Professional Documents
Culture Documents
Note: so far the system does not allow the printing of the fault code summary. A new
software is under development
• EEC replacement
• MFCU replacement
• rigging of HMU/PVM
• PLA push/pull cable adjustment or replacement
2
Elaborated by Julio.Simões
EEC ATR 72-212A
EEC LRU:
….. AT T/O TQ INDICATED WILL NOT MATCH TQ BUG HMU, O/SPEED GOV, Py TUBE,
HARNESS, A/C WIRING
….. POSSIBLE TQ SPLIT, POSSIBLE DEGRADE ENGINE EEC AND ADC / WIRING
….. NOISY ENGINE OR SURGING AT ACCELERATION HBV FILTER, HBV
5
Elaborated by Julio.Simões
72-00-03 ENGINE (PW127) - FAULT ISOLATION
Elaborated by Julio.Simões
72-00-03 ENGINE (PW127) - FAULT ISOLATION
Elaborated by Julio.Simões
72-00-04 ENGINE (PW127E) - FAULT ISOLATION
Elaborated by Julio.Simões
72-00-04 ENGINE (PW127E) - FAULT ISOLATION
Elaborated by Julio.Simões
LRU Fault Code Figure Fault Description
- 174 Engine Power Increases asPropeller is Feathered
96 175 DCU 1 (or 2) Inoperative
Elaborated by Julio.Simões
72-00-05 ENGINE (PW127F) - FAULT ISOLATION
Elaborated by Julio.Simões
72-00-05 ENGINE (PW127F) - FAULT ISOLATION
Elaborated by Julio.Simões
72-00-06 ENGINE (PW127M) - FAULT ISOLATION
Elaborated by Julio.Simões
72-00-06 ENGINE (PW127M) - FAULT ISOLATION
Elaborated by Julio.Simões
72-00-01 ENGINE PW124B/127/127E/127F/127M - FAULT ISOLATION
The actions required to locate and rectify problems with the engine are detailed in the following figures.
FAULT FIGURE
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
C26345
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
CONT’D ON
SHEET 2
C26340
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
C26341
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
YES
YES
CONT’D ON
SHEET 4
C26342
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 3
YES
C26343
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
ENGINE NO. 2 UPTRIM LAMP ON WHEN SYSTEM NORMAL
TEST SWITCH NO. 1 RELEASED ?
NO
YES
NO
NO
NO
C26344
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NO REPLACE MFCU
REVERSION SYSTEM OK ?
(REF. 72−01−40)
YES
SYSTEM NORMAL
C26339
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
REPLACE EEC
(REF. 72−01−10)
C26338A
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
CHECK ENGINE HARNESS NO REPAIR/ REPLACE
INSULATION RESISTANCE: HARNESS
P2−X, P2− v TO ALL OTHER (REF. 72−01−10)
PINS AND BACKSHELL ON
REPAIR/ REPLACE CONNECTOR P2 GREATER
AIRCRAFT WIRING THAN OR EQUAL TO 2
(REF. AMM) MEGOHMS AT 45 VDC. OK ?
C26337
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26336
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
C26335
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION YES
PLUG (REF. 72−01−10) SYSTEM NORMAL
OK?
NO
REPLACE EEC
(REF. 72−01−10)
OK?
YES
SYSTEM NORMAL
C37697
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26334
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR
TURN EEC OFF. DISCONNECT
IS ECS BLEED NO NO AIRCRAFT
P2. VOLTAGE AT P2− h AND
SELECTED ? WIRING
P2−C TO GROUND ZERO VDC ?
(REF. AMM)
YES YES
C26333
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
AIRCRAFT OUT OF CROSSWIND ? REORIENT AIRCRAFT
YES
C26332
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
ENGINE BLEEDS ARE OFF CLOSE ENGINE BLEEDS
YES
INVESTIGATE PERFORMANCE
DETERIORATION (REF. ENGINE
NO
P2.5 AND/ OR P3 AIR LEAKS ? −FAULT ISOLATION,
PERFORMANCE DETERIORATION
(ECTM SHIFT) OR HIGH ITT (T6)
YES
C26331
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO REPLACE ELECTRICAL
CHECK CONTINUITY: LINE 100 LESS
HARNESS
THAN OR EQUAL TO 0.5 OHMS ?
(REF. 72−01−10)
YES
NO REPLACE ELECTRICAL
CHECK CONTINUITY: LINE 101 LESS
HARNESS
THAN OR EQUAL TO 0.5 OHMS ?
(REF. 72−01−10)
YES
YES
YES
C26330
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO REPLACE ELECTRICAL
CHECK CONTINUITY: LINE 104 LESS
HARNESS
THAN OR EQUAL TO 0.5 OHMS ?
(REF. 72−01−10)
YES
NO REPLACE ELECTRICAL
CHECK CONTINUITY: LINE 102 LESS
HARNESS
THAN OR EQUAL TO 0.5 OHMS ?
(REF. 72−01−10)
YES
YES
YES
C26329
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO REPLACE ELECTRICAL
CHECK CONTINUITY: LINE 103 LESS
HARNESS
THAN OR EQUAL TO 0.5 OHMS ?
(REF. 72−01−10)
YES
NO REPLACE ELECTRICAL
CHECK CONTINUITY: LINE 102 LESS
HARNESS
THAN OR EQUAL TO 0.5 OHMS ?
(REF. 72−01−10)
YES
YES
YES
C26328
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE WIRING
CHECK CONTINUITY: LINE 160 LESS NO
HARNESS
THAN OR EQUAL TO 0.5 OHMS ?
(REF. 72−01−10)
YES
YES
C26327
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO REPAIR AIRCRAFT
IS AIRCRAFT RELAY OK (REF. AMM) ?
WIRING (REF. AMM)
YES
YES
C26325
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
C26326
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO REPAIR/ REPLACE
APPLY 28VDC TO P11−AA ( + ) AND P11− b
AIRCRAFT WIRING
( − ). MANUAL LAMP OFF ?
(REF. AMM)
YES
YES
YES
CONT’D ON
SHEET 2
C26322
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
YES
REPLACE EEC
(REF. 72−01−10)
NOTE : THE VOLTAGE SUPPLIED BY THE EEC TO THE FAIL FIXED RELAY, MFCU STEPPER MOTOR AND
IBV TORQUE MOTOR COMES FROM THE SAME DRIVER. THEREFORE, A SHORT CIRCUIT TO
GROUND ON ANY ONE OF THESE CIRCUITS WILL RESULT IN FAULT CODE 85 BEING SET.
C26323A
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
C26324
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 103, NO
HARNESS
104, 128 AND 129 LESS THAN 0.5 OHM?
(REF. 72−01−60)
YES
YES
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO PREVIOUS FAULT
CODES ARE SET FOR ANY OF THE NH PROBES AND THE DIFFERENCE BETWEEN THE TWO
READINGS EXCEEDS 0.9%.
C26399
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NO REPLACE NH
IS CONTINUITY OF NH SENSOR NO. 2, J5−3
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE) ?
(REF. 72−01−60)
YES
C26321
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NO REPLACE NH
IS CONTINUITY OF NH SENSOR NO. 1, J14−3
SENSOR NO. 1
TO J14−4, 36 TO 45 OHMS (COIL RESISTANCE) ?
(REF. 72−01−60)
YES
C26320
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
YES
NO REPLACE NH
IS CONTINUITY OF NH SENSOR NO. 2 J5−3
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE) ?
(REF. 72−01−60)
YES
C26319
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
YES
NO REPLACE NH
IS CONTINUITY OF NH SENSOR NO. 1 J14−3
SENSOR NO. 1
TO J14−4 36 TO 45 OHMS (COIL RESISTANCE) ?
(REF. 72−01−60)
YES
C26318
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHECK CONTINUITY: LINES 112, 113 AND NO ELECTRICAL
114 LESS THAN OR EQUAL TO 0.5 OHMS ? HARNESS
(REF. 72−01−10)
YES
YES
YES
YES
C26317
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHECK CONTINUITY: LINES 117, 118 AND NO ELECTRICAL
119 LESS THAN OR EQUAL TO 0.5 OHMS ? HARNESS
(REF. 72−01−10)
YES
YES
YES
YES
C26316
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
C26315
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO REPLACE EEC
NP EXCEEDED 135% (REF. 72−01−10)
YES
FOLLOW APPROPRIATE
MAINTENANCE ACTION
FOR NP OVERSPEED
(REF. 05−50−00)
C26314
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
NO
(REF. 72−01−10). TORQUE SHAFT OK ?
FAULT CLEARS ?
YES NO
REPLACE ENGINE
SYSTEM NORMAL (REF. AMM)
C26313
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
NO
(REF. 72−01−10). TORQUE SHAFT OK ?
FAULT CLEARS ?
YES NO
REPLACE ENGINE
SYSTEM NORMAL (REF. AMM)
C26312
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
NO
(REF. 72−01−10). TORQUE SHAFT OK ?
FAULT CLEARS ?
YES NO
REPLACE ENGINE
SYSTEM NORMAL (REF. AMM)
C26311
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
IS CONNECTOR P1 SECURELY NO
RECONNECT P1 TO EEC
MATED TO J1 ?
YES
YES
SYSTEM NORMAL
C26310
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NOTE: SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING OUT OF FEATHER SINCE
ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
C26309
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NOTE: SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING OUT OF FEATHER SINCE
ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
C26308
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING OUT OF FEATHER SINCE
ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
C26307
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING OUT OF FEATHER SINCE
ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
C26306
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
SYSTEM NORMAL
NOTE: SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING OUT OF FEATHER SINCE
ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
C26305
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONT’D ON
SHEET 2
C26303
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
NOTE: SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING OUT OF FEATHER SINCE
ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
C26304
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
34 UART (UARTIF)
REPLACE EEC
(REF. 72−01−10)
C26302
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
SYSTEM NORMAL
C26301
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26300
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
29 Q2 BIAS (TBTIF)
YES
REPLACE CHARACTERIZATION
CHECK RESISTANCE: C TO D WITHIN NO PLUG WITH RESISTOR VALUES
± 1.0% OF VALUE SHOWN ON PLUG R3 AND R4 AS PER DATA
DATA PLATE (R3) ? PLATE (REF. 72−01−10)
YES
YES
C26299A
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
28 Q2 GAIN (TGTIF)
YES
YES
REPLACE CHARACTERIZATION
CHECK CONTINUITY: PIN C OF PLUG NO PLUG WITH RESISTOR VALUES
TO ALL OTHER PINS AND BACKSHELL
R3 AND R4 AS PER DATA
GREATER THAN 2 MEGOHMS AT 45 VDC ?
PLATE (REF. 72−01−10)
YES
C26298A
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26297
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26296
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26295
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26294
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26293
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26292
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26291
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO RECTIFY OR REPLACE
ADC OK ?
PER FAULT CODE 53
YES
SYSTEM NORMAL
C26290
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
NO
SYSTEM NORMAL
C26289
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
SYSTEM NORMAL
C26286
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
PROPELLER COMES OUT OF FEATHER WHEN NO CHECK HIGH PRESSURE OIL PUMP,
CONDITION LEVER MOVED TO UNFEATHER PROPELLER AND PROPELLER
POSITION ? CONTROL UNIT (REF. AMM)
YES
YES
YES
CONT’D ON
SHEET 2
C26284
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
NOTE: FAULT CODE LRU 10 IS SET IF THE FOLLOWING CONDITIONS HAVE EXISTED
FOR A PERIOD EXCEEDING 20 SECONDS:
C26285
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26283
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26288
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26287
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26334
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
POST−SB21182
PRE−SB21213
211
201
191
201 171
180A
A
PRE−SB20854
100
90
SEE DETAIL B
SHEET 3
PRE−SB21182
210
30
190 200 20
200
170
180
10
11
30
240 230 250 260 50
220
20
70
40 60
80
VIEW A
C50009B
Printed on: 08 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
POST−SB20854
165 162
A
167
163
30
211A 20
191 191 201
201
180A
201
171A
11A
POST−SB21213
30
50
20
240
260 250
230A
70
220
40 60
80
VIEW A
C50103B
Printed on: 08 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
90
100
140
150A
160
130
120
110
DETAIL B
C50104A
Printed on: 08 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
YES
SYSTEM NORMAL
C26346
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26334
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
149
CD Issue Date: 21 JAN/10
NO
YES
YES
SYSTEM NORMAL
C26346
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões 158
CD Issue Date: 21 JAN/10
YES
C26345
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões 157
CD Issue Date: 21 JAN/10
NO
NO
NO
CONT’D ON
SHEET 2
C26340
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement 156
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
C26341
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
YES
YES
CONT’D ON
SHEET 4
C26342
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 3
YES
C26343
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
ENGINE NO. 2 UPTRIM LAMP ON WHEN SYSTEM NORMAL
TEST SWITCH NO. 1 RELEASED ?
NO
YES
NO
NO
NO
C26344
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NO REPLACE MFCU
REVERSION SYSTEM OK ?
(REF. 72−01−40)
YES
SYSTEM NORMAL
C26339
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões 155
CD Issue Date: 21 JAN/10
YES
YES
YES
REPLACE EEC
(REF. 72−01−10)
C26338A
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement 154
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
CHECK ENGINE HARNESS NO REPAIR/ REPLACE
INSULATION RESISTANCE: HARNESS
P2−X, P2− v TO ALL OTHER (REF. 72−01−10)
PINS AND BACKSHELL ON
REPAIR/ REPLACE CONNECTOR P2 GREATER
AIRCRAFT WIRING THAN OR EQUAL TO 2
(REF. AMM) MEGOHMS AT 45 VDC. OK ?
C26337
153
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26336
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement 152
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
C26335
Printed on: 09 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
C26406
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULT CODES FOR THE
COILS ARE SET AND THE DIFFERENCE BETWEEN THE TWO NPT COIL READINGS EXCEEDS 5%.
C26393
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR / REPLACE
CHECK HARNESS. IS CONTINUITY ON LINES NO
HARNESS
105, 106, 110 AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULTS ARE SET FOR
ANY COILS AND THE DIFFERENCE BETWEEN THE TWO TORQUE COIL READINGS EXCEEDS 5%.
C26392
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26384
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26383
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26382
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26381
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26435
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT IS SET IF THE FOLLOWING TORQUE LEVELS ARE MAINTAINED FOR THE CONTINUOUS
PERIODS INDICATED:
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26434
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT OCCURS WHEN THE ENGINE TORQUE IS BETWEEN 122% AND 137% (12800 −14440
LB. FT. ) FOR A CONTINUOUS PERIOD OF TIME GREATER THAN 20 AND LESS THAN 3000 SECONDS,
OR WHEN THE ENGINE TORQUE IS BETWEEN 100% AND 122% (10504−12800 LB. FT.) FOR A
CONTINUOUS PERIOD OF TIME GREATER THAN 600 SECONDS.
C26433
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26373
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE WITH
NO
HAS A PW127F MFCU BEEN INSTALLED? CORRECT MFCU
(REF. 72−01−40)
YES
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 124 NO
ENGINE HARNESS
AND 125 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE EEC DOES NOT ACKNOWLEDGE CONTINUITY BETWEEN PINS J2− a
AND J2−D OF THE MFCU. THE PW127, PW127E AND PW127F MFCU’s PROVIDE HIGHER FLOWS
FOR OPERATION AT PW127, PW127E AND PW127F POWERS THAN THE PW124B MFCU.
THESE CONNECTED PINS WITHIN THE MFCU ARE A WAY FOR THE EEC
TO IDENTIFY A PW127, PW127E AND A PW127F MFCU.
C26432A
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THE INDICATION TO THE EEC COMES FROM A RANGE CHECK PERFORMED ON
THE OUTPUT WRAPAROUND CIRCUITRY.
REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON NO
ENGINE HARNESS
LINES 112 AND 113 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE EEC
(REF. 72−01−10)
C26431B
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DELTA−P PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26427
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
C26354A
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
THIS FAULT IS CAUSED BY A DUAL NH FAILURE AND THE MAINTENANCE PROCEDURE FOR
LRU 12 IS TO BE FOLLOWED.
THIS FAULT SENDS A "DASH−DASH" OUTPUT TO THE COCKPIT ON ARINC LABEL 343 TO TELL
THE PILOT THAT THE INTERCOMPRESSOR BLEED VALVE IS NOT OPERATIONAL.
C26420
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SET CONDITION
LEVER AT FUEL CUTOFF
POSITION. TURN EEC
POWER OFF. REMOVE YES REPLACE
CONNECTOR P2 FROM EEC
EEC. ARE THERE 28 VDC
ON P2 − s OF ENGINE
HARNESS?
NO
CHECK CONTINUITY.
ENGINE HARNESS NO REPAIR / REPLACE
LINE 134 LESS ENGINE
THAN OR EQUAL TO HARNESS
0.5 OHM?
YES
YES
INVESTIGATE
AIRCRAFT WIRING.
ARE THERE 28 VDC NO
ON ENGINE HARNESS RECTIFY
DISCONNECT P11 − j
WHEN PROPELLER IS
FEATHERED?
YES
SYSTEM NORMAL
C26419
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement 174
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
INVESTIGATE
AIRCRAFT WIRING TO YES SYSTEM
PLA ENABLE
NORMAL
MICROSWITCHES
(REF. AMM). OK?
C26418
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
173
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
CONTINUED ON SHEET 2
C26414
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement 172
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
C26341
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
YES
CONTINUED ON SHEET 4
C26415
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONTINUED ON SHEET 4
YES
REPLACE AIRCRAFT
TORQUE INDICATOR
(REF. AMM)
C26416
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NO
NO
C26417
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26412
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões 170
CD Issue Date: 21 JAN/10
C26411
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
DUAL AIRSPEED INPUT FAULT
(IASIF)
SYMPTOMS SUSPECT LRU
POSSIBLE TORQUE SPLIT 1. EEC AND
POSSIBLE DEGRADE ENGINE AND PROPELLER 2. ADC
PERFORMANCE 3. WIRING
LRU 19
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT IS SET WHEN BOTH ARINC AIRSPEED INPUT FAULT (LRU = 54) AND DELTA
P SENSOR FAULT (LRU = 17) ARE SET.
C26439
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões 169
CD Issue Date: 21 JAN/10
YES
C26410
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement 167
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
UPTRIM LAMP WRAPAROUND
(LSS4IF)
NO REPAIR / REPLACE
UPTRIM LAMP RELAY OK (REF. AMM)? (REF. AMM)
YES
NO REPLACE WIRING
CONTINUITY ON LINE 133 LESS THAN
HARNESS
OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE UPTRIM LAMP DRIVER SYSTEM IS FOUND TO BE INCORRECT.
C26409
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement 165
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
C26407
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DIRTY
NO
DISCONNECT P1 AND P8. TEST
REPLACE NO HARNESS LINES 114, 115, 116, 117
HARNESS AND 118 FOR CONTINUITY SHAKING
P8 CONNECTOR
YES
YES
C26408
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO A WITHIN +− 0.1% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R1)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C95981A
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
AIRCRAFT SYSTEM NO
RECTIFY
OK? (REF. AMM)
YES
SYSTEM NORMAL
C26413
Printed on: 10 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
INVESTIGATE
AIRCRAFT WIRING TO YES SYSTEM
PLA ENABLE
NORMAL
MICROSWITCHES
(REF. AMM). OK?
C26418
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SET CONDITION
LEVER AT FUEL CUTOFF
POSITION. TURN EEC
POWER OFF. REMOVE YES REPLACE
CONNECTOR P2 FROM EEC
EEC. ARE THERE 28 VDC
ON P2 − s OF ENGINE
HARNESS?
NO
CHECK CONTINUITY.
ENGINE HARNESS NO REPAIR / REPLACE
LINE 134 LESS ENGINE
THAN OR EQUAL TO HARNESS
0.5 OHM?
YES
YES
INVESTIGATE
AIRCRAFT WIRING.
ARE THERE 28 VDC NO
ON ENGINE HARNESS RECTIFY
DISCONNECT P11 − j
WHEN PROPELLER IS
FEATHERED?
