revision date: 17 August 2007 expiry date: 16 February 2010

PUSAT PENDIDIKAN DAN PELATIHAN MINYAK DAN GAS BUMI - CEPU


Accreditation Number : LK-035-IDN
Address : Jl. Sorogo No. 1 Cepu, Blora
Telephone : 0296-421888
Facsimile : 0296-421891
Contact Person : Reindhardt Alex George
Temperature approved signatory: Reindhart Alex George

Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)

1 Liquid in glass thermometer -40 °C ~ 200 °C 0.6 °C ASTM E-77-1998


2 Termocouple 0 °C ~ 600 °C 2 °C ASTM E-220-2002
3 Temperature indicator without sensor 0 °C ~ 1700 °C 0.2 °C EA 10/11: 2000
4 Temperaturesensor with display unit -40 °C ~ 600 °C 2 °C JIS 8710: 1993
5 Temperature enclosure:
oven 40 °C ~ 400 °C 2 °C
inkubator 10 °C ~ 80 °C 2 °C AS 2853-1986
water bath 15 °C ~ 100 °C 2 °C
furnace 300 °C ~ 1200 °C 2 °C
Mass approved signatory: Reindhart Alex George, Kasturi

Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)

1 Balance 0g ~ 100 g 0.2 mg

(electronic) 100 g ~ 200 g 0.7 mg The Calibration


200 g ~ 500 g 1.1 mg of Balance
500 g ~ 1000 g 6.1 mg NML-CSIRO: 1995
1000 g ~ 2000 g 7 mg
Volume approved signatory: Reindhart Alex George, Kasturi

Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)

1 Volumetric Glassware; 1 mL ~ 5 mL 0.01 mL


Volumetric Measures 5 mL ~ 10 mL 0.02 mL
10 mL ~ 25 mL 0.05 mL AS 2162: 1996
25 mL ~ 50 mL 0.1 mL
50 mL ~ 100 mL 0.2 mL
Densitas approved signatory: Reindhart Alex George, Kasturi

Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)

1 Hydrometer 0.8 g/cm3 ~ 2 g/cm3 0.001 g/cm3 The Calibration


of Standard Hydrometer
FW. Cuckow JSCI 1949
Pressure approved signatory: Dwi Heri Sudaryanto

Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)

Pressure Test Gauge, Pressure


1 Indicator,Electronic Pressure Transmitter, 1 kgf/cm² ~ 350 kgf/cm² 0.15 %
Pneumatic Pressure Transmitter (hydraulic)

Pressure gauge, Pressure


2 Indicator,Electronic Pressure Transmitter, 0 kgf/cm² ~ 150 kgf/cm² 1.8 kgf/cm² BS-EN 837: 1998
Pneumatic Pressure Transmitter (hydraulic)

3 Pressure Gauge; Pressure indicator; 0 psi ~ 30 psi 0.15 psi EA 10/17: 2002

Electronic Pressure Transmitter, Pneumatic


0 psi ~ 200 psi 1 psi
Pressure Transmitter (pneumatic)

4 Vacuum Gauge -900 bar ~ 0 bar 80 mbar


(1 psi = 6894,76 Pa)
(1 kgf/cm² = 9,80665 x 104 Pa )
Electrical approved signatory: Ali Supriyadi

No. Instrument to be calibrated Measurement Range BMC* Methods/Specifications Notes

1 DC Voltmeter 32 mV ~ 320 mV 0.26 mV/V Metode Intern:


0,32 V ~ 3,2 V 0.23 mV/V 300/MK/05.01/LK
3,2 V ~ 32 V 0.22 mV/V Kalibrasi Voltmeter DC
32 V ~ 320 V 0.24 mV/V
320 V ~ 1050 V 0.15 mV/V
2 AC Voltmeter f = 50 Hz ~ 10 kHz
32 mV ~ 320 mV 6.4 mV/V
0,32 V ~ 3,2 V 3.4 mV/V Metode Intern:
3,2 V ~ 32 V 2.2 mV/V 300/MK/05.02/LK
f = 50 Hz ~ 1 kHz Kalibrasi Voltmeter AC
32 V ~ 320 V 1.9 mV/V
320 V ~ 1050 V 1.2 mV/V
3 DC Amperemeter 0.32 mA ~ 3.2 mA 0.8 mA/A Metode Intern:
3.2 mA ~ 32 mA 0.95 mA/A 300/MK05.03/LK
32 mA ~ 320 mA 0.53 mA/A Kalibrasi Ampere Meter DC
0.32 A ~ 3.2 A 1.4 mA/A
3.2 A ~ 10 A 2.9 mA/A
4 AC Amperemeter f = 50 Hz ~ 10 kHz Metode Intern:
0.32 mA ~ 3.2 mA 0.8 mA/A 300/MK05.03/LK
3.2 mA ~ 32 mA 0.95 mA/A Kalibrasi Ampere Meter DC
32 mA ~ 320 mA 0.53 mA/A
f = 50 Hz ~ 1 kHz
0.32 A ~ 3.2 A 1.4 mA/A
3.2 A ~ 10 A 2.9 mA/A
5 Ohmmeter 4 Ω ~ 40Ω 2.9 mΩ/Ω Metode Intern:
40 Ω ~ 400 Ω 0.58 mΩ/Ω 300/MK/05.05/LK
400 Ω ~ 4 kΩ 0.41 mΩ/Ω Kalibrasi Ohmmeter
4 kΩ ~ 40 kΩ 0.5 mΩ/Ω
40 kΩ ~ 400 kΩ 0.47 mΩ/Ω
400 kΩ ~ 4 MΩ 0.87 mΩ/Ω
4 MΩ ~ 40 MΩ 2.3 mΩ/Ω

40 MΩ ~ 400 MΩ 4.2 mΩ/Ω

Notes:
Best Measurement Capability is stated as Expanded Uncertainty at approximately 95% confidence level, calculated using
coverage factor of k = 2, includes uncertainty contribution due to reference standards used by the laboratory, measurement process
at the laboratory, and contribution due to typical characteristic of nearly ideal device under calibration respective to the laboratory
The actual characteristic of device under calibration shall also be considered for individual calibration certificate issued
by the laboratory