Professional Documents
Culture Documents
Base Ring................................................................................................................................................................1
i
Base Ring
Inputs
Base configuration double base plate
Base plate material SA 36
Base plate allowable stress, Sp 1.406,139 kgf/cm2
Foundation compressive strength 1.406,139 kgf/cm2
Bolt circle, BC 1.546 mm
Base plate inner diameter, Di 1.350 mm
Base plate outer diameter, Do 1.600 mm
Base plate thickness, tb 25 mm
Gusset separation, w 160 mm
Gusset height, h 250 mm
Gusset thickness, tg 12 mm
Compression ring width 90 mm
Compression ring thickness, tc 20 mm
Anchor Bolts
Material SA 307
Allowable stress, Sb 1.406,139 kgf/cm2
Bolt size and type M24 x 3
Number of bolts, N 12
Corrosion allowance (applied to root radius) 3 mm
Anchor bolt clearance 9,53 mm
Bolt root area (corroded), Ab 1,79 cm2 (AISC 4-147, 9th Ed.)
Diameter of anchor bolt holes, db 33,53 mm
Initial bolt preload 0% (0 kgf/cm2)
Bolt at 0° No
Results Summary
Foundation
Vessel Base V Base M W
Required tr bearing tr comp tr
Load bolt area Base ring gusset
condition (kgf) (kgf-m) (kg) stress
(cm2) (mm) (mm) (mm)
(kgf/cm2)
P = -0,6*W / N + 4 * M / (N*BC)
= -0,6*7.839,42 / 12 + 4 * 1.369 / (12*1,546)
= -96,81 kgf
The anchor bolts are satisfactory (no net uplift on anchor bolt)
Ic = π*(Do4 - Di4) / 64
= π*(1604 - 1354) / 64
= 1,5866E+07 cm4
fc = N*Ab*Preload / Ac + W / Ac + M / 2*Do / Ic
= 12*3,4891*0 / 5.686,384 + 7.839,42 / 5.686,384 + 10*1.369 / 2*1.600 / 1,5866E+07
= 2,069 kgf/cm2
tr = (6*Mmax / Sp)0,5
= (100*6*63,57 / 1.406,139)0,5
= 5,21 mm
Check the compression ring for bolt load (Jawad & Farr equation 12.13)
tcr = (3,91*F / (Sy*(2*b / w+w / (2*l)-db*(2 / w+1 / (2*l)))))0,5
= (3,91*0 / (2.531,05*(2*90 / 160+160 / (2*62,99)-33,53*(2 / 160+1 / (2*62,99)))))0,5
= 0 mm
r = 0,289*tg
= 0,289*12
= 3,47 mm
Ag = tg*(b - 0,25)
= 0.01*12*(90 - 0,25)
= 10,038 cm2
Sg = F / (2 * Ag)
= 0 / (2 * 10,038)
= 0 kgf/cm2
Check skirt thickness for bolt load reaction (Brownell & Young eq. 10.59)
Note: No local skirt reaction is present because the foundation resists the initial bolt preload.
P = -0,6*W / N + 4 * M / (N*BC)
= -0,6*9.018,04 / 12 + 4 * 1.368,4 / (12*1,546)
= -155,86 kgf
The anchor bolts are satisfactory (no net uplift on anchor bolt)
Ic = π*(Do4 - Di4) / 64
= π*(1604 - 1354) / 64
= 1,5866E+07 cm4
fc = N*Ab*Preload / Ac + W / Ac + M / 2*Do / Ic
= 12*3,4891*0 / 5.686,384 + 9.018,04 / 5.686,384 + 10*1.368,4 / 2*1.600 / 1,5866E+07
= 2,276 kgf/cm2
tr = (6*Mmax / Sp)0,5
= (100*6*69,93 / 1.406,139)0,5
= 5,46 mm
Check the compression ring for bolt load (Jawad & Farr equation 12.13)
r = 0,289*tg
= 0,289*12
= 3,47 mm
Ag = tg*(b - 0,25)
= 0.01*12*(90 - 0,25)
= 10,038 cm2
Sg = F / (2 * Ag)
= 0 / (2 * 10,038)
= 0 kgf/cm2
Check skirt thickness for bolt load reaction (Brownell & Young eq. 10.59)
Note: No local skirt reaction is present because the foundation resists the initial bolt preload.
P = -0,6*W / N + 4 * M / (N*BC)
= -0,6*7.201,44 / 12 + 4 * 999,5 / (12*1,546)
= -144,57 kgf
The anchor bolts are satisfactory (no net uplift on anchor bolt)
Ic = π*(Do4 - Di4) / 64
= π*(1604 - 1354) / 64
= 1,5866E+07 cm4
fc = N*Ab*Preload / Ac + W / Ac + M / 2*Do / Ic
= 12*3,4891*0 / 5.686,384 + 7.201,44 / 5.686,384 + 10*999,5 / 2*1.600 / 1,5866E+07
= 1,77 kgf/cm2
Mx = 0.01*0,0174*1,77*220,742 = 15 kgf
tr = (6*Mmax / Sp)0,5
= (100*6*54,4 / 1.406,139)0,5
= 4,82 mm
Check the compression ring for bolt load (Jawad & Farr equation 12.13)
r = 0,289*tg
= 0,289*12
= 3,47 mm
Sg = F / (2 * Ag)
= 0 / (2 * 10,038)
= 0 kgf/cm2
Check skirt thickness for bolt load reaction (Brownell & Young eq. 10.59)
Note: No local skirt reaction is present because the foundation resists the initial bolt preload.