YES
SYSTEM NORMAL
C26419
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
CONTINUED ON SHEET 2
C26414
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
C26341
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
YES
CONTINUED ON SHEET 4
C26415
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONTINUED ON SHEET 4
YES
REPLACE AIRCRAFT
TORQUE INDICATOR
(REF. AMM)
C26416
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NO
NO
C26417
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
AIRCRAFT SYSTEM NO
RECTIFY
OK? (REF. AMM)
YES
SYSTEM NORMAL
C26413
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26411
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
C26410
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
UPTRIM LAMP WRAPAROUND
(LSS4IF)
NO REPAIR / REPLACE
UPTRIM LAMP RELAY OK (REF. AMM)? (REF. AMM)
YES
NO REPLACE WIRING
CONTINUITY ON LINE 133 LESS THAN
HARNESS
OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE UPTRIM LAMP DRIVER SYSTEM IS FOUND TO BE INCORRECT.
C26409
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION YES
PLUG (REF. 72−01−10) SYSTEM NORMAL
OK?
NO
REPLACE EEC
(REF. 72−01−10)
OK?
YES
SYSTEM NORMAL
C37697
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26412
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
C26407
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DIRTY
NO
DISCONNECT P1 AND P8. TEST
REPLACE NO HARNESS LINES 114, 115, 116, 117
HARNESS AND 118 FOR CONTINUITY SHAKING
P8 CONNECTOR
YES
YES
C26408
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
C26406
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26405
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26404
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS. CONTINUITY ON LINES 119, 120, NO
HARNESS
121 AND 122 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26403
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26402
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR /REPLACE
APPLY GROUND TO PIN P11−B (−). IGNITION NO
AIRCRAFT WIRING /
COMES ON (ASSUMING GOOD IGNITERS)?
RELAY (REF. AMM)
YES
YES
NOTE: THIS FAULT IS SET IF EITHER THE AIRCRAFT / ENGINE SYSTEM IS NOT OPERATIONAL
OR THE EEC IS DAMAGED INTERNALLY.
C26401
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO REPAIR /REPLACE
APPLY 28 VDC TO PINS P11−AA (+) AND P11− b (−).
AIRCRAFT WIRING /
MANUAL LAMP OFF?
RELAY (REF. AMM)
YES
NO REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON LINES
ENGINE HARNESS
136 AND 137 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THE VOLTAGE SUPPLIED BY THE EEC TO THE FAIL FIXED RELAY AND THE MFCU STEPPER MOTOR
COMES FROM THE SAME DRIVER. THEREFORE, A SHORT CIRCUIT TO GROUND ON ANY ONE OF
THESE CIRCUITS WILL RESULT IN FAULT CODE LRU 85 BEING SET.
C26400
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 103, NO
HARNESS
104, 128 AND 129 LESS THAN 0.5 OHM?
(REF. 72−01−60)
YES
YES
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO PREVIOUS FAULT
CODES ARE SET FOR ANY OF THE NH PROBES AND THE DIFFERENCE BETWEEN THE TWO
READINGS EXCEEDS 0.9%.
C26399
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS CONTINUITY. RESISTANCE ON LINES NO
ENGINE HARNESS
128 AND 129 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH <30%), NPT IS
ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26398
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 1, PINS J14−3 NO
SENSOR NO. 1
TO J14−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH<30%), NPT
IS ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26397
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, PINS J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
C26396
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
TAKE APPROPRIATE
NH EXCEEDS 110% AND FAULT CODES YES ACTION FOR NH
LRU 12 AND 81 EXIST? OVERSPEED
(REF. 05−50−00)
NO
YES
YES
C26395
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS CONTINUITY. LINES 100, 101 NO
HARNESS
AND 102 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE INLET TEMPERATURE SENSOR LOCATED ON THE REAR INLET CASE
DOES NOT PASS A RANGE CHECK WHEN NH IS ABOVE 66% (I.E. THE ENGINE RUNNING).
C26394
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULT CODES FOR THE
COILS ARE SET AND THE DIFFERENCE BETWEEN THE TWO NPT COIL READINGS EXCEEDS 5%.
C26393
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR / REPLACE
CHECK HARNESS. IS CONTINUITY ON LINES NO
HARNESS
105, 106, 110 AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULTS ARE SET FOR
ANY COILS AND THE DIFFERENCE BETWEEN THE TWO TORQUE COIL READINGS EXCEEDS 5%.
C26392
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
YES
NOTE: WHEN THIS SIGNAL FAILS, THE EEC WILL DEFAULT TO A TORQUE SHAFT TEMPERATURE OF
80.5 ° C (176.6 ° F). THIS FAULT IS SET IF THE TORQUE SIGNAL FAILS TO PASS A RANGE CHECK.
C26391
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26390
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FOLLOW APPROPRIATE
YES
NP EXCEEDS 135% MAINTENANCE ACTION FOR
NP OVERSPEED (REF. 05−50−00)
NO
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26389
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO. 2.
C26388
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO.2.
C26387
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
REPLACE EEC
C26386
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO RECONNECT
IS CONNECTOR P1 SECURELY MATED TO J1?
P1 TO EEC
YES
NOTE: THIS FAULT IS SET IF LRU 74/78/84/90 ARE ALL SIMULTANEOUSLY LATCHED. THESE LRUs CORRESPOND
TO THE TORQUE SHAFT TEMPERATURE, NACELLE AMBIENT TEMPERATURE AND E1 AND E2 SIGNALS
FROM THE RVDT IN THE MFC.
C26385
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26384
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26383
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26382
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26381
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 1 PSIA IN MCL AND MCR RATINGS
AND +− 0.5 PSIA FOR OTHER RATINGS WITH PLA ABOVE 40 DEGREES.
C26380
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 28 ° F IN MCL AND MCR RATINGS
AND +− 14° F FOR OTHER RATINGS, TORQUE OUTPUT IS 90% OF TQBUG, AND PLA IS GREATER THAN
40 DEGREES.
C26379
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26378
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26377
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26376
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26374
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND
OUT OF FEATHER SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED
WHEN THE ENGINE IS NOT RUNNING. THIS FAULT IS SET IF THE ARINC INPUT LINK IS
FOUND TO BE INVALID WITH NPT ABOVE 60%.
C26375
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26373
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE WITH
NO
HAS A PW127F MFCU BEEN INSTALLED? CORRECT MFCU
(REF. 72−01−40)
YES
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 124 NO
ENGINE HARNESS
AND 125 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE EEC DOES NOT ACKNOWLEDGE CONTINUITY BETWEEN PINS J2− a
AND J2−D OF THE MFCU. THE PW127, PW127E AND PW127F MFCU’s PROVIDE HIGHER FLOWS
FOR OPERATION AT PW127, PW127E AND PW127F POWERS THAN THE PW124B MFCU.
THESE CONNECTED PINS WITHIN THE MFCU ARE A WAY FOR THE EEC
TO IDENTIFY A PW127, PW127E AND A PW127F MFCU.
C26432A
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO A WITHIN +− 0.1% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R1)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C95981A
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON
ENGINE HARNESS
LINES 112 AND 113 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
REPLACE EEC
(REF. 72−01−10)
C26371B
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26370
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: NO FAULT CODE IS SET IF THE INTERNAL ARINC DRIVER IS FOUND TO BE DEFECTIVE.
C26369
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26368
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO D WITHIN ± 1.0% OF VALUE
VALUES R3 AND R4
SHOWN ON PLUG DATA PLATE (R3)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26367A
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO E WITHIN +− 0.1% OF VALUE
VALUES R3 AND R4
SHOWN ON PLUG DATA PLATE (R4)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26366
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE DRIFT COMPENSATED FOR VARIATIONS IN TEMPERATURE.
THIS FAULT MAY ALSO OCCUR DUE TO AN ELECTRICAL POWER INTERRUPTION OR POWER
SUPPLY VOLTAGE REDUCTION.
C26365
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
ARE BOTH FULT CODES LRU 28 AND 29 YES CARRY OUT CHECK AS PER
ALSO SET? LRU FAULT CODE 28 AND 29
NO
REPLACE EEC
(REF. 72−01−10)
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE PROCESSED AND CONVERTED TO DIGITAL SIGNALS FOR USE
BY THE EEC. EACH SIGNAL IS GAIN COMPENSATED FOR VARIATIONS IN EXCITATION VOLTAGE.
THE GAIN SIGNAL IS CONTINUOUSLY RANGE CHECKED. VALUES OUTSIDE THIS RANGE ARE
CONSIDERED INVALID AND THIS FAULT IS FLAGGED.
C26364
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: AN INTERNAL EEC COLD JUNCTION IS USED TO CORRECT THE GAIN AND THE
DRIFT OF THE EEC PRESSURE TRANSDUCERS FOR THERMAL VARIATIONS.
C26363
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26362
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: LOW LEVEL INPUTS (mV) COMING FROM AMBIENT AND DIFFERENTIAL PRESSURE
TRANSDUCERS ARE GAIN CORRECTED WITHIN THE EEC. THIS GAIN CORRECTION
ACCOUNTS FOR STRAIN GAGE EXCITATION VARIATIONS.
C26361
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26360
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26359
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THE STATIC PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26358
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING AMBIENT PRESSURE TO THE EEC
ARE DETERMINED TO BE INVALID AND NPT IS ABOVE 60% (I.E. NOT ON THE GROUND).
C26357
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING TEMPERATURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60% (I.E. NOT ON THE GROUND).
C26356
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
NO
C26355
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
C26354A
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26352
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
REPLACE EEC
(REF. 72−01−10)
C26353
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FUNCTION PERFORMS A GENERAL CHECK ON THE EEC TORQUE CONVERSION PROCESS.
THE CHECK WILL DETECT AN INTERNAL EEC FAILURE OF THE TORQUE/NPT CONVERSION PROCESS.
C26351
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
08 LOSS OF INTERCOMPRESSOR
BLEED VALVE CONTROL
(HBOVIF)
THIS FAULT IS CAUSED BY A DUAL NH FAILURE AND THE MAINTENANCE PROCEDURE FOR LRU 12 IS
TO BE FOLLOWED.
THIS FAULT SENDS A "DASH−DASH" OUTPUT TO THE COCKPIT ON ARINC LABEL 340 TO TELL THE PILOT
THAT THE INTERCOMPRESSOR BLEED VALVE IS NOT OPERATIONAL.
C26350
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26349
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE : THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26348
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SET CONDITION
LEVER AT FUEL CUTOFF
POSITION. TURN EEC
POWER OFF. REMOVE YES REPLACE
CONNECTOR P2 FROM EEC
EEC. ARE THERE 28 VDC
ON P2 − s OF ENGINE
HARNESS?
NO
CHECK CONTINUITY.
ENGINE HARNESS NO REPAIR / REPLACE
LINE 134 LESS ENGINE
THAN OR EQUAL TO HARNESS
0.5 OHM?
YES
YES
INVESTIGATE
AIRCRAFT WIRING.
ARE THERE 28 VDC NO
ON ENGINE HARNESS RECTIFY
DISCONNECT P11 − j
WHEN PROPELLER IS
FEATHERED?
YES
SYSTEM NORMAL
C26419
Printed on: 11 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THE STATIC PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26425
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING AMBIENT PRESSURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60& (I.E. NOT ON THE GROUND).
C26424
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING TEMPERATURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60% (I.E. NOT ON THE GROUND).
C26423
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
NO
C26355
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26422
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
REPLACE EEC
(REF. 72−01−10)
C26353
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FUNCTION PERFORMS A GENERAL CHECK ON THE EEC TORQUE CONVERSION PROCESS.
THE CHECK WILL DETECT AN INTERNAL EEC FAILURE OF THE TORQUE / NPT CONVERSION PROCESS.
C26421
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26349
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE : THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26348
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. DURING INITIALIZATION, THE EEC LOCATED PRESSURE TRANSDUCER CALIBRATION DATA IS
VERIFIED. IF INVALID, THIS FAULT IS FLAGGED AND THE EEC ASSUMES DEFAULT VALVES.
C26426
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DRIFT CORRECTION TO LOW LEVEL (mV) INPUTS IS TO ACCOUNT FOR HARDWARE
AMPLIFIER DRIFT.
C26429
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION YES
PLUG (REF. 72−01−10) SYSTEM NORMAL
OK?
NO
REPLACE EEC
(REF. 72−01−10)
OK?
YES
SYSTEM NORMAL
C37697
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
AIRCRAFT SYSTEM NO
RECTIFY
OK? (REF. AMM)
YES
SYSTEM NORMAL
C26413
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
REFER TO CAUTION
REPLACE THE EEC WITH ANOTHER. YES
IS THE FAULT CLEARED ?
(REF. 72−01−10)
NO
C129043A
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
DISCONNECT THE P2, P17 AND J11 CONNECTORS FROM THE ENGINE
HARNESS. DO A CONTINUITY CHECK FROM THE P17 CONNECTOR PINS
TO THE P2 CONNECTOR PINS AND FROM THE P17 CONNECTOR PINS TO
THE J11 CONNECTOR PINS AS SHOWN BELOW. THE RESULTS SHOULD
BE AS FOLLOWS:
CONTINUITY NO CONTINUITY
NO
P17 [1] TO J11 [Z] P17 [1] & ALL OTHER PINS IN CONNECTOR CASE
P17 [2] TO J11 [ a ] P17 [2] & ALL OTHER PINS IN CONNECTOR CASE
P17 [3] TO P2 [GG] P17 [3] & ALL OTHER PINS IN CONNECTOR CASE
P17 [4] TO P2 [ z ] P17 [4] & ALL OTHER PINS IN CONNECTOR CASE
P17 [5] TO P2 [ k ] P17 [5] & ALL OTHER PINS IN CONNECTOR CASE
P17 [6] TO P2 [ m ] P17 [6] & ALL OTHER PINS IN CONNECTOR CASE
YES
RETURN TO SERVICE
NOTE:
WHEN A NEW DCU IS INSTALLED ON THE ENGINE, YOU MAY
HAVE TO UPDATE THE ACCUMULATED CYCLES IN THE DCU
TO ACCOUNT FOR CYCLES THAT MAY NOT HAVE BEEN
COUNTED BY THE DCU WHILE THE FAULT CODE WAS PRESENT.
C129044
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26405
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26404
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS. CONTINUITY ON LINES 119, 120, NO
HARNESS
121 AND 122 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26403
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26402
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR /REPLACE
APPLY GROUND TO PIN P11−B (−). IGNITION NO
AIRCRAFT WIRING /
COMES ON (ASSUMING GOOD IGNITERS)?
RELAY (REF. AMM)
YES
YES
NOTE: THIS FAULT IS SET IF EITHER THE AIRCRAFT / ENGINE SYSTEM IS NOT OPERATIONAL
OR THE EEC IS DAMAGED INTERNALLY.
C26401
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO REPAIR /REPLACE
APPLY 28 VDC TO PINS P11−AA (+) AND P11− b (−).
AIRCRAFT WIRING /
MANUAL LAMP OFF?
RELAY (REF. AMM)
YES
NO REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON LINES
ENGINE HARNESS
136 AND 137 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THE VOLTAGE SUPPLIED BY THE EEC TO THE FAIL FIXED RELAY AND THE MFCU STEPPER MOTOR
COMES FROM THE SAME DRIVER. THEREFORE, A SHORT CIRCUIT TO GROUND ON ANY ONE OF
THESE CIRCUITS WILL RESULT IN FAULT CODE LRU 85 BEING SET.
C26400
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 103, NO
HARNESS
104, 128 AND 129 LESS THAN 0.5 OHM?
(REF. 72−01−60)
YES
YES
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO PREVIOUS FAULT
CODES ARE SET FOR ANY OF THE NH PROBES AND THE DIFFERENCE BETWEEN THE TWO
READINGS EXCEEDS 0.9%.
C26399
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS CONTINUITY. RESISTANCE ON LINES NO
ENGINE HARNESS
128 AND 129 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH <30%), NPT IS
ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26398
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 1, PINS J14−3 NO
SENSOR NO. 1
TO J14−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH<30%), NPT
IS ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26397
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, PINS J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
C26396
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
TAKE APPROPRIATE
NH EXCEEDS 110% AND FAULT CODES YES ACTION FOR NH
LRU 12 AND 81 EXIST? OVERSPEED
(REF. 05−50−00)
NO
YES
YES
C26395
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS CONTINUITY. LINES 100, 101 NO
HARNESS
AND 102 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE INLET TEMPERATURE SENSOR LOCATED ON THE REAR INLET CASE
DOES NOT PASS A RANGE CHECK WHEN NH IS ABOVE 66% (I.E. THE ENGINE RUNNING).
C26394
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: WHEN THIS SIGNAL FAILS, THE EEC WILL DEFAULT TO A TORQUE SHAFT TEMPERATURE OF
80.5 ° C (176.6 ° F). THIS FAULT IS SET IF THE TORQUE TEMPERATURE SIGNAL FAILS TO PASS
A RANGE CHECK.
C26438
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26390
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FOLLOW APPROPRIATE
YES
NP EXCEEDS 135% MAINTENANCE ACTION FOR
NP OVERSPEED (REF. 05−50−00)
NO
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26389
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO. 2.
C26388
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO.2.
C26387
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26437
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO RECONNECT
IS CONNECTOR P1 SECURELY MATED TO J1?
P1 TO EEC
YES
NOTE: THIS FAULT IS SET IF LRU 74/78/84/90 ARE ALL SIMULTANEOUSLY LATCHED. THESE LRU’s
CORRESPOND TO THE TORQUE SHAFT TEMPERATURE, NACELLE AMBIENT TEMPERATURE
AND E1 AND E2 SIGNALS FROM THE RVDT IN THE MFC.
C26436
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 1 PSIA IN MCL AND MCR RATINGS
AND +− 0.5 PSIA FOR OTHER RATINGS WITH PLA ABOVE 40 DEGREES.
C26380
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 28 ° F IN MCL AND MCR RATINGS
AND +− 14° F FOR OTHER RATINGS, TORQUE OUTPUT IS 90% OF TQBUG, AND PLA IS GREATER THAN
40 DEGREES.
C26379
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26378
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26377
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26376
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26374
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND
OUT OF FEATHER SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED
WHEN THE ENGINE IS NOT RUNNING. THIS FAULT IS SET IF THE ARINC INPUT LINK IS
FOUND TO BE INVALID WITH NPT ABOVE 60%.
C26375
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO A WITHIN +− 0.1% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R1)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C95981A
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26370
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: NO FAULT CODE IS SET IF THE INTERNAL ARINC DRIVER IS FOUND TO BE DEFECTIVE.
C26369
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26368
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO D WITHIN €±1.0% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R3)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26367B
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHECK CONTINUITY RESISTANCE BETWEEN CHARACTERIZATION
NO PLUG WITH RESISTOR
PINS. C TO E WITHIN ± 1.0% OF VALUE
SHOWN ON PLUG DATA PLATE (R4)? VALUES R1, R3 AND R4
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26366B
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE DRIFT COMPENSATED FOR VARIATIONS IN TEMPERATURE.
THIS FAULT MAY ALSO OCCUR DUE TO AN ELECTRICAL POWER INTERRUPTION OR POWER
SUPPLY VOLTAGE REDUCTION.
C26365
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
ARE BOTH FULT CODES LRU 28 AND 29 YES CARRY OUT CHECK AS PER
ALSO SET? LRU FAULT CODE 28 AND 29
NO
REPLACE EEC
(REF. 72−01−10)
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE PROCESSED AND CONVERTED TO DIGITAL SIGNALS FOR USE
BY THE EEC. EACH SIGNAL IS GAIN COMPENSATED FOR VARIATIONS IN EXCITATION VOLTAGE.
THE GAIN SIGNAL IS CONTINUOUSLY RANGE CHECKED. VALUES OUTSIDE THIS RANGE ARE
CONSIDERED INVALID AND THIS FAULT IS FLAGGED.
C26364
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. AN INTERNAL EEC COLD JUNCTION IS USED TO CORRECT THE GAIN AND THE DRIFT
OF THE EEC PRESSURE TRANSDUCERS FOR THERMAL VARIATIONS.
