You are on page 1of 3

Annexure-I

Risk Assessment Analysis


(Part A)
General Information

Sr.No. Aspect Details


i) IS No. IS 8472 : 2019
ii) Product Centrifugal Regenerative Pumps for Clear,
Cold Water - Specification

iii) CM/L- L-9903592


iv) Manufacturer name Surinder Engg. Works,
v) Sample code/drawl date CHBO-I/120000394/20220514/FS/1
vi) Sample manufacturing date 25-04-2022
vii) Grade/Type/Size/Variety etc 0.37 kW, Single phase, Rated Voltage: 230
Volt, Pump size : 25x25 mm, Side Channel
type, Self priming

viii) Test report issued by Aji Industrial, Bhavnagar Road, Opp Gujarat
Forging, Rajkot, Rajkot, Gujarat, India -
360003
ix) Test report date 30 Jul, 2022
x) Non-Conforming parameter(s) Failing in the requirement of Individual
Marking clause ( Mfg name, Model No.,
Serial No etc) not marked as per CL 16.1 of IS
8472.
xi) Product shelf life till/expiry -
date(if applicable)
Annexure-II
Part B
Sr.No Aspect Observation/Remarks
.
i) Identification of product and its non- Centrifugal Regenerative Pumps
conformity(ies) for Clear, Cold Water –
Specification

Failing in the requirement of


Individual Marking clause ( Mfg
name, Model No., Serial No etc)
not marked as per CL 16.1 of IS
8472.
ii) a) Extent of non-conformity(ies) Mfg name, Model No., Serial No
not provided.

b) Does the non-conformity(ies) indicate


intentional use of sub-standard raw
materials/inputs No
iii) Nature of non-conformity parameter: Safety Nil
or performance
iv) Identify hazard(s), For example:
a) Thermal hazards like explosion, flame, NIL
radiation, hot surfaces etc.
b) Electrical hazards like live parts, short-
circuits, overload etc.
c) Mechanical hazards like vibration,
instability, break-down during operation,
moving parts susceptible to causing physical
harm to the operator, falling or ejected
objects, edges or corners etc.
d) Chemical/Biological hazard like presence
of toxins, expiry of product etc.

v) Identify subject at risk, For example, Human, NIL


plant, animal, environment etc.
vi) Description of potential harm scenario(s) For No potential harm
example, absence of proper labelling and
marking resulting in consumption of expired
food product

vii) Describing the potential harm(s) For example, No potential harm


potential electrical shock/burn/loss of life
due to leakage of current from electrical wire

viii) Risk assessment about impact of non- No impact on health and safety
conformity on public health/safety Assessing
severity of harm(s) and probability of its
occurrence
ix) Whether the product recall is feasible Yes
(Yes or No)
x) Need for issuance of product recall notice No
(Yes or No) with reasons thereof and if Yes,
List all the non-conformity(ies) which led to
decision for recommending issuance of
product recall notice

Signature Signature Signature


Name: Kushagra Jindal Name: Hitesh Yadav Name: Ajay Maurya
Designation: Sc. B Designation: Sc. B Designation: Sc. C

HCHBO-1
Failure analysis

Probable causes of failure