UTILITIES DAILY - MAINTENANCE CHECK LIST 01-08-18
REV. NO & DATE :00/ 01-09-19

Machine Name DG-125 KVA Machine ID Frequency Daily Month & Year 8/1/2019

Checking
Freq ID No Inspection items Standard condition 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
method

Safety Instruction: Put ECS
switch in OFF Mode or Weekly, Bi weeklyy &
Remove the Battery Monthly activities must be
Daily 1 Connection While doing
monthly, weekly, Bi weekly
carried out only holiday by
Put ECS in OFF / Remove
Visual It is Important Safety Instruction
PM. Otherwise Major Accident battery Lead
happen

Middle the level of H &


Daily 2 Oil Level Visual
L

Daily 3 Coolant level High level Visual

Daily 4 Fuel level Above 500 litres Visual

No leakages , If found
Fuel / Engine Oil / Visual /
Daily 5 any leak,, Clean ffirst &
Coolant Leak By hand
Find Leak area

Drain the Water


Float Must be in Below Visual /
Daily 6 separator in Fuel
Red Line By hand
system

Ensure the DG Battery Water Level Must be in


Daily 7 Visual
Water Level upper level

Daily 8 Dynamo Belt Condition No Wear & Tear Visual

It should be 24V in
Battery Voltage
Both battery.Individual
Daily 9 Condition It is good or Visual
Battery Voltage is
weak
12V+12V(±0.5V)

Battery Cable Meltiing No Melting &


Daily 10 Visual
or looseness Looseness

1.)Change from Manul


mode.
DG must be run in
2).To START the DG
Daily 11 Manual Mode to 5 Visual
3).monitoring till 5
minutes
minutes
4) To STOP the DG

Name / Intials
LEGEND:
Activity not completed
* Activity completed with abnormality √ Activity completed with no abnormality
DOC. NO : KASI/MAIN/D/
ISSUE NO & DATE :
01/ 01-08-18
UTILITIES DAILY - MAINTENANCE CHECK LIST REV. NO & DATE :00/ 01-09-19

Machine Name DG-125 KVA Machine ID Frequency Daily Month & Year 8/1/2019
31
Checking
Freq ID No Inspection items Standard condition 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
method

Safety Instruction: Put ECS Weekly, Bi weeklyy & Visual


switch in OFF Mode or Monthly activities must be
Remove the Battery carried out only holiday by
Connection While doing Put ECS in OFF / Remove
Weekly 12 monthly, weekly, Bi weekly
PM. Otherwise Major Accident
battery Lead
It is Important Safety Instruction
happen

House Keeping & 5S Clean condition / No Visual


Weekly 13 Unwanted material
inside

Hydraulic Hose Should be Tight Visual


Weekly 14 condition

Engine Breather hose Should be at outside of Visual


Weekly 15 DG

Radiator fan belt No Wear & Tear Visual


Bi- Week 16 condition

Coolant pipelines Tightened & Properly Visual


Bi- Week 17 Fixed

Radiator fan Condition No damages on the Visual


Month 18 blades

Radiator fan belt No Wear & Tear Visual


Month 19 condition

Earth Plate Tightness Should be Tight Visual


Month 20 with Alternator Body

Air intake Free from foreign Visual


Month 21 materials

Coolant Pump incoming No Looseness, No Visual


cable Damage, No Melting in
Month 22 the terminals & Cable

Air Cooling Pump Fasten tightly with Visual


Month 23 Mounting marking

Check Panel - MMI No looseness & No Visual


Month 24 canlee Melt damage

Inspect Fire Extinguiser Not Expiry Visual


Month 25 Expiry Date

Name / Intials
LEGEND:
Activity not completed
* Activity completed with abnormality √ Activity completed with no abnormality