You are on page 1of 3

TEST REPORT

No. : SZIN1512013453ML
Date : Jan 05, 2016
Page: 1 of 3

CUSTOMER NAME: LIVART MARINE INDUSTRY CO., LTD


ADDRESS: RM413 B, BLOCK OF HENGYU CENTER, NO.21 DENGLIANG ROAD,
NANSHAN DISTRICT, SHENZHEN, GUANGDONG ,CHINA

The following sample(s) was/ were submitted and identified on behalf of the client as:
Sample Name : WELD STRENGTH
Date of Receipt : Dec 29, 2015
Testing Start Date : Dec 29, 2015
Testing End Date : Jan 05, 2016
Test result(s) : For further details, please refer to the following page(s)

Signed for
SGS-CSTC Standards Technical
Services Co., Ltd. Shenzhen Branch
Testing Center

Wendy Liu
Authorized signatory
TEST REPORT
No. : SZIN1512013453ML
Date : Jan 05, 2016
Page: 2 of 3

1. Tensile Test:
Test Method: ISO 4136-2012
Width×Thickness Maximum force Tensile strength
Specimen Fracture location
(mm) (kN) (MPa)
1# 24.95ˣ10.05 31.18 124 Weld metal

Test Photo:

Tested sample Tested sample(Local part)

2. Macro/micro Examination:
Reference standard: BS EN ISO17639-2013 & ISO 15614-2:2005 and client’s requirement
Defects of the samples
Specimen Crack Porosity Inclusion Lack of fusion Incomplete penetration
1# No No NO No No
Not d≤0.2s l≤0.2a
Req. Not permitted Not permitted
permitted Max.4mm Max.3mm
1# Pass Pass Pass Pass Pass
Note: 1. “No” means that no defects were observed; “Yes” means that defects were observed.
2. The results comply with the requirement of ISO 10042-2005 level B
TEST REPORT
No. : SZIN1512013453ML
Date : Jan 05, 2016
Page: 3 of 3

Test Photo:

Original Sample Photo:

******** End of report********