You are on page 1of 2

JB0803- ISOLUX

BOLT CALCULATION FOR M24 ANCHOR BOLT


MAXIMUM UPLIFT FORCE ( COLUMN C'-2') = 4.6 KN ( DUE TO WIND ALONG -Z AXIS )
DESIGN DIAMETER = 27 mm
Nos. OF BOLTS PROVIDED = 4 Nos
MAXIMUM HORIZONTAL FORCE (COLUMN C'-3') = 16.4 KN ( DUE TO SEISMIC ALONG X AXIS )
UPLIFT PER BOLT = 1.15 KN ( DUE TO WIND ALONG -Z AXIS )
LENGTH OF EMBEDMENT PROVIDED = 950 mm

CHECK FOR EMBEDED LENGTH


As per AISC guidelines
L= √Apsf/3.14 mm

Apsf (required surface area) = Tu ( sq. mm)


4Φt√f'c
where
Tu = force in N = 1150
Φt = resistant factor = 0.75
f'c = compressive strength of concrete = 32 N/sq.mm

Apsf = 67.76 mm

L= 4.65 mm

Minimum length of embedment = 12 d = 324.00 mm

PROVIDED LENGTH > 4.65 mm or 324 mm HENCE SAFE

CHECK FOR TENSION


As per ACI-318

Nsa = n Ase,N futa


where
Nsa = nominal stregth in tension in Newton
n = nos. of bolts in a group. = 4
Ase,N = effective x-sectional area of a single bolt = πd2
4
= 572.265 ( sq. mm)
futa = not greater than 1.9 fya or 861.845 N/sq.mm(125000 psi) whichever is less
fya = yield strenth of anchor steel in N/sq.mm = 250

Nsa = 1087.3035 KN > 4.6 KN


HENCE SAFE

CHECK FOR SHEAR


As per ACI-318

Vsa = n 0.6 Ase,V futa


where
Vsa = nominal stregth in shear in pounds
n = nos. of bolts in a group. = 4
Ase,V = effective x-sectional area of a single bolt = πd2
4
= 572.265 ( sq. mm)
futa = not greater than 1.9 fya or 861.845 N/sq.mm(125000 psi) whichever is less
fya = yield strenth of anchor steel in N/sq.mm = 250

Vsa = 652.3821 KN > 16.4 KN


HENCE SAFE

CHECK FOR PULL OUT


As per ACI-318

Npn = Ψc,p Np
where
Npn = nominal pull out stregth in pounds
Ψc,p = modification factor = 1.4
and
Np = 8 Abrg f'c
where
Abrg = net bearing area of bolt head(dia 2d) = πd2
4
= 2289.06 ( sq. mm)
f'c = compressive strength of concrete = 32 N/sq.mm

Np = 585999.4 Newton

now Npn = 820.3991 KN > 1.15 KN


HENCE SAFE