Professional Documents
Culture Documents
engineeringcivil.com/advanced-earthquake-resistant-techniques.html
December 7, 2021
Earthquakes are one of the most devastating forces on the planet. The seismic waves
that travel through the ground can demolish buildings, kill people, and cost billions of
dollars in damage and restoration. According to the National Earthquake Information
Center, there are over 20,000 earthquakes every year on average, including 16 major
disasters. The damage was caused by the collapse of buildings with people inside, as in
previous earthquakes, prompting the development of earthquake-resistant constructions.
Shock Absorption – –
Similar to the shock absorbers found in automobiles, structures employ this technology.
This earthquake-resistant technology aids in the slowing down and reduction of the
magnitude of vibrations in buildings. Shock absorbers should ideally be installed at each
level of the structure, with one end attached to the beam and the other to the column.
Each consists of a piston head that operates inside a silicone oil-filled cylinder. The
horizontal motion of the building during an earthquake causes the piston to push against
the oil, converting mechanical energy from the quake to heat.
1/6
Flexible Foundation –
Base isolation allow the building to be placed atop flexible pads that separate the
foundation and allow the building to move in place. One technique to withstand ground
stresses is to raise the foundation of the building above the ground. Here, in this case,
the isolators vibrate as the base moves during an earthquake, but the structure itself
stays stable. This effectively absorbs seismic vibrations and prevents them from passing
through a structure.
Rocking-Core Wall –
Modern high-rise buildings use the rocking core-wall technology to improve seismic
protection at a reasonable cost. A reinforced concrete core is established through the
heart of the structure, encircled by elevator banks, to make this work. This approach is
used in many modern high-rise structures to boost seismic resilience in a cost-effective
manner. When used in conjunction with base isolation, it is the most successful
technique compared to other techniques. Elastometric bearings use alternating layers of
steel and natural rubber/neoprene for base isolation. The resulting bearing has a low
horizontal stiffness and a high vertical rigidity. The combination is highly effective, cost-
efficient, and easy to use.
2/6
Building Stability
Buildings must redistribute the forces that pass through them during a seismic event to
avoid collapsing. Reinforcing a structure requires the use of shear walls, cross braces,
diaphragms, and moment-resisting frames. In addition, shear walls are a valuable
construction technique for transferring earthquake forces which is mentioned in IS
13920:2016. These walls, which are made of panels, allow a building maintain its shape
during movement. Also, diagonal cross bracing are frequently used to support shear
walls. These steel beams can support compression and tension, which helps to relieve
pressure and redirect forces back to the foundation. Diaphragms are an important
feature of the structure of a building as they help release tension from the floor and push
force to the building’s vertical structures. They are made up of the building’s floors, roof,
and decks placed over them. Moment-resisting frames allow for greater design flexibility
while building a structure. This framework is installed between the building’s joints and
allows the columns and beams to flex while the joints remain stiff. As a result, the
structure can withstand the greater forces of an earthquake while also giving designers
more flexibility in how they arrange the building’s elements.
This new technology for strengthening building relies on damping and energy dissipation
as well, but it greatly extends the damping and energy dissipation given by lead-rubber
bearings. Earthquake ground motion transfers a certain amount of vibration energy to
the building. Buildings have the power to disperse, or dampen, this energy on their own.
Buildings also have a finite ability to disperse energy before deformation and destruction
occur. This will release energy either through large-scale movement or increasing
internal strains in structural parts such as columns and beams. Both of them eventually
cause damage of differing degrees. As a result, by installing a building with additional
high-damping-capacity devices, we may considerably reduce the seismic energy
entering the structure and thereby reduce structural damage. As a result, a range of
energy dissipation devices have been created and are now being used in real-world
buildings. Damping devices are another name for energy dissipation devices. Many
dampening devices that have been created can be classified into three categories:
friction dampers: that dissipate energy by using frictional forces; metallic dampers: that
rely on metal parts within the damper to deform; and viscoelastic dampers: that use
controlled shearing of solids.
3/6
Courtesy: Roadjz.com
Pendulum Power –
This approach works by suspending a massive mass near the structure’s top. Steel
cables support the mass, and viscous fluid dampers are installed between the mass and
the structure that it protects. In the event of seismic activity, the pendulum swings in the
opposite direction to restore equilibrium. These systems are known as tuned mas
dampers because each of the pendulums is tuned to match the structure’s inherent
frequency. Their purpose is to diminish the dynamic response of the structure by
counteracting resonance.
4/6
Conclusion
Seismic engineering is a
sophisticated and ever-changing
field. Seismic structural evaluation is
a powerful method in Earthquake
Engineering that combines thorough
modelling of the structure with
structural analysis to determine the
building’s resistance to earthquakes.
It’s just as necessary to upgrade
older structures with better designs
or materials as it is to build new
structures from the ground up.
Earthquake Civil Engineering’s
ultimate purpose is to preserve lives
by preventing buildings from
collapsing and allowing residents to
flee in a timely way. Also, other
relevant earthquake design codes
for earthquake resistant construction
masonry structures have been
produced by the BIS (Bureau of
Indian Standards) in addition to the
main earthquake design code 1893
(IS-13828 1993). Hence, engineers
must follow these guidelines for better understanding and designing of structures
especially in earthquake prone areas.
References
Kanwarjot Singh
Kanwarjot Singh is the founder of Civil Engineering Portal, a leading civil engineering
website which has been awarded as the best online publication by CIDC. He did his BE
civil from Thapar University, Patiala and has been working on this website with his team
of Civil Engineers.
Related Posts
5/6
If you have a query, you can ask a question here.
Leave a Reply
Your email address will not be published. Required fields are marked *
6/6