Professional Documents
Culture Documents
30.0 Relative Error (%flow rate) - Operating Range Oil Water Gas WC
30.1 GVF = 0-80%
30.2 GVF = 80-95%
30.3 GVF = 95-99%
30.4 WC = 0-60%
30.5 WC = 60-80%
30.6 WC =80-100%
30.7 Salinity = 0-6000 ppm
30.8 Salinity = 6000-20,000 ppm
30.9 Salinity = 20,000-50,000 ppm
30.11 Viscosity= 0-100 Centipoises
30.12 Viscosity= 100-1000 Centipoises
30.13 Viscosity= 1000-10,000 Centipoises
30.14 Sand content up to ----% by volume
40.0 For the Above Performance Accuracy:
40.1 Meter automatically adjusts for salinity
40.2 Salinity data is entered by calibration/manually
40.3 Meter automatically adjusts for viscosity
40.4 Viscosity data is entered by calibration/manually
40.5 Accuracy if,fluid property changes are not corrected
1 of 12
55
Appendix 3 Part 2 Wet Gas Metering Systems - Vendor Specification Survey
2 of 12
56
Appendix 3 Part 3 Multiphase Metering Systems - Performance Questionaire
During Installation and Commissioning Domestic USA including Alaska Outside the USA and Alaska
203
Applications eng
Service engineer
Software
204 During standard warranty
Applications eng
Service engineer
Parts
Labor
Software upgrades
205 During extended warranty (purchased)
Applications eng
Service engineer
Parts
Labor
Software upgrades
206 After warrranty expiration
Applications eng
Service engineer
Parts
Labor
Software upgrades
3 of 12
57
Appendix 3 Part 3 Multiphase Metering Systems - Performance Questionaire
4 of 12
58
Appendix 3 Part 3 Multiphase Metering Systems - Performance Questionaire
5 of 12
59
Appendix 3 Part 3 Multiphase Metering Systems - Performance Questionaire
500 Environmental
501 Ambient temperature - process instrument
501.1 High
501.2 Low
502 Ambient temperature - Display device
502.1 High
502.2 Low
503 Process temperature - process instrument
503.1 High
503.2 Low
504 Cover required
504.1 Process instrument
504.1.1 Sun shield
504.1.2 Rain shield
504.1.3 Building
504.2 Display instrument
504.2.1 Sun shield
504.2.2 Rain shield
504.2.3 Building
505 Rain
505.1 Falling
505.2 Wind driven
506 Dust resistant
507 Relative humidity
507.1 Non-condensing
507.2 Condensing
508 Vibration
508.1 Process
508.2 Display
600 Electrical
6 of 12 P
60
Appendix 3 Part 3 Multiphase Metering Systems - Performance Questionaire
1003.0 Is the FAT document available to API Task Group Yes No.
1100 After Commissionening,how do you verify the accuracies for the following:
1101 Rate Min Max
1101.1 Total liquid rate
1101.2 Total gas rate
1101.3 Oil rate
1101.4 Water rate
1101.5 Water cut
1101.6 GVF - Gas volume fraction at the meter
1101.7 What referennce you use
1102 After the measurement system has been commissioned how does it react to
7 of 12
61
Appendix 3 Part 4 Wet Gas Metering Systems - Performance Questionaire
During Installation and Commissioning Domestic USA including Alaska Outside the USA and Alaska
203
Applications eng
Service engineer
Software
204 During standard warranty
Applications eng
Service engineer
Parts
Labor
Software upgrades
205 During extended warranty (purchased)
Applications eng
Service engineer
Parts
Labor
Software upgrades
206 After warrranty expiration
Applications eng
Service engineer
Parts
Labor
Software upgrades
8 of 12
62
Appendix 3 Part 4 Wet Gas Metering Systems - Performance Questionaire
9 of 12
63
Appendix 3 Part 4 Wet Gas Metering Systems - Performance Questionaire
10 of 12
64
Appendix 3 Part 4 Wet Gas Metering Systems - Performance Questionaire
1400 Communication
1401 What communication protocols are developed and ready for use
1402 What distance can separate the process and display units at what baud rates?
1403 What cableing is required for communication?
1404 What cableing is required for other hookup
1500 Software and computers
1501 How are calibration factors and changes tracked for retention and audit purposes?
1502 How track software model changes made and tracked if done at site?
1503 Are calibration factor changes and software model changes kept at the factory referenced to the specific meter?
11 of 12
65
Appendix 3 Part 4 Wet Gas Metering Systems - Performance Questionaire
1703.0 Is the FAT document available to API Task Group Yes No.
1705 After the measurement system has been commissioned how does it react
12 of 12
66