DINAS LABORATORIUM DEPARTEMEN TEKNIK PRODUKSI PT PUPUK SRIWIDJAJA


Accreditation Number : LK-058-IDN
Address : Jl. Mayor Zen Palembang 30118
Telephone : 0711-712111; 0711-712222
Facsimile : 0711-712100
Contact Person : Drs. Afnan Husni
Temperature

Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)

1 Liquid in glass thermometer 0 °C ~ 50 °C 0.31 °C ASTM E77: 1998


50 °C ~ 100 °C 0.37 °C
100 °C ~ 150 °C 0.41 °C

Theory and Practice of


2 Thermocouple sensor w/o indicator 0 °C ~ 900 °C 0.4 +0.18%t °C Thermoelectric Thermometry,
NML, CSIRO 1993

3 Oven 0 °C ~ 300 °C 1 °C AS 2853: 1986

4 Furnace 0 °C ~ 900 °C 2 °C

Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)

1 Weights (conventional mass) 0.001 g ~ 0.200 g 0.01 mg The Calibration of Balance


1g 0.03 mg CSIRO-NML: 1995
2g 0.04 mg
5g 0.05 mg
10 g 0.06 mg
20 g 0.08 mg
50 g 0.1 mg
100 g 0.15 mg
200 g 0.31 mg
500 g 6 mg
1000 g 6 mg
2000 g 12 mg
5000 g 24 mg
2 Balance (electronic) 0g ~ 200 g 0.5 mg
The Calibration of Balance
200 g ~ 500 g 0.7 mg
0.5 kg ~ 1 kg 2.5 mg CSIRO-NML: 1995
1 kg ~ 2 kg 11 mg
2 kg ~ 6 kg 18 mg
Volume

Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)

1 Volumetric Glassware; 0.1 ml ~ 1 ml 1 µl AS 2162-1: 1996


Volumetric Measures 1 ml ~ 5 ml 2 µl (gravimetrik)
5 ml ~ 10 ml 3 µl
10 ml ~ 25 ml 5 µl
25 ml ~ 50 ml 8 µl
50 ml ~ 100 ml 20 µl
100 ml ~ 200 ml 0.06 ml
200 ml 1000 ml 0.08 ml
1000 ml ~ 2000 ml 0.14 ml

1 of 2
Analytical Instruments

Best Measurement
No. Instrument to be calibrated Measurement Range Methods/Specifications Notes
Capability *)

1 UV-VIS Spektrofotometer
Spectral transmittance 0 %T ~ 51.6 %T 0.6 %T
Wavelength 250 nm ~ 750 nm 0.5 nm AS 3753: 1990
Technical Note 21 NATA
2 pH meter 0 pH ~ 14 pH 0.02 pH
Australia

Notes:
Best Measurement Capability is stated as Expanded Uncertainty at approximately 95% confidence level, calculated using
coverage factor of k = 2, includes uncertainty contribution due to reference standards used by the laboratory, measurement process
at the laboratory, and contribution due to typical characteristic of nearly ideal device under calibration respective to the laboratory

The actual characteristic of device under calibration shall also be considered for individual calibration certificate issued
by the laboratory