 of 51
Start up procedure
STARTING
When the Master Clock is connected for the first time correct/requested
LANGUAGE language has to be entered. Press NO until requested
ENGLISH? language occurs in the display e.g. English. Accept with YES.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 10 of 51
Default setup:
Slave Clock output no. 4 Impulse system: 3-wire for Forward/Reverse, 1/1-minute.
Type of time: Local Time
Impulse length: 2 sec.
Synchronisation source
NMEA RS485 (NMEA 0183ZDA Time string)
RS232 output
NMSE (NMEA 0183ZDA Time string)
RS485 output
NMSE (NMEA 0183ZDA Time string)
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 11 of 51
MON 26 SEP 2016 The master clock is now back in running mode.
U10:11:00 L12:11
Remark: To do normal Time Zone adjustments use the buttons, ADV and REV.
MON 26 SEP 2016 The master clock is now back in running mode.
U10:11:35 L12:11
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 12 of 51
Slave Clock
IMPULSE OUTPUT 1
= 09:07 OFF Turn ON impulse output 1 by using ↑↓.
MON 26 SEP 2016 The master clock is now back in running mode.
U10:11:35 L12:11
NOTE! If a slave clock runs out by a minute, its cabling must be pole changed and
the slave clock to be corrected manually.
NOTE! If the time of the slave clocks is ahead of correct/present time the Master Clock
will wait until correct time corresponds with the slave clocks.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 13 of 51
To change Local Time zone two buttons are used. The buttons are named ADV and REV.
To advance the Local Time slave clocks to a new time zone press button ADV.
Example:
LOCAL TIME ADJ. Use the default value or change by pressing ADV.
60m ? Accept with YES.
LOCAL TIME ADJ. ! The Local Time slave clocks will now advance 60 minutes.
MON 26 SEP 2016 When the correction is finished the display is automatically returned to
running mode.
U10:11:35 L13:11
To reverse the Local Time slave clocks to a new time zone press button REV.
Example:
LOCAL TIME ADJ. Use the default value or change by pressing REV.
- 60m ? Accept with YES.
LOCAL TIME ADJ. ! The Local Time slave clocks will now be adjusted as below:
1 Min forward clock’s stop 60 min
0,5 Min F/B clock’s: Reverse 60 Min
TC Clock’s: 11 hours forward
MON 26 SEP 2016 When the correction is finished the display is automatically returned to
U10:11:35 L11:11 running mode.
Remark: To interrupt a time zone adjustment in progress press button ← and YES.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 14 of 51
Alarms
This function is used to display and erase the different alarms in the master clock.
ALARMS- DISPLAY ←.
ALARMS ←.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 15 of 51
ALARMS ←.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 16 of 51
Alarm list
The following alarms are available
NO RADIO 30 Red alarm LED lit. The Master Clock has Check the external
General alarm relay activated. not been synchronised synchronisation source. If
within the alarm limit. no external source is used
inactivate the alarm. See
special function/ setup
sync. source page 36.
UF LOW 52 Red alarm LED lit. Impulse voltage below Remove connected clocks
General alarm relay activated. alarm limit. and clear the alarm. If OK,
check clocks and wiring.
SHORT CIRCUIT 53 Red alarm LED lit. Short circuit on impulse Remove short circuit.
Common alarm relay activated. amplifier. If OK, clear the alarm.
CURRENT LOW 61 Red alarm LED lit. Impulse current on Check output connections.
General alarm relay activated. output no. 1 is below If OK, clear the alarm.
alarm limit.
CURRENT LOW 62 Red alarm LED lit. Impulse current on Check output connections.
General alarm relay activated. output no. 2 is below If OK, clear the alarm.
alarm limit.
CURRENT LOW 63 Red alarm LED lit. Impulse current on Check output connections.
General alarm relay activated. output no. 3 is below If OK, clear the alarm.
alarm limit.
CURRENT LOW 64 Red alarm LED lit. Impulse current on Check output connections.
General alarm relay activated. output no. 4 is below If OK, clear the alarm.
alarm limit.
CURRENT HIGH 71 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 1 is above If OK, clear the alarm.
alarm limit.
CURRENT HIGH 72 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 2 is above If OK, clear the alarm.
alarm limit.
CURRENT HIGH 73 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 3 is above If OK, clear the alarm.
alarm limit.
