Professional Documents
Culture Documents
00M
VI
Date :
Settings
(input for current task)
Materials and standards
Concrete structures : ACI 318-11
Wall analysis
Active earth pressure calculation : Mazindrani (Rankine)
Passive earth pressure calculation : Mazindrani (Rankine)
Earthquake analysis : Mononobe-Okabe
Shape of earth wedge : Consider always vertical
Base key : The base key is considered as inclined footing bottom
Allowable eccentricity : 0.167
Verification methodology : Safety factors (ASD)
Safety factors
Permanent design situation
Safety factor for overturning : SFo = 2.00 [–]
Safety factor for sliding resistance : SFs = 2.00 [–]
Safety factor for bearing capacity : SFb = 1.00 [–]
Material of structure
Unit weight = 23.00 kN/m 3
Analysis of concrete structures carried out according to the standard ACI 318-11.
1
MURO DE CONTENCION H=8.00M
The origin [0,0] is located at the most upper right point of the wall.
Wall section area = 8.43 m2.
Name : Geometry Stage - analysis : 1 - 0
0.25
7.30 16.25:1
8.00
8.95
1.45 4.00
0.70
1.65
6.15
0.70
Foundation
Type of foundation : input parameters of contact base-soil
Parameters
2
MURO DE CONTENCION H=8.00
8.00
8.95
6.15
Terrain profile
Terrain behind construction has the slope 1: 5.67 (slope angle is 10.00 °).
Water influence
Ground water table is located below the structure.
Resistance on front face of the structure
Resistance on front face of the structure: 1/3 pass., 2/3 at rest
Soil on front face of the structure - SUELO CONTENIDO
Soil thickness in front of structure h = 0.50 m
Terrain in front of structure is flat.
3
MURO DE CONTENCION H=8.00M
8.00
8.95
0.50
6.15
4
MURO DE CONTENCION H=8.00M
519.46
8.00
8.95
193.99
346.12
2.56
+x
6.15
+z
Eccentricity verification
Max. eccentricity of normal force e = 0.045
Maximum allowable eccentricity ealw = 0.167
Eccentricity of the normal force is SATISFACTORY
5
MURO DE CONTENCION H=8.00M
8.00
8.95
6.15
6.15
168.73
96.72
Dimensioning No. 1
Wall stem check - front reinf.
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -3.07 79.67 0.44 1.000
Pressure at rest 276.77 -2.43 0.00 0.70 1.000
Wall stem check - front reinf.
Front reinforcement is not required.
Wall stem check - back reinf.
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -3.07 79.67 0.44 1.000
Pressure at rest 276.77 -2.43 0.00 0.70 1.000
Wall stem check - back reinf.
Wall check at the construction joint 7.30 m from the wall crest
Reinforcement and dimensions of the cross-section
6 prof. No. 6, cover 75.0 mm
6 prof. No. 6, cover 75.0 mm
Inputted reinforcement area = 3420.3 mm 2
Required reinforcement area = 2848.2 mm 2
Cross-section width = 1.00 m
Cross-section height = 0.70 m
Reinforcement ratio = 0.56 % > 0.33 % = min
Position of neutral axis c = 0.09 m < 0.26 m = cmax
6
MURO DE CONTENCION H=8.0
Wall jump check
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -1.69 193.99 2.80 1.000
FF resistance -2.56 -0.17 0.00 0.00 1.000
Weight - earth wedge 0.00 -4.53 519.46 4.18 1.000
Active pressure 340.86 -2.27 60.10 6.15 1.000
Wall jump check
Reinforcement and dimensions of the cross-section
5 prof. No. 5, cover 75.0 mm
Inputted reinforcement area = 989.7 mm 2
Required reinforcement area = 910.2 mm 2
Cross-section width = 1.00 m
Cross-section height = 0.70 m
Reinforcement ratio = 0.16 % > 0.15 % = min
Position of neutral axis c = 0.03 m < 0.26 m = cmax
Ultimate shear force Vn = 348.74 kN > 209.00 kN = Vu
Ultimate moment Mn = 222.10 kNm > 154.50 kNm = Mu
Cross-section is SATISFACTORY.
Wall heel check
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -0.35 64.40 4.15 1.000
Weight - earth wedge 0.00 -4.53 519.46 4.18 1.000
Active pressure 340.86 -2.27 60.10 6.15 1.000
Contact stress 0.00 0.00 -480.55 4.02 1.000
Wall heel check
Reinforcement and dimensions of the cross-section
9 prof. No. 6, cover 75.0 mm
Inputted reinforcement area = 2565.2 mm 2
Required reinforcement area = 2414.6 mm 2
Cross-section width = 1.00 m
Cross-section height = 0.70 m
Reinforcement ratio = 0.42 % > 0.33 % = min
Position of neutral axis c = 0.07 m < 0.26 m = cmax
Ultimate shear force Vn = 347.85 kN > 163.42 kN = Vu
Ultimate moment Mn = 556.55 kNm > 525.46 kNm = Mu
Cross-section is SATISFACTORY.
7
MURO DE CONTENCION H=8.00M
519.46
8.95
346.12
6 prof. No. 6, cover. 75.0mm, h1=4.80m, h2=7.30m, l=2500mm
+x
5 prof. No. 5, cover. 75.0mm
6.15
+z
480.55
Name : Dimensioning Stage - analysis : 1 - 1
519.46
8.95
346.12
6 prof. No. 6, cover. 75.0mm, h1=4.80m, h2=7.30m, l=2500mm
+x
5 prof. No. 5, cover. 75.0mm
6.15
+z
480.55
8
MURO DE CONTENCION H=8
519.46
8.95
346.12
6 prof. No. 6, cover. 75.0mm, h1=4.80m, h2=7.30m, l=2500mm
+x
5 prof. No. 5, cover. 75.0mm
6.15
+z
480.55
Name : Dimensioning Stage - analysis : 1 - 1
519.46
8.95
346.12
6 prof. No. 6, cover. 75.0mm, h1=4.80m, h2=7.30m, l=2500mm
+x
5 prof. No. 5, cover. 75.0mm
6.15
+z
480.55