Detail Design, Drawing and Cost estimate of Dadeldhura Sabhabhawan

Design Calculation of Septic Tank


Design Data:
1.00 No. of person 50 nos
2.00 Water supply 200 lit/day
3.00 Sewage generation 85% of W/S
4.00 Detention period 24 hours
5.00 Cleaning period 1 year
7.00 Length/Breadth 2.00 m
8.00 Height 1.20 m
9.00 Sludge Deposite 40.00 lit/person/year
10.00 Minimum freeboard 300 mm

Calculation for Septic Tank


1.00 Waste water coming from sabhabhawan to septic tank 8500 lit/day
2.00 Capacity of tank required 8500 Lit
3.00 Capacity required for Sludge accumulation 2000 Lit/year
4.00 Total Volume required 10500 Lit
5.00 Total Volume required 10.5 m3
6.00 Area of Tank 8.75 m2
7.00 Breadth 2.1 m
8.00 Length 4.2 m
9.00 Total depth of tank 1.50 m

Calculation for Soak pit


1.00 Waste water coming out from septic tank 8500 lit/day
2.00 percolation rate 1500 lit/m3/day
3.00 Volume of filter media 5.67 m3
4.00 Assume depth of pit 2 m
5.00 Area of soak pit 2.84 m3
6.00 Diameter of soak well required 1.9 m2

Output Data
1.00 Description unit Septic Tank SoakPit
2.00 Length m 4.2
3.00 Breadth m 2.1
4.00 Diameter m 1.9
5.00 Height m 1.50 2