CURRENT HIGH 74 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 4 is above If OK, clear the alarm.
alarm limit.
CURRENT HIGH 75 Red alarm LED lit. Impulse current on Check output load.
General alarm relay activated. output no. 4 is above If OK, clear the alarm.
(Remark: Alarm 75 is only used alarm limit.
in a 3-wire Forward/Reverse
system.)
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 17 of 51
Concept description
Program A "program" refers to programming an output to a certain time. The word program
represents a single time event and several programs are defined as a group of
programs.
For example: output 2 switches on every working day (Monday-Friday) at 8.00.
Week program A week program is a program, which is repeated every week. You can for each
program choose for which days of the week it shall be valid:
Individual or block programming.
M = Monday
T = Tuesday
W = Wednesday
T = Thursday
F = Friday
S = Saturday
S = Sunday
Date program A date program is a program, which is valid for a specific date.
Type of signals There are some different kinds of signals, depending on how the relay output is to
be used.
ON/OFF Is used when a longer lasting switching ON is required, e.g. for controlling fans,
door locks, lighting etc.
Mask A program that is repeated f. ex every hour is easily entered by the use of mask
program.
XX.15.00 ; the program is repeated every hour att minute 15.
08.XX.00 ; the program is repeated every minute between 08.00 and 09.00.
XX.XX.00 ; The program is repeated every minute.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 18 of 51
WEEK PROGRAM
NEW GROUP A To enter new programs.
WEEK PROGRAM
ERASE GROUP A To erase a separate existing program.
WEEK PROGRAM
To change existing programs.
CHANGE GROUP A
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 19 of 51
Example: Outputs No. 2 shall switch on Monday – Friday at 09.00 and off at 17.00.
WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
NEW GROUP A
OUTPUT 2 ON
------- 08:00:00 State type of signal using ↑↓.
OUTPUT 2 ON
MTWTF-- 08:00:00 State the days the program shall function using ↑↓.
Move to the right using →.
OUTPUT 2 OFF Continue with programming OFF for the same output or leave
MTWTF-- 17:00:00 programming by pressing ← several times.
WEEK PROGRAM
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 20 of 51
Example: A signal on output 1, Monday – Friday at 08.00, shall be changed to 08.15. Signal length is 5 seconds.
WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
CHANGE GROUP A
OUTPUT 2 05S
Select output using ↑↓. Move to the right using →.
MTWTF-- 08:00:00
OUTPUT 2 05S
MTWTF-- 08:00:00 Step forward to the program, which is to be changed using NO and YES.
WEEK PROGRAM
Leave the programming by pressing ← several times.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 21 of 51
Example: A signal on output 1, Fridays at 16.30 shall be deleted. Signal length is 5 seconds.
WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
ERASE GROUP A
OUTPUT 1 05S Step forward to the program that is to be erased using NO and YES.
----F-- 16:30:00 Accept using YES.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 22 of 51
Example: Output No. 1 shall switch ON all sunset All days and switch OFF at sunrise.
WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
NEW GROUP A
OUTPUT 2 ASTR
MTWTF-- State type of signal using ↑↓.
OUTPUT 2 ASTR State the days the program shall function using ↑↓.
MTWTF-- Accept using YES.
If the program is approved the text “Program saved” is displayed quickly.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 23 of 51
Example: Outputs No. 2 shall switch on Monday, Wednesday and Friday at 09.00.
WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
NEW GROUP A
OUTPUT 2 ON
------- 08:00:00 State type of signal using ↑↓.
OUTPUT 2 ON
M-W-F-- 08:00:00 State the days the program shall function using ↑↓.
Move to the right using →.
OUTPUT 2 OFF Continue with programming OFF for the same output or leave
M-W-F-- 09:00:00 programming by pressing ← several times
WEEK PROGRAM
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 24 of 51
Example: Outputs No. 2 shall switch on for 5 seconds every hour at minute 15, all days in the week.
WEEK PROGRAM Select group of programs using ↑↓, accept using YES.
NEW GROUP A
OUTPUT 2 05S State the days the program shall function using ↑↓.
MTWTFSS 08:00:00 Move to the right using →.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 25 of 51
OUTPUT 1 ON
AUG 01 08:00:00 State type of signal using ↑↓.