2. THIS FAULT WILL ALSO SET LRU = 44.
C26430
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. LOW LEVEL INPUTS (mV) COMING FROM AMBIENT AND DIFFERENTIAL PRESSURE TRANSDUCERS
ARE GAIN CORRECTED WITHIN THE EEC. THIS GAIN CORRECTION ACCOUNTS FOR STRAIN GAGE
EXCITATION VARIATIONS.
C26428
Printed on: 13 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SET CONDITION
LEVER AT FUEL CUTOFF
POSITION. TURN EEC
POWER OFF. REMOVE YES REPLACE
CONNECTOR P2 FROM EEC
EEC. ARE THERE 28 VDC
ON P2 − s OF ENGINE
HARNESS?
NO
CHECK CONTINUITY.
ENGINE HARNESS NO REPAIR / REPLACE
LINE 134 LESS ENGINE
THAN OR EQUAL TO HARNESS
0.5 OHM?
YES
YES
INVESTIGATE
AIRCRAFT WIRING.
ARE THERE 28 VDC NO
ON ENGINE HARNESS RECTIFY
DISCONNECT P11 − j
WHEN PROPELLER IS
FEATHERED?
YES
SYSTEM NORMAL
C26419A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
INVESTIGATE
AIRCRAFT WIRING TO YES SYSTEM
PLA ENABLE
NORMAL
MICROSWITCHES
(REF. AMM). OK?
C26418
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
CONTINUED ON SHEET 2
C26414
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
C26341
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
YES
CONTINUED ON SHEET 4
C26415
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONTINUED ON SHEET 4
YES
REPLACE AIRCRAFT
TORQUE INDICATOR
(REF. AMM)
C26416
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NO
NO
C26417
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
AIRCRAFT SYSTEM NO
RECTIFY
OK? (REF. AMM)
YES
SYSTEM NORMAL
C26413
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26412
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26411
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
DUAL AIRSPEED INPUT FAULT
(IASIF)
SYMPTOMS SUSPECT LRU
POSSIBLE TORQUE SPLIT 1. EEC AND
POSSIBLE DEGRADE ENGINE AND PROPELLER 2. ADC
PERFORMANCE 3. WIRING
LRU 19
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT IS SET WHEN BOTH ARINC AIRSPEED INPUT FAULT (LRU = 54) AND DELTA
P SENSOR FAULT (LRU = 17) ARE SET.
C26439
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
C26410
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION YES
PLUG (REF. 72−01−10) SYSTEM NORMAL
OK?
NO
REPLACE EEC
(REF. 72−01−10)
OK?
YES
SYSTEM NORMAL
C37697
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
UPTRIM LAMP WRAPAROUND
(LSS4IF)
NO REPAIR / REPLACE
UPTRIM LAMP RELAY OK (REF. AMM)? (REF. AMM)
YES
NO REPLACE WIRING
CONTINUITY ON LINE 133 LESS THAN
HARNESS
OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE UPTRIM LAMP DRIVER SYSTEM IS FOUND TO BE INCORRECT.
C26409
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
C26407
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DIRTY
NO
DISCONNECT P1 AND P8. TEST
REPLACE NO HARNESS LINES 114, 115, 116, 117
HARNESS AND 118 FOR CONTINUITY SHAKING
P8 CONNECTOR
YES
YES
C26408
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
C26406
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26405
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26404
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS. CONTINUITY ON LINES 119, 120, NO
HARNESS
121 AND 122 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26403
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26402
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR /REPLACE
APPLY GROUND TO PIN P11−B (−). IGNITION NO
AIRCRAFT WIRING /
COMES ON (ASSUMING GOOD IGNITERS)?
RELAY (REF. AMM)
YES
YES
NOTE: THIS FAULT IS SET IF EITHER THE AIRCRAFT / ENGINE SYSTEM IS NOT OPERATIONAL
OR THE EEC IS DAMAGED INTERNALLY.
C26401
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO REPAIR /REPLACE
APPLY 28 VDC TO PINS P11−AA (+) AND P11− b (−).
AIRCRAFT WIRING /
MANUAL LAMP OFF?
RELAY (REF. AMM)
YES
NO REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON LINES
ENGINE HARNESS
136 AND 137 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THE VOLTAGE SUPPLIED BY THE EEC TO THE FAIL FIXED RELAY AND THE MFCU STEPPER MOTOR
COMES FROM THE SAME DRIVER. THEREFORE, A SHORT CIRCUIT TO GROUND ON ANY ONE OF
THESE CIRCUITS WILL RESULT IN FAULT CODE LRU 85 BEING SET.
C26400
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 103, NO
HARNESS
104, 128 AND 129 LESS THAN 0.5 OHM?
(REF. 72−01−60)
YES
YES
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO PREVIOUS FAULT
CODES ARE SET FOR ANY OF THE NH PROBES AND THE DIFFERENCE BETWEEN THE TWO
READINGS EXCEEDS 0.9%.
C26399
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS CONTINUITY. RESISTANCE ON LINES NO
ENGINE HARNESS
128 AND 129 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH <30%), NPT IS
ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26398
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 1, PINS J14−3 NO
SENSOR NO. 1
TO J14−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH<30%), NPT
IS ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26397
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, PINS J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
C26396
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
TAKE APPROPRIATE
NH EXCEEDS 110% AND FAULT CODES YES ACTION FOR NH
LRU 12 AND 81 EXIST? OVERSPEED
(REF. 05−50−00)
NO
YES
YES
C26395
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS CONTINUITY. LINES 100, 101 NO
HARNESS
AND 102 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE INLET TEMPERATURE SENSOR LOCATED ON THE REAR INLET CASE
DOES NOT PASS A RANGE CHECK WHEN NH IS ABOVE 66% (I.E. THE ENGINE RUNNING).
C26394
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULT CODES FOR THE
COILS ARE SET AND THE DIFFERENCE BETWEEN THE TWO NPT COIL READINGS EXCEEDS 5%.
C26393
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR / REPLACE
CHECK HARNESS. IS CONTINUITY ON LINES NO
HARNESS
105, 106, 110 AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULTS ARE SET FOR
ANY COILS AND THE DIFFERENCE BETWEEN THE TWO TORQUE COIL READINGS EXCEEDS 5%.
C26392
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: WHEN THIS SIGNAL FAILS, THE EEC WILL DEFAULT TO A TORQUE SHAFT TEMPERATURE OF
80.5 ° C (176.6 ° F). THIS FAULT IS SET IF THE TORQUE TEMPERATURE SIGNAL FAILS TO PASS
A RANGE CHECK.
C26438
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26390
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FOLLOW APPROPRIATE
YES
NP EXCEEDS 135% MAINTENANCE ACTION FOR
NP OVERSPEED (REF. 05−50−00)
NO
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26389
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO. 2.
C26388
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO.2.
C26387
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26437
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO RECONNECT
IS CONNECTOR P1 SECURELY MATED TO J1?
P1 TO EEC
YES
NOTE: THIS FAULT IS SET IF LRU 74/78/84/90 ARE ALL SIMULTANEOUSLY LATCHED. THESE LRU’s
CORRESPOND TO THE TORQUE SHAFT TEMPERATURE, NACELLE AMBIENT TEMPERATURE
AND E1 AND E2 SIGNALS FROM THE RVDT IN THE MFC.
C26436
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26384
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26383
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26382
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26381
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 1 PSIA IN MCL AND MCR RATINGS
AND +− 0.5 PSIA FOR OTHER RATINGS WITH PLA ABOVE 40 DEGREES.
C26380
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 28 ° F IN MCL AND MCR RATINGS
AND +− 14° F FOR OTHER RATINGS, TORQUE OUTPUT IS 90% OF TQBUG, AND PLA IS GREATER THAN
40 DEGREES.
C26379
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26435
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT IS SET IF THE FOLLOWING TORQUE LEVELS ARE MAINTAINED FOR THE CONTINUOUS
PERIODS INDICATED:
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26434
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT OCCURS WHEN THE ENGINE TORQUE IS BETWEEN 122% AND 137% (12800 −14440
LB. FT. ) FOR A CONTINUOUS PERIOD OF TIME GREATER THAN 20 AND LESS THAN 3000 SECONDS,
OR WHEN THE ENGINE TORQUE IS BETWEEN 100% AND 122% (10504−12800 LB. FT.) FOR A
CONTINUOUS PERIOD OF TIME GREATER THAN 600 SECONDS.
C26433
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26378
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26377
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26376
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26374
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND
OUT OF FEATHER SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED
WHEN THE ENGINE IS NOT RUNNING. THIS FAULT IS SET IF THE ARINC INPUT LINK IS
FOUND TO BE INVALID WITH NPT ABOVE 60%.
C26375
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26373
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE WITH
NO
HAS A PW127F MFCU BEEN INSTALLED? CORRECT MFCU
(REF. 72−01−40)
YES
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 124 NO
ENGINE HARNESS
AND 125 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE EEC DOES NOT ACKNOWLEDGE CONTINUITY BETWEEN PINS J2− a
AND J2−D OF THE MFCU. THE PW127, PW127E AND PW127F MFCU’s PROVIDE HIGHER FLOWS
FOR OPERATION AT PW127, PW127E AND PW127F POWERS THAN THE PW124B MFCU.
THESE CONNECTED PINS WITHIN THE MFCU ARE A WAY FOR THE EEC
TO IDENTIFY A PW127, PW127E AND A PW127F MFCU.
C26432A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO A WITHIN +− 0.1% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R1)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C95981A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THE INDICATION TO THE EEC COMES FROM A RANGE CHECK PERFORMED ON
THE OUTPUT WRAPAROUND CIRCUITRY.
REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON NO
ENGINE HARNESS
LINES 112 AND 113 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE EEC
(REF. 72−01−10)
C26431B
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26370
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: NO FAULT CODE IS SET IF THE INTERNAL ARINC DRIVER IS FOUND TO BE DEFECTIVE.
C26369
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26368
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO D WITHIN €±1.0% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R3)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26367B
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHECK CONTINUITY RESISTANCE BETWEEN CHARACTERIZATION
NO PLUG WITH RESISTOR
PINS. C TO E WITHIN ± 1.0% OF VALUE
SHOWN ON PLUG DATA PLATE (R4)? VALUES R1, R3 AND R4
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26366B
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE DRIFT COMPENSATED FOR VARIATIONS IN TEMPERATURE.
THIS FAULT MAY ALSO OCCUR DUE TO AN ELECTRICAL POWER INTERRUPTION OR POWER
SUPPLY VOLTAGE REDUCTION.
C26365
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
ARE BOTH FULT CODES LRU 28 AND 29 YES CARRY OUT CHECK AS PER
ALSO SET? LRU FAULT CODE 28 AND 29
NO
REPLACE EEC
(REF. 72−01−10)
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE PROCESSED AND CONVERTED TO DIGITAL SIGNALS FOR USE
BY THE EEC. EACH SIGNAL IS GAIN COMPENSATED FOR VARIATIONS IN EXCITATION VOLTAGE.
THE GAIN SIGNAL IS CONTINUOUSLY RANGE CHECKED. VALUES OUTSIDE THIS RANGE ARE
CONSIDERED INVALID AND THIS FAULT IS FLAGGED.
C26364
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. AN INTERNAL EEC COLD JUNCTION IS USED TO CORRECT THE GAIN AND THE DRIFT
OF THE EEC PRESSURE TRANSDUCERS FOR THERMAL VARIATIONS.
2. THIS FAULT WILL ALSO SET LRU = 44.
C26430
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DRIFT CORRECTION TO LOW LEVEL (mV) INPUTS IS TO ACCOUNT FOR HARDWARE
AMPLIFIER DRIFT.
C26429
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. LOW LEVEL INPUTS (mV) COMING FROM AMBIENT AND DIFFERENTIAL PRESSURE TRANSDUCERS
ARE GAIN CORRECTED WITHIN THE EEC. THIS GAIN CORRECTION ACCOUNTS FOR STRAIN GAGE
EXCITATION VARIATIONS.
C26428
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DELTA−P PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26427
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. DURING INITIALIZATION, THE EEC LOCATED PRESSURE TRANSDUCER CALIBRATION DATA IS
VERIFIED. IF INVALID, THIS FAULT IS FLAGGED AND THE EEC ASSUMES DEFAULT VALVES.
C26426
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THE STATIC PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26425
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING AMBIENT PRESSURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60& (I.E. NOT ON THE GROUND).
C26424
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING TEMPERATURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60% (I.E. NOT ON THE GROUND).
C26423
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
NO
C26355
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
C26354A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26422
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
REPLACE EEC
(REF. 72−01−10)
C26353
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FUNCTION PERFORMS A GENERAL CHECK ON THE EEC TORQUE CONVERSION PROCESS.
THE CHECK WILL DETECT AN INTERNAL EEC FAILURE OF THE TORQUE / NPT CONVERSION PROCESS.
C26421
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
THIS FAULT IS CAUSED BY A DUAL NH FAILURE AND THE MAINTENANCE PROCEDURE FOR
LRU 12 IS TO BE FOLLOWED.
THIS FAULT SENDS A "DASH−DASH" OUTPUT TO THE COCKPIT ON ARINC LABEL 343 TO TELL
THE PILOT THAT THE INTERCOMPRESSOR BLEED VALVE IS NOT OPERATIONAL.
C26420
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26349
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE : THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26348
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
REFER TO CAUTION
REPLACE THE EEC WITH ANOTHER. YES
IS THE FAULT CLEARED ?
(REF. 72−01−10)
NO
C129043A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
DISCONNECT THE P2, P17 AND J11 CONNECTORS FROM THE ENGINE
HARNESS. DO A CONTINUITY CHECK FROM THE P17 CONNECTOR PINS
TO THE P2 CONNECTOR PINS AND FROM THE P17 CONNECTOR PINS TO
THE J11 CONNECTOR PINS AS SHOWN BELOW. THE RESULTS SHOULD
BE AS FOLLOWS:
CONTINUITY NO CONTINUITY
NO
P17 [1] TO J11 [Z] P17 [1] & ALL OTHER PINS IN CONNECTOR CASE
P17 [2] TO J11 [ a ] P17 [2] & ALL OTHER PINS IN CONNECTOR CASE
P17 [3] TO P2 [GG] P17 [3] & ALL OTHER PINS IN CONNECTOR CASE
P17 [4] TO P2 [ z ] P17 [4] & ALL OTHER PINS IN CONNECTOR CASE
P17 [5] TO P2 [ k ] P17 [5] & ALL OTHER PINS IN CONNECTOR CASE
P17 [6] TO P2 [ m ] P17 [6] & ALL OTHER PINS IN CONNECTOR CASE
YES
RETURN TO SERVICE
NOTE:
WHEN A NEW DCU IS INSTALLED ON THE ENGINE, YOU MAY
HAVE TO UPDATE THE ACCUMULATED CYCLES IN THE DCU
TO ACCOUNT FOR CYCLES THAT MAY NOT HAVE BEEN
COUNTED BY THE DCU WHILE THE FAULT CODE WAS PRESENT.
C129044
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SET CONDITION
LEVER AT FUEL CUTOFF
POSITION. TURN EEC
POWER OFF. REMOVE YES REPLACE
CONNECTOR P2 FROM EEC
EEC. ARE THERE 28 VDC
ON P2 − s OF ENGINE
HARNESS?
NO
CHECK CONTINUITY.
ENGINE HARNESS NO REPAIR / REPLACE
LINE 134 LESS ENGINE
THAN OR EQUAL TO HARNESS
0.5 OHM?
YES
YES
INVESTIGATE
AIRCRAFT WIRING.
ARE THERE 28 VDC NO
ON ENGINE HARNESS RECTIFY
DISCONNECT P11 − j
WHEN PROPELLER IS
FEATHERED?
YES
SYSTEM NORMAL
C26419A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
INVESTIGATE
AIRCRAFT WIRING TO YES SYSTEM
PLA ENABLE
NORMAL
MICROSWITCHES
(REF. AMM). OK?
C26418
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
CONTINUED ON SHEET 2
C26414
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
C26341
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
YES
CONTINUED ON SHEET 4
C26415
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONTINUED ON SHEET 4
YES
REPLACE AIRCRAFT
TORQUE INDICATOR
(REF. AMM)
C26416
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NO
NO
C26417
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
AIRCRAFT SYSTEM NO
RECTIFY
OK? (REF. AMM)
YES
SYSTEM NORMAL
C26413
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26412
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26411
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
DUAL AIRSPEED INPUT FAULT
(IASIF)
SYMPTOMS SUSPECT LRU
POSSIBLE TORQUE SPLIT 1. EEC AND
POSSIBLE DEGRADE ENGINE AND PROPELLER 2. ADC
PERFORMANCE 3. WIRING
LRU 19
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT IS SET WHEN BOTH ARINC AIRSPEED INPUT FAULT (LRU = 54) AND DELTA
P SENSOR FAULT (LRU = 17) ARE SET.
C26439
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
C26410
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION YES
PLUG (REF. 72−01−10) SYSTEM NORMAL
OK?
NO
REPLACE EEC
(REF. 72−01−10)
OK?
YES
SYSTEM NORMAL
C37697
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
UPTRIM LAMP WRAPAROUND
(LSS4IF)
NO REPAIR / REPLACE
UPTRIM LAMP RELAY OK (REF. AMM)? (REF. AMM)
YES
NO REPLACE WIRING
CONTINUITY ON LINE 133 LESS THAN
HARNESS
OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE UPTRIM LAMP DRIVER SYSTEM IS FOUND TO BE INCORRECT.
C26409
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
C26407
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DIRTY
NO
DISCONNECT P1 AND P8. TEST
REPLACE NO HARNESS LINES 114, 115, 116, 117
HARNESS AND 118 FOR CONTINUITY SHAKING
P8 CONNECTOR
YES
YES
C26408
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
C26406
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26405
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26404
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS. CONTINUITY ON LINES 119, 120, NO
HARNESS
121 AND 122 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26403
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26402
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR /REPLACE
APPLY GROUND TO PIN P11−B (−). IGNITION NO
AIRCRAFT WIRING /
COMES ON (ASSUMING GOOD IGNITERS)?
RELAY (REF. AMM)
YES
YES
NOTE: THIS FAULT IS SET IF EITHER THE AIRCRAFT / ENGINE SYSTEM IS NOT OPERATIONAL
OR THE EEC IS DAMAGED INTERNALLY.
C26401
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO REPAIR /REPLACE
APPLY 28 VDC TO PINS P11−AA (+) AND P11− b (−).
AIRCRAFT WIRING /
MANUAL LAMP OFF?
RELAY (REF. AMM)
YES
NO REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON LINES
ENGINE HARNESS
136 AND 137 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THE VOLTAGE SUPPLIED BY THE EEC TO THE FAIL FIXED RELAY AND THE MFCU STEPPER MOTOR
COMES FROM THE SAME DRIVER. THEREFORE, A SHORT CIRCUIT TO GROUND ON ANY ONE OF
THESE CIRCUITS WILL RESULT IN FAULT CODE LRU 85 BEING SET.
C26400
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 103, NO
HARNESS
104, 128 AND 129 LESS THAN 0.5 OHM?
(REF. 72−01−60)
YES
YES
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO PREVIOUS FAULT
CODES ARE SET FOR ANY OF THE NH PROBES AND THE DIFFERENCE BETWEEN THE TWO
READINGS EXCEEDS 0.9%.
C26399
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS CONTINUITY. RESISTANCE ON LINES NO
ENGINE HARNESS
128 AND 129 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH <30%), NPT IS
ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26398
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 1, PINS J14−3 NO
SENSOR NO. 1
TO J14−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH<30%), NPT
IS ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26397
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, PINS J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
C26396
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
TAKE APPROPRIATE
NH EXCEEDS 110% AND FAULT CODES YES ACTION FOR NH
LRU 12 AND 81 EXIST? OVERSPEED
(REF. 05−50−00)
NO
YES
YES
C26395
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS CONTINUITY. LINES 100, 101 NO
HARNESS
AND 102 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE INLET TEMPERATURE SENSOR LOCATED ON THE REAR INLET CASE
DOES NOT PASS A RANGE CHECK WHEN NH IS ABOVE 66% (I.E. THE ENGINE RUNNING).
C26394
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULT CODES FOR THE
COILS ARE SET AND THE DIFFERENCE BETWEEN THE TWO NPT COIL READINGS EXCEEDS 5%.
