You are on page 1of 7

SEIP for 089-H-001

Contents

General Section Unit Item No. Name Ranking Installation Maker Government compliance

2 089 / SRU 089-H-001 INCINERATOR - 2014 - Vietnam

Temperature(℃) Pressure(kPag) Material / Wall thickness ( mm )


Firing Zone Residence Zone Firing Zone Residence Zone Shell/Head Tube
Specification
Design Operation Design Operation Design Operation Design Operation Material Nominal MAT Material Nominal MAT
A516
1600 350 - 350 - - - 25/25 12.23/12.23 N/A N/A N/A
Gr.60N
Type Related area Risk level Remark Type Related area Risk level Remark
Refractory
Shell L - - - - -
Damage Degradation,
Mechanism Creep/stress rupture Shell L If refractory damage - - - -
Oxidation Burner N/A - - - - -
Dew Point Corrosion
Shell L - - - - -
Sulfidation corrosion,
Inspection Inspection Area selection
Item Insepction area Method Purpose Remarks
interval volume Fixed IP Point
Every
Shell VI Fouling, Corrosion All - - DCSM
openning
Inspection
Criteria / Every
Burner VI Fouling, Corrosion All - - DCSM
Method openning
Visual inspection
Every
Nozzle VI Fouling, Corrosion All - - DCSM
openning
Every
Refractory &Brick VI Damage All - - DCSM
openning
Item Content

Damage History
Remarks
None Inspection Area

Others

Prepared by Review by Approved by


Heater

089-H-001 Inspection Record

1. General
Item No : 089-H-001 INCINERATOR Inspection Date : …./…../2019

2. External Inspection [Legend] G (good), R (not good), N (none)


Casing Painting Foundation Grounding
Ladder Cage Platform Name Plate Stack
Expansion
Air Duct Gas Duct Others
Joint

Remark

3. Internal Inspection (Visual / Thickness/ Tube OD) [Legend] V (Severe), M (Moderate), S (Slight), N (Negligible)

Radiant Section Hip Section Convection Sec. Remarks


Refractory □ Good □ Good □ Good
□ Bad □ Bad □ Bad

Gas Tip Pilot Tip Regen Tile Burner Tile Remarks


Burner □ Good □ Good □ Good □ Good
□ Bad □ Bad □ Bad □ Bad

Visual inspection:
Area Part Result & finding Remark

Corrosion (scale,
pits, build-up).
Describe location,
appearance, and
depth.
FITTINGS
(Support, Distortion
hangger)
Condition of tube
roll, plug and threads

Weld condition

Insulation, refractory

Insulation clips

Fire brick

Burner view port


CASING
AND Convection section
INTERNALS
Thermowells

Floor plate condition

Casing condition

Condition of external
coating

Page 2
Corrosion (scale,
pits, build up).
Describe location,
appearance, and
depth

Thermocouple
BURNER condition
ASSEMBLY
Inlet guide shroud

Burner tile condition

Flame appearance

External condition

Condition of bolts

Internal Insulation,
refractory, coating
STACK
ASSEMBLY Guy wire supports
(FLUE GAS)

Condition of damper

Rain cap

Coating

Condition of
FOUNDATIO concrete supports
N AND
SUPPORTS Condition of
structure steel
Condition of blower
motor
BLOWER
Condition of impeller

Others -

Remark

4. NDE
Part Part ID Method Judgment Part Part ID Method Judgment

5. Sample / Replica inspection : □ Action □ No action

6. Repair work

7. Recommendation

8. Attachment

Recommended next opening : Prepared by Reviewed by Approved by

Purpose : ■ Cleaning, ■ Inspection

Page 3
1. Refractory lining condition shall be checked by VI, especially for top ceiling section not to miss finding out refractory
bulge downward.
2. All of the Internal parts of burner shall be inspected for deformation,corrosion.

Note; 2 M/Hs in 089-H-002 are common to access this 089-H-001, Main Burner.
Inspection for External corrosion will be carried out during operation.

1. External Inspection

2. Internal Inspection
1. External Inspection

2. Internal Inspection
2.1 Fouling Condition

2.2 Corrosion

2.3 Internal Part Condition

4. Repair Works

5. Recommendation

1. External Inspection

2. Internal Inspection
2.1 Fouling Condition

2.2 Corrosion

2.3 Internal Part Condition

3.Wall Thickness Measurement


3.1 Head

3.2 Shell

4. Repair Works

5. Recommendation
4. Repair Works

5. Recommendation
Photo Record of 089-H-001

1. Location

2. Result

1. Location

2. Result

1. Location

2. Result

You might also like