OUTPUT 1 ON
AUG 01 08:00:00 State the date the program shall function using ↑↓.
Move to the right using →.
OUTPUT 1 OFF Continue with programming OFF for the same output or leave
AUG 01 12:00:00 programming by pressing ← several times.
DATE PROGRAM
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 26 of 51
Display Program
DISPLAY PROGRAM Select program group using ↑↓, accept with YES.
GROUP A
DISPLAY PROGRAM Leave the function display program by pressing ← several times.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 27 of 51
Example: Outputs No. 2 shall switch on immediately 15.35.00 and turn off according to normal week program.
The temporary program will automatically be erased when the event has been effected.
OUTPUT 2 ON Accept using YES or change the time of the program using ↑↓.
15:35:00
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 28 of 51
Each program group can be associated to one or several time periods. A time period can consist of one or
several dates. Maximum 99 time periods can be used. Program group A is as default associated to a time period
covering the complete year, 1/1-31/12.
Example:
A school has one group of programs that are used during the school season and another used during school
holidays. School season = Group A, School holidays = Group B.
The school holidays are at the following dates: 1/5, 10/6-15/8, 23/9 and so on...
GROUP B
1:____ - _____ Select group of programs using ↑↓, accept using YES.
GROUP B
State the date when the period shall end.
1:MAY01 – MAY01 Accept with Yes.
GROUP B
2:JUN07 – _____
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 29 of 51
Spec.-Functions
The special functions contain functions used during setup and configuration of the Master Clock.
If the default settings are used no configuration is needed.
STATUS Show status information of the different output/ input in the Master Clock.
LANGUAGE
Language selection.
DISPLAY FORMAT
Display format in running mode.
DEFAULT LT ADJ. Default value used when pressing button ADV or REV.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 30 of 51
Status
Example:
Check the status of the synchronisation source receiver.
NMEA RS485 60% The Master Clock has accepted 60% of the synchronisation messages.
14OCT 19:59:00 Last reception was 14/10 19:59:00.
SPEC.-FUNCTIONS ←
STATUS
SPEC.-FUNCTIONS ←
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 31 of 51
*Remark: For W-GPS the marked position always shows the actual second. This information is updated every
other second.
Impulse current
IL=0.5
12:00 UF=26 V
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 32 of 51
Language
Example:
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 33 of 51
Setup
With this function the different output and input can be configured. If the default setup is used no configuration
is needed.
Example:
Set the alarm limit for synchronisation source alarm to 1 hour. (Default setting is 12 hours.)
NMEA RS485 Set, by using the arrows, the alarm limit to 1 hour (01h).
AL.LIMIT --h -- m
SPEC.-FUNCTIONS ←
SETUP
SPEC.-FUNCTIONS ←
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 34 of 51
Below is a description of the different configuration parameters available in the setup menu for sync. source.
Please remark that if default settings are used no configuration is needed.
Type of synchronisation
NMEA RS485
AL. LIMIT --h--m
Alarm limit
Type of synchronisation
State type of external synchronisation. The following time sources can be selected:
NMEA RS485 (default) Synchronisation using RS485 input and NMEA ZDA protocol.
NMEA RS232 Synchronisation using RS232 input and NMEA ZDA protocol.
W-GPS Radio synchronisation GPS type Westerstrand.
DCF77 Radio synchronisation DCF77.
TC Time code type hard wired DC
-------- No external synchronisation
Alarm limit
The configuration parameter Alarm limit specifies the time delay before the radio alarm is activated. Default
setting is that the radio alarm is inactivated, AL.LIMIT --h--m.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 35 of 51
Below is a description of the different configuration parameters available in the setup menu for impulse output.
Please remark that if default settings are used no configuration is needed.
Impulse type
1/1MIN 24H LT
2.0s?
Impulse length
Type of impulse
Selection of impulse type. The following types are available.
Type of time
LT = Local Time.
UTC = Universal Time Coordinated.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 36 of 51
Impulse length
Configuration of impulse length.
Alarm limits
IL=0.0 - 2.0A
UF= -- V
Impulse feedback
voltage limit
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 37 of 51
Below is a description of the different configuration parameters available in the setup menu for the RS232 and
RS485 input/ output.
Please remark that if default settings are used no configuration is needed. The RS485/422 input protocol is
always fixed to NMEA ZDA Time string and cannot be changed.
