Professional Documents
Culture Documents
30 November 2023
Todays Agenda
SURFACE DOWNHOLE
Repair Wellhead and Xmas Tree Seals
Downhole Safety Valve
Control Line
Tubing Hanger Seals
Production Packer
Metal to Metal Seals
Tubing / Casing Connection
Tubing Hanger Void
Well Leak Repair Conductor Leak
Seal Assemblies
Liner Hanger
Services Pipeline Leak
5 Jalan Riong
HYPERSEAL SOLUTIONS SDN BHD
WELL INTEGRITY SOLUTIONS EXPERT Bangsar
All Rights Reserved 59100 Kuala Lumpur
HYPERSEALANTS – Applications
Downhole Leaks
Control Line X X
Downhole Safety Valve X X
Production Packer X X
Seal Stem / Polished Bore Receptacle X
Tubing / Casing Connection Leak X X X
Sliding Side Door X
Side Pocket Mandrels / Injection Valves X
Umbilical Lines X
SCP – Micro Annular Channeling X X X
Plug & Abandonment (P&A Assurance) X
Time Activated
Sealant Type Sealant
(TAS)
Liquid
Physical State
(2 Parts – Ratio 10:1)
Pressure Rating 10,000psi
a) TAS in liquid form
Temperature Rating 0 - 260 deg C
Epoxy Resin
Sealant Type
HYPER-ER
Pipe Wrapping
Sealant Type System
HYPER-WRAP
Fibre Cloth, Putty,
Physical State
Epoxy
Pressure Rating 1,500psi
Min – 350psi
Max – 2750psi
Acceptance
1st Barrier! Criteria:
Contingency TAS
Internal Seal Repair PAS Injection Max. 5% pressure
Injection setup injection
drop & 0 psi PBU
1) Hook up injection line to GIF/Test Port. 1) Perform PAS Injection 1) Perform TAS Injection
2) Pressure Test line 2) Re-evaluate seal 2) Curing Time for 24
3) Perform Diagnostic Procedure performance (in-situ) by hours
Verify potential leak communication pressure drop test 3) Perform Integrity Test
4) Quantify leak severity 3) Curing Time for 24 hours
Leak Rate / Injectivity Rate 4) Perform Integrity Test
Pressure Drop/Built Up Rate
5) Sealant selection
Leak rate <1.2 LPM @ 1500 psi = PAS
Leak rate > 1.2 LPM @ 1500 psi = TAS
2nd Barrier!
Acceptance Criteria:
Gas Seepage Application of
NO visible gas fume
Encapsulation Surface Preparation Metal Repair Putty Fiberglass Wrap
537
520
410
400
395
320
220
190
184
100
90
78
75
72
70
60
60
55
50
30
25
9
5
0
0
0
0
0
0
D1 D2 D3 D4 D5 D6
SPE-199192-MS • Improved Rectification Procedure for
High Annulus Pressure Issues during Production Phase
• Mohamad Kamil Saharuddin
HYPERSEAL SURFACE MONITORING
Remote Wireless Monitoring Sensors
Products & Services
Sustained Casing Pressure
P&A
Production
Monitor Operational
Well Monitoring
Services
5 Jalan Riong
HYPERSEAL SOLUTIONS SDN BHD WELL INTEGRITY SOLUTIONS EXPERT Bangsar
All Rights Reserved 59100 Kuala Lumpur
Operational Requirement
Deployment Equipment Package
Pump down subsea umbilical Pump down tubing, spot via Annulus Intervention
or service line. SSD Services
Pelican Case
#2
Pelican Case
#1
The Solution
• Diagnostic tests to quantify presence, communication
path, and severity of leak in 11 wells.
• Multiple treatment options on site to cover for
uncertainties utilizing Time Activated Sealants.
The Solution
• Diagnostic tests to quantify presence,
communication path, and severity of leak in all the
casing hanger seal ports of each conductor.
• Combination of sealant treatment using PAS & TAS.
• Hyperwrap was introduced to secure the gap and act
as secondary barrier for the leak.
The Solution
• Diagnostic test with severe injectivity leak rate (616 ml/min @
3500 psi ) and PBU rate ( 305 psi/ 30min).
• Optimize volumetric deployment of proprietary Pressure
Activated Sealant (PAS) to seal leak in-situ base on leak
severity.
• Continuous sealing performance evaluation throughout the
rectification work.
• Installation of On-site Setting Back Pressure Manifold (BPM) to
resolve gas ingress issues.
Client : EXXON MOBIL Malaysia (EMEPMI)
Location: Tabu Bravo, Offshore Malaysia The Results
• Severe leak in CL (Insert Valve) sealed after several positive
Project : CL Leak Diagnostic and Rectification and negative pressure test.
• No more gas blowing out when bleed off CL.
Year : 2022 • Good indication of flowtube movement and Tubing Inflow test
re-instate the CL and TRSV functionality.
The Solution
• 5 bbl. of pressure activated sealant (PAS) was displaced
into the annulus and squeezed thru leak at packer
• Performed over 50 lab tests (and system integrity test)
that include (i) HiVis vs PAS Compatibility Test (ii) Fall
Rate Test (iii) TAS vs PAS Sealing Test (iv) Pumpability
Test (v) Spacer Viscosity and Breaker Test (vi) Crude vs
Sealant Compatibility in Water Quality
The Challenges
• Rig-less, small footprint, fit-for-purpose equipment requirement
• Logistic – remote location
• Existing fluid compatibility / density
• Well construction integrity
The Objective
• To seal gas migration / pressure built up on surface cement plug leak using
engineered epoxy resin (weigh up density higher than existing completion fluid)
• Effective sealant placement method via macaroni tubing deployment (mud
circulation out and resin injection on top of cement).
The Solution
• Well leak diagnostic (i) injectivity test (ii) PBU rate (iii) surface integrity pressure test.
• Sealant placement design through macaroni tubing (1~2 bbl.)
Client : Genting Oil Kasuri Pte Ltd • Sealant squeeze and placement resin plug on top of leak area (within MASP)
• Rectification acceptance criteria (i) perform integrity test (ii) PBU rate before & after.
Location: ASAP & BEDIDI, West Papua Indonesia
The Results
Project : Cement Plug Leak Rectification
• Successfully injected 2 bbl. of resin plug via Macaroni String
Year : 2022 • Cured resin under surface pressure (24 hrs)
• No PBU recorded post-sealant treatment
• Fit-for-purpose equipment work as intended
HYPERSEAL SOLUTIONS SDN BHD 5 Jalan Riong
All Rights Reserved WELL INTEGRITY SOLUTIONS EXPERT Bangsar
59100 Kuala Lumpur
RESIN APPLICATION (P&A)