P = -0,6*W / N + 4 * M / (N*BC)
= -0,6*8.380,06 / 12 + 4 * 1.002 / (12*1,546)
= -202,96 kgf
The anchor bolts are satisfactory (no net uplift on anchor bolt)
Ic = π*(Do4 - Di4) / 64
= π*(1604 - 1354) / 64
= 1,5866E+07 cm4
fc = N*Ab*Preload / Ac + W / Ac + M / 2*Do / Ic
= 12*3,4891*0 / 5.686,384 + 8.380,06 / 5.686,384 + 10*1.002 / 2*1.600 / 1,5866E+07
= 1,979 kgf/cm2
Check the compression ring for bolt load (Jawad & Farr equation 12.13)
r = 0,289*tg
= 0,289*12
= 3,47 mm
Ag = tg*(b - 0,25)
= 0.01*12*(90 - 0,25)
= 10,038 cm2
Sg = F / (2 * Ag)
= 0 / (2 * 10,038)
= 0 kgf/cm2
Check skirt thickness for bolt load reaction (Brownell & Young eq. 10.59)
Note: No local skirt reaction is present because the foundation resists the initial bolt preload.
P = -0,6*W / N + 4 * M / (N*BC)
= -0,6*20.792,36 / 12 + 4 * 993,4 / (12*1,546)
= -825,44 kgf
The anchor bolts are satisfactory (no net uplift on anchor bolt)
Ic = π*(Do4 - Di4) / 64
= π*(1604 - 1354) / 64
= 1,5866E+07 cm4
fc = N*Ab*Preload / Ac + W / Ac + M / 2*Do / Ic
= 12*3,4891*0 / 5.686,384 + 20.792,36 / 5.686,384 + 10*993,4 / 2*1.600 / 1,5866E+07
= 4,157 kgf/cm2
tr = (6*Mmax / Sp)0,5
= (100*6*127,75 / 1.406,139)0,5
= 7,38 mm
Check the compression ring for bolt load (Jawad & Farr equation 12.13)
r = 0,289*tg
= 0,289*12
= 3,47 mm
Ag = tg*(b - 0,25)
= 0.01*12*(90 - 0,25)
= 10,038 cm2
Sg = F / (2 * Ag)
= 0 / (2 * 10,038)
= 0 kgf/cm2
Check skirt thickness for bolt load reaction (Brownell & Young eq. 10.59)
Note: No local skirt reaction is present because the foundation resists the initial bolt preload.
The area provided (1,7852 cm2) by the specified anchor bolt is adequate.
Ic = π*(Do4 - Di4) / 64
= π*(1604 - 1354) / 64
= 1,5866E+07 cm4
tr = (6*Mmax / Sp)0,5
= (100*6*188,09 / 1.406,139)0,5
= 8,96 mm
Check the compression ring for bolt load (Jawad & Farr equation 12.13)
r = 0,289*tg
= 0,289*12
= 3,47 mm
Ag = tg*(b - 0,25)
= 0.01*12*(90 - 0,25)
= 10,038 cm2
Sg = F / (2 * Ag)
= 1.648,66 / (2 * 10,038)
= 82,121 kgf/cm2
Check skirt thickness for bolt load reaction (Brownell & Young eq. 10.59)
The area provided (3,4891 cm2) by the specified anchor bolt is adequate.
Ic = π*(Do4 - Di4) / 64
= π*(1604 - 1354) / 64
= 1,5866E+07 cm4
tr = (6*Mmax / Sp)0,5
= (100*6*214,15 / 1.406,139)0,5
= 9,56 mm
Check the compression ring for bolt load (Jawad & Farr equation 12.13)
r = 0,289*tg
= 0,289*12
= 3,47 mm
Ag = tg*(b - 0,25)
= 0.01*12*(90 - 0,25)
= 10,038 cm2
Sg = F / (2 * Ag)
= 1.865,76 / (2 * 10,038)
= 92,935 kgf/cm2
Check skirt thickness for bolt load reaction (Brownell & Young eq. 10.59)
The area provided (1,7852 cm2) by the specified anchor bolt is adequate.
Ic = π*(Do4 - Di4) / 64
= π*(1604 - 1354) / 64
= 1,5866E+07 cm4
tr = (6*Mmax / Sp)0,5
= (100*6*169,68 / 1.406,139)0,5
= 8,51 mm
Check the compression ring for bolt load (Jawad & Farr equation 12.13)
r = 0,289*tg
= 0,289*12
= 3,47 mm
Ag = tg*(b - 0,25)
= 0.01*12*(90 - 0,25)
= 10,038 cm2
Gusset allowable stress
Sg = F / (2 * Ag)
= 1.471,33 / (2 * 10,038)
= 73,288 kgf/cm2
Check skirt thickness for bolt load reaction (Brownell & Young eq. 10.59)
The area provided (3,4891 cm2) by the specified anchor bolt is adequate.
Ic = π*(Do4 - Di4) / 64
= π*(1604 - 1354) / 64
= 1,5866E+07 cm4
Mx = 0.01*0,0174*6,372*220,742 = 54 kgf
tr = (6*Mmax / Sp)0,5
= (100*6*195,79 / 1.406,139)0,5
= 9,14 mm
r = 0,289*tg
= 0,289*12
= 3,47 mm
Ag = tg*(b - 0,25)
= 0.01*12*(90 - 0,25)
= 10,038 cm2
Sg = F / (2 * Ag)
= 1.689,07 / (2 * 10,038)
= 84,134 kgf/cm2
Check skirt thickness for bolt load reaction (Brownell & Young eq. 10.59)