Professional Documents
Culture Documents
Risk Assessment Analysis (Part A) General Information SR - No. Aspect Details
Risk Assessment Analysis (Part A) General Information SR - No. Aspect Details
viii) Test report issued by Aji Industrial, Bhavnagar Road, Opp Gujarat
Forging, Rajkot, Rajkot, Gujarat, India -
360003
ix) Test report date 30 Jul, 2022
x) Non-Conforming parameter(s) Failing in the requirement of Individual
Marking clause ( Mfg name, Model No.,
Serial No etc) not marked as per CL 16.1 of IS
8472.
xi) Product shelf life till/expiry -
date(if applicable)
Annexure-II
Part B
Sr.No Aspect Observation/Remarks
.
i) Identification of product and its non- Centrifugal Regenerative Pumps
conformity(ies) for Clear, Cold Water –
Specification
viii) Risk assessment about impact of non- No impact on health and safety
conformity on public health/safety Assessing
severity of harm(s) and probability of its
occurrence
ix) Whether the product recall is feasible Yes
(Yes or No)
x) Need for issuance of product recall notice No
(Yes or No) with reasons thereof and if Yes,
List all the non-conformity(ies) which led to
decision for recommending issuance of
product recall notice
HCHBO-1
Failure analysis
1.