Type of time
Type of protocol
NMSE LT
4800 8N1
Type of protocol
Name of the transmission / reception protocol used in the module. The following protocols are available.
Other protocols
1: General 2-way-communication protocol.
2, 3, 5, 7, 16 etc.: Automatic time message protocols.
Type of time
Type of time received or transmitted.
LT = Local Time.
UTC = Universal Time Coordinated.
Baudrate
Available speeds: 300, 600, 1200, 2400, 4800, 9600 baud.
Data format
Data format of message received or transmitted.
No. of data bits, 7 or 8.
Type of parity, none, odd or even.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 38 of 51
Available formats:
7N1, 7N2, 7O1, 7O2, 7E1, 7E2, 8N1, 8N2, 8O1, 8O2, 8E1, 8E2,
Protocol description
ZDA - Time & Date - UTC, Day, Month, Year and Local Time Zone
1 2 3 4 5 6 7
| | | | | | |
$--ZDA,hhmmss.ss,xx,xx,xxxx,xx,xx*hh<CR><LF>
Field Number:
1) Universal Time Coordinated (UTC)
2) Day, 01 to 31
3) Month, 01 to 12
4) Year
5) Local zone description, 00 to +- 13 hours
6) Local zone minutes description, same sign as local hours
7) Checksum
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 39 of 51
Protocol 2
F - Flag bits
7 =0
6 =1
5 =0
4 =0 Winter time, =1 summer time
3 =1 Synced from Radio source, e.g. DCF77
2 =1 Synched from timeserver
1 0 Type of time
OFF OFF UTC
OFF ON LOC
ON OFF NOR
Example:
Assume wintertime time, synched from radio source, synchronized from timeserver, local time:
Bits 6, 3, 2 and 0 are set: 0100 1101 = 4Dh = 'M'
G - UTC offset during wintertime from letter 'P' in 1/2 hour steps.
Example:
Germany 2 x 1/2 = 1 hour, so 'P'+2 = 'R'
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 40 of 51
Protocol 3
At second 56 this message will be transmitted:
Protocol 5
T:YY:MN:DD:WW:HH:MM:SS CR LF (24 bytes)
T = T
: = 3AH
YY = Year 00....99
MN = Month 01....12
DD = Day 01....31
WW = Day of week 01....07
HH = Hour 00....23
mm = Minutes 00....59
ss = Seconds 00....59
CR = Carrige return 0Dh.
LF = Line feed 0Ah.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 41 of 51
Protocol 7
F = '0' Winter-time.
= '1' Summer-time.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 42 of 51
Protocol 16*
STC HH MM SS DD MO MO YY HL HL ML ML ECT
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 43 of 51
Relay output no. 2 can be dedicated to send out a special pulse. When this function is enabled the relay is
activated every day for 5 seconds at 02.00 UTC.
SPEC.-FUNCTIONS ←
SETUP
SPEC.-FUNCTIONS ←
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 44 of 51
Setup NMEA LT
This function is valid only if the Master Clock is synchronised from an external NMEA source. Special function
sync. source must be set to NMEA RS485 or NMEA RS232.
With this function it can be selected if the Master Clock should use the Local Time (LT) information included in
the NMEA time message. The Master Clocks LT will be set to the nearest time with respect to the default value
entered in the special function DEFAULT LT ADJ.
Example:
DEFAULT LT ADJ is set to 20 minutes. Local Time is 15:30.
2. Received LT is changed 10 minutes to 15:40, which is in the middle of 15:30 and 15:50;
Master Clock LT will stay on 15:30.
Default setting is NO, which means that the Local Time information is not used.
NMEA LT
YES ? Accept with YES
SETUP
NMEA LT
Return to running mode press ←.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 45 of 51
SPEC.-FUNCTIONS
SETUP ←
SPEC.-FUNCTIONS
←
MON 26 SEP 2016
U10:11:35 L12:11
Software version
This function shows the software version for the Time Base module.
SPEC.-FUNCTIONS ←
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 46 of 51
Default LT adjust
This function is used to enter the default value used when pressing button ADV or REV.
Example:
Change default LT adj. from 60 minutes to 20 minutes.
DEFAULT LT ADJ.
Accept with YES.
20 m ?
SPEC.-FUNCTIONS ←
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 47 of 51
Display format
With this function the display format in running mode can be selected.
