You are on page 1of 1

SEISMIC COMPONENT OF SUPER-STRUCTURE DL & SIDL :

Longitudinal Horizontal seismic coefficent AhL = 0.162


Transverse Horizontal seismic coefficent AhT = 0.162
Vertical seismic coefficent AV = 0.108

Sub-structure Vertical load


Description W eY eL eT
Tonne m m m
Sub-structure 156.6 5.2 0.00 0.00
Pile cap 199.7 0.9 0.00 0.00

W = Weight of super-structure
ey = Cg. above base slab in vertical direction

SEISMIC LONGITUDINAL : Sub-Structure Pile Cap


Longitudinal seismic coefficent AhL = 0.162 0.162
Total weight of Sub-structure = 156.6 Tonne 199.7 Tonne

Seismic Component HL = 25.4 Tonne 32.3 Tonne


Lever arm above base slab = 5.2 m 0.9 m
Moment about T-T axis MTT = 131.4 Tm 29.1 Tm

SEISMIC TRANSVERSE :
Horizontal seismic coefficent AhT = 0.162 0.162
Total weight of Sub-structure = 156.6 Tonne 199.7 Tonne

Seismic Component HT = 25.4 Tonne 32.3 Tonne


Lever arm above base slab = 5.2 m 0.9 m
Moment about LL axis MLL = 131.4 Tm 29.1 Tm

SEISMIC VERTICAL :
Horizontal seismic coefficent Av = 0.108 0.108
Total weight of Sub-structure = 156.6 Tonne 199.7 Tonne

Seismic Component = 16.9 Tonne 21.6 Tonne


Lever arm along LL axis = 0.00 m 0.00 m
Lever arm along TT axis = 0.00 m 0.00 m

Moment about LL axis MLL = 0.00 Tm 0.00 Tm


Moment about TT axis MTT = 0.00 Tm 0.00 Tm

Summery of Sub-structure seismic component :


At Fixed End V HL HT MTT MLL
T T T Tm Tm
Seismic Longitudinal 25.4 131.4

Seismic Transverse 25.4 131.4

Seismic Vertical 16.9 0.0 0.0

Summery of Pile cap seismic component :