You are on page 1of 1

Reference: VISP-NDT-008-A

Velosi Integrity & Safety Pakistan Page: 1 of 2

Pvt. Ltd Rev. no: 00

ULTRASONIC EXAMINATION A-SCAN REPORT


ULTRASONIC A-SCAN Report No :
Client MPCL Date 4/9/2022

Drawing No. 2981-CMF-2-L1-001 Calibration Block V2 & Step Wedge

Line No. 12" EFL-III Meter Run Reference Code ASME Section V

Location CMF 2,MPCL Dahrki Field Couplant Gel

Material Pipe=ASTM A-106 Gr B, Fittings=A234 Gr-WPB Scanning Technique Pulse Echo

Surface Condition Painted Overlap 10%

Reference Code: ASME Section V Acceptance Criteria : ASME B31.3


Scan Plan
Search Units Sensitivity (Db)
Element size Echoes Height
Sr.# Freq MHz Probe Model Wave Type Wave Angle Gain (Db)
(mm)
1 5 D7906-SM 10 Longitudinal 0˚ 33 80%

Evaluation
Grid Minimum Thickness in Millimeter (mm) Remarks
Sr. # Grid No. Grid Description
Minimum Design
12 to 3 O'clock 3 to 6 O'clock 6 to 9 O'clock 9 to 12 O'clock Metal Loss
Thickness Thickness
1 1 0.00 - -
2 2 0.00 - -
3 3 0.00 - -
4 4 0.00 - -
5 5 NA 0.00 - -
6 6 0.00 - -
7 7 0.00 - -
8 8 0.00 - -
9 9 0.00 - -
10 10 Pipe 12" 12.17 12.36 12.09 12.47 12.09 - -
11 11 Elbow 12" 11.73 12.27 12.31 12.66 11.73 - -
12 12 Pipe 12" 12.49 12.11 12.47 12.63 12.11 - -
13 13 Pipe 12" 12.57 12.68 12.41 12.29 12.29 - -
14 14 Pipe 12" 14.37 15.01 14.73 14.83 14.37 - -
15 15 Pipe 12" 14.78 14.46 14.37 14.67 14.37 - -
16 16 Reducer 16 x 12 9.68 9.73 9.89 10.59 9.68 - -
17 17 Pipe 16" 13.37 13.47 13.54 14.63 13.37 - -
18 18 Pipe 16" 14.27 14.17 14.39 13.98 13.98 - -
19 19 Pipe 16" 12.97 12.27 13.39 13.27 12.27 - -
20 20 Pipe 16" 13.37 13.78 12.67 13.01 12.67 - -
21 21 Pipe 16" 14.97 14.67 13.72 13.26 13.26 - -
22 22 Pipe 16" 14.37 13.64 14.54 14.31 13.64 - -
23 23 Reducer 16 x 10 7.82 7.98 7.95 7.62 7.62 - -
24 24 Pipe 10" 11.95 11.84 11.81 11.99 11.81 - -
25 25 Pipe 10" 11.89 11.77 11.94 11.87 11.77 - -
26 26 Pipe 10" 12.00 11.97 11.66 11.84 11.66 - -
27 27 Pipe 10" 11.79 11.89 11.92 11.77 11.77 - -
28 28 Elbow 10" 11.45 11.94 12.19 11.70 11.45 - -
29 29 Elbow 10" 12.63 11.90 11.48 11.92 11.48 - -
30 30 Pipe 10" 12.34 12.51 12.63 12.72 12.34 - -
Remarks: 01). 100% Scanning of fittings &100% Scanning at HAZ area of pipe lengths done of above items.
02). For thickness Monitoring Location kindly refer to attached drawing

Prepared By Reviewed By Approved By


Name: Waleed Ahmed & M.Danish Zia Name: Irfan Ahmed Khan Name: Muhammad Kamran Ibrahim