C26393
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR / REPLACE
CHECK HARNESS. IS CONTINUITY ON LINES NO
HARNESS
105, 106, 110 AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULTS ARE SET FOR
ANY COILS AND THE DIFFERENCE BETWEEN THE TWO TORQUE COIL READINGS EXCEEDS 5%.
C26392
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: WHEN THIS SIGNAL FAILS, THE EEC WILL DEFAULT TO A TORQUE SHAFT TEMPERATURE OF
80.5 ° C (176.6 ° F). THIS FAULT IS SET IF THE TORQUE TEMPERATURE SIGNAL FAILS TO PASS
A RANGE CHECK.
C26438
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26390
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FOLLOW APPROPRIATE
YES
NP EXCEEDS 135% MAINTENANCE ACTION FOR
NP OVERSPEED (REF. 05−50−00)
NO
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26389
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO. 2.
C26388
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO.2.
C26387
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26437
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO RECONNECT
IS CONNECTOR P1 SECURELY MATED TO J1?
P1 TO EEC
YES
NOTE: THIS FAULT IS SET IF LRU 74/78/84/90 ARE ALL SIMULTANEOUSLY LATCHED. THESE LRU’s
CORRESPOND TO THE TORQUE SHAFT TEMPERATURE, NACELLE AMBIENT TEMPERATURE
AND E1 AND E2 SIGNALS FROM THE RVDT IN THE MFC.
C26436
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26384
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26383
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26382
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26381
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 1 PSIA IN MCL AND MCR RATINGS
AND +− 0.5 PSIA FOR OTHER RATINGS WITH PLA ABOVE 40 DEGREES.
C26380
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 28 ° F IN MCL AND MCR RATINGS
AND +− 14° F FOR OTHER RATINGS, TORQUE OUTPUT IS 90% OF TQBUG, AND PLA IS GREATER THAN
40 DEGREES.
C26379
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26435
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT IS SET IF THE FOLLOWING TORQUE LEVELS ARE MAINTAINED FOR THE CONTINUOUS
PERIODS INDICATED:
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26434
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT OCCURS WHEN THE ENGINE TORQUE IS BETWEEN 122% AND 137% (12800 −14440
LB. FT. ) FOR A CONTINUOUS PERIOD OF TIME GREATER THAN 20 AND LESS THAN 3000 SECONDS,
OR WHEN THE ENGINE TORQUE IS BETWEEN 100% AND 122% (10504−12800 LB. FT.) FOR A
CONTINUOUS PERIOD OF TIME GREATER THAN 600 SECONDS.
C26433
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26378
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26377
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26376
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26374
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND
OUT OF FEATHER SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED
WHEN THE ENGINE IS NOT RUNNING. THIS FAULT IS SET IF THE ARINC INPUT LINK IS
FOUND TO BE INVALID WITH NPT ABOVE 60%.
C26375
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26373
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE WITH
NO
HAS A PW127F MFCU BEEN INSTALLED? CORRECT MFCU
(REF. 72−01−40)
YES
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 124 NO
ENGINE HARNESS
AND 125 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE EEC DOES NOT ACKNOWLEDGE CONTINUITY BETWEEN PINS J2− a
AND J2−D OF THE MFCU. THE PW127, PW127E AND PW127F MFCU’s PROVIDE HIGHER FLOWS
FOR OPERATION AT PW127, PW127E AND PW127F POWERS THAN THE PW124B MFCU.
THESE CONNECTED PINS WITHIN THE MFCU ARE A WAY FOR THE EEC
TO IDENTIFY A PW127, PW127E AND A PW127F MFCU.
C26432A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO A WITHIN +− 0.1% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R1)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C95981A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THE INDICATION TO THE EEC COMES FROM A RANGE CHECK PERFORMED ON
THE OUTPUT WRAPAROUND CIRCUITRY.
REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON NO
ENGINE HARNESS
LINES 112 AND 113 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE EEC
(REF. 72−01−10)
C26431B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26370
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: NO FAULT CODE IS SET IF THE INTERNAL ARINC DRIVER IS FOUND TO BE DEFECTIVE.
C26369
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26368
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO D WITHIN €±1.0% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R3)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26367B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHECK CONTINUITY RESISTANCE BETWEEN CHARACTERIZATION
NO PLUG WITH RESISTOR
PINS. C TO E WITHIN ± 1.0% OF VALUE
SHOWN ON PLUG DATA PLATE (R4)? VALUES R1, R3 AND R4
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26366B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE DRIFT COMPENSATED FOR VARIATIONS IN TEMPERATURE.
THIS FAULT MAY ALSO OCCUR DUE TO AN ELECTRICAL POWER INTERRUPTION OR POWER
SUPPLY VOLTAGE REDUCTION.
C26365
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
ARE BOTH FULT CODES LRU 28 AND 29 YES CARRY OUT CHECK AS PER
ALSO SET? LRU FAULT CODE 28 AND 29
NO
REPLACE EEC
(REF. 72−01−10)
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE PROCESSED AND CONVERTED TO DIGITAL SIGNALS FOR USE
BY THE EEC. EACH SIGNAL IS GAIN COMPENSATED FOR VARIATIONS IN EXCITATION VOLTAGE.
THE GAIN SIGNAL IS CONTINUOUSLY RANGE CHECKED. VALUES OUTSIDE THIS RANGE ARE
CONSIDERED INVALID AND THIS FAULT IS FLAGGED.
C26364
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. AN INTERNAL EEC COLD JUNCTION IS USED TO CORRECT THE GAIN AND THE DRIFT
OF THE EEC PRESSURE TRANSDUCERS FOR THERMAL VARIATIONS.
2. THIS FAULT WILL ALSO SET LRU = 44.
C26430
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DRIFT CORRECTION TO LOW LEVEL (mV) INPUTS IS TO ACCOUNT FOR HARDWARE
AMPLIFIER DRIFT.
C26429
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. LOW LEVEL INPUTS (mV) COMING FROM AMBIENT AND DIFFERENTIAL PRESSURE TRANSDUCERS
ARE GAIN CORRECTED WITHIN THE EEC. THIS GAIN CORRECTION ACCOUNTS FOR STRAIN GAGE
EXCITATION VARIATIONS.
C26428
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DELTA−P PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26427
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. DURING INITIALIZATION, THE EEC LOCATED PRESSURE TRANSDUCER CALIBRATION DATA IS
VERIFIED. IF INVALID, THIS FAULT IS FLAGGED AND THE EEC ASSUMES DEFAULT VALVES.
C26426
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THE STATIC PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26425
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING AMBIENT PRESSURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60& (I.E. NOT ON THE GROUND).
C26424
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING TEMPERATURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60% (I.E. NOT ON THE GROUND).
C26423
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
NO
C26355
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
C26354A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26422
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
REPLACE EEC
(REF. 72−01−10)
C26353
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FUNCTION PERFORMS A GENERAL CHECK ON THE EEC TORQUE CONVERSION PROCESS.
THE CHECK WILL DETECT AN INTERNAL EEC FAILURE OF THE TORQUE / NPT CONVERSION PROCESS.
C26421
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
THIS FAULT IS CAUSED BY A DUAL NH FAILURE AND THE MAINTENANCE PROCEDURE FOR
LRU 12 IS TO BE FOLLOWED.
THIS FAULT SENDS A "DASH−DASH" OUTPUT TO THE COCKPIT ON ARINC LABEL 343 TO TELL
THE PILOT THAT THE INTERCOMPRESSOR BLEED VALVE IS NOT OPERATIONAL.
C26420
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26349
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE : THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26348
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
P7
P7
CHARACTERIZATION 270
PLUG INSTALLATION 250
SEE FIGURE 3 240
CHARACTERIZATION 250
PLUG INSTALLATION
240 SEE FIGURE 3 250
250 250 260
270
240
230
250 230 260
265
260
230 250
230
260 260
250
220 260 220 250
260
250 230 230 VIEW A
230 20 POST−SB20940
11B 40
VIEW A 10B TUBE ASSY, OIL,
PRE−SB20940 10 SEE 72−01−50
TUBE ASSY, OIL,
FIGURE 18
SEE 72−01−50
50 80 60 FIGURE 3
70 120
P9 30 90
170
130 140
80 110
150 180
60
FWD 190
160 160
170
60
80 200
150
160
100
70
170
A
200 TO 160
FLANGE A P7
C50006C
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
310
320
POST−SB21541
300A J11
360
305 380
280 382
290 360
380 410
340 330 350 382
420
300
P1
PRE−SB21541
380 390
382 370
400
TO TO
P9 D 370
P7 FW
C50007D
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
310
320 12
288
360 J11
384
375
P17 P1
DCU
SEE 72−01−60 345 360
348
FIG. 7
295
384 375
420
335 384
415 810
302
790
305
TO
P9 TO 800
820
P7
POST−SB21764
INSTALLATION
D
FW
PW127M INSTALLATION
C120808C
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
610
TO
P8 620
530 622
540 630 TO
540 P10
600
602
580 590
570
TO P4
AND P14 560 550
TUBE ASSY, PRESSURE
510
SENSING, SEE
520
72−01−30 FIGURE 1
TO 560
J11 565
566
550
430 440
460 434
FWD
480 430
430A
434
P2
460
450A
C50008F
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
780 740
730
730 690
670
640A 680
640 730 690
P5 730
642 710
750
690
690
C50097E
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
REFER TO CAUTION
REPLACE THE EEC WITH ANOTHER. YES
IS THE FAULT CLEARED ?
(REF. 72−01−10)
NO
C129043A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
DISCONNECT THE P2, P17 AND J11 CONNECTORS FROM THE ENGINE
HARNESS. DO A CONTINUITY CHECK FROM THE P17 CONNECTOR PINS
TO THE P2 CONNECTOR PINS AND FROM THE P17 CONNECTOR PINS TO
THE J11 CONNECTOR PINS AS SHOWN BELOW. THE RESULTS SHOULD
BE AS FOLLOWS:
CONTINUITY NO CONTINUITY
NO
P17 [1] TO J11 [Z] P17 [1] & ALL OTHER PINS IN CONNECTOR CASE
P17 [2] TO J11 [ a ] P17 [2] & ALL OTHER PINS IN CONNECTOR CASE
P17 [3] TO P2 [GG] P17 [3] & ALL OTHER PINS IN CONNECTOR CASE
P17 [4] TO P2 [ z ] P17 [4] & ALL OTHER PINS IN CONNECTOR CASE
P17 [5] TO P2 [ k ] P17 [5] & ALL OTHER PINS IN CONNECTOR CASE
P17 [6] TO P2 [ m ] P17 [6] & ALL OTHER PINS IN CONNECTOR CASE
YES
RETURN TO SERVICE
NOTE:
WHEN A NEW DCU IS INSTALLED ON THE ENGINE, YOU MAY
HAVE TO UPDATE THE ACCUMULATED CYCLES IN THE DCU
TO ACCOUNT FOR CYCLES THAT MAY NOT HAVE BEEN
COUNTED BY THE DCU WHILE THE FAULT CODE WAS PRESENT.
C129044
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SET CONDITION
LEVER AT FUEL CUTOFF
POSITION. TURN EEC
POWER OFF. REMOVE YES REPLACE
CONNECTOR P2 FROM EEC
EEC. ARE THERE 28 VDC
ON P2 − s OF ENGINE
HARNESS?
NO
CHECK CONTINUITY.
ENGINE HARNESS NO REPAIR / REPLACE
LINE 134 LESS ENGINE
THAN OR EQUAL TO HARNESS
0.5 OHM?
YES
YES
INVESTIGATE
AIRCRAFT WIRING.
ARE THERE 28 VDC NO
ON ENGINE HARNESS RECTIFY
DISCONNECT P11 − j
WHEN PROPELLER IS
FEATHERED?
YES
SYSTEM NORMAL
C26419A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
INVESTIGATE
AIRCRAFT WIRING TO YES SYSTEM
PLA ENABLE
NORMAL
MICROSWITCHES
(REF. AMM). OK?
C26418
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
CONTINUED ON SHEET 2
C26414
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
C26341
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
YES
CONTINUED ON SHEET 4
C26415
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONTINUED ON SHEET 4
YES
REPLACE AIRCRAFT
TORQUE INDICATOR
(REF. AMM)
C26416
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NO
NO
C26417
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
AIRCRAFT SYSTEM NO
RECTIFY
OK? (REF. AMM)
YES
SYSTEM NORMAL
C26413
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26412
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26411
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
DUAL AIRSPEED INPUT FAULT
(IASIF)
SYMPTOMS SUSPECT LRU
POSSIBLE TORQUE SPLIT 1. EEC AND
POSSIBLE DEGRADE ENGINE AND PROPELLER 2. ADC
PERFORMANCE 3. WIRING
LRU 19
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT IS SET WHEN BOTH ARINC AIRSPEED INPUT FAULT (LRU = 54) AND DELTA
P SENSOR FAULT (LRU = 17) ARE SET.
C26439
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
C26410
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION YES
PLUG (REF. 72−01−10) SYSTEM NORMAL
OK?
NO
REPLACE EEC
(REF. 72−01−10)
OK?
YES
SYSTEM NORMAL
C37697
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
UPTRIM LAMP WRAPAROUND
(LSS4IF)
NO REPAIR / REPLACE
UPTRIM LAMP RELAY OK (REF. AMM)? (REF. AMM)
YES
NO REPLACE WIRING
CONTINUITY ON LINE 133 LESS THAN
HARNESS
OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE UPTRIM LAMP DRIVER SYSTEM IS FOUND TO BE INCORRECT.
C26409
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
C26407
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DIRTY
NO
DISCONNECT P1 AND P8. TEST
REPLACE NO HARNESS LINES 114, 115, 116, 117
HARNESS AND 118 FOR CONTINUITY SHAKING
P8 CONNECTOR
YES
YES
C26408
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
C26406
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26405
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26404
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS. CONTINUITY ON LINES 119, 120, NO
HARNESS
121 AND 122 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26403
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26402
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR /REPLACE
APPLY GROUND TO PIN P11−B (−). IGNITION NO
AIRCRAFT WIRING /
COMES ON (ASSUMING GOOD IGNITERS)?
RELAY (REF. AMM)
YES
YES
NOTE: THIS FAULT IS SET IF EITHER THE AIRCRAFT / ENGINE SYSTEM IS NOT OPERATIONAL
OR THE EEC IS DAMAGED INTERNALLY.
C26401
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO REPAIR /REPLACE
APPLY 28 VDC TO PINS P11−AA (+) AND P11− b (−).
AIRCRAFT WIRING /
MANUAL LAMP OFF?
RELAY (REF. AMM)
YES
NO REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON LINES
ENGINE HARNESS
136 AND 137 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THE VOLTAGE SUPPLIED BY THE EEC TO THE FAIL FIXED RELAY AND THE MFCU STEPPER MOTOR
COMES FROM THE SAME DRIVER. THEREFORE, A SHORT CIRCUIT TO GROUND ON ANY ONE OF
THESE CIRCUITS WILL RESULT IN FAULT CODE LRU 85 BEING SET.
C26400
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 103, NO
HARNESS
104, 128 AND 129 LESS THAN 0.5 OHM?
(REF. 72−01−60)
YES
YES
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO PREVIOUS FAULT
CODES ARE SET FOR ANY OF THE NH PROBES AND THE DIFFERENCE BETWEEN THE TWO
READINGS EXCEEDS 0.9%.
C26399
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS CONTINUITY. RESISTANCE ON LINES NO
ENGINE HARNESS
128 AND 129 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH <30%), NPT IS
ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26398
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 1, PINS J14−3 NO
SENSOR NO. 1
TO J14−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH<30%), NPT
IS ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26397
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, PINS J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
C26396
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
TAKE APPROPRIATE
NH EXCEEDS 110% AND FAULT CODES YES ACTION FOR NH
LRU 12 AND 81 EXIST? OVERSPEED
(REF. 05−50−00)
NO
YES
YES
C26395
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS CONTINUITY. LINES 100, 101 NO
HARNESS
AND 102 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE INLET TEMPERATURE SENSOR LOCATED ON THE REAR INLET CASE
DOES NOT PASS A RANGE CHECK WHEN NH IS ABOVE 66% (I.E. THE ENGINE RUNNING).
C26394
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULT CODES FOR THE
COILS ARE SET AND THE DIFFERENCE BETWEEN THE TWO NPT COIL READINGS EXCEEDS 5%.
C26393
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR / REPLACE
CHECK HARNESS. IS CONTINUITY ON LINES NO
HARNESS
105, 106, 110 AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULTS ARE SET FOR
ANY COILS AND THE DIFFERENCE BETWEEN THE TWO TORQUE COIL READINGS EXCEEDS 5%.
C26392
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: WHEN THIS SIGNAL FAILS, THE EEC WILL DEFAULT TO A TORQUE SHAFT TEMPERATURE OF
80.5 ° C (176.6 ° F). THIS FAULT IS SET IF THE TORQUE TEMPERATURE SIGNAL FAILS TO PASS
A RANGE CHECK.
C26438
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26390
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FOLLOW APPROPRIATE
YES
NP EXCEEDS 135% MAINTENANCE ACTION FOR
NP OVERSPEED (REF. 05−50−00)
NO
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26389
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO. 2.
C26388
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO.2.
C26387
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26437
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO RECONNECT
IS CONNECTOR P1 SECURELY MATED TO J1?
P1 TO EEC
YES
NOTE: THIS FAULT IS SET IF LRU 74/78/84/90 ARE ALL SIMULTANEOUSLY LATCHED. THESE LRU’s
CORRESPOND TO THE TORQUE SHAFT TEMPERATURE, NACELLE AMBIENT TEMPERATURE
AND E1 AND E2 SIGNALS FROM THE RVDT IN THE MFC.
C26436
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26384
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26383
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26382
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26381
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 1 PSIA IN MCL AND MCR RATINGS
AND +− 0.5 PSIA FOR OTHER RATINGS WITH PLA ABOVE 40 DEGREES.
C26380
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 28 ° F IN MCL AND MCR RATINGS
AND +− 14° F FOR OTHER RATINGS, TORQUE OUTPUT IS 90% OF TQBUG, AND PLA IS GREATER THAN
40 DEGREES.
C26379
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26435
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT IS SET IF THE FOLLOWING TORQUE LEVELS ARE MAINTAINED FOR THE CONTINUOUS
PERIODS INDICATED:
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26434
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT OCCURS WHEN THE ENGINE TORQUE IS BETWEEN 122% AND 137% (12800 −14440
LB. FT. ) FOR A CONTINUOUS PERIOD OF TIME GREATER THAN 20 AND LESS THAN 3000 SECONDS,
OR WHEN THE ENGINE TORQUE IS BETWEEN 100% AND 122% (10504−12800 LB. FT.) FOR A
CONTINUOUS PERIOD OF TIME GREATER THAN 600 SECONDS.
C26433
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26378
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26377
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26376
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26374
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND
OUT OF FEATHER SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED
WHEN THE ENGINE IS NOT RUNNING. THIS FAULT IS SET IF THE ARINC INPUT LINK IS
FOUND TO BE INVALID WITH NPT ABOVE 60%.
C26375
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26373
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE WITH
NO
HAS A PW127F MFCU BEEN INSTALLED? CORRECT MFCU
(REF. 72−01−40)
YES
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 124 NO
ENGINE HARNESS
AND 125 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE EEC DOES NOT ACKNOWLEDGE CONTINUITY BETWEEN PINS J2− a
AND J2−D OF THE MFCU. THE PW127, PW127E AND PW127F MFCU’s PROVIDE HIGHER FLOWS
FOR OPERATION AT PW127, PW127E AND PW127F POWERS THAN THE PW124B MFCU.
THESE CONNECTED PINS WITHIN THE MFCU ARE A WAY FOR THE EEC
TO IDENTIFY A PW127, PW127E AND A PW127F MFCU.
C26432A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO A WITHIN +− 0.1% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R1)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C95981A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THE INDICATION TO THE EEC COMES FROM A RANGE CHECK PERFORMED ON
THE OUTPUT WRAPAROUND CIRCUITRY.
REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON NO
ENGINE HARNESS
LINES 112 AND 113 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE EEC
(REF. 72−01−10)
C26431B
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26370
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: NO FAULT CODE IS SET IF THE INTERNAL ARINC DRIVER IS FOUND TO BE DEFECTIVE.
C26369
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26368
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO D WITHIN €±1.0% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R3)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26367B
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHECK CONTINUITY RESISTANCE BETWEEN CHARACTERIZATION
NO PLUG WITH RESISTOR
PINS. C TO E WITHIN ± 1.0% OF VALUE
SHOWN ON PLUG DATA PLATE (R4)? VALUES R1, R3 AND R4
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26366B
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE DRIFT COMPENSATED FOR VARIATIONS IN TEMPERATURE.
THIS FAULT MAY ALSO OCCUR DUE TO AN ELECTRICAL POWER INTERRUPTION OR POWER
SUPPLY VOLTAGE REDUCTION.
C26365
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
ARE BOTH FULT CODES LRU 28 AND 29 YES CARRY OUT CHECK AS PER
ALSO SET? LRU FAULT CODE 28 AND 29
NO
REPLACE EEC
(REF. 72−01−10)
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE PROCESSED AND CONVERTED TO DIGITAL SIGNALS FOR USE
BY THE EEC. EACH SIGNAL IS GAIN COMPENSATED FOR VARIATIONS IN EXCITATION VOLTAGE.
THE GAIN SIGNAL IS CONTINUOUSLY RANGE CHECKED. VALUES OUTSIDE THIS RANGE ARE
CONSIDERED INVALID AND THIS FAULT IS FLAGGED.
C26364
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. AN INTERNAL EEC COLD JUNCTION IS USED TO CORRECT THE GAIN AND THE DRIFT
OF THE EEC PRESSURE TRANSDUCERS FOR THERMAL VARIATIONS.
2. THIS FAULT WILL ALSO SET LRU = 44.
C26430
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DRIFT CORRECTION TO LOW LEVEL (mV) INPUTS IS TO ACCOUNT FOR HARDWARE
AMPLIFIER DRIFT.
C26429
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. LOW LEVEL INPUTS (mV) COMING FROM AMBIENT AND DIFFERENTIAL PRESSURE TRANSDUCERS
ARE GAIN CORRECTED WITHIN THE EEC. THIS GAIN CORRECTION ACCOUNTS FOR STRAIN GAGE
EXCITATION VARIATIONS.
C26428
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DELTA−P PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26427
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. DURING INITIALIZATION, THE EEC LOCATED PRESSURE TRANSDUCER CALIBRATION DATA IS
VERIFIED. IF INVALID, THIS FAULT IS FLAGGED AND THE EEC ASSUMES DEFAULT VALVES.
C26426
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THE STATIC PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26425
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING AMBIENT PRESSURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60& (I.E. NOT ON THE GROUND).
C26424
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING TEMPERATURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60% (I.E. NOT ON THE GROUND).
C26423
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
NO
C26355
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
C26354A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26422
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
REPLACE EEC
(REF. 72−01−10)
C26353
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FUNCTION PERFORMS A GENERAL CHECK ON THE EEC TORQUE CONVERSION PROCESS.
THE CHECK WILL DETECT AN INTERNAL EEC FAILURE OF THE TORQUE / NPT CONVERSION PROCESS.
C26421
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
THIS FAULT IS CAUSED BY A DUAL NH FAILURE AND THE MAINTENANCE PROCEDURE FOR
LRU 12 IS TO BE FOLLOWED.
THIS FAULT SENDS A "DASH−DASH" OUTPUT TO THE COCKPIT ON ARINC LABEL 343 TO TELL
THE PILOT THAT THE INTERCOMPRESSOR BLEED VALVE IS NOT OPERATIONAL.
C26420
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26349
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE : THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26348
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
REFER TO CAUTION
REPLACE THE EEC WITH ANOTHER. YES
IS THE FAULT CLEARED ?
(REF. 72−01−10)
NO
C129043A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
DISCONNECT THE P2, P17 AND J11 CONNECTORS FROM THE ENGINE
HARNESS. DO A CONTINUITY CHECK FROM THE P17 CONNECTOR PINS
TO THE P2 CONNECTOR PINS AND FROM THE P17 CONNECTOR PINS TO
THE J11 CONNECTOR PINS AS SHOWN BELOW. THE RESULTS SHOULD
BE AS FOLLOWS:
CONTINUITY NO CONTINUITY
NO
P17 [1] TO J11 [Z] P17 [1] & ALL OTHER PINS IN CONNECTOR CASE
P17 [2] TO J11 [ a ] P17 [2] & ALL OTHER PINS IN CONNECTOR CASE
P17 [3] TO P2 [GG] P17 [3] & ALL OTHER PINS IN CONNECTOR CASE
P17 [4] TO P2 [ z ] P17 [4] & ALL OTHER PINS IN CONNECTOR CASE
P17 [5] TO P2 [ k ] P17 [5] & ALL OTHER PINS IN CONNECTOR CASE
P17 [6] TO P2 [ m ] P17 [6] & ALL OTHER PINS IN CONNECTOR CASE
YES
RETURN TO SERVICE
NOTE:
WHEN A NEW DCU IS INSTALLED ON THE ENGINE, YOU MAY
HAVE TO UPDATE THE ACCUMULATED CYCLES IN THE DCU
TO ACCOUNT FOR CYCLES THAT MAY NOT HAVE BEEN
COUNTED BY THE DCU WHILE THE FAULT CODE WAS PRESENT.
C129044
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYMPTOMS
ENGINE OVERTORQUE
REFER TO CHAPTER
IS THE MAX. TORQUE AND NO 05−50−00, UNSCHEDULED
DURATION OF THE OVERTORQUE MAINTENANCE INSPECTIONS
KNOWN? (REF. PARA. "ENGINE
OVERTORQUE ESTIMATION")
YES
REFER TO CHAPTER
05−50−00, UNSCHEDULED
MAINTENANCE INSPECTIONS
(REF. PARA. "OVERTORQUE")
C89602
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
IS MAIN OIL FILTER IMPENDING BY−PASS YES REFER TO CHART "MAIN OIL
INDICATOR ACTIVATED ? FILTER IMPENDING BY−PASS
INDICATOR ACTIVATED"
NO
YES
SEE
SHEET 2
C72641
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SEE SEE
SHEET 1 SHEET 1
NO
NO
SYSTEM
NORMAL
NOTE 1: NOTE 2:
C72643
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
ARE HP & FUEL PUMP INLET YES CHANGE THE FUEL HEATER &
FILTERS CONTAMINATED ? THE FUEL PUMP
NO
IS AIRCRAFT FUEL NO
SYSTEM CONTAMINATED ?
YES
C82791
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYMPTOMS
OIL ON FLANGE (S) E AND/OR F
− REFER TO INTERCOMPRESSOR CASE AIR PLENUM BORESCOPE
(REF. 72−00−00, ENGINE−INSPECTION/CHECK)
AND INTERCOMPRESSOR CASE P2.5 CAVITY INSPECTION
(REF. 72−01−50, INSPECTION/CHECK)
NO
CARRY OUT INSPECTION
BORESCOPE ICC AIR YES OF THE ICC P2.5 CAVITY
PLENUM. OIL FOUND ? (REF. 72−01−50)
OK?
NO
YES
SYSTEM NORMAL
SYSTEM NORMAL
C61583B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES NO
SCHEDULE MODULE
VERIFY LOCATION REMOVAL
OF LEAK
EVIDENCE OF CORROSION ON NO
THRUST BEARING COVER ? CONT’D ON
REFER TO PROPELLER
SHEET 2
SYSTEM CMM YES
REPAIR CORROSION; CLEAN SEAL
RUNNER; REPLACE PROP SHAFT CLEAN SEAL RUNNER, REPLACE
SEAL AND INSPECT I.D. OF THE PROP SHAFT SEAL AND INSPECT
SHAFT FOR VISIBLE CRACK INSIDE DIA. OF SHAFT AND
(REF. 72−10−00) OK ? VISIBLE CRACK (REF. 72−10−00) OK ?
YES NO NO YES
SCHEDULE MODULE
SYSTEM REMOVAL SYSTEM
NORMAL NORMAL
C26239B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D
FROM
SHEET 1
SCHEDULE
NO REPLACE THRUST BEARING COVER NO MODULE
EVIDENCE OF CORROSION ? GASKET AND PACKING. OK ? REMOVAL
YES
YES
SYSTEM NORMAL
YES
SYSTEM
NORMAL
C24927
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DEBRIS ANALYZED AT
LABORATORY (TABLE MATERIAL ANALYSIS OF OIL FILTER
SPECIFICATIONS SHOULD BE PATCH CHEAK CONFIRMS YES CONTINUE
CONSULTED TO DETERMINE DEBRIS ONLY IN TRACE IN SERVICE
WHICH COMPONENT IS AMOUNTS
GENERATING DEBRIS).
NO
IS DEBRIS ORIGINATING
WAS DEBRIS BEARING MATERIAL WAS THE RGB FROM ACCESSORIES REPLACE
NO YES YES (PCU GENERATOR OR YES
AMS6444 (52100) / AMS6491 (M50) / GENERATING DEFECTIVE
AMS6414 / AMS6415? DEBRIS? O/S GOVERNOR AND ACCESSORIES.
HYDRAULIC PUMP)?
NO (REF. NOTE 1 & 7)
NO
WAS THE
TURBOMACHINERY REPLACE RGB
GENERATING HAS RGB A RECENT
HISTORY (WITHIN WITHIN 50 FLIGHT
DEBRIS? YES HOURS OF MOST
WAS DEBRIS YES CONTINUE 400 HOURS) OF
GENERATING CURRENTLY
ALLOWABLE? IN SERVICE YES REPORTED DEBRIS.
DEBRIS?
(REF. NOTE 2 & 5)
NO
REPLACE MODULE NO
(REF. NOTE 2)
CONTINUE
IN SERVICE.
(REF. NOTE 4)
CARRY OUT AN INSPECTION (BORESCOPE)
OF THE FOLLOWING COMPONENTS DEPENDING
WHICH MODULE THE DEBRIS WAS FOUND IN
WAS DEBRIS YES (RGB: FIRST−STAGE GEARS; INSPECT RGB
GEAR MATERIAL? TURBOMACHINERY: ANGLE DRIVE GEARBOX CHIP DETECTOR NO CONTINUE
GEARS, OIL PUMP DRIVE GEARS, FUEL PUMP AFTER 50 FLIGHT IN SERVICE.
NO DRIVE GEARS AND STARTER GENERATOR HOURS. IS DEBRIS (REF. NOTE 4)
DRIVE GEARS). (REF. EMM). FOUND?
YES
IS MODULE IN YES
ACCEPTABLE CONTINUE
IN SERVICE REPLACE RGB
CONDITION? WITHIN 50 FLIGHT
HOURS OF MOST
NO CURRENTLY
REPORTED DEBRIS.
REMOVE MODULE (REF. NOTE 2 & 5)
SEE SHEET 2 (REF. NOTE 2)
C74129B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
BORESCOPE ENGINE AS
REQUIRED. (REF. NOTE 7)
REMOVE MODULE.
C74121A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE 1: IT SHOULD HAVE ALREADY BEEN DETERMINED THAT THE RGB AND NOT RGB MOUNTED ACCESSORIES ARE GENERATING
THE DEBRIS.
NOTE 2: AFTER AN ENGINE/MODULE CHANGE DUE TO BEARING/GEAR DISTRESS, IT IS RECOMMENDED THAT THE REPLACEMENT
ENGINE HAVE AN OIL−FILTER PATCH CHECK CARRIED OUT AFTER 50 HOURS. THIS IS TO ENSURE BEARING/GEAR MATERIAL
FROM THE ORIGINAL FAILURE HAS NOT CONTAMINATED THE REPLACEMENT ENGINE DUE TO INCOMPLETE FLUSHING
OF THE AIRFRAME/PROPELLER OIL SYSTEM(S). IF MAGNETIC MATERIAL IS FOUND, REPEAT PATCH CHECK AFTER 50 HOURS.
IF THE AMOUNT OF MATERIAL IS REDUCED, REPEAT PATCH CHECK AT 50−HOUR INTERVALS UNTIL NO MAGNETIC MATERIAL
IS FOUND. THE TIME BETWEEN PATCH CHECKS SHOULD REVERT TO THE STANDARD INTERVAL AFTER THE SECOND
CONSECUTIVE CLEAN PATCH CHECK. IF THE AMOUNT OF MAGNETIC MATERIAL INCREASES OR IF MAGNETIC MATERIAL IS
FOUND AFTER THE SECOND CLEAN PATCH CHECK, THE MAINTENANCE ACTION REQUIRED FOR DEBRIS IN OIL SYSTEM MUST
BE CARRIED OUT.
NOTE 3: IF THE INITIAL PATCH CHECK OR FILTER CHANGE IS CARRIED OUT AT MORE THAN 100 FLIGHT HOURS, THE SEAL MATERIAL
FOUND MAY HAVE BEEN GENERATED AFTER THE RUNNING−IN PERIOD. THEREFORE, AN ADDITIONAL PATCH CHECK MUST
BE CARRIED OUT AFTER APPROXIMATELY ONE WEEK (50 FLIGHT HOURS). CARRY OUT THE INSPECTIONS SHOWN FOR
LABYRINTH SEAL MATERIAL (AMS5504 OR AMS5613 OR AMS5663).
NOTE 4: KEEPING A DEBRIS−GENERATING REDUCTION GEARBOX OR TURBOMACHINERY MODULE IN SERVICE WHILE A REMOVAL IS
PLANNED MAY SUBSTANTIALLY INCREASE THE COST OF REPAIR/REFURBISHMENT DUE TO FURTHER GEAR AND/OR
BEARING DAMAGE.
NOTE 5: AMS6444 (52100) / AMS6491 (M50) MATERIAL IN RGB DEBRIS MAY BE CAUSED BY ELECTRO−EROSION OF NO.15, 18 AND 19
BEARINGS. CHECK PROPELLER DE−ICING SYSTEM IN ACCORDANCE WITH PROPELLER MAINTENANCE DOCUMENTATION.
RECORD AND REPORT RESULTS OF CHECK TO LOCAL P&WC FIELD REPRESENTATIVE.
NOTE 6: THE AMOUNTS OF INDIVIDUAL CONSTITUENTS IN OIL FILTER PATCH DEBRIS AFTER ANALYSIS IS;
MAJOR − WHEN WEIGHT OF THE CONSTITUENT IS MORE THAN 50% OF THE TOTAL DEBRIS WEIGHT.
MINOR − WHEN WEIGHT OF THE CONSTITUENT IS LESS THAN 50% BUT MORE THAN 5% OF THE TOTAL DEBRIS WEIGHT.
TRACES − WHEN WEIGHT OF THE CONSTITUENT IS LESS THAN 5% OF THE TOTAL DEBRIS WEIGHT.
C74130
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DEBRIS ORIGINATES
FROM THE RGB.
NO
YES
CLEAN AND INSTALL FILTERS, WERE THE RESULTS OF THE NO / UNKNOWN IS THE QUANTITY OF DEBRIS
PREVIOUS LABORATORY THE SAME OR INCREASED NO
STRAINERS, CHIP DETECTOR
STRAINERS AND CHIP ANALYSIS BEARING OR IS RGB CONSISTENTLY
DETECTORS. MATERIAL? (NOTE 1 & 6) GENERATING DEBRIS?
YES
C74131B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
IS DEBRIS ORIGINATING REMOVE AND INSPECT OIL
FROM ACCESSORIES FILTERS, STRAINERS, CHIP
(PCU GENERATOR OR YES
DETECTORS AND CHIP
O/S GOVERNOR AND DETECTOR STRAINERS.
HYDRAULIC PUMP)? IS DEBRIS FOUND?
(REF. NOTE 1, 3 & 5)
NO
NO
C74132B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE 1: RESULTS OF PREVIOUS LABORATORY ANALYSIS AND ORIGIN OF DEBRIS SHOULD BE DETERMINED WITHIN 50 FLIGHT HOURS
OF ORIGINAL DETECTION OF DEBRIS.
NOTE 2: RESULTS OF LAST SAMPLE MUST BE KNOWN PRIOR TO CONTINUING FAULT ISOLATION.
NOTE 3: IT SHOULD HAVE ALREADY BEEN DETERMINED THAT THE RGB AND NOT RGB MOUNTED ACCESSORIES ARE GENERATING THE
DEBRIS.
NOTE 4: AFTER AN ENGINE/MODULE CHANGE DUE TO BEARING/GEAR DISTRESS, IT IS RECOMMENDED THAT THE REPLACEMENT
ENGINE HAVE AN OIL−FILTER PATCH CHECK CARRIED OUT AFTER 50 HOURS. THIS IS TO ENSURE BEARING/GEAR MATERIAL
FROM THE ORIGINAL FAILURE HAS NOT CONTAMINATED THE REPLACEMENT ENGINE DUE TO INCOMPLETE FLUSHING
OF THE AIRFRAME/PROPELLER OIL SYSTEM(S). IF MAGNETIC MATERIAL IS FOUND, REPEAT PATCH CHECK AFTER 50 HOURS.
IF THE AMOUNT OF MATERIAL IS REDUCED, REPEAT PATCH CHECK AT 50−HOUR INTERVALS UNTIL NO MAGNETIC MATERIAL
IS FOUND. THE TIME BETWEEN PATCH CHECKS SHOULD REVERT TO THE STANDARD INTERVAL AFTER THE SECOND
CONSECUTIVE CLEAN PATCH CHECK. IF THE AMOUNT OF MAGNETIC MATERIAL INCREASES OR IF MAGNETIC MATERIAL IS
FOUND AFTER THE SECOND CLEAN PATCH CHECK, THE MAINTENANCE ACTION REQUIRED FOR DEBRIS IN OIL SYSTEM MUST
BE CARRIED OUT.
NOTE 5: IT IS POSSIBLE THAT DEBRIS BELIEVED TO BE ORIGINATING FROM RGB MODULE IS, IN FACT, ORIGINATING FROM PROPELLER
CONTROL UNIT (PCU), OVERSPEED GOVERNOR (O/S GOVERNOR), HYDRAULIC PUMP OR FEATHERING PUMP. TO DETERMINE
THE ACTUAL SOURCE OF THE DEBRIS, REFER TO THE LIST OF MATERIAL AND IDENTIFY MOST PROBABLE SOURCE.
ALTERNATELY, REMOVE THESE COMPONENTS INDIVIDUALLY BASED ON THE MOST PROBABLE SOURCE OF DEBRIS. CHECK
CHIP DETECTOR DAILY TO DETERMINE IF THE RGB IS STILL MAKING DEBRIS. IDENTIFY THE SOURCE OF DEBRIS WITHIN 50 HOURS
OF THE ORIGINALLY REPORTED DEBRIS.
NOTE 6: AMS6444 (52100) / AMS6491 (M50) MATERIAL IN RGB DEBRIS MAY BE CAUSED BY ELECTRO−EROSION OF THE NO.15, 18 AND 19
BEARINGS. CHECK PROPELLER DE−ICING SYSTEM IN ACCORDANCE WITH PROPELLER MAINTENANCE DOCUMENTATION.
RECORD AND REPORT RESULTS OF CHECK TO LOCAL P&WC FIELD REPRESENTATIVE.
C74128A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
HAS TURBOMACHINERY A
RECENT HISTORY (WITHIN YES REVIEW THE RESULTS OF
400 HOURS) OF LAST LABORATORY ANALYSIS.
GENERATING DEBRIS? (REF. NOTE 2)
NO
WERE THE RESULTS OF YES REMOVE
THE PREVIOUS LABORATORY TURBOMACHINERY.
ANALYSIS BEARING MATERIAL? (SEE NOTE 3)
(NOTE 1)
CLEAN AND INSTALL FILTERS,
STRAINERS, CHIP DETECTOR NO
STRAINERS AND CHIP
DETECTORS.
REMOVE
RUN ENGINE AT 80% IS THE QUANTITY OF DEBRIS TURBOMACHINERY
THE SAME OR INCREASED OR YES
TORQUE FOR 10 MINUTES. AT FIRST OPPORTUNITY
(REF. AMM) IS MODULE CONSISTENTLY OR WITHIN 10FH
GENERATING DEBRIS? (SEE NOTE 3)
NO
REMOVE AND INSPECT OIL
NO FILTERS, STRAINERS, CHIP
DETECTORS AND CHIP
DETECTOR STRAINERS.
