Founded in 1988, Beijing Creative Distribution Automation Co.

, Ltd (CREAT) is a share holding high-


tech enterprise based on China Electric Power Research Institute (EPRI), and focus on power
distribution systems.
CREAT is the key supplier of FTU devices, Fault Indicators and 10kV power equipment such as
Pad-Mounted Transformer, Pad-Mounted Switchgear, Molded Cable Connectors, Recloser etc, as
well as Distribution Automation solutions.
CREAT has an experienced engineering team which covers the electronics, computer, switchgear,
transformer and high voltage engineering both on R&D and on manufacturing.
CREAT has a professional marketing and sales team which keeps the business relationship with
over a thousand power utilities around Mainland China.
CREAT is creating better technology, quality, service and reputation!
FI Series Fault Indicator

FI Series Fault Indicator


General
FI Series Fault Indicator are used to locate the fault in distribution systems by indicating the path
of fault current, help the crews trace the path of fault current and locate the fault more efficiently,
greatly reduce the time and cost of fault location, and enhance the reliability of power supply.

Principle
Recognize the characters of short-circuit current:
the current increment I caused by short-circuit fault.
The line voltage and current drop to zero because of short-circuit.
Meeting all the above 2 conditions at the same time is the criterion of action indication.

Type Code

FI
3h
Reset Time 6h
12h
default (24h or 20min)
Indication & Signal Default: flag
Transmisstion Mode F: add flash
O: add fibre-optic transmission signal
W: add wireless transmission signal
Design Serial No.
1.2.3...(or default)
A: naked wire
B: busbar
Application Place
C: cable
D: overhead insulated wire
P: Panel
Drive Power 2: line current
3: add lithium battery

fault indicator

Note: Special application place (rail line, self-closing line, above 35kV line etc.) or special re-
quirements please indicate when ordering.
CHARACTERISTICS
CHARACTERISTICS
Features
Fault Identification fault identification function, no need to define actuate current ratings.
recognize the fault character. For permanent faults, reset after re-
Automatic Reset energized. For instantaneous faults, reset in defined time.
eliminate misact phenomenon of closing field-excitation inrush.
Inrush Restrain directly installed on line and work outside chronically.
Live Line Operation

Overhead Line Sketch Map

Substation C.B. 1 2
3
4 5 6

Fault Indicating Normal Indicating Fault Point

Cable System Sketch Map


Pad-Mounted Switchgear or
switching station Cable Sector

Substation CB 1 2

15 years experience
More than 1,000,000 pieces work in field
FI Series Fault Indicator

FI-3AF/3DF Overhead Line Fault Indicator


Apply to Overhead Line

Features
Fault Identification short-circuit fault identification, no need to
define actuate current rating;

Automatic Reset recognize the fault character. For permanent


fault (power off time is more than 15 min),
maintain indicating during this period less
than defined time and reset in 2 min after
re-energized,other wise, reset in defined
time.For instantaneous fault (power off time
FI-3AF for overhead is less than 10 min), reset in defined time.
naked wire
Inrush Restrain eliminate misact phenomenon of closing
field-excitation inrush.

Live Line Operation directly installed on line and work outside


chronically.

Live Line Installing and can be installed or removed on live line.


Removing

Indication Mode red flag or flash light which can be indicated


in a range of 360 . Minimum visible dis-
tance in night is 500m.

Rustproof the structural parts are made of rustproof


FI-3DF for overhead material
insulated conductor
Night Vision Reflec- the indication flag adopts reflectance
tance Technology material, easy for night observation.

Inverse Time Limit Op- maximally suits the protecting operating


erating Characteristic characteristic of substation, and improve the
actuate accuracy rating.
RATINGS
RATINGS
Ratings
Line Voltage (1~35)kV
Minimum Load Current insulated wire2A
naked wire 0A
Conductor Size FI-3AF Φ(8~25)mm
FI-3DF Φ(8~41)mm
Short Time Withstand Current 31.5kA/2s
Reset Time of Instantaneous Fault 3h, 6h (12h)
FI-3AF
Temperature Range -35 70
Operation Life 2000times
Continuous Flash Time 1000h
Flash Intervals 5.3s 20%
Weight FI-3AF:520g
FI-3DF:500g

FI-3DF

FI-3AF Mounting and Removing Cup


FI Series Fault Indicator

FI-2C1 Cable Type Fault Indicator


Apply to Cable
Features
Fault Identification fault identification function, no need to de-
fine the actuate current
Automatic Reset automatic reset in 20 minutes after re-
energized.
Inrush Restrain eliminate misact phenomenon of closing
field-excitation inrush.
Live Line Operation directly installed on the equipments that use
cable.
Live Line Installing can be installed or removed on live line
and Removing

Indication Mode red flag.

Rustproof structural parts are made of rustproof


material.
Night Vision Reflec- the indication flag adopts reflectance
tance Technology material, easy for night observation.

Inverse Time Limit maximally suits substation about the pro-


Operation Character- tecting operating characteristic, and as-
istics sured the actuate accuracy rating.

Ratings
Line Voltage (1~35)kV
Minimum Load Current 8A
Conductor Size Φ(8~41)mm
Short Time Withstand Current 31.5kA/2s
Reset Time After Re-energized 20min
Temperature Range -35 70
Operation Life 2000times
Weight 450g
PRODUCTINTRODUCTION
PRODUCTINTRODUCTION
FI-2B1 Busbar Type Fault Indicator
Apply to Equipment Which Uuse Busbar
Features
Fault Identification fault identification function, no need to define
the actuate current rating.

Automatic Reset automatic reset in 20 minutes after re-


energized.

