No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
1 of 4
revision date: 25 April 2008 expiry date: 24 April 2012
PT. Global Quality Indonesia
Accreditation Number : LK-057-IDN
Address : Ruko Kopo Regency Blok N No. 7C Bandung
Telephone : 022 - 5436533
Facsimile : 022 - 5436533
Contact Person : Ir. Didi Rudi Hamid
Torque
Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
1 Hardness Durometer
type C, D, DO 0 scale ~ 100 scale 0.17 scale
type OO 0 scale ~ 100 scale 0.88 scale
2 Rockwell Machine Tester 40 HRC 0.6 HRC
50 HRC 0.6 HRC
60 HRC 0.6 HRC
Length
Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
2 of 4
revision date: 25 April 2008 expiry date: 24 April 2012
PT. Global Quality Indonesia
Accreditation Number : LK-057-IDN
Address : Ruko Kopo Regency Blok N No. 7C Bandung
Telephone : 022 - 5436533
Facsimile : 022 - 5436533
Contact Person : Ir. Didi Rudi Hamid
Electrical
Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
1 DC Voltmeter 1 mV ~ 100 mV 0.03 mV IK-22
0.1 V ~ 1V 0.3 mV
1V ~ 10 V 6 mV
10 V ~ 100 V 60 mV
100 V ~ 1000 V 600 mV
2 AC Voltmeter 1 mV ~ 100 mV 0.22 mV IK-22 f = 50 Hz & 400 Hz
0.1 V ~ 1V 1.9 mV
1V ~ 10 V 19 mV
10 V ~ 100 V 190 mV
100 V ~ 750 V 1.4 V
2 DC Amperemeter 1 mA ~ 10 mA 0.08 mA IK - 23
10 mA ~ 100 mA 0.15 mA
0.1 A ~ 1A 2.6 mA
1A ~ 3A 60 mA
3 AC Amperemeter 0.1 A ~ 1A 6 mA IK - 23 f = 50 Hz & 400 Hz
1A ~ 3A 60 mA
4 AC Clampmeter 2A ~ 250 A 1A IK - 36 f = 50 Hz
5 Ohmmeter 1 kΩ ~ 10 kΩ 50 Ω IK - 40 4 wire/ 2 wire
10 kΩ ~ 100 kΩ 500 Ω 4 wire/ 2 wire
100 kΩ ~ 1 MΩ 5 kΩ 4 wire/ 2 wire
1 MΩ ~ 10 MΩ 50 kΩ 2 wire
10 MΩ ~ 100 MΩ 500 kΩ 2 wire
6 Conductivitymeter 10 nS ~ 100 nS 0.5 nS IK - 37
100 nS ~ 1000 nS 5 nS
1 µS ~ 10 µS 50 nS
10 µS ~ 100 µS 0.5 µS
100 µS ~ 1000 µS 5 µS
1 mS ~ 10 mS 50 µS
7 Resistor/Resistance Box 1Ω ~ 10 Ω 7 mΩ IK - 41 2 wire method
10 Ω ~ 100 Ω 28 mΩ 2 wire method
100 Ω ~ 1Ω 250 mΩ 4 wire/ 2 wire
1 kΩ ~ 10 kΩ 50 Ω 4 wire/ 2 wire
10 kΩ ~ 100 kΩ 500 Ω 4 wire/ 2 wire
100 kΩ ~ 1 MΩ 5 kΩ 2 wire
1 MΩ ~ 10 MΩ 50 kΩ 2 wire
10 MΩ ~ 100 MΩ 500 kΩ 2 wire
3 DC VoltageSource 1 mV ~ 100 mV 0.02 mV IK-43
0.1 V ~ 1V 0.2 mV
1V ~ 10 V 5 mV
10 V ~ 100 V 50 mV
100 V ~ 1000 V 500 mV
4 AC VoltageSource 1 mV ~ 100 mV 0.2 mV IK-43 f = 50 Hz ~ 10 kHz
0.1 V ~ 1V 1.8 mV
1V ~ 10 V 18 mV
10 V ~ 100 V 180 mV
100 V ~ 750 V 1.3 mV
5 AC HV Source 1 kV ~ 10 kV 100 V IK 24 f = 50 Hz
6 DC Current source 1 mA ~ 10 mA 0.075 mA IK 42
10 mA ~ 100 mA 0.13 mA
0.1 A ~ 1A 2.5 mA
1A ~ 3A 50 mA
7 AC Current source 0.1 A ~ 1A 2.5 mA IK 42 f = 50 Hz ~ 1 kHz
1A ~ 3A 50 mA
3 of 4
revision date: 25 April 2008 expiry date: 24 April 2012
PT. Global Quality Indonesia
Accreditation Number : LK-057-IDN
Address : Ruko Kopo Regency Blok N No. 7C Bandung
Telephone : 022 - 5436533
Facsimile : 022 - 5436533
Contact Person : Ir. Didi Rudi Hamid
Time & Frequency
Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)
1 Spectrophotometer
Transmittance 0 %T ; 10 %T 1 %T IK -53 λ = 590 nm
50 %T ; 100 %T
Wavelength 405 nm ; 532 nm 1 nm
792 nm
2 Viscocity meter 13000 cP ; 101120 cP 1.2 %
3 pH meter 4 pH ; 7 pH 0.02 pH
Notes:
Best Measurement Capability is stated as Expanded Uncertainty at approximately 95% confidence level, calculated using
coverage factor of k = 2, includes uncertainty contribution due to reference standards used by the laboratory, measurement process
at the laboratory, and contribution due to typical characteristic of nearly ideal device under calibration respective to the laboratory
The actual characteristic of device under calibration shall also be considered for individual calibration certificate issued
by the laboratory