IS DEBRIS FOUND?
YES
C74112
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
REVIEW THE RESULTS OF RETURN ENGINE TO SERVICE AND CHECK REFER TO CHART
LAST LABORATORY ANALYSIS AIRFRAME CONDITION PANEL (IF APPLICABLE) "EVALUATION OF
BEFORE NEXT DISPATCH. YES NO
FOR CHIP DETECTOR CIRCUIT COMPLETION LABORATORY REPORT"
REFER TO CHART "EVALUATION OR REMOVE AND INSPECT CHIP DETECTOR/ WHEN ANALYSIS RESULT
OF LABORATORY REPORT". COLLECTOR DAILY FOR 50 FH. OF MOST CURRENT DEBRIS
(REF. NOTE 1) CHECK OIL FILTERS FOR DEBRIS AFTER IS AVAILABLE.
50 FH (REF. NOTE 1)
IS DEBRIS FOUND ?
C74113A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE 2: RESULTS OF LAST SAMPLE MUST BE KNOWN PRIOR TO CONTINUING FAULT ISOLATION.
C74114A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DETERMINE IF DEBRIS
FOUND IS AN ALLOWABLE
OR A NON−ALLOWABLE
DEBRIS (REF.72−01−50).
IF IT IS A NON−ALLOWABLE
DEBRIS, DETERMINE THE
CATAGORY (REF.72−01−50).
CLEAN AND INSTALL OIL FILTERS,
STRAINER, CHIP DETECTOR RECORD CATAGORY, TYPE REFER TO CHART
YES
IS DEBRIS ALLOWABLE? STRAINERS AND CHIP DETECTORS. AND ORIGIN OF DEBRIS. "EVALUATION OF
RETURN ENGINE TO SERVICE, SEND DEBRIS TO AN LABORATORY REPORT"
PENDING RESULT OF LABORATORY APPROVED LABORATORY.
ANALYSIS.
NO
NO NO
IS DEBRIS NON−ALLOWABLE RECORD CATAGORY, TYPE DEBRIS ORIGINATED IN REFER TO CHART
CATAGORY 1? AND ORIGIN OF DEBRIS. TURBOMACHINERY? "OIL DEBRIS
SEND DEBRIS TO AN FROM RGB"
APPROVED LABORATORY.
YES YES
C74110
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES YES
NO
IS THERE EVIDENCE OF
THE KEYWASHER
FRAGMENT HAVING GONE YES
THROUGH THE GEARTEETH,
THEREBY DAMAGING THE
CONTACTING SURFACE?
NO
NOTE 1:
AFTER AN ENGINE/MODULE CHANGE DUE TO BEARING/GEAR DISTRESS,
IT IS RECOMMENDED THAT THE REPLACEMENT ENGINE HAVE AN OIL−FILTER
PATCH CHECK CARRIED OUT AFTER 50 HOURS. THIS IS TO ENSURE
BEARING/GEAR MATERIAL FROM THE ORIGINAL FAILURE HAS NOT CONTAMINATED
THE REPLACEMENT ENGINE DUE TO INCOMPLETE FLUSHING OF THE
AIRFRAME/PROPELLER OIL SYSTEM(S). IF MAGNETIC MATERIAL IS
FOUND, REPEAT PATCH CHECK AFTER 50 HOURS. IF THE AMOUNT OF
MATERIAL IS REDUCED, REPEAT PATCH CHECK AT 50−HOUR INTERVALS
UNTIL NO MAGNETIC MATERIAL IS FOUND. THE TIME BETWEEN PATCH CHECKS
SHOULD REVERT TO THE STANDARD INTERVAL AFTER THE SECOND
CONSECUTIVE CLEAN PATCH CHECK. IF THE AMOUNT OF MAGNETIC MATERIAL
INCREASES OR IF MAGNETIC MATERIAL IS FOUND AFTER THE SECOND CLEAN
PATCH CHECK, THE MAINTENANCE ACTION REQUIRED FOR DEBRIS IN OIL
SYSTEM MUST BE CARRIED OUT.
C74111A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO NO YES
NO
NO
CONTACT P&WC
YES YES
CONT’D ON CONT’D ON
SHEET 2 (A) SHEET 3 (B)
C76749B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1 (A)
NO NO
CONT’D ON
SHEET 5 (D) PLUG Py LINE AT YES REPLACE Py LINE YES
MFC. START OK? START OK?
FUEL FLOW OR NH SPEED
DECREASES AFTER LIGHT NO NO
NO UP? SYSTEM
NORMAL
YES
PLUG MOTIVE FLOW LINE YES REFER TO AMM FOR REPLACE OVERSPEED
MOTIVE FLOW / GOVERNOR. START OK? YES
AT MFC. START OK? JET PUMP INSPECTION
NO
NO
INSPECT AIRFRAME CONTACT P&WC
DRAIN LINES FOR
DISCONNECT MFC (OR HMU) YES DENTS, BENTS OR
DRAIN (REF. 72−01−40). START OK? BLOCKING (REF. AMM). NO
ARE LINES IN GOOD SERVICE / REPLACE
CONDITION?
AIRFRAME DRAIN
LINES (REF. AMM)
YES
NO
ENGINE STARTS OK?
YES
SYSTEM NORMAL
NO INSPECT GAS GENERATOR
FUEL DRAIN VALVE NO REPLACE FUEL DRAIN VALVE
(REF. 72−01−40). IS VALVE (REF. 72−01−40)
OK?
NO
ENGINE STARTS OK?
YES
YES
SYSTEM NORMAL
CONTACT P&WC
CONT’D ON
SHEET 3
C76750C
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1 (B)
CONT’D FROM
SHEET 2
YES SYSTEM
NORMAL
FUEL DRAINING FROM YES REPLACE FLOW DIVIDER
FLOW DIVIDER AND DUMP AND DUMP VALVE.
VALVE DURING START? START OK?
NO
CONTACT P&WC
NO
NO NO
CONTACT P&WC
C130903
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 3 (C)
NO
YES
NO
NO
NO
YES
REPLACE FUEL NOZZLES SYSTEM NORMAL
START OK?
NO
CONTACT P&WC
C76751B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 2 (D)
NO NO
NO
NO
CONTACT P&WC
YES
CONTACT P&WC
C76752A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES NO
YES
C26236E
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DELETED
C00000
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
ANY HISTORY OF
IS MAIN OIL FILTER NO MAIN OIL FILTER YES
BYPASS INDICATOR REPLACE BYPASS INDICATOR
CONTAMINATED ? ACTIVATED IN THE
LAST 50 FH ?
YES
C26235E
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DELETED
C00000
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
TROUBLESHOOT NO
(REF. DEBRIS IN INDICATING
SYSTEM OK? RECTIFY
OIL SYSTEM)
YES
SYSTEM NORMAL
C25401
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NOTE:
WHEN THE ENGINE HAS COOLED AND THE TEMPERATURE EQUALIZED, P.T. STATOR DISTORTION AND TIGHT TIP
CLEARANCES CAN CAUSE BLADE RUBBING. THIS IS NORMAL AND USUALLY DISAPPEARS DURING ENGINESTART.
A BORESCOPE INSPECTION SHOULD BE CARRIED OUT THE FIRST TIME A PROPELLER DOES NOT ROTATE MANUALLY
OR WHEN THE BEHAVIOR OF THE PROPELLER DURING START−UP/SHUTDOWN DEVIATES FROM ITS USUAL PATTERN.
C25382B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO NO RECTIFY OR
AIR SYSTEM LP COMPRESSOR REPLACE
OK ? BLEED SHROUD OK? (REF. 72−30−00)
YES YES
NO RECTIFY OR
INTERCOMPRESSOR BLEED
REPLACE
VALVE SERVO VALVE OK ?
(REF. 72−01−30)
YES
YES
NO RECTIFY OR
ENGINE NACELLE INTAKE, DEICER BOOT REPLACE
& OIL COOLER FLAPS OK? (REF. 72−01−30)
C26233B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO NO RECTIFY
FUEL SYSTEM OK ? P3 LINE TO MFCU OK ?
(REF. 72−01−30)
YES YES
C26234B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
CABLES AND NO RECTIFY OR
CONNECTIONS OK ? REPLACE
(REF. AMM)
YES
RECTIFY OR
T6 WIRING HARNESS NO
REPLACE
OK ? (REF. 72−01−60)
YES
NO REPLACE
TRIM RESISTER OK ?
(REF. 72−01−60)
YES
SYSTEM NORMAL
NO REPLACE
THERMOCOUPLES OK ?
(REF. 72−01−60)
C74845
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO INTERCOMPRESSOR BLEED NO
AIR BLEED REPLACE
VALVE AND SERVO VALVE
SYSTEM OK ? (REF. 72−01−30)
OK ?
YES YES
NO REPLACE
SYSTEM NORMAL P2.5 CHECK VALVE OK ? (REF. 72−30−00)
YES
NO
SYSTEM NORMAL
C26232
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SLOW OIL PRESSURE BUILDUP AFTER 1. OIL PRESSURE REGULATING VALVE RESTRICTOR
40% NH DURING STARTING 2. OILPRESSURE CHECK VALVE
3. OIL PRESSURE REGULATING VALVE
4. OIL PRESSURE GAGE
5. AIRFRAME WIRING HARNESS
6. OIL PRESSURE TRANSDUCER
NO NO RECHECK AT
OIL TEMPERATURE
OIL SYSTEM OK ? HIGHER OIL
OK ?
TEMPERATURES
YES YES
YES
OIL PRESSURE NO NO
GAGE OK ? RECTIFY OR REPLACE
INDICATING
(REF. AMM)
SYSTEM OK ?
YES
YES
YES
SYSTEM NORMAL
C26229A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
INVESTIGATE NP
ALL OTHER ENGINE YES
INDICATING SYSTEM
PARAMETERS STABLE ?
(REF. AMM)
NO
YES YES
C26228
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: BEFORE STARTING ENGINE, REFER TO OVERTEMPERATURE CHART (REF. 05−10−00) TO ENSURE
TEMPERATURE LIMITS HAVE NOT BEEN EXCEEDED.
YES
YES REMOVE
ENGINE INLET OBSTRUCTED ? OBSTRUCTION
NO
YES REPLACE EEC YES
ENGINE STARTS NORMALLY (REF. 72−01−10) SYSTEM NORMAL
IN MANUAL ? START OK ?
NO
NO
WIRING HARNESS YES CHANGE MFCU
OK ? (REF. 72−01−40)
CONT"D ON SHEET 2
NO
REPAIR/REPLACE
(REF. 72−01−10)
C26226A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
NO RECTIFY
STARTER POWER SUPPLY OK ? (REF. AMM)
YES
YES
CHANGE MFCU
(REF. 72−01−40)
SYSTEM NORMAL
C26227A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
CONT’D ON
IS PARAMETER SHIFT SHEET 3
CONSIDERED NORMAL FOR YES CARRY OUT RECOMMENDED
ENGINE RUNNING TIME PREVENTATIVE MAINTENANCE
(SEE NOTE 1)? (SEE NOTE 3)
NO
CONT’D ON
SHEET 2
C25389
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SIGNIFICANT DIFFERENCE
BETWEEN ECTM AND POWER YES AIR BLEED SYSTEM NO
ASSURANCE PARAMETER RECTIFY
PRESSURE REGULATING (REF. AMM)
SHIFTS RECORDED VALVE OK?
(SEE NOTE 5)?
YES
NO
YES
NO
YES
SYSTEM NORMAL
C25390
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
TROUBLESHOOT
(REF. SHEETS 4 AND 5)
NO
YES
SYSTEM NORMAL
C25391
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
ENGINE PARAMETERS
ACTION
ITT/T6 NH NL WF PROBABLE DEFECT REQUIRED REMARKS
C20168B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C35198
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C35199A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
SYSTEM NORMAL
NO NO REPLACE
OIL SUPPLY OK ? PCU OK ? (REF. AMM)
YES YES
NO REPLACE
SYSTEM NORMAL PCU PUMP OK ? (REF. 72−01−50)
C26225
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES YES
CONT’D ON SHEET 2
C26223A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
SYSTEM NORMAL
C26224A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
INDICATING NO NO REPLACE
GAGE OK?
SYSTEM OK ? (REF. AMM)
YES
YES
RECTIFY OR
CABLES AND NO
REPLACE
CONNECTIONS OK ?
(REF. AMM)
YES
NO REPLACE
SYSTEM NORMAL FLOWMETER OK? (REF. AMM)
ELECTRONIC FUEL
NO RECTIFY
CONTROL SYSTEM
(REF. 72−01−40)
OK ?
YES
NO RECTIFY OR
SYSTEM NORMAL FLOW DIVIDER AND REPLACE
DUMP VALVE OK?
(REF. 72−01−40)
YES
C26222
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
SYSTEM NORMAL
C25414
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
FLUCTUATIONS ON TORQUE
INDICATOR (REF. NOTE 1)?
YES
CONT’D ON SHEET 2
C27376
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYSTEM NORMAL
YES
REPLACE EEC
(REF. 72−01−10)
C27377
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FLUCTUATIONS CONTINUE NO
CONT’D FROM SHEET 1 CONT’D ON SHEET 4
IN MANUAL MODE?
YES
YES
YES
NO REPAIR / REPLACE
CHECK P3 SUPPLY LINE TUBE. OK?
TO MFC. OK? (REF. 72−01−30)
YES
YES
CHANGE MFC. OK? YES
SYSTEM NORMAL SYSTEM NORMAL
(REF. 72−01−40)
NO
NO REPAIR / REPLACE
CHANGE FUEL PUMP. FUEL PUMP OK?
OK? (REF. 72−01−40) (REF. 72−01−40)
YES
YES
C27378
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
NO
NO
C27379
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C27380
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
(a) (b)
REPLACE AFU.
DO EEC FAULTS AS FOLLOWS: YES SYSTEM
READING OK ?
PW124B: LRU FAULT CODES NORMAL
YES (REF. 72−01−10)
09/28/29/31/69 OR 74 RECTIFY
PW127/127E/127F/127M:
LRU FAULT CODES NO
09/28/29/31/61 OR 74
NO
CHARACTERIZATION PLUG NO
TO CORRECT VALUE ? REPLACE
(SEE DATA PLATE)
YES YES
REPLACE EEC (REF. 72−01−10) SYSTEM
READING OK ? NORMAL
NO INVESTIGATE
REDUCTION GEARBOX
TORQUE SHAFTS
INVESTIGATE REDUCTION
GEARBOX TORQUE SHAFTS
C26220B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
AIRFRAME AIR−COOLED NO AIR−COOLED
SYSTEM NORMAL OIL COOLER OK? OIL COOLER
(REF. AMM)
TEMPERATURE NO REPLACE
INDICATING SYSTEM GAGE OK? (REF. AMM)
OK?
YES
YES
NO RECTIFY OR
CABLES AND REPLACE
CONNECTIONS OK? (REF. AMM)
YES
C25399
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO RECTIFY OR
CABLES AND REPLACE
CONNECTION OK? (REF. AMM)
YES
NO ADJUST OR REPLACE
PRESSURE REGULATING (REF. ADJUSTMENT/TEST
VALVE OK? OR 72−01−50)
YES
SYSTEM NORMAL
YES
SYSTEM NORMAL
C25398
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO NO
OIL PRESSURE GAGE OK?
INDICATING SYSTEM
OK? (REF. AMM)
YES
CABLES AND NO
CONNECTIONS RECTIFY (REF.AMM)
OK?
YES
OIL PRESSURE
TRANSDUCER (LOW
OIL PRESSURE
SWITCH) OK? NO
1
2
C139709
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
1 2
NO
NO
NO
REPLACE CRACKED
EXTERNAL TUBES. VERIFY
AND IF REQUIRED,
RE−ESTABLISH OIL LEVEL.
(REF. 72−00−00)
4 5
C139710
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
3 4 5
NO
C139711
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
6 7
NO
8 9
C139712
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
8 9
NO NO
10 11
C139713
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
10 11
YES
RUN THE ENGINE AT
HIGH POWER FOR A YES
MINIMUM OF 5 MINUTES.
IS THE OIL PRESSURE
WITHIN LIMITS?
NO
C139714
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
ADJUST/REPLACE OIL
YES PRESSURE REGULATING VALVE YES
OIL PRESSURE TOO HIGH ? SYSTEM NORMAL
(REF. 72−01−50).
OIL PRESSURE OK ?
NO
NO
CONT’D ON CONT’D ON
SHEET 2 SHEET 2
C26217B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO REPAIR/REPLACE AS YES
EXAMINE P2.5/P3
NECESSARY SYSTEM NORMAL
SWITCHING VALVE. OK ?
(REF. 72−30−00). OK ?
YES
NO
YES
YES
CONT’D ON
SHEET 3
C26218B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 2
BORESCOPE FIRST−STAGE
PT BLADES TO CHECK FOR
IMPACT DAMAGE TO LEADING NO REMOVE ENGINE FOR INVESTIGATION
EDGES AND/OR TIPS, BLADE (REF. REMOVAL/INSTALLATION)
SHIFT, RUBS, OIL STAINS/
COKING. OK ?
YES
NO
SEE NOTE
NOTE: INABILITY TO IDENTIFY AND/OR RECTIFY THE FAULT AFTER CARRYING OUT THE
LISTED CHECKS INDICATES INTERNAL ENGINE DAMAGE/OIL LEAKAGE. REMOVE
ENGINE FOR INVESTIGATION.
C26219A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
3. OVER−SERVICING
5. OIL COOLER
8. AGB BREATHER
C62152
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO NO
NO NO SYSTEM
NORMAL
NO
NO
CONT’D ON
SHEET 3
C62151
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 2
SYSTEM NORMAL
PW124B (PRE−SB21136) INVESTIGATE (REF. 72−01−50, YES
OIL FOUND IN YES
INSPECTION/CHECK); OIL
INTERCOMPRESSOR CONSUMPTION OK ?
CASE P2.5 PLENUM ?
NO
NO
NO NO
NO
CONT’D ON
SHEET 4
C62124
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 3
NOTE 2: REMOVE AGB BREATHER PIPE AND VISUALLY INSPECT FOR BLOCKAGE.
NOTE 3: ADAPTER ASSEMBLIES MUST BE CHECKED TO ENSURE THE ADJUSTING SPACER THICKNESS IS
CORRECT AND THE SEAL IS SERVICEABLE. USE A 0.001 IN. (0.025mm) FEELER GAGE TO
ENSURE NO CLEARANCE EXISTS BETWEEN THE ADAPTER/SPACER/SEAL OVER 360 DEGREES. REFER
TO CHAPTER 72−20−00 FOR SPACER THICKNESS CALCULATION AND INSPECTION CRITERIA FOR
CARBON SEAL AND MATING GEARSHAFT SEALING FACE.
NOTE 4: LOOK INSIDE CENTRIFUGAL BREATHER SHAFT TO CHECK THAT THE AGB BREATHER ADAPTER AIR
WINDOWS ARE NOT OBSTRUCTED BY THE AGB STOP SHAFT PLUG (REF. 72−30−00). USE
FLASHLIGHT TO ILLUMINATE CAVITY INSIDE THE SHAFT. CHECK SEAL MATING SURFACE ON
SHAFT FOR DAMAGE.
NOTE 5: VISUALLY CHECK THE AIR SWITCHING VALVE PLUNGER "IN SITU" PRIOR TO ENGINE START−UP.
IT SHOULD BE PROTRUDING BY LESS THAN 0.250 in. IF MORE,
SUSPECT PLUNGER STUCK ON P2.5 (REMOVE COVER AND INSPECT).
N.B.: SPRING PRESSURE SHOULD HOLD THE PLUNGER DOWN (P3 POSITION) UNTIL SUFFICIENT P2.5
IS AVAILABLE AFTER START.
REMOVE COVER AND VISUALLY CHECK THE PLUNGER FOR BEND, SCORING, FREEDOM OF
MOVEMENT, ETC.