Inrush Restrain eliminate misact phenomenon of closing field-


excitation inrush.
Live Line Operation directly installed on the equipments that use
busbar.
Indication Mode red flag, can observe from sides and top.
Rustproof the structural parts use rustproof material.
Night Vision Reflec- the indication flag adopts reflectance material,
tance Technology easy for night observation.
Inverse Time Limit maximally suits substation about the protect-
Operating Character- ing operating characteristic, and assured the
istic actuate accuracy rating.
Ratings
Line Voltage (0~35)kV
Minimum Load Current 8A
Applicable Busbar Size Width:(40~60)mm;
Thickness:(4~10)mm
Short Time Withstand Current 31.5kA/2s
Reset Time After Re-energized 24min
Temperature Range -35 70
Operation Life 2000times
Weight 450g
FI Series Fault Indicator

FI-2C1O/3PO, FI-2B1O/3PO
Panel Type Fault Indicator
General
3 detectors installed on phase and one FI-3PO fault indicator installed on pad-mounted switchgear panel
compose this product.
Busbar outline adopts FI-2B1O as sensor.
Cable outline adopts FI-2C1O as sensor.

FI-2C1O/3PO FI-2B1O/3PO

Features
Fault Identification have the function of short-circuit fault identification, no need to
define the actuate current rating.
Inrush Restrain eliminate misact phenomenon of closing field-excitation inrush.
Reset Mode by hand or automatic reset.
Indication Mode flash light.
Live Line Installing and Removing detectors can be installed or removed on live line.
Rustproof the structural parts use rustproof material.
Inverse Time Limit Operating maximum suits substation about the protecting operating
Characteristic characteristic, and improve the actuate accuracy rating.
Enclosed Electron Switch send fault signal to FTU by electron switch on/off to implement
the supervisory function
Optical Fiber Transfer Signal isolate primary and secondary connection, and to ensure equip-
ments and personnel safety.
Equipement Self-Checking Button can check inside battery situation of FI-3PO fault indicator
momentarily.
RATINGS
RATINGS
Ratings
Line Voltage (1~35)kV
Minimum Load Current 8A
Conductor Size Φ(8~41)mm
Busbar Size Wide(40~60)mm Thick(4~10)mm
Short Time Withstand Current 31.5kA/2s
Reset Time After Re-energized 20min
Temperature Range -35 ~ 70
Operation Life 2000times
Weight 450g

FI-2C1O

FI-2B1O
FI Series Fault Indicator

FI-3PO Fault Indicating


Ratings

Electron Switch Output Capacity 1A/DC220V


Electron Switch Maximum Cut-off Leakage Current 150uA/DC600V
Electron Switch Maximum Turn-on Voltage Drop 2V/0.1A
Electron Switch Turn-on Time 2.64s
Flash Interval Time 1.32s
Flash Automatic Reset Time 3h, 6h
Temperature Range -35 +70
Weight 310g
Transimit Fibre-Optic Maximum Length 5m
Inside Battery Capacity 2Ah (can indicate 200 faults)

Installing Hole Dimension


PRODUCTINTRODUCTION
PRODUCTINTRODUCTION

FI-2C1O/3P1O Panel Type Fault Indicator


General
This product is suitable for locating faults of small resistance
grounding system and composed of 3 FI-2C1O fault indicators
installed on cable, one FI-CT-1/2 zero-phase sequence cur-
rent-transformer and one FI-3P1O fault indicator installed on
pad-mounted switchgear panel.

Features
Fault Identification FI-2C10 has the function of short-circuit fault identification, no need
to define the actuate current rating.
FI-CT-1 zero-phase sequence current-transformer actuate value and
respond time can be set continuously.
Inrush Restrain eliminate misact phenomenon of closing field-excitation inrush.
Reset Mode by hand or automatic reset.
Indication Mode flash light.
Live Line Installing and Removing FI-2C1O fault indicator can be installed or removed on live line.

Rustproof the structural parts use rust-proof material.


Inverse Time Limit Operating maximum suits substation about the protecting operating
Characteristic characteristic, and improve the actuate accuracy rating.
Optical Fiber Transfer Signal isolate primary and secondary connection, to ensure equipments
and personnel safety.
Equipement Self-Checking Button be able to inside battery situation of FI-3P1O fault indicator
momentarily.
Ratings
Line Voltage 1~35 kV
Minimum Load Current 8A
Conductor Size Φ (8~41)mm
Short Time Withstand Current 31.5kA/2s
Reset Time After Re-energized 20min
Temperature Range -35 ~ 70
Operation Life 2000times
Weight 450g
FI Series Fault Indicator

FI-CT-1 Zero-Phase Sequence Current-Transformer


Ratings
Zero-phase current actuate value can be adjusted continuously:
(10~ 300)A
Conductor Size: Φ(50~90)mm.
PRODUCTINTRODUCTION
PRODUCTINTRODUCTION
SFI-3P1O Fault Indicator
Ratings

Electron Switch Output Capacity 1A/DC220V


Electron Switch Maximum Cut-off Leakage Current 150uA/DC600V
Electron Switch Maximum Turn-on Voltage Drop 2V/0.1A
Electron Switch Turn-on Time 2.64s
Flash Interval Time 1.32s
Flash Automatic Reset Time 3h, 6h
Temperature Range -35 ~+70
Weight 310g
Transimit Fibre-Optic Maximum Length 5m
Inside Battery Capacity 2Ah (can indicate 200 faults)

Zero Current Respond Time Can 40ms 2s


Be Adjusted Continuously

Installing Hole Dimension


FI Series Fault Indicator

Application