Format 1
MON 26 SEP 2016 LT = Local Time.
10:11:00 LT UTC = Universal Time Coordinated.
Example:
DISPLAY FORMAT Select, by using the arrows, the wished display format.
-1- LT Accept with YES.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 48 of 51
Programming form
Function Group Output Type of Day/Date Time
no. signal
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 49 of 51
Fault tracing
The display is blank
A1. No.
A1A. Check the supply voltage.
A1B. Power supply wires connected correctly?
A2. Yes.
A2A. Restart the master clock by switching the supply voltage off and on.
After starting up the master clock, no impulses appear (to correct the slave clocks).
B1. The master clock awaits the time shown by the slave clocks. Impulses will be distributed when correct
time = the time shown by the slave clocks.
C2. Check that the output is working when the switch is in position 1.
C3. Different program types have different priority. E.g. a programmed date program overrides a signal
point in a week program.
Priority order (1=highest, 3=lowest):
1) Date program 2) Group 3) Week program
Alarm messages
Excessive load on the impulse output. Check the slave clock wiring. Impulses are stored (memorised)
during the alarm. When the fault is fixed, all the stored impulses are distributed by rapid impulsing.
The master clock is out of memory, probably due to incorrect programming. Use week program for
repetitive signals or group for a certain period. See the programming instructions in this manual.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1717en19.doc
MARINE MASTER CLOCK Author: PM
Date: 2017-12-22
User Manual Page: 50 of 51
D3. “Exists”
Alarm output
The Master Clock is equipped with two separate alarm relays. One relay for general alarm and one for power
failure alarm. See alarm list on page 16 for details.
1 8
2 9
3 10
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Connection diagram
SE-545 23 TÖREBODA
IMPULSE OUTP. 4
PIN NO. SIGNAL
1 IMPULSE 4A
2 IMPULSE 4B
3 NO CONNECTION
4 IMPULSE 4A
5 IMPULSE 4B
6 NO CONNECTION
06 07
WESTERSTRAND URFABRIK AB
01 04 7 IMPULSE 4A
PIN NO. SIGNAL REMARK 24VDC
PIN NO. SIGNAL REMARK PIN NO. SIGNAL REMARK 8 IMPULSE 4B
10 1 L
10 DCF 10 IMPULSE 3B IMPULSE OUTPUT 2 LT COMMON
NO. 3 11 2 N
11 +24 11 IMPULSE 3A
E-mail:
3 LT REVERSE
24V DC OUT 12
Internet::
12 0V 12 IMPULSE 3B 3 PE
4 LT FORWARD
5 LT COMMON
6 LT REVERSE
02 (OPTION) 03 7 LT FORWARD
3 TX+ 12 LT REVERSE
Edition 7, connector 02 moved. 2016-10-10 PM
6 TX- Edition 6, RS485 +/- switched. 2011-09-06 PM
2468
Author: PM
1 357
info@westerstrand.se
http://www.westerstrand.se
PM 2016-10-10 CONNECTION DRAWING
Page: 51 of 51
084550-00 7 1 (1)
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 1 of 5
WIRED DCF
TIME CODE-CLOCK
Max. 400 mm in diameter
for Time zone adjustment
TECHNICAL MANUAL
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 2 of 5
General
Westerstrand analogue clock for wired DCF Time-Code from Marine Master Clock provides the possibility to
create a time distribution system, with high accuracy and high reliability.
The clock is intended for connection to a 2-wire bus which combines power supply and serial Time-Code
A built in microprocessor receives the Time Code, reads the position of the hands, and sets the clock to correct
time. The Time-Code, built up according to the DCF-format, contains information about year, month, day hour
and minute. At each minute shift seconds are synchronised as well. The transmission speed is 1 bit/second.
24VDC power supply for the built in electronics is combined with the Time-Code.
The clock is intended for time zone adjustment from a Marine master clock.
Installation
Connect Time code to time code input, connection movement.
The hands will step forward to 12 position and wait there for correct time message.
The speed is approx. 1 step/sec. When an accepted Time message the hands will step forward to correct time.
If the Marine master clock sends out a special time message (Time zone adjustment), the hands will step
forward rapidly to correct time.
The speed of the hands is 10 steps/ sec.
