You are on page 1of 1

Specification/Notes:

Blockwork/Brickwork
Fixed using 2 1/2 " No 10 Wood screw
Fixings to be cut Flush to exposed and plugs @ 600 Ctrs (Max), by
steel Face Fineline

10 Tol
Concrete
Fixed using 2 1/2 " No 10 Wood screw
and plugs @ 600 Ctrs (Max), by
Fineline
70
Pivot SAPA - CDCWB drip cill Timber/Studwork
arm fixed with AW3000 stud Fixed using 2 1/2 " No 10 Wood screw
@ 600 Ctrs (Max) by Fineline

68
Int./ext. mastic seals by others

4
following Fineline installation. Steelwork/Steel Lintols

FFL to Underside of Structure


Fixed using Heavy Duty Tek screws
visible screw (M6x25mm) Nom 75mm Long @ 600 Ctrs (Max) by

Structural opening
Fineline
HDPE packer cut between

Frame size
pivot & locks hold in place

44
Fixing Lugs
with 1mm double sided tape Where fixing lugs are required fix using
M6 x 12mm S/Steel Machine Screws,
Internal & external finishes Lugs fixed to structure as per fixings

Leaf size
by others after installation 34 listed above.

50

Sight size
INSIDE OUTSIDE
63 Head channel

Line of head channel

Line of head channel

Sight size
71
FFL to Underside of Structure

Leaf size
drainage channel with SAPA - CDCWB drip cill

Frame size
20x10mm holes @ max fixed with AW3000 stud
400mm centres
© Copyright reserved by Fineline Aluminium. No
reproduction of this drawing without prior

Structural opening
1mm double sided tape to permission.
secure threshold in place

100
Dorma 8021 10 Tol D
Mastic seals by Fineline bottom strap C

B
Dorma BTS80 floor
A 29/03/17 Threshold detail amended - MAR
spring with 78x60 pocket
27/03/17 Initial Issue Drawing
Drainage hole 00

Rev: Date: Description:


DPC by Fineline
FFL FALL

19
Dorma BTS80
Unit T, Aisecome Way, Weston-Super-Mare,
floor spring with North Somerset, BS22 8NA
82 x 60 pocket
75

75
Tel: 01934 429922 Fax: 01934 416796
www. finelinealuminium.co.uk
DPM by Others email: info@finelinealuminium.co.uk
Site Details:
Southfield Barn
Stanton Harcourt Road
Builder to ensure an adequate drainage Eynsham
solution is installed to remove any water Oxford
discharged from Fineline installation. OX29 4HY
Bespoke Wade drain By Others contact Architect:
CWD Architects
101.5 Pivot Box David Brown Tel: 01787 273998 Email: Contract Number: Drawing Number:
tech@wade.eu
107.5 Ref 14
FL4536 FD-53
Drawing Name: Vertical Section

Dwg Scale: Drawn By: ANR


1: 1.25 @ A1
Client Signature................................................... Date..................... 1: 2.5 @ A3
Reviewed By: IJS

ARCHITECTS RETURNED DRAWING STATUS: STATUS A - ISSUE FOR CONSTRUCTION & PROCEED WITH MANUFACTURE STATUS B - APPROVED SUBJECT TO COMMENTS STATUS C - REVISE DETAILS & RE-ISSUE FOR APPROVAL Date: 23/03/17 Revision: A