Professional Documents
Culture Documents
And Recommendations
Owen does not warrant the
products described will work
properly in all environments
and applications, and makes
no representation or warranty,
express or implied, with respect
to their quality, performance,
© 2020 Owen Oil Tools All Rights Reserved
StimGun™, StimTube™, KODIAK and WST are registered trade marks of Owen Oil Tools. PulsFrac is a registered trade marked product of Baker Hughes.
casing and secondly, not all material would
General Recommendations be initiated or burnt. Consider the KODIAK
Enhanced Perforating System as a possible
solution.
Dual casing strings and scenarios with very
small EHD perforation holes can also be
problematic for effective stimulation, and are
not recommended.
How effective is the Perforating System™, which is ideal for Can StimGun™ sleeves and
StimGun™ procedure?
horizontals to treat with new perforations
StimTube™ material be
and propellant stimulation. If StimGun™ is still
considered, it is VERY important to protect used with acid?
This procedure has a proven 95% success the exposed propellant material from friction
rate as a perforation breakdown tool. In order on casing or sand, which can be present in YES. The StimGun™ material is not effected
for the StimGun™ or StimTube™ process horizontals. As with vertical wells, oversized by acid reactivity and many jobs have been
to be effective, there likely has to be some Finned Subs and oversized Retaining Rings performed with acid as the tamp fluid. Xylene
type of problem in the near wellbore area. are a must. Extreme slow running speed (< is currently the only known chemical that will
If the problem is low permeability, then 30 feet/min in perfect well conditions) must effect and damage StimGun™ material.
propellants may not be the solution. However, be taken. Also consider Well Stimulation Tool
Owen propellant systems have proven to (WST), a solid stick propellant run inside a What is the recommended
be effective as a pre-frac breakdown tool to spent TCP carrier or a specially made open
minimize tortuosity effects to ensure that scallop carrier as an alternative. This would be
fluid level for StimGun™ or
all perforations are broken down to accept a special order StimTube™?
frac fluids and proppant. The StimGun™ or
StimTube™ technique may enhance but may The sleeves require a minimum of 500 psi
or may not replace a hydraulic Frac job, if the
Can StimGun™ service be of hydrostatic pressure to ensure complete
formation requires one to be commercial. used with limited entry and proper burn. The propellant needs to be
The technique has also proven to yield ignited in an incompressible liquid, therefore
better completion efficiencies (negative skin perforating? propellants should not be used to treat dry gas
factors) on TCP/StimGun™ underbalance jobs, wells without spotting a non-damaging tamp
NO. A minimum of 4 spf and at least 5 feet
compared to offset wells shot with TCP and liquid. Wells flowing gas can present problems
of perforations with a minimum of 3 feet of
underbalance. with Stim applications where damage or
StimGun™ Sleeve is required for a successful
StimGun™ service. Anything shorter than loss of hardware is possible if ignited in a gas
Can StimGun™ be used in 3 feet results in insufficient pressure being bubble or gasified fluid as well as poor results
from the propellant stimulation. PulsFrac®
horizontal wells? generated to stimulate the formation. The
Modeling is always recommended for each job.
system is not compatible with limited entry
YES, however, proper procedures must be type perforating or 0° shot phasing due to
followed. Consider the KODIAK Enhanced the possibility of damaging the customers Should the fluid column
exist all the way to surface?
What are the StimGun™ sleeve’s temperature limits?
Owen Recommended StimGun™ Time /Temp Chart for maximum exposure time limits. NO. A minimum of a 100 foot air gap is
required from the fluid top to the THF
Owen Chart Title
Time (hr) Recommended
1
Maximum (F)
400
420
Is gun configuration
400
10 398.5 important?
Temperature (F)
20 392.5 380
30 386 YES, when running the StimGun™ sleeves it
360 is important to properly protect the product.