Synchronisation
When the clock has received and accepted a correct time code message, the hands will step forward rapidly.
If the Marine master clock sends out a special time message (Time zone adjustment), the hands will step
forward rapidly to correct time. The speed of hands is 10 steps/ sec.
Automatic feedback control of the hands at 12:00 and 00:00.
If the time code would disappear, the clock continues by means of the built-in quartz crystal.
During a power failure, the clock is temporarily stopped. After the restoration of power the hands steps forward
to the 12.00-position and waits, for a Time-Code to be received.
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 3 of 5
Technical data
Art.no 113160-20,113160-22.113163-20,113163-22
Connection 2-wire
Connection voltage 24VDC combined with serial Time-Code
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 4 of 5
113160-20
113160-22
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1785en03.doc
INTELLIGENT CLOCKS Author.: TAn
Date: 2009-11-04
Page: 5 of 5
113163-20 Ø1 Ø3
4
4
5 M13x1
4.5 TC 87.5
(17.5) 39
113163-22
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 1 of 11
Option
Ethernet
Marine Master Clock
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 2 of 11
List of contents
List of contents ....................................................................................................................................................2
General ................................................................................................................................................................3
Link indicator ..................................................................................................................................................3
Technical data......................................................................................................................................................3
Configuration.......................................................................................................................................................4
Status IP.......................................................................................................................................................5
Work mode (NTP Server or Client) ...............................................................................................................5
WEB browser ......................................................................................................................................................6
Login window..................................................................................................................................................6
Status >>..........................................................................................................................................................7
General >>.......................................................................................................................................................8
Network >>......................................................................................................................................................9
DHCP ..........................................................................................................................................................9
IP .................................................................................................................................................................9
Gateway.......................................................................................................................................................9
Subnetmask..................................................................................................................................................9
DNS .............................................................................................................................................................9
SNMP ..........................................................................................................................................................9
SNMP server ...............................................................................................................................................9
NTP >> ..........................................................................................................................................................10
NTP mode..................................................................................................................................................10
Broadcast/Multicast Server + Interval(s)...................................................................................................10
NTP server 1..5..........................................................................................................................................10
Interval(s) ..................................................................................................................................................10
Max. correction (s) ....................................................................................................................................10
Help>>...........................................................................................................................................................11
Technical remark ...............................................................................................................................................11
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 3 of 11
General
The Ethernet module makes it possible to connect a Master Clock to a LAN (Ethernet Local Area Network).
The module can be built into a Marine Master Clock.
The module can be used for Master Clock remote control, programming of relay outputs, alarm distribution,
supervision and for distribution of correct time. The module can be configured to work as a NTP server or NTP
client.
For transmission of correct and accurate time the NTP (Network Time Protocol) is used. NTP is a part of the
protocol family UDP/IP.
When using the Ethernet module for time distribution the Master Clock can act as a NTP primary server or as a
NTP client.
Units connected to the LAN, supporting NTP, can receive correct time from the Master Clock via the network
module.
Included with the Ethernet module is NyToP, Westerstrand NTP-client for Windows 98/NT/2000/XP/Vista.
For remote control and relay programming the windows based application software QW3Control can be used.
The QW3Control is an option.
To configure the different parameters such as IP-address, work mode etc. a normal WEB-browser is used.
Link indicator
The front panel of the Marine Master Clock has a Link indicator LED.
Link indicator LED ON = Link activated. The Master Clocks is connected to a network.
LED OFF = No link activated. The Master Clock is not connected to a network.
Technical data
Art. no.: 123384-00
Supported protocols: NTP version 1, 2 and 3, RFC1305
(For time distribution) SNTP, RFC 1769
Other supported protocols: FTP (RFC 959)
HTTP
Transport protocol: TCP/IP
IP-address assignment Dynamic, using DHCP, or fixed IP-address
Compatibility: Ethernet version 2/IEEE 802.3
Ethernet: Supports 100BASE-T (RJ45) connections
Ambient temperature: -20°C up to +55°C
Device Management: Web-Based (requires web browser)
NTP client software: NyToP , freeware, manual 1672
Application software: QW3Control art. no. 123396-00, manual 1739
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 4 of 11
Configuration
Most of the configuration parameters are set via an external PC by using a Web-browser, but some of the
settings can also be done from the Master Clock.
