You are on page 1of 3

Annexure-I

Risk Assessment Analysis


(Part A)
General Information

Sr.No. Aspect Details


i) IS No. IS 458 : 2003
ii) Product Precast Concrete Pipes (with and without
Reinforcement)

iii) CM/L- L-4828478


iv) Manufacturer name BAJRANG PIPE INDUSTRIES.
v) Sample code/drawl date CHBO-I/120000390/20220525/FS/1
vi) Sample manufacturing date 25.05.2022
vii) Grade/Type/Size/Variety etc M35, Concrete Cube of ratio - 1:2:3 (Cement
- 1 : Fine Aggregate -2 : Course Aggregate -
3).

viii) Test report issued by IDMA LABORATORIES LIMITED, PLOT NO 391


INDUSTRIAL AREA PHASE 1, PANCHKULA,
Panchkula, Haryana, India - 134113
ix) Test report date 24 Jun, 2022
x) Non-Conforming parameter(s) Failing in the requirement of compressive
strength CL 16.1 of IS 456.
xi) Product shelf life till/expiry -
date(if applicable)
Annexure-II
Part B
Sr.No Aspect Observation/Remarks
.
i) Identification of product and its non- Precast Concrete Pipes (with and
conformity(ies) without Reinforcement)

Failing in the requirement of


compressive strength CL 16.1 of
IS 456.
ii) a) Extent of non-conformity(ies) 1) Compressive Strength of
Individual Samples Min 35.0 -
N/mm2 Observed = 30.2
N/mm2
2) Compressive Strength of
Individual Samples Min 35.0 -
N/mm2 Observed = 20.4
N/mm2
3) Average Compressive
Strength Average
compressive strength (Age 28
days) Min = 35.0 - N/mm2
Observed = 25.0 N/mm2
b) Does the non-conformity(ies) indicate
intentional use of sub-standard raw
materials/inputs No
iii) Nature of non-conformity parameter: Safety Nil
or performance
iv) Identify hazard(s), For example:
a) Thermal hazards like explosion, flame, NIL
radiation, hot surfaces etc.
b) Electrical hazards like live parts, short-
circuits, overload etc.
c) Mechanical hazards like vibration,
instability, break-down during operation,
moving parts susceptible to causing physical
harm to the operator, falling or ejected
objects, edges or corners etc.
d) Chemical/Biological hazard like presence
of toxins, expiry of product etc.

v) Identify subject at risk, For example, Human, NIL


plant, animal, environment etc.
vi) Description of potential harm scenario(s) For No potential harm
example, absence of proper labelling and
marking resulting in consumption of expired
food product

vii) Describing the potential harm(s) For example, No potential harm


potential electrical shock/burn/loss of life
due to leakage of current from electrical wire

viii) Risk assessment about impact of non- No impact on health and safety
conformity on public health/safety Assessing
severity of harm(s) and probability of its
occurrence
ix) Whether the product recall is feasible Yes
(Yes or No)
x) Need for issuance of product recall notice No
(Yes or No) with reasons thereof and if Yes,
List all the non-conformity(ies) which led to
decision for recommending issuance of
product recall notice
Signature Signature Signature
Name: Kushagra Jindal Name: Hitesh Yadav Name: Ajay Maurya
Designation: Sc. B Designation: Sc. B Designation: Sc. C

HCHBO-1

Failure analysis

Probable causes of failure

1.