NOTE 6: INABILITY TO IDENTIFY AND/OR RECTIFY HIGH OIL CONSUMPTION (ABOVE MAX LIMIT) AFTER
CARRYING OUT THE LISTED CHECKS INDICATES INTERNAL ENGINE DAMAGE/OIL LEAKAGE.
REMOVE ENGINE FOR INVESTIGATION.
NOTE 7: MAXIMUM OIL CONSUMPTION PERMISSIBLE IS 0.50 lbs/hr (0.227 kg/hr), WHICH IS
EQUIVALENT TO 0.270 QUART/HOUR (0.250 LITERS/HOUR).
C27410C
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONTACT P&WC
C26212B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
COND’T FROM
SHEET 1
SYSTEM NORMAL
C28474B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE IGNITION
EXCITER. YES
SYSTEM NORMAL
(REF. 72−01−20)
START OK ?
NO
CHECK/REPLACE IGNITER
LEADS (REF. 72−01−20)
C26213
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
STARTER CONTACT NO
RECTIFY
BREAKER IN ?
YES
YES
REMOVE STARTER
YES REPLACE STARTER
(REF. AMM)
(REF. AMM)
HP ROTOR ROTATES ?
NO
REPLACE
TURBOMACHINERY
(REF. 72−02−00)
NH INDICATOR OK ? NO
RECTIFY
(REF. AMM)
(REF. AMM)
YES
REPLACE STARTER
(REF. AMM)
C26214
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
C25388
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
SYSTEM NORMAL NO
TURN ON HP BLEEDS. POWER EQUAL ?
YES
SYSTEM NORMAL
NO
YES
NO REPAIR/REPLACE
P11−CC TO BLEED SWITCH 1, AND
AIRCRAFT WIRING
BLEED SWITCH 1 TO BREAKER OK ?
(REF. AMM)
YES
SYSTEM NORMAL
C26211B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES YES
YES
YES
C26210
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYMPTOM 1.
YES YES
SYMPTOM 2.
REPLACE MFCU
(REF. 72−01−40)
C26209B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO RECTIFY OR
ENGINE WIRING REPLACE
HARNESS OK? (REF. 72−01−10)
YES
C26208
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
REFER TO CAUTION
REPLACE THE EEC WITH ANOTHER. YES
IS THE FAULT CLEARED ?
(REF. 72−01−10)
NO
C129043A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
DISCONNECT THE P2, P17 AND J11 CONNECTORS FROM THE ENGINE
HARNESS. DO A CONTINUITY CHECK FROM THE P17 CONNECTOR PINS
TO THE P2 CONNECTOR PINS AND FROM THE P17 CONNECTOR PINS TO
THE J11 CONNECTOR PINS AS SHOWN BELOW. THE RESULTS SHOULD
BE AS FOLLOWS:
CONTINUITY NO CONTINUITY
NO
P17 [1] TO J11 [Z] P17 [1] & ALL OTHER PINS IN CONNECTOR CASE
P17 [2] TO J11 [ a ] P17 [2] & ALL OTHER PINS IN CONNECTOR CASE
P17 [3] TO P2 [GG] P17 [3] & ALL OTHER PINS IN CONNECTOR CASE
P17 [4] TO P2 [ z ] P17 [4] & ALL OTHER PINS IN CONNECTOR CASE
P17 [5] TO P2 [ k ] P17 [5] & ALL OTHER PINS IN CONNECTOR CASE
P17 [6] TO P2 [ m ] P17 [6] & ALL OTHER PINS IN CONNECTOR CASE
YES
RETURN TO SERVICE
NOTE:
WHEN A NEW DCU IS INSTALLED ON THE ENGINE, YOU MAY
HAVE TO UPDATE THE ACCUMULATED CYCLES IN THE DCU
TO ACCOUNT FOR CYCLES THAT MAY NOT HAVE BEEN
COUNTED BY THE DCU WHILE THE FAULT CODE WAS PRESENT.
C129044
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SET CONDITION
LEVER AT FUEL CUTOFF
POSITION. TURN EEC
POWER OFF. REMOVE YES REPLACE
CONNECTOR P2 FROM EEC
EEC. ARE THERE 28 VDC
ON P2 − s OF ENGINE
HARNESS?
NO
CHECK CONTINUITY.
ENGINE HARNESS NO REPAIR / REPLACE
LINE 134 LESS ENGINE
THAN OR EQUAL TO HARNESS
0.5 OHM?
YES
YES
INVESTIGATE
AIRCRAFT WIRING.
ARE THERE 28 VDC NO
ON ENGINE HARNESS RECTIFY
DISCONNECT P11 − j
WHEN PROPELLER IS
FEATHERED?
YES
SYSTEM NORMAL
C26419A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
INVESTIGATE
AIRCRAFT WIRING TO YES SYSTEM
PLA ENABLE
NORMAL
MICROSWITCHES
(REF. AMM). OK?
C26418
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
CONTINUED ON SHEET 2
C26414
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
C26341
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
YES
CONTINUED ON SHEET 4
C26415
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONTINUED ON SHEET 4
YES
REPLACE AIRCRAFT
TORQUE INDICATOR
(REF. AMM)
C26416
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NO
NO
C26417
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
AIRCRAFT SYSTEM NO
RECTIFY
OK? (REF. AMM)
YES
SYSTEM NORMAL
C26413
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26412
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26411
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
DUAL AIRSPEED INPUT FAULT
(IASIF)
SYMPTOMS SUSPECT LRU
POSSIBLE TORQUE SPLIT 1. EEC AND
POSSIBLE DEGRADE ENGINE AND PROPELLER 2. ADC
PERFORMANCE 3. WIRING
LRU 19
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT IS SET WHEN BOTH ARINC AIRSPEED INPUT FAULT (LRU = 54) AND DELTA
P SENSOR FAULT (LRU = 17) ARE SET.
C26439
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
C26410
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION YES
PLUG (REF. 72−01−10) SYSTEM NORMAL
OK?
NO
REPLACE EEC
(REF. 72−01−10)
OK?
YES
SYSTEM NORMAL
C37697
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
UPTRIM LAMP WRAPAROUND
(LSS4IF)
NO REPAIR / REPLACE
UPTRIM LAMP RELAY OK (REF. AMM)? (REF. AMM)
YES
NO REPLACE WIRING
CONTINUITY ON LINE 133 LESS THAN
HARNESS
OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE UPTRIM LAMP DRIVER SYSTEM IS FOUND TO BE INCORRECT.
C26409
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
C26407
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DIRTY
NO
DISCONNECT P1 AND P8. TEST
REPLACE NO HARNESS LINES 114, 115, 116, 117
HARNESS AND 118 FOR CONTINUITY SHAKING
P8 CONNECTOR
YES
YES
C26408
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
C26406
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26405
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26404
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS. CONTINUITY ON LINES 119, 120, NO
HARNESS
121 AND 122 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26403
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26402
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR /REPLACE
APPLY GROUND TO PIN P11−B (−). IGNITION NO
AIRCRAFT WIRING /
COMES ON (ASSUMING GOOD IGNITERS)?
RELAY (REF. AMM)
YES
YES
NOTE: THIS FAULT IS SET IF EITHER THE AIRCRAFT / ENGINE SYSTEM IS NOT OPERATIONAL
OR THE EEC IS DAMAGED INTERNALLY.
C26401
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO REPAIR /REPLACE
APPLY 28 VDC TO PINS P11−AA (+) AND P11− b (−).
AIRCRAFT WIRING /
MANUAL LAMP OFF?
RELAY (REF. AMM)
YES
NO REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON LINES
ENGINE HARNESS
136 AND 137 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THE VOLTAGE SUPPLIED BY THE EEC TO THE FAIL FIXED RELAY AND THE MFCU STEPPER MOTOR
COMES FROM THE SAME DRIVER. THEREFORE, A SHORT CIRCUIT TO GROUND ON ANY ONE OF
THESE CIRCUITS WILL RESULT IN FAULT CODE LRU 85 BEING SET.
C26400
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 103, NO
HARNESS
104, 128 AND 129 LESS THAN 0.5 OHM?
(REF. 72−01−60)
YES
YES
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO PREVIOUS FAULT
CODES ARE SET FOR ANY OF THE NH PROBES AND THE DIFFERENCE BETWEEN THE TWO
READINGS EXCEEDS 0.9%.
C26399
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS CONTINUITY. RESISTANCE ON LINES NO
ENGINE HARNESS
128 AND 129 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH <30%), NPT IS
ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26398
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 1, PINS J14−3 NO
SENSOR NO. 1
TO J14−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH<30%), NPT
IS ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26397
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, PINS J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
C26396
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
TAKE APPROPRIATE
NH EXCEEDS 110% AND FAULT CODES YES ACTION FOR NH
LRU 12 AND 81 EXIST? OVERSPEED
(REF. 05−50−00)
NO
YES
YES
C26395
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS CONTINUITY. LINES 100, 101 NO
HARNESS
AND 102 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE INLET TEMPERATURE SENSOR LOCATED ON THE REAR INLET CASE
DOES NOT PASS A RANGE CHECK WHEN NH IS ABOVE 66% (I.E. THE ENGINE RUNNING).
C26394
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULT CODES FOR THE
COILS ARE SET AND THE DIFFERENCE BETWEEN THE TWO NPT COIL READINGS EXCEEDS 5%.
C26393
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR / REPLACE
CHECK HARNESS. IS CONTINUITY ON LINES NO
HARNESS
105, 106, 110 AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULTS ARE SET FOR
ANY COILS AND THE DIFFERENCE BETWEEN THE TWO TORQUE COIL READINGS EXCEEDS 5%.
C26392
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: WHEN THIS SIGNAL FAILS, THE EEC WILL DEFAULT TO A TORQUE SHAFT TEMPERATURE OF
80.5 ° C (176.6 ° F). THIS FAULT IS SET IF THE TORQUE TEMPERATURE SIGNAL FAILS TO PASS
A RANGE CHECK.
C26438
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26390
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FOLLOW APPROPRIATE
YES
NP EXCEEDS 135% MAINTENANCE ACTION FOR
NP OVERSPEED (REF. 05−50−00)
NO
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26389
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO. 2.
C26388
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO.2.
C26387
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26437
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO RECONNECT
IS CONNECTOR P1 SECURELY MATED TO J1?
P1 TO EEC
YES
NOTE: THIS FAULT IS SET IF LRU 74/78/84/90 ARE ALL SIMULTANEOUSLY LATCHED. THESE LRU’s
CORRESPOND TO THE TORQUE SHAFT TEMPERATURE, NACELLE AMBIENT TEMPERATURE
AND E1 AND E2 SIGNALS FROM THE RVDT IN THE MFC.
C26436
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26384
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26383
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26382
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26381
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 1 PSIA IN MCL AND MCR RATINGS
AND +− 0.5 PSIA FOR OTHER RATINGS WITH PLA ABOVE 40 DEGREES.
C26380
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 28 ° F IN MCL AND MCR RATINGS
AND +− 14° F FOR OTHER RATINGS, TORQUE OUTPUT IS 90% OF TQBUG, AND PLA IS GREATER THAN
40 DEGREES.
C26379
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26435
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT IS SET IF THE FOLLOWING TORQUE LEVELS ARE MAINTAINED FOR THE CONTINUOUS
PERIODS INDICATED:
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26434
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT OCCURS WHEN THE ENGINE TORQUE IS BETWEEN 122% AND 137% (12800 −14440
LB. FT. ) FOR A CONTINUOUS PERIOD OF TIME GREATER THAN 20 AND LESS THAN 3000 SECONDS,
OR WHEN THE ENGINE TORQUE IS BETWEEN 100% AND 122% (10504−12800 LB. FT.) FOR A
CONTINUOUS PERIOD OF TIME GREATER THAN 600 SECONDS.
C26433
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26378
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26377
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26376
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26374
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND
OUT OF FEATHER SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED
WHEN THE ENGINE IS NOT RUNNING. THIS FAULT IS SET IF THE ARINC INPUT LINK IS
FOUND TO BE INVALID WITH NPT ABOVE 60%.
C26375
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26373
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE WITH
NO
HAS A PW127F MFCU BEEN INSTALLED? CORRECT MFCU
(REF. 72−01−40)
YES
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 124 NO
ENGINE HARNESS
AND 125 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE EEC DOES NOT ACKNOWLEDGE CONTINUITY BETWEEN PINS J2− a
AND J2−D OF THE MFCU. THE PW127, PW127E AND PW127F MFCU’s PROVIDE HIGHER FLOWS
FOR OPERATION AT PW127, PW127E AND PW127F POWERS THAN THE PW124B MFCU.
THESE CONNECTED PINS WITHIN THE MFCU ARE A WAY FOR THE EEC
TO IDENTIFY A PW127, PW127E AND A PW127F MFCU.
C26432A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO A WITHIN +− 0.1% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R1)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C95981A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THE INDICATION TO THE EEC COMES FROM A RANGE CHECK PERFORMED ON
THE OUTPUT WRAPAROUND CIRCUITRY.
REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON NO
ENGINE HARNESS
LINES 112 AND 113 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE EEC
(REF. 72−01−10)
C26431B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26370
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: NO FAULT CODE IS SET IF THE INTERNAL ARINC DRIVER IS FOUND TO BE DEFECTIVE.
C26369
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26368
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO D WITHIN €±1.0% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R3)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26367B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHECK CONTINUITY RESISTANCE BETWEEN CHARACTERIZATION
NO PLUG WITH RESISTOR
PINS. C TO E WITHIN ± 1.0% OF VALUE
SHOWN ON PLUG DATA PLATE (R4)? VALUES R1, R3 AND R4
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26366B
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE DRIFT COMPENSATED FOR VARIATIONS IN TEMPERATURE.
THIS FAULT MAY ALSO OCCUR DUE TO AN ELECTRICAL POWER INTERRUPTION OR POWER
SUPPLY VOLTAGE REDUCTION.
C26365
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
ARE BOTH FULT CODES LRU 28 AND 29 YES CARRY OUT CHECK AS PER
ALSO SET? LRU FAULT CODE 28 AND 29
NO
REPLACE EEC
(REF. 72−01−10)
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE PROCESSED AND CONVERTED TO DIGITAL SIGNALS FOR USE
BY THE EEC. EACH SIGNAL IS GAIN COMPENSATED FOR VARIATIONS IN EXCITATION VOLTAGE.
THE GAIN SIGNAL IS CONTINUOUSLY RANGE CHECKED. VALUES OUTSIDE THIS RANGE ARE
CONSIDERED INVALID AND THIS FAULT IS FLAGGED.
C26364
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. AN INTERNAL EEC COLD JUNCTION IS USED TO CORRECT THE GAIN AND THE DRIFT
OF THE EEC PRESSURE TRANSDUCERS FOR THERMAL VARIATIONS.
2. THIS FAULT WILL ALSO SET LRU = 44.
C26430
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DRIFT CORRECTION TO LOW LEVEL (mV) INPUTS IS TO ACCOUNT FOR HARDWARE
AMPLIFIER DRIFT.
C26429
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. LOW LEVEL INPUTS (mV) COMING FROM AMBIENT AND DIFFERENTIAL PRESSURE TRANSDUCERS
ARE GAIN CORRECTED WITHIN THE EEC. THIS GAIN CORRECTION ACCOUNTS FOR STRAIN GAGE
EXCITATION VARIATIONS.
C26428
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DELTA−P PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26427
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. DURING INITIALIZATION, THE EEC LOCATED PRESSURE TRANSDUCER CALIBRATION DATA IS
VERIFIED. IF INVALID, THIS FAULT IS FLAGGED AND THE EEC ASSUMES DEFAULT VALVES.
C26426
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THE STATIC PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26425
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING AMBIENT PRESSURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60& (I.E. NOT ON THE GROUND).
C26424
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING TEMPERATURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60% (I.E. NOT ON THE GROUND).
C26423
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
NO
C26355
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
C26354A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26422
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
REPLACE EEC
(REF. 72−01−10)
C26353
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FUNCTION PERFORMS A GENERAL CHECK ON THE EEC TORQUE CONVERSION PROCESS.
THE CHECK WILL DETECT AN INTERNAL EEC FAILURE OF THE TORQUE / NPT CONVERSION PROCESS.
C26421
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
THIS FAULT IS CAUSED BY A DUAL NH FAILURE AND THE MAINTENANCE PROCEDURE FOR
LRU 12 IS TO BE FOLLOWED.
THIS FAULT SENDS A "DASH−DASH" OUTPUT TO THE COCKPIT ON ARINC LABEL 343 TO TELL
THE PILOT THAT THE INTERCOMPRESSOR BLEED VALVE IS NOT OPERATIONAL.
C26420
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26349
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE : THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26348
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
P7
P7
CHARACTERIZATION 270
PLUG INSTALLATION 250
SEE FIGURE 3 240
CHARACTERIZATION 250
PLUG INSTALLATION
240 SEE FIGURE 3 250
250 250 260
270
240
230
250 230 260
265
260
230 250
230
260 260
250
220 260 220 250
260
250 230 230 VIEW A
230 20 POST−SB20940
11B 40
VIEW A 10B TUBE ASSY, OIL,
PRE−SB20940 10 SEE 72−01−50
TUBE ASSY, OIL,
FIGURE 18
SEE 72−01−50
50 80 60 FIGURE 3
70 120
P9 30 90
170
130 140
80 110
150 180
60
FWD 190
160 160
170
60
80 200
150
160
100
70
170
A
200 TO 160
FLANGE A P7
C50006C
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
310
320
POST−SB21541
300A J11
360
305 380
280 382
290 360
380 410
340 330 350 382
420
300
P1
PRE−SB21541
380 390
382 370
400
TO TO
P9 D 370
P7 FW
C50007D
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
310
320 12
288
360 J11
384
375
P17 P1
DCU
SEE 72−01−60 345 360
348
FIG. 7
295
384 375
420
335 384
415 810
302
790
305
TO
P9 TO 800
820
P7
POST−SB21764
INSTALLATION
D
FW
PW127M INSTALLATION
C120808C
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
610
TO
P8 620
530 622
540 630 TO
540 P10
600
602
580 590
570
TO P4
AND P14 560 550
TUBE ASSY, PRESSURE
510
SENSING, SEE
520
72−01−30 FIGURE 1
TO 560
J11 565
566
550
430 440
460 434
FWD
480 430
430A
434
P2
460
450A
C50008F
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
780 740
730
730 690
670
640A 680
640 730 690
P5 730
642 710
750
690
690
C50097E
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
REFER TO CAUTION
REPLACE THE EEC WITH ANOTHER. YES
IS THE FAULT CLEARED ?
(REF. 72−01−10)
NO
C129043A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
DISCONNECT THE P2, P17 AND J11 CONNECTORS FROM THE ENGINE
HARNESS. DO A CONTINUITY CHECK FROM THE P17 CONNECTOR PINS
TO THE P2 CONNECTOR PINS AND FROM THE P17 CONNECTOR PINS TO
THE J11 CONNECTOR PINS AS SHOWN BELOW. THE RESULTS SHOULD
BE AS FOLLOWS:
CONTINUITY NO CONTINUITY
NO
P17 [1] TO J11 [Z] P17 [1] & ALL OTHER PINS IN CONNECTOR CASE
P17 [2] TO J11 [ a ] P17 [2] & ALL OTHER PINS IN CONNECTOR CASE
P17 [3] TO P2 [GG] P17 [3] & ALL OTHER PINS IN CONNECTOR CASE
P17 [4] TO P2 [ z ] P17 [4] & ALL OTHER PINS IN CONNECTOR CASE
P17 [5] TO P2 [ k ] P17 [5] & ALL OTHER PINS IN CONNECTOR CASE
P17 [6] TO P2 [ m ] P17 [6] & ALL OTHER PINS IN CONNECTOR CASE
YES
RETURN TO SERVICE
NOTE:
WHEN A NEW DCU IS INSTALLED ON THE ENGINE, YOU MAY
HAVE TO UPDATE THE ACCUMULATED CYCLES IN THE DCU
TO ACCOUNT FOR CYCLES THAT MAY NOT HAVE BEEN
COUNTED BY THE DCU WHILE THE FAULT CODE WAS PRESENT.