40 380
80gr. It should still work, INCH SGS-T412-35A SLEEVE STIM-GUN 4-1/8” OD X 3-1/2” ID 3.50” 36” 4.25” UN 0349 EAR99 1.4S
INCH SGS-T472-40A SLEEVE STIM-GUN 4-3/4” OD X 4” ID 4.0” 36” 5.0” UN 0349 EAR99 1.4S
correct? INCH SGS-T525-45A SLEEVE STIM-GUN 5-1/4” OD X 4-1/2” ID 4.50” 36” 5.5” UN 0349 EAR99 1.4S
INCH SGS-T525-46A SLEEVE STIM-GUN 5-1/4” OD X 4-5/8” ID 4.625” 36” 5.5” UN 0349 EAR99 1.4S
NO. The 80gr primacord is too powerful and
INCH SGS-T588-50A SLEEVE, STIM GUN, 5-7/8” OD X 5” ID 5.0” 36” 6.06” UN 0349 EAR99 1.4S
it will definitely split and break the carrier
INCH SGS-T588-51A SLEEVE, STIM GUN, 5-7/8” OD X 5 1/8” ID 5.125” 36” 6.06” UN 0349 EAR99 1.4S
tube resulting in the tools LIH and/or being
INCH SGS-T787-70A SLEEVE STIM-GUN 7-7/8” OD X 7” ID 7.0” 36” 8.16” UN 0349 EAR99 1.4S
unable to pull the tools out of the hole. 1
Sleeve can be ordered in lengths of 1ft, 2ft or 3 ft at time of order
2
Canada Classification is 1.4S, UN0349
damage to the hollow stud resulting in flaring EACH STS-1687-T03A StimTube™ SYS 1-11/16” OD x 3FT 2.25” 38.5” UN 0349 EAR99 1.4S
of the material causing a burr similar to those EACH STS-2000-T01A StimTube™ SYS 2” OD x 1FT 2.5” 14.5” UN 0349 EAR99 1.4S
seen on a gun scallop. Therefore, in order to EACH STS-2000-T02A StimTube™ SYS 2” OD x 2FT 2.5” 26.5” UN 0349 EAR99 1.4S
eliminate any possible confusion engineering EACH STS-2000-T03A StimTube™ SYS 2” OD x 3FT 2.5” 38.5” UN 0349 EAR99 1.4S
has elected to recommend this charge not be EACH STS-2500-T02A StimTube™ SYS 2-1/2” OD x 2FT 3.0” 26.5” UN 0349 EAR99 1.4S
loaded across from the hollow stud.
EACH STS-2500-T03A StimTube™ SYS 2-1/2” OD x 3FT 3.0” 38.5” UN 0349 EAR99 1.4S
EACH STS-3000-T02A StimTube™ SYS 3” OD x 2FT 3.5” 26.5” UN 0349 EAR100 1.4S
The PulsFrac model is EACH STS-3000-T03A StimTube™ SYS 3” OD x 3FT 3.5” 38.5” UN 0349 EAR99 1.4S
predicting a peak pressure 1 Measured from center of top collar to center of bottom collar
2 Canada Classification is same as US Classification
KODIAK
Enhanced Perforating System™
Can I run multiple Kodiak SPF). The reason is that increasing the pellet
quantity will exceed the pressure rating of the
guns in one run and select gun and it would burst.
fire?
YES you can, but please contact Owen to make
How far do the fractures
sure you set this up correctly. For example, it is extend? Can I shoot Kodiak in a gas
necessary to download the last charge closest
to the switch and replace with a blank charge This is totally dependent on rock properties, well?
case to protect the switch. overburden and a number of other factors.
YES, But the tamp fluid must not be gasified.
Realistically, 2-6 feet from wellbore and six
For vertical wells, we recommend to limit to You must also keep a minimum of 100 foot air
feet of height are typical.
one gun per run as the shock from bottom gun gap on top of fluid column to prevent damage
may damage the pellets in the upper gun. What is the minimum gun to wellhead.
Can I run Kodiak guns in (a) Laboratory explosive test Pressure vs. time for typical explosive event
horizontal wells?
Propellant event
YES. Kodiak guns were designed for Horizontal
wells as an alternative to StimGun™. The
advantages are that you do not have to worry
about protecting the sleeve and secondly you can
run larger OD guns with bigger charges.
(c) Laboratory hydraulic fracture test Pressure vs. time for typical hydraulic fracturing
Can I run Kodiak with
StimGun™ sleeve together?
Great question!! it has never been tested before,
but possibly.
All users of the product must first develop their own instruction manual based on their company specific safety policies, procedures,
and best practices. All users must also develop their own set of operational procedures for each specific well stimulation.
StimGun™, StimTube™, KODIAK Enhanced Perforating System™ and WST are
registered trade marks of Owen Oil Tools. PulsFrac is a registered trade marked product of Baker Hughes.