You are on page 1of 1

1 2 3 4 5

01/12/21
NOTE: Key Note - Elevation/Section B1900665

ALTHOUGH THERE ARE SOME EXCEPTIONS/OVERLAPS, KEYNOTE #Description


NUMBERS ARE GENERALLY ORGANIZED AS FOLLOWS:

001-099 EXISTING CONDITIONS/DEMOLITION PLANS 002 EXISTING MASONTY EXTERIOR WALL TO REMAIN
100-199 CONSTRUCTION PLANS 003 EXISTING PARTY WALL TO REMAIN
200-299 EXTERIOR ELEVATIONS 004 EXISTING CONCRETE FOOTING TO REMAIN
300-399 SECTIONS
12/8/2020 400-499 WALL SECTIONS
102 NEW 72" DIAMETER PRE-FAB STEEL SPIRAL STAIRCASE & RAILING, BY
STAIRWAYSHOP.COM
103 COMPOSITE DECKING PAVERS ON PEDESTALS
104 NEW 36" TALL CABLE GUARDRAIL, 4" MAX. CABLE SPACING
106 NEW WOOD STAIRS WITH OPEN RISER
107 NEW PRE-FINISHED HARDWOOD FLOORING
110 THIN-SET PORCELAN TILE FLOORING Structural Review - Wayne Ferguson - 01-12-2021
D D
DOEE SE-SW Review - Nykia Barnes - 01-12-2021
111 WOOD HANDRAIL ON SS BRACKETS, 34" ABOVE STAIR NOSING DOEE EV Review - Sheng Huang - 01-12-2021
112 ELECTRICAL PANEL LOCATION
113 NEW FLOOR STRUCTURAL FRAMING AND INSULATION; SEE STRUCTURAL
DRAWINGS
115 NEW FRT WOOD AND COMPOSITE DECKING EXT. STAIRS
117 FIRE RATED PARAPET
200 EXISTING WINDOWS TO REMAIN
201 NEW WINDOWS, DOORS; REF TO DOOR/WINDOW SCHEDULE
202 NEW SKYLIGHT; REFER TO WINDOW SCHEDULE & REFER TO
MANUFACTURER: GLAZING VISION
203 SCHEDULED LIGHT FIXTURE
204 JAMES HARDIE PLANK SIDING
205 TOP EDGE OF ROOF
206 CRAWLSPACE ACCESS PANEL.
207 STANDING SEAM MTL MANSARD ROOF
300 TEMPERED GLASS
301 PAINTED FIBER CEMENTFASCIA BOARD
302 SCHEDULED DOOR
304 RECTANGULAR MTL GUTTER; TYP
306 FLOOR FIRE SEPARATION 1HR, REFER TO SHEET A0012
307 CHIMNEY
308 CONCRETE FOUNDATION WALL; SEE STRUCTURAL DRAWINGS
403 STANDING SEAM MTL MANSARD ROOF
406 VAPOR BARRIER
407 FOUNDATION WATERPROOFING
408 R-13 RIGID INSULATION AT PERIMETER OF CONCRETE SLAB EDGE
409 R-49 RIGID INSULATION
410 R-19 BATT INSULATION CONSULTANTS
414 TPO ROOF MEMBRANE ON TAPERED RIGID INSULATION. STRUCTURAL ENGINEER:
415 METAL FLASHING
C 417 1-HR FIRE SEPARATION FOR 4' ALONG PROPERTY LINE, BOTH SIDES OF C
BUILDING. PER IBC 2012 SECTION 705.11 EXCEPTION 2.5 FROM PARAPET
REQUIREMENTS, PROVIDE 5/8" TYPE X GWB ON UNDERSIDE OF ROOF
SHEATHING, BETWEEN FRAMING MEMBERS, SECURE TO NOMINAL 2X2
LEDGERS.

REGISTRATION

CATARINA FERREIRA, AIA

WASHINGTON DC Digitally signed by


LICENSE NO. ARC 101008 Catarina Catarina Ferreira, AIA
Ferreira, AIA Date: 2020.04.06
14:05:00 -04'00'
202 202
ATTESTATION STATEMENT:
307

3' - 0"
205 307 414 I AM RESPONSIBLE FOR DETERMINING THAT THE ARCHITECTURAL DESIGNS INCLUDED
IN THIS APPLICATION ARE IN COMPLIANCE WITH ALL LAWS & REGULATIONS OF THE
DISTRICT OF COLUMBIA. I HAVE PERSONALLY PREPARED OR DIRECTLY SUPERVISED
New Roof New Roof THE DEVELOPMENT OF THE ARCHITECTURAL DESIGNS INCLUDED IN THIS APPLICATION.

29' - 5 1/32" 414 29' - 5 1/32" PROJECT INFORMATION


304

1' - 3"
1734 Mass Ave 2 Family
207
10' - 1"

10' - 1"
Donal & Taren Langhorne

5' - 0"
04 05 05 04
03 03 03 1734 Massachusetts Ave SE
7' - 0"

FIRE FIRE FIRE FIRE FIRE


EGRESS 201 EGRESS EGRESS 304 EGRESS EGRESS

B B PROJECT NUMBER
201
2018-15

2' - 7"
301 ISSUE RECORD
3rd Floor MARK DATE DESCRIPTION
19' - 4" 3rd Floor 1 09/28/18 BUILDING PERMIT
19' - 4"
204 203 2 02/21/20 PERMIT REV 1
10' - 2"

10' - 2"
BUILDING HEIGHT

E02 E02 E02

7' - 7 3/4"
104
32' - 11"

32' - 11"

200
102

3' - 2 1/2"
002
2nd Floor 2nd Floor
9' - 2" 9' - 2"
103

200
E01
9' - 2"

9' - 2"
7' - 11"
7' - 0"

1st Floor 1st Floor


A 0' - 0" 3' - 0" 0' - 0" A
115 DRAWING INFORMATION

Foundation Foundation Drawing Scale: 1/4" = 1'-0"

2' - 0"
-1' - 9" 206 -1' - 9" Drawn By: TB
Grade - B.H.M.P. Grade - B.H.M.P. Checked By: CF
-3' - 6" -3' - 6"
Exterior Elevations
01 Front Elevation
SCALE 1/4" = 1'-0"
02 Rear Elevation
SCALE 1/4" = 1'-0"

1 2 3 4
0' 2' 4'
5
8' 16' A0200
C:\Users\Catarina Ferreira\Documents\2018-15_1734_MASS_AVE_2_FAMILY_20-New_CatarinaFerreira4652.rvt 4/6/2020 2:00:40 PM COPYRIGHT © archi-TEXTUAL, PLLC 2015

You might also like