C129044
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SET CONDITION
LEVER AT FUEL CUTOFF
POSITION. TURN EEC
POWER OFF. REMOVE YES REPLACE
CONNECTOR P2 FROM EEC
EEC. ARE THERE 28 VDC
ON P2 − s OF ENGINE
HARNESS?
NO
CHECK CONTINUITY.
ENGINE HARNESS NO REPAIR / REPLACE
LINE 134 LESS ENGINE
THAN OR EQUAL TO HARNESS
0.5 OHM?
YES
YES
INVESTIGATE
AIRCRAFT WIRING.
ARE THERE 28 VDC NO
ON ENGINE HARNESS RECTIFY
DISCONNECT P11 − j
WHEN PROPELLER IS
FEATHERED?
YES
SYSTEM NORMAL
C26419A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
INVESTIGATE
AIRCRAFT WIRING TO YES SYSTEM
PLA ENABLE
NORMAL
MICROSWITCHES
(REF. AMM). OK?
C26418
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
CONTINUED ON SHEET 2
C26414
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONT’D FROM
SHEET 1
YES
YES
YES
C26341
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
YES
CONTINUED ON SHEET 4
C26415
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
CONTINUED ON SHEET 4
YES
REPLACE AIRCRAFT
TORQUE INDICATOR
(REF. AMM)
C26416
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
NO
NO
C26417
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
AIRCRAFT SYSTEM NO
RECTIFY
OK? (REF. AMM)
YES
SYSTEM NORMAL
C26413
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26412
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26411
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
DUAL AIRSPEED INPUT FAULT
(IASIF)
SYMPTOMS SUSPECT LRU
POSSIBLE TORQUE SPLIT 1. EEC AND
POSSIBLE DEGRADE ENGINE AND PROPELLER 2. ADC
PERFORMANCE 3. WIRING
LRU 19
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT IS SET WHEN BOTH ARINC AIRSPEED INPUT FAULT (LRU = 54) AND DELTA
P SENSOR FAULT (LRU = 17) ARE SET.
C26439
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
C26410
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION YES
PLUG (REF. 72−01−10) SYSTEM NORMAL
OK?
NO
REPLACE EEC
(REF. 72−01−10)
OK?
YES
SYSTEM NORMAL
C37697
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FAILURE
UPTRIM LAMP WRAPAROUND
(LSS4IF)
NO REPAIR / REPLACE
UPTRIM LAMP RELAY OK (REF. AMM)? (REF. AMM)
YES
NO REPLACE WIRING
CONTINUITY ON LINE 133 LESS THAN
HARNESS
OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE UPTRIM LAMP DRIVER SYSTEM IS FOUND TO BE INCORRECT.
C26409
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
C26407
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
DIRTY
NO
DISCONNECT P1 AND P8. TEST
REPLACE NO HARNESS LINES 114, 115, 116, 117
HARNESS AND 118 FOR CONTINUITY SHAKING
P8 CONNECTOR
YES
YES
C26408
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
C26406
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26405
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26404
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS. CONTINUITY ON LINES 119, 120, NO
HARNESS
121 AND 122 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE PLA NO. 2 SIGNAL FROM THE MFCU RVDT FAILS A RANGE CHECK.
C26403
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
C26402
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR /REPLACE
APPLY GROUND TO PIN P11−B (−). IGNITION NO
AIRCRAFT WIRING /
COMES ON (ASSUMING GOOD IGNITERS)?
RELAY (REF. AMM)
YES
YES
NOTE: THIS FAULT IS SET IF EITHER THE AIRCRAFT / ENGINE SYSTEM IS NOT OPERATIONAL
OR THE EEC IS DAMAGED INTERNALLY.
C26401
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO REPAIR /REPLACE
APPLY 28 VDC TO PINS P11−AA (+) AND P11− b (−).
AIRCRAFT WIRING /
MANUAL LAMP OFF?
RELAY (REF. AMM)
YES
NO REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON LINES
ENGINE HARNESS
136 AND 137 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THE VOLTAGE SUPPLIED BY THE EEC TO THE FAIL FIXED RELAY AND THE MFCU STEPPER MOTOR
COMES FROM THE SAME DRIVER. THEREFORE, A SHORT CIRCUIT TO GROUND ON ANY ONE OF
THESE CIRCUITS WILL RESULT IN FAULT CODE LRU 85 BEING SET.
C26400
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 103, NO
HARNESS
104, 128 AND 129 LESS THAN 0.5 OHM?
(REF. 72−01−60)
YES
YES
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO PREVIOUS FAULT
CODES ARE SET FOR ANY OF THE NH PROBES AND THE DIFFERENCE BETWEEN THE TWO
READINGS EXCEEDS 0.9%.
C26399
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS CONTINUITY. RESISTANCE ON LINES NO
ENGINE HARNESS
128 AND 129 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH <30%), NPT IS
ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26398
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
YES
REPLACE NH
CONTINUITY OF NH SENSOR NO. 1, PINS J14−3 NO
SENSOR NO. 1
TO J14−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
NOTE: THIS FAULT WILL BE SET ONCE A LOW RANGE FAILURE IS DETECTED (NH<30%), NPT
IS ABOVE 30% AND FEATHER IS NOT COMMANDED.
C26397
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE NH
CONTINUITY OF NH SENSOR NO. 2, PINS J5−3 NO
SENSOR NO. 2
TO J5−4, 36 TO 45 OHMS (COIL RESISTANCE)?
(REF. 72−01−60)
YES
YES
C26396
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
TAKE APPROPRIATE
NH EXCEEDS 110% AND FAULT CODES YES ACTION FOR NH
LRU 12 AND 81 EXIST? OVERSPEED
(REF. 05−50−00)
NO
YES
YES
C26395
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE ELECTRICAL
CHECK HARNESS CONTINUITY. LINES 100, 101 NO
HARNESS
AND 102 LESS THAN OR EQUAL TO 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF THE INLET TEMPERATURE SENSOR LOCATED ON THE REAR INLET CASE
DOES NOT PASS A RANGE CHECK WHEN NH IS ABOVE 66% (I.E. THE ENGINE RUNNING).
C26394
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULT CODES FOR THE
COILS ARE SET AND THE DIFFERENCE BETWEEN THE TWO NPT COIL READINGS EXCEEDS 5%.
C26393
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPAIR / REPLACE
CHECK HARNESS. IS CONTINUITY ON LINES NO
HARNESS
105, 106, 110 AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF NPT IS ABOVE 30%, FEATHER IS NOT COMMANDED, NO FAULTS ARE SET FOR
ANY COILS AND THE DIFFERENCE BETWEEN THE TWO TORQUE COIL READINGS EXCEEDS 5%.
C26392
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: WHEN THIS SIGNAL FAILS, THE EEC WILL DEFAULT TO A TORQUE SHAFT TEMPERATURE OF
80.5 ° C (176.6 ° F). THIS FAULT IS SET IF THE TORQUE TEMPERATURE SIGNAL FAILS TO PASS
A RANGE CHECK.
C26438
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26390
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
FOLLOW APPROPRIATE
YES
NP EXCEEDS 135% MAINTENANCE ACTION FOR
NP OVERSPEED (REF. 05−50−00)
NO
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26389
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO. 2.
C26388
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 105 NO
HARNESS
AND 106 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 2 OF TORQUE SENSOR NO.2.
C26387
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26437
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO RECONNECT
IS CONNECTOR P1 SECURELY MATED TO J1?
P1 TO EEC
YES
NOTE: THIS FAULT IS SET IF LRU 74/78/84/90 ARE ALL SIMULTANEOUSLY LATCHED. THESE LRU’s
CORRESPOND TO THE TORQUE SHAFT TEMPERATURE, NACELLE AMBIENT TEMPERATURE
AND E1 AND E2 SIGNALS FROM THE RVDT IN THE MFC.
C26436
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: THIS FAULT IS SET IF FOLLOWING ENGINE START, NPT GOES ABOVE 25%, FEATHER IS NOT
COMMANDED (CLA OUT OF FEATHER POSITION) AND A SUBSEQUENT NPT VALUE IS LOWER THAN 21%.
C26384
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
YES
NOTE: THIS FAULT IS SET IF NPT EXCEEDS 135% AND FEATHER IS NOT COMMANDED.
C26383
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE LOWER THAN −20%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26382
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 110 NO
HARNESS
AND 111 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
YES
YES
NOTE: TO SET THIS FAULT, NPT MUST BE BETWEEN 21% AND 135%, FEATHER NOT COMMANDED AND
TORQUE OVER 230%. THIS FAULT IS SPECIFIC TO COIL NO. 1 OF TORQUE SENSOR NO.2.
C26381
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 1 PSIA IN MCL AND MCR RATINGS
AND +− 0.5 PSIA FOR OTHER RATINGS WITH PLA ABOVE 40 DEGREES.
C26380
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE ENGINE IS NOT RUNNING.
THIS FAULT IS SET IF ADC AND EEC PROBES DIFFER BY MORE THAN +− 28 ° F IN MCL AND MCR RATINGS
AND +− 14° F FOR OTHER RATINGS, TORQUE OUTPUT IS 90% OF TQBUG, AND PLA IS GREATER THAN
40 DEGREES.
C26379
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26435
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT IS SET IF THE FOLLOWING TORQUE LEVELS ARE MAINTAINED FOR THE CONTINUOUS
PERIODS INDICATED:
TORQUE BETWEEN (%) TORQUE VAL (LB. FT.) TORQUE PERIOD (SEC)
C26434
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
RECORD OVERTORQUE IN
LOG BOOK
NOTE: THIS FAULT OCCURS WHEN THE ENGINE TORQUE IS BETWEEN 122% AND 137% (12800 −14440
LB. FT. ) FOR A CONTINUOUS PERIOD OF TIME GREATER THAN 20 AND LESS THAN 3000 SECONDS,
OR WHEN THE ENGINE TORQUE IS BETWEEN 100% AND 122% (10504−12800 LB. FT.) FOR A
CONTINUOUS PERIOD OF TIME GREATER THAN 600 SECONDS.
C26433
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26378
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26377
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
NO
SYSTEM NORMAL
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND OUT OF FEATHER
WITH NPT ABOVE 60% SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED WHEN THE
ENGINE IS NOT RUNNING.
C26376
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26374
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
REPLACE EEC
(REF. 72−01−10)
NOTE: INITIAL SYSTEM CHECKS MUST BE CARRIED OUT WHEN THE ENGINE IS RUNNING AND
OUT OF FEATHER SINCE ALL ADC FAULT ACTIONS AND INDICATIONS ARE INHIBITED
WHEN THE ENGINE IS NOT RUNNING. THIS FAULT IS SET IF THE ARINC INPUT LINK IS
FOUND TO BE INVALID WITH NPT ABOVE 60%.
C26375
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26373
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE WITH
NO
HAS A PW127F MFCU BEEN INSTALLED? CORRECT MFCU
(REF. 72−01−40)
YES
REPAIR / REPLACE
CHECK HARNESS. CONTINUITY ON LINES 124 NO
ENGINE HARNESS
AND 125 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
NOTE: THIS FAULT IS SET IF THE EEC DOES NOT ACKNOWLEDGE CONTINUITY BETWEEN PINS J2− a
AND J2−D OF THE MFCU. THE PW127, PW127E AND PW127F MFCU’s PROVIDE HIGHER FLOWS
FOR OPERATION AT PW127, PW127E AND PW127F POWERS THAN THE PW124B MFCU.
THESE CONNECTED PINS WITHIN THE MFCU ARE A WAY FOR THE EEC
TO IDENTIFY A PW127, PW127E AND A PW127F MFCU.
C26432A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO A WITHIN +− 0.1% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R1)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C95981A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: THE INDICATION TO THE EEC COMES FROM A RANGE CHECK PERFORMED ON
THE OUTPUT WRAPAROUND CIRCUITRY.
REPAIR / REPLACE
CHECK ENGINE HARNESS. CONTINUITY ON NO
ENGINE HARNESS
LINES 112 AND 113 LESS THAN 0.5 OHM?
(REF. 72−01−10)
YES
YES
REPLACE EEC
(REF. 72−01−10)
C26431B
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26370
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: NO FAULT CODE IS SET IF THE INTERNAL ARINC DRIVER IS FOUND TO BE DEFECTIVE.
C26369
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
C26368
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHARACTERIZATION
CHECK CONTINUITY RESISTANCE BETWEEN NO PLUG WITH RESISTOR
PINS. C TO D WITHIN €±1.0% OF VALUE
VALUES R1, R3 AND R4
SHOWN ON PLUG DATA PLATE (R3)?
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26367B
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE
CHECK CONTINUITY RESISTANCE BETWEEN CHARACTERIZATION
NO PLUG WITH RESISTOR
PINS. C TO E WITHIN ± 1.0% OF VALUE
SHOWN ON PLUG DATA PLATE (R4)? VALUES R1, R3 AND R4
AS PER DATA PLATE
YES (REF. 72−01−10)
REPLACE EEC
(REF. 72−01−10)
C26366B
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE DRIFT COMPENSATED FOR VARIATIONS IN TEMPERATURE.
THIS FAULT MAY ALSO OCCUR DUE TO AN ELECTRICAL POWER INTERRUPTION OR POWER
SUPPLY VOLTAGE REDUCTION.
C26365
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
ARE BOTH FULT CODES LRU 28 AND 29 YES CARRY OUT CHECK AS PER
ALSO SET? LRU FAULT CODE 28 AND 29
NO
REPLACE EEC
(REF. 72−01−10)
NOTE: HIGH LEVER SIGNALS (I.E. VDC) ARE PROCESSED AND CONVERTED TO DIGITAL SIGNALS FOR USE
BY THE EEC. EACH SIGNAL IS GAIN COMPENSATED FOR VARIATIONS IN EXCITATION VOLTAGE.
THE GAIN SIGNAL IS CONTINUOUSLY RANGE CHECKED. VALUES OUTSIDE THIS RANGE ARE
CONSIDERED INVALID AND THIS FAULT IS FLAGGED.
C26364
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. AN INTERNAL EEC COLD JUNCTION IS USED TO CORRECT THE GAIN AND THE DRIFT
OF THE EEC PRESSURE TRANSDUCERS FOR THERMAL VARIATIONS.
2. THIS FAULT WILL ALSO SET LRU = 44.
C26430
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DRIFT CORRECTION TO LOW LEVEL (mV) INPUTS IS TO ACCOUNT FOR HARDWARE
AMPLIFIER DRIFT.
C26429
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. LOW LEVEL INPUTS (mV) COMING FROM AMBIENT AND DIFFERENTIAL PRESSURE TRANSDUCERS
ARE GAIN CORRECTED WITHIN THE EEC. THIS GAIN CORRECTION ACCOUNTS FOR STRAIN GAGE
EXCITATION VARIATIONS.
C26428
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THIS DELTA−P PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26427
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. DURING INITIALIZATION, THE EEC LOCATED PRESSURE TRANSDUCER CALIBRATION DATA IS
VERIFIED. IF INVALID, THIS FAULT IS FLAGGED AND THE EEC ASSUMES DEFAULT VALVES.
C26426
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: 1. THE STATIC PRESSURE TRANSDUCER IS LOCATED ON THE EEC AND IS CONTINUOUSLY
CHECKED OVER A SPECIFIC PRESSURE RANGE.
C26425
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING AMBIENT PRESSURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60& (I.E. NOT ON THE GROUND).
C26424
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
SYSTEM NORMAL
NOTE: THIS FAULT IS SET IF BOTH SOURCES SUPPLYING TEMPERATURE TO THE EEC ARE
DETERMINED TO BE INVALID AND NPT IS ABOVE 60% (I.E. NOT ON THE GROUND).
C26423
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
NO
NO
NO
C26355
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
C26354A
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
YES
YES
CONTINUED ON SHEET 2
C26422
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NO
REPLACE EEC
(REF. 72−01−10)
C26353
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FUNCTION PERFORMS A GENERAL CHECK ON THE EEC TORQUE CONVERSION PROCESS.
THE CHECK WILL DETECT AN INTERNAL EEC FAILURE OF THE TORQUE / NPT CONVERSION PROCESS.
C26421
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
THIS FAULT IS CAUSED BY A DUAL NH FAILURE AND THE MAINTENANCE PROCEDURE FOR
LRU 12 IS TO BE FOLLOWED.
THIS FAULT SENDS A "DASH−DASH" OUTPUT TO THE COCKPIT ON ARINC LABEL 343 TO TELL
THE PILOT THAT THE INTERCOMPRESSOR BLEED VALVE IS NOT OPERATIONAL.
C26420
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE: THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26349
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
REPLACE EEC
(REF. 72−01−10)
NOTE : THIS FAULT MAY ALSO OCCUR DUE TO AN EEC ELECTRICAL POWER INTERRUPTION.
C26348
Printed on: 14 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
INSPECT ELECTRICAL
IS THE CONTINUITY RESISTANCE (OHMS) IS NO.1 TORQUE PROBE HARNESS AND CONNECTORS
OF THE AFU CONNECTOR P16 YES CONNECTOR PIN CONTINUITY YES (REF. 72−01−10, INSPECTION/
EXCEEDING 750m Ω (0.75 Ω ) ? AND ISOLATION (REF. 72−01−60) CHECK OR AMM). HARNESS
(NOTE 2) WITHIN LIMITS AND CONNECTOR OK?
NO NO
NO
RETURN TO SERVICE
(NOTE 3)
C120742
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões
CD Issue Date: 21 JAN/10
NOTE 1:
UNCOMMANDED AUTOFEATHER CAN SOMETIMES BE INTERPRETED AS AN ENGINE FLAMEOUT. ENGINE
PARAMETER LEADING TO THE EVENT SHOULD BE REVIEWED WITH THE AIRFRAME FLIGHT DATA RECORDER TO
CONFIRM THE UNCOMMANDED AUTOFEATHER. FOR PW124B, AN OVERTORQUE COULD BE RECORDED PRIOR
TORQUE DROPPING TO ZERO.
NOTE 2:
IDENTIFY EXCEEDING CONTINUITY RESISTANCE (OHMS) OF THE ELECTRICAL CIRCUIT BY DISCONNECTING THE AFU
CONNECTOR. THE ELECTRICAL CIRCUIT INSPECTED IS THE TORQUE PROBE NO. 1 WITH THE HARNESS CONNECTOR
P6.
STEP 1
DISCONNECT CONNECTOR P16 AT AFU. MEASURE AND RECORD PIN − TO − PIN RESISTANCE VALUE (OHMS) OF THIS
CONNECTOR AS FOLLOWS (REF. 71−01−10):
− BETWEEN PINS H AND J (APPLICABLE TO ENGINE MODELS : PW124B/127/127E/127F/127M)
− BETWEEN PINS K AND L (APPLICABLE TO ENGINE MODELS : PW124B/127)
STEP 2
DISCONNECT TORQUE PROBE NO. 1 AND INSPECT AS PER 72−01−60. ALSO, MEASURE AND RECORD
PIN − TO − PIN RESISTANCE VALUE (OHMS) AS FOLLOWS:
− BETWEEN PINS A AND B (APPLICABLE TO ENGINE MODELS: PW124B/127/127E/127F/127M)
− BETWEEN PINS C AND D (APPLICABLE TO ENGINE MODELS : PW124B/127)
STEP 3
THE DIFFERENCE OF THE RESISTANCE VALUES MEASURED IN STEPS 1 AND 2 SHOULD NOT EXCEED THE
FOLLOWING:
− RESISTANCE VALUE OF (PINS H TO J) MINUS (PINS A TO B) < 750m Ω (APPLICABLE TO ENGINE MODELS:
PW124B/127/127E/127F/127M)
− RESISTANCE VALUE OF (PINS K TO L) MINUS (PINS C TO D) < 750m Ω (APPLICABLE TO ENGINE MODELS : PW124B/127)
NOTE − 3:
IF OTHER OCCURRENCES OF UNCOMMANDED AUTOFEATHER ARE EXPERIENCED FOLLOWING THE AFU
REPLACEMENT, REFER TO AMM FOR FURTHER INVESTIGATION.
C120743A
Printed on: 15 AUG/11. P&WC Proprietary - subject to restrictions in Technical Data Agreement
Elaborated by Julio.Simões