The following parameters can be set from the Master Clock by using the special function setup.
• IP address
The following parameters can be viewed from the Master Clock by using the special function status.
• IP address
Example:
Give the module IP-address 192.168.1.66
SPEC.-FUNCTIONS ←
SETUP
SPEC.-FUNCTIONS
←
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 5 of 11
Status IP
Link- indicator
Work mode
S L A Activity indicator
192.168.1.10
Present IP-address
Work mode S = Server. The Master Clock works as a NTP time server.
C = Client. The Master Clock works as a NTP time client.
Activity indicator A = Showing the network traffic from / to the Master Clock.
Client/Server:
The Master Clock is both NTP client and NTP server.
The work mode is set from the Master Clock, SPEC.-FUNKTIONS / SETUP / SYNC.SOURCE.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 6 of 11
WEB browser
Login window
The Web interface requires a password. Always use user name admin and a valid password.
Default password is password.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 7 of 11
Status >>
Displays the Master Clock status. The status is automatically updated every 10th second.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 8 of 11
General >>
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 9 of 11
Network >>
Used to set the network parameters.
DHCP
With this function it is defined if the Ethernet modules should receive its IP-address automatically from a DHCP
server or use the static IP-address.
IP
This function is used to give the Ethernet module a static IP-address.
Gateway
This function is used to enter a gateway IP-address.
Subnetmask
This function is used to enter a subnetmask.
DNS
This function is used to enter a name server IP-address.
SNMP
With this code the SNMP functionality can be disabled/enabled.
SNMP server
This function is used to enter the IP-address of the SNMP server.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 10 of 11
NTP >>
Used to set the NTP parameters.
NTP mode
NTP mode is set from the Master Clock keyboard, special function SETUP/SYNC SOURCE. See page 5.
Server: The Ethernet module answers time request from clients.
Client/Server: The Ethernet module acts as both a NTP client and a NTP server.
Timebase
With this function the type of time transmitted in the NTP message is chosen. Default=UTC.
Interval(s)
NTP client poll interval in seconds
This function is used if work NTP Client/Server is selected.
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 1795en03.doc
WESTERSTRAND Author: PM
Date: May 8, 2014
Page: 11 of 11
Help>>
Used to view a pdf help file.
Technical remark
When option Ethernet is mounted and synchronisation source NMEA RS485 is selected the RS485 output can
only be used for transmission of NMEA ZDA time string with fixed baudrate (4800) and data format (8N1).
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 1 av 5
General
The master clock has 6 buttons and one (2 line x 16 character) LCD. To facilitate time zone change
there are 2 separate buttons for this purpose. The master clock also has a dimmer to adjust background illumina-
tion.
Technical data
Crystal frequency: 4,915200 MHz.
Accuracy: 0,1 sek./24 hours (+20C°).
Microprocessor: HD6412394.
Time memory: 30 days (Back-up with Super Capacitor)
Ambient temperature: 0° C to +50°C.
Relative humidity: Max. 85% non-condensing.
Case: 19” case according to drawing 085811-00.
IP rating: IP20
Weight: 5.0 kg.
CE-approval, EMC Emission according to EN61000-6-3, Immunity according to EN61000-6-2.
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 2 av 5
Output 3:
Impulse system: 1/1 minute, 1/2 minute, second, 1/2 second, time code (TC)
Type of time: LT, UTC
Impulse length: Minute 0.1-9.9 sec.
Second 0.1-1 sec.
Output 4:
Impulse system: 2-wire, 1/1 minute, 1/2 minute, second, 1/2 second, time code (TC).
3-wire for forward forward/back. 1/1-minute alt. 1/2-minute.
*Analogue intelligent slave clocks connected to time code output receive the time code and steps to correct time
by rapid impulses. The rapid impulses have a speed of approx. 10 steps /second. To step forward 11 hours takes
approx. 1 minute and 10 seconds.
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 3 av 5
Relay outputs
Number of outputs: 2 Changeover potential-free contacts.
Max load/relay output: 230 V 6A.
Program memory: 100 year (EEPROM).
Signal points: 800
Alarm output
Number of outputs: 2 Changeover potential-free contacts.
Type of alarms
Output no. 1 (general alarm): Overload / short circuit, synchronisation alarm
Output no. 2 (power alarm): Power failure alarm
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 4 av 5
Serial ports
The Master Clock is equipped with two serial ports, one RS232 and one RS422/485.
Both ports can be used either as input or output for serial time messages.
If programmed as output the port can be used to send out time to external equipment such as computers etc.
If programmed as input the port can be used to synchronise the master clock with an external time source pro-
vided with RS232 or RS485 output. The purpose of this is to achieve higher accuracy.
Protocol, data format and baud rate is selectable for respective serial port.
Serial output
Baud rate (selectable): 300, 600, 1200, 2400, 4800, 9600, 19200 baud.
Data format (selectable) 7N1, 7N2, 7O1, 7O2, 7E1, 7E2, 8N1, 8N2, 8O1, 8O2, 8E1, 8E2
No. of data bits: 7 or 8.
Type of parity: None, odd or even.
No. of stop bits: 1 or 2.
Selectable data format:
Serial input
Baud rate: 4800 baud.
Data format: 8N1
Type of protocol: ZDA Time string, NMEA 0183
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Document: 9539en14.doc
WESTERSTRAND Author: PM
Date: 2018-08-15
Page: 5 av 5
Power supply
The master clock has two inputs for power supply, one for AC, and one for 24V DC. As standard the DC-input
is a direct connected input without galvanic isolation and no compensation for low input voltage. With option
DC/DC the DC-input will be galvanic isolated and low / high input voltage is compensated automatically.
Power consumption
AC: 65W
DC: 50W
Options
DC/DC -converter
Ethernet LAN connection
GPS-receiver
Table model
Software for time to computer, WINT
WESTERSTRAND URFABRIK AB
Box 133 Tel. 0506 48000 Internet:: http://www.westerstrand.se
545 23 TÖREBODA Fax. 0506 48051 E-mail: info@westerstrand.se
Calculation of Cable Area in Time Systems
General
To make a time system with impulse operated analog and digital slave clocks that performs
satisfactorily, the cable from the Master Clock to the Slave Clocks needs to be dimensioned
correctly.
A 10% voltage drop is allowed in the cable.
The length and area of the cable and the current (load) on the cable affect the voltage drop.
Formula
A = l x I x k
A = Area [mm2]
l = cable length [m]
I = current [A]
k = 0.015 [constant]
Power Consumption
Impulse Slave Clocks
Analog clocks minute ≤ 400 mm: 7.5 mA
Analog clocks minute ≤ 900 mm: 15 mA
Analog clocks minute + sweep seconds hand ≤ 400 mm: 25 mA
Analog clocks minute 3-wire F/R ≤ 400 mm: 10 mA
Digital Clocks: 5 mA
Time-Code (TC) Slave Clocks
Analog clocks minute ≤ 400 mm: 14 mA (version with movement 113160-00)
Analog clocks minute ≤ 400 mm: 7 mA (version with movement 21634-00)
Analog clocks minute ≤ 900 mm: 20 mA
Analog clocks minute + sweep seconds hand ≤ 400 mm, indoor: 12 mA
Analog clocks minute + sweep seconds hand ≤ 400 mm, outdoor: 20 mA
Analog clocks minute + sweep seconds hand ≤ 900 mm: 27 mA
Time-Code Marine (TCM) Slave Clocks
Analog clocks minute ≤ 400 mm: 20 mA
Analog clocks minute ≤ 900 mm: 20 mA
Analog clocks minute + sweep seconds hand ≤ 400 mm, outdoor: 27 mA
Analog clocks minute + sweep seconds hand ≤ 900 mm: 27 mA
Example
A time system consists of 40 analog clocks with a diameter of 300 mm.
The power consumption will then be 40 x 7.5 = 300 mA = 0.3A
Cable length is 100 meters.
A = 100 x 0.3 x 0.015 = 0.45 mm2
Choose a cable with an area of at least 0.45 mm2.
Doc. no. A100K11451 MCS Cable Calculation Document Date 13.11.2018 HKL
www.zenitel.com
Zenitel Norway AS
DOC NO.
A100K10807 customer.service@zenitel.com
Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Vingtor-Stentofon products are developed and marketed
by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice.
ZENITEL PROPRIETARY. This document and its supplementing elements, contain Zenitel or third party information which is proprietary and confidential. Any disclosure, copying, distribution or use is
prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend. Zenitel – All rights reserved.