Test Detail Overall Analysis Result:


Lab Number OB2216330
Sampling Date 2022-07-15
Received Date 2022-07-25
Report Date 2022-07-26
Hours on Oil 300
Hours on Unit
MOBILGARD HSD Urgent
Oil Type
15W40
Oil Change No
STATUS URGENT Attention Urgent

Physical Test Unit Method Test Value Min | Max Min | Max
Visc@40C cSt ASTM D7279-20 94.5 | 115.5 84 | 126
Visc@100C cSt ASTM D7279-20 10.69 / CL 12.78 | 15.62 11.36 | 17.04
Visccosity Index *) - ASTM D2270-10e1
TBN mg KOH/g ASTM D2896-15 5.5 4
TAN mg KOH/g ASTM D974-21 1.52

Metal Additive Warning Limit

Magnesium (Mg) ppm ASTM D5185-18 1065


Calcium (Ca) ppm ASTM D5185-18 1291
Zinc (Zn) ppm ASTM D5185-18 1247

Contaminant
Natrium (Na) ppm ASTM D5185-18 13 60 80
Silicon (Si) ppm ASTM D5185-18 13 30 50
Fuel Dilution *) %v ASTM E2412-18
FAME Dilution *) %v ASTM E2412-18
Water Content %v ASTM E2412-18 < 0.05 0.1 0.2
G L Y C O L *) %v ASTM E2412-18 2 3

Wear Metal
Iron (Fe) ppm ASTM D5185-18 449 / C 100 200
Copper (Cu) ppm ASTM D5185-18 4 35 50
Alumunium (Al) ppm ASTM D5185-18 2 15 25
Chromium (Cr) ppm ASTM D5185-18 5 6 10
Nickel (Ni) ppm ASTM D5185-18 <1
Tin (Sn) ppm ASTM D5185-18 2
Lead (Pb) ppm ASTM D5185-18 30 / C 5 10
PQ Index *) - PQ Analyzer 85 180

FTIR Warning Limit

Soot Abs/cm ASTM E2412-18 0 0


Oxidation Abs/cm ASTM E2412-18 <1 20 40
Nitration Abs/cm ASTM E2412-18 <1 20 40
Sulfation Abs/cm ASTM E2412-18 <1 20 40

Others Parameters
Magnetic Plug Rating NA

Source of Abnormality
HASIL ANALISA URGENT. Ausan metal Fe dan Pb tinggi, kemungkinan ausan bersumber dari Bearings, Gears, shaft, housing, Oil Pump. Viskositas pelumas diukur pada
suhu @100C Cukup encer. Indikasi kontaminan, high temp, degradasi.
Action to be Taken
Perhatikan trend kenaikan kontaminan dan ausan. Perhatikan level, dan temperature kerja component. Periksa operasional yang abnormal. Pastikan tidak terjadi
kontaminan dengan pelumas yang lebih encer. Perhatikan kebersihan tool sampling dan cara pengambilan sampel. Lanjutkan sampling pada jadwal service berikutnya.

*) Tidak termasuk ruang lingkup akreditasi

Note:
- Data analisa hanya berlaku untuk sample yang di uji di laboratorium PT. Petrolab Services
- Report tidak boleh digandakan tanpa persetujuan tertulis dari laboratorium
- Laboratorium PT. Petrolab Services tidak bertanggung jawab terhadap kegiatan sampling
Lube and Fuel Laboratory Consultant
PT PETROLAB SERVICES
Jl. Jend Sudirman No. 874 Komp. UT Stalkuda Balikpapan 76114
Telp 0542-762873 fax. 0542-765019; petrolab@cbn.net.id; www.petrolab.co.id No. 16330/BPN/07/22

Disetujui

Reko Sayogo, S.Si

You might also like