You are on page 1of 5

PROVISION OF RISER CORROSION PREVENTION

SYSTEM AND MAINTENANCE FOR PCSB PMA – BSDPA

RISER MAINTENANCE 2022

SCOPE OF WORK WITH SURFACE AREA ESTIMATION

No DESCRIPTION PHOTO Scope Of Work


Finding:
General Rusting

Paint Chalking
Others:
Recommendation:

1 Barrel Door Power Tools ST 3.0

Painting: 1C system

Surface area estimation: 0.5


m2

Finding:
General Rusting

Pin point Rusting

Recommendation:
2. Riser clamp
Power Tools ST 3.0

Painting: 4B system

Surface area estimation:


2.5m2
PROVISION OF RISER CORROSION PREVENTION

SYSTEM AND MAINTENANCE FOR PCSB PMA – BSDPA

RISER MAINTENANCE 2022

Finding:
General Rusting

Spot Rusting

Pin point Rusting


Below riser
3. clamp and riser Others
clamp arm Recommendation:
Power Tools ST 3.0

Painting: 4B system
Surface area estimation:
2.5m2

Finding:
General Rusting

Pin point Rusting

Others:
Other view of
4.
riser clamp Recommendation:
Power Tools ST 3.0

Painting: 4B system

Surface area estimation:


2.5m2
PROVISION OF RISER CORROSION PREVENTION

SYSTEM AND MAINTENANCE FOR PCSB PMA – BSDPA

RISER MAINTENANCE 2022

BSDPA STRUCTURE SCOPE OF WORK

Finding:
General Rusting

Spot Rusting

Riser Guard Pad


1. Recommendation:
Eye
Power Tools ST 3.0

Painting: 4B system

Surface area estimation: 9.0


m2

Finding:
General Rusting

Spot Rusting

Riser Guard Pad Recommendation:


2.
Eye
Power Tools ST 3.0

Painting: 4B system

Surface area estimation:


9.0m2
PROVISION OF RISER CORROSION PREVENTION

SYSTEM AND MAINTENANCE FOR PCSB PMA – BSDPA

RISER MAINTENANCE 2022

Finding:
General Rusting

Spot Rusting

Corrosion at Recommendation:
3. Boat Landing
Power Tools ST 3.0
support, clamp
and flange Painting: 4B system

Surface area estimation:


12.0m2

Finding:
General Rusting

Spot Rusting

4. Corrosion at Recommendation:
conductors
Power Tools ST 3.0

Painting: 4B system

Surface area estimation:


11.3m2
PROVISION OF RISER CORROSION PREVENTION

SYSTEM AND MAINTENANCE FOR PCSB PMA – BSDPA

RISER MAINTENANCE 2022

Finding:
General Rusting

Spot Rusting

Others: Oil staining


Corrosion at
5. Recommendation:
conductors
Power Tools ST 3.0

Painting: 4B system

Surface area estimation: 11